Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(8): 2280-5, 2013 Aug.
Artículo en Chino | MEDLINE | ID: mdl-24159894

RESUMEN

Spectral calibration must be carried out in order to determine its central wavelength and half-wave band width of each pixel before the usage of imaging spectrometer. But it was found out that these parameters vary as environment changes. The present paper studies the effect based on test field data. The authors analyzed the optical structure and compared the working environmental parameters. Then a theoretical model is established and the influences of vibration, distortion and temperature parameters are evaluated. The theoretical model and the caculation results are in good consistency, which testifies the theoretical model. This research will shed some light on the high accuracy spectral calibration of the grating based imaging spectrometer and its manufacture.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(2): 571-4, 2013 Feb.
Artículo en Chino | MEDLINE | ID: mdl-23697157

RESUMEN

Retrieval of center wavelength and bandwidth is a key step for quantitative analysis of hyperspectral data. The present paper proposes a spectral calibration method of hyperspectral imager, whose spectrum covers visible and near-infrared band, using spectral absorption target. Ground calibration experiment was designed for a hyperspectral imager with a bandwidth of 6 nm. Hyperspectral imager and ASD spectrometer measured the same spectral absorption target synchronously. Reflectance spectrum was derived from the different data set. Center wavelength and bandwidth were retrieved by matching the reflectance data from hyperspectral imager and ASD spectrometer. The experiment result shows that this method can be applied in spectral calibration of hyperspectral imagers to improve the quantitative studies on hyperspectral imagery.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(2): 430-4, 2012 Feb.
Artículo en Chino | MEDLINE | ID: mdl-22512184

RESUMEN

With the data in Urad Front Banner, Inner Mongolia on November 14th, 2010, hyper-spectral camera on UAV was calibrated adopting reflectance-based method. During the in-flight absolute radiometric calibration, 6 hyper-spectral radiometric gray-scale targets were arranged in the validation field. These targets' reflectances are 4.5%, 20%, 30%, 40%, 50% and 60% separately. To validate the calibration result, four extra hyper-spectral targets with sharp-edge spectrum were arranged to simulate the reflection and absorption peaks in natural objectives. With these peaks, the apparent radiance calculated by radiation transfer model and that calculated through calibration coefficients are much different. The result shows that in the first 15 bands (blue bands), errors are somewhat huge due to the noises of equipment. In the rest bands with quite even spectrum, the errors are small, most of which are less than 10%. For those bands with sharp changes in spectral curves, the errors are quite considerable, varying from 10% to 25%.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(12): 3169-74, 2012 Dec.
Artículo en Chino | MEDLINE | ID: mdl-23427528

RESUMEN

Based on the data of the scientific experiment in Urad Front Banner for UAV Remote Sensing Load Calibration Field project, with the help of 6 hyperspectral radiometric targets with good Lambertian property, the wide-view multispectral camera in UAV was calibrated adopting reflectance-based method. The result reveals that for green, red and infrared channel, whose images were successfully captured, the linear correlation coefficients between the DN and radiance are all larger than 99%. In final analysis, the comprehensive error is no more than 6%. The calibration results demonstrate that the hyperspectral targets equipped by the calibration field are well suitable for air-borne multispectral load in-flight calibration. The calibration result is reliable and could be used in the retrieval of geophysical parameters.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(12): 3423-8, 2011 Dec.
Artículo en Chino | MEDLINE | ID: mdl-22295809

RESUMEN

Polarized reflectance is influenced by such factors as its physical and chemical properties, the viewing geometry composed of light incident zenith, viewing zenith and viewing azimuth relative to light incidence, surface roughness and texture, surface density, detection wavelengths, polarization phase angle and so on. In the present paper, the influence of surface roughness on the degree of polarization (DOP) of biotite plagioclase gneiss varying with viewing angle was inquired and analyzed quantitatively. The polarized spectra were measured by ASD FS3 spectrometer on the goniometer located in Northeast Normal University. When the incident zenith angle was fixed at 50 degrees, it was showed that on the rock surfaces with different roughness, in the specular reflection direction, the DOP spectrum within 350-2500 nm increased to the highest value first, and then began to decline varying with viewing zenith angle from 0 degree to 80 degrees. The characterized band (520 +/- 10) nm was picked out for further analysis. The correlation analysis between the peak DOP value of zenith and surface roughness showed that they are in a power function relationship, with the regression equation: y = 0.604x(-0.297), R2 = 0.985 4. The correlation model of the angle where the peak is in and the surface roughness is y = 3.4194x + 51.584, y < 90 degrees , R2 = 0.8177. With the detecting azimuth farther away from 180 degrees azimuth where the maximum DOP exists, the DOP lowers gradually and tends to 0. In the detection azimuth 180 dgrees , the correlation analysis between the peak values of DOP on the (520 =/- 10) nm band for five rocks and their surface roughness indicates a power function, with the regression equation being y = 0.5822x(-0.333), R2 = 0.9843. F tests of the above regression models indicate that the peak value and its corresponding viewing angle correlate much with surface roughness. The study provides a theoretical base for polarization remote sensing, and impels the rock and city architecture discrimination and minerals mapping.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...