Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Diabetes Care ; 45(10): 2369-2375, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35984478

RESUMEN

OBJECTIVE: The efficacy and safety of continuous glucose monitoring (CGM) in adjusting inpatient insulin therapy have not been evaluated. RESEARCH DESIGN AND METHODS: This randomized trial included 185 general medicine and surgery patients with type 1 and type 2 diabetes treated with a basal-bolus insulin regimen. All subjects underwent point-of-care (POC) capillary glucose testing before meals and bedtime. Patients in the standard of care (POC group) wore a blinded Dexcom G6 CGM with insulin dose adjusted based on POC results, while in the CGM group, insulin adjustment was based on daily CGM profile. Primary end points were differences in time in range (TIR; 70-180 mg/dL) and hypoglycemia (<70 mg/dL and <54 mg/dL). RESULTS: There were no significant differences in TIR (54.51% ± 27.72 vs. 48.64% ± 24.25; P = 0.14), mean daily glucose (183.2 ± 40 vs. 186.8 ± 39 mg/dL; P = 0.36), or percent of patients with CGM values <70 mg/dL (36% vs. 39%; P = 0.68) or <54 mg/dL (14 vs. 24%; P = 0.12) between the CGM-guided and POC groups. Among patients with one or more hypoglycemic events, compared with POC, the CGM group experienced a significant reduction in hypoglycemia reoccurrence (1.80 ± 1.54 vs. 2.94 ± 2.76 events/patient; P = 0.03), lower percentage of time below range <70 mg/dL (1.89% ± 3.27 vs. 5.47% ± 8.49; P = 0.02), and lower incidence rate ratio <70 mg/dL (0.53 [95% CI 0.31-0.92]) and <54 mg/dL (0.37 [95% CI 0.17-0.83]). CONCLUSIONS: The inpatient use of real-time Dexcom G6 CGM is safe and effective in guiding insulin therapy, resulting in a similar improvement in glycemic control and a significant reduction of recurrent hypoglycemic events compared with POC-guided insulin adjustment.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/inducido químicamente , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucosa , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes , Insulina , Insulina Regular Humana
2.
Curr Opin Endocrinol Diabetes Obes ; 29(1): 1-9, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34845159

RESUMEN

PURPOSE OF REVIEW: Continuous glucose monitoring (CGM) systems are Food and Drug Administration approved devices for the ambulatory setting; however, they remain investigational systems for inpatient use. This review summarizes the most recent and relevant literature on the use of continuous glucose monitoring in the hospital setting. RECENT FINDINGS: CGM provides real-time glucose data that enable healthcare professionals to make proactive and timelier clinical decisions with regards to diabetes management. CGM devices appear to be safe and accurate systems for glucose monitoring in the hospital setting. Real-time CGM systems and glucose telemetry can decrease hypoglycemia and reduce hyperglycemia in hospitalized patients with diabetes. Remote glucose monitoring decreases the need of frequent Point-of-care checks and personal protective equipment use while also mitigating staff exposure risk which is timely in the advent of the COVID-19 pandemic. Although most nursing staff have limited exposure and training on CGM technology, early studies show that CGM use in the hospital is well received by nurses. SUMMARY: Given the evidence in the current literature regarding CGM use in the hospital, CGM devices may be incorporated in the inpatient setting.


Asunto(s)
COVID-19 , Diabetes Mellitus Tipo 1 , Glucemia , Automonitorización de la Glucosa Sanguínea , Hospitales , Humanos , Pandemias , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA