Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Adv Healthc Mater ; 7(21): e1800338, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30221474

RESUMEN

Ti-based bulk metallic glasses are under consideration for implants due to their high yield strength and biocompatibility. In this work, in situ synchrotron X-ray diffraction (XRD) is used to investigate the corrosion products formed from corrosion of Ti40 Zr10 Cu34 Pd14 Sn2 bulk metallic glass in artificial corrosion pits in physiological saline (NaCl). It is found that Pd nanoparticles form in the interior of the pits during electrochemical dissolution. At a low pit growth potential, the change in lattice parameter of the Pd nanoparticles is consistent with the formation of palladium hydride. In addition, a salt layer very close to the dissolving interface is found to contain CuCl, PdCl2 , ZrOCl2 ∙8H2 O, Cu, Cu2 O, and several unidentified phases. The formation of Pd nanoparticles (16 ± 10 nm at 0.7 V vs Ag/AgCl) containing small amounts of the other alloying elements is confirmed by transmission electron microscopy. The addition of albumin and/or H2 O2 does not significantly influence the nature of the corrosion products. When considering the biological compatibility of the alloy, the biological reactivity of the corrosion products identified should be explored.


Asunto(s)
Materiales Biocompatibles/química , Titanio/química , Difracción de Rayos X/métodos , Aleaciones/química , Corrosión , Electrólitos , Microscopía Electrónica de Transmisión , Sincrotrones
2.
J Biomed Mater Res B Appl Biomater ; 104(1): 27-38, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25611821

RESUMEN

Glass-forming Ti-based alloys are considered as potential new materials for implant applications. Ti75 Zr10 Si15 and Ti60 Zr10 Nb15 Si15 alloys (free of cytotoxic elements) can be produced as melt-spun ribbons with glassy matrix and embedded single ß-type nanocrystals. The corrosion and passivation behavior of these alloys in their homogenized melt-spun states have been investigated in Ringer solution at 37°C in comparison to their cast multiphase crystalline counterparts and to cp-Ti and ß-type Ti-40Nb. All tested materials showed very low corrosion rates as expressed in corrosion current densities icorr < 50 nA/cm(2). Electrochemical and surface analytical studies revealed a high stability of the new alloys passive states in a wide potential range. This corresponds to low passive current densities ipass = 2 ± 1 µA/cm(2) based on the growth of oxide films with thickness d <10 nm. A homogeneous constituent distribution in the melt-spun alloys is beneficial for stable surface passivity. The addition of Nb does not only improve the glass-forming ability and the mechanical properties but also supports a high pitting resistance even at extreme anodic polarization up to 4V versus SCE were oxide thickness values of d ∼35 nm are reached. With regard to the corrosion properties, the Nb-containing nearly single-phase glassy alloy can compete with the ß-type Ti-40Nb alloy. SBF tests confirmed the ability for formation of hydroxyapatite on the melt-spun alloy surfaces. All these properties recommend the new glass-forming alloys for application as wear- and corrosion-resistant coating materials for implants.


Asunto(s)
Aleaciones/química , Apatitas/química , Materiales Biocompatibles/química , Cerámica/química , Nanopartículas/química , Corrosión , Niobio/química , Silicatos/química , Silicio/química , Titanio/química , Circonio/química
3.
Mater Sci Eng C Mater Biol Appl ; 33(2): 875-83, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25427501

RESUMEN

Ti-based metallic glasses show high potential for implant applications; they overcome in several crucial respects their well-established biocompatible crystalline counterparts, e.g. improved corrosion properties, higher fracture strength and wear resistance, increased elastic strain range and lower Young's modulus. However, some of the elements required for glass formation (e.g. Cu, Ni) are harmful for the human body. We critically reviewed the biological safety and glass forming tendency in Ti of 27 elements. This can be used as a basis for the future designing of novel amorphous Ti-based implant alloys entirely free of harmful additions. In this paper, two first alloys were developed: Ti(75)Zr(10)Si(15) and Ti(60)Nb(15)Zr(10)Si(15). The overheating temperature of the melt before casting can be used as the controlling parameter to produce fully amorphous materials or bcc-Ti-phase reinforced metallic glass nano-composites. The beneficial effect of Nb addition on the glass-formation and amorphous phase stability was assessed by X-ray diffraction, transmission electron microscopy and differential scanning calorimetry. Crystallization and mechanical behavior of ribbons are influenced by the amount and distribution of the nano-scaled bcc phase existing in the as-cast state. Their electrochemical stability in Ringer's solution at 310 K was found to be significantly better than that of commercial Ti-based biomaterials; no indication for pitting corrosion was recorded.


Asunto(s)
Materiales Biocompatibles/química , Vidrio/química , Prótesis e Implantes , Titanio/química , Corrosión , Dureza , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...