Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Neuroscientist ; 28(2): 163-179, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33089762

RESUMEN

Evidence from preclinical and clinical research suggest that neuromodulation technologies can facilitate the sublesional spinal networks, isolated from supraspinal commands after spinal cord injury (SCI), by reestablishing the levels of excitability and enabling descending motor signals via residual connections. Herein, we evaluate available evidence that sublesional and supralesional spinal circuits could form a translesional spinal network after SCI. We further discuss evidence of translesional network reorganization after SCI in the presence of sensory inputs during motor training. In this review, we evaluate potential mechanisms that underlie translesional circuitry reorganization during neuromodulation and rehabilitation in order to enable motor functions after SCI. We discuss the potential of neuromodulation technologies to engage various components that comprise the translesional network, their functional recovery after SCI, and the implications of the concept of translesional network in development of future neuromodulation, rehabilitation, and neuroprosthetics technologies.


Asunto(s)
Traumatismos de la Médula Espinal , Médula Espinal , Humanos , Recuperación de la Función
2.
J Clin Med ; 10(21)2021 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-34768418

RESUMEN

Transcutaneous (TSS) and epidural spinal stimulation (ESS) are electrophysiological techniques that have been used to investigate the interactions between exogenous electrical stimuli and spinal sensorimotor networks that integrate descending motor signals with afferent inputs from the periphery during motor tasks such as standing and stepping. Recently, pilot-phase clinical trials using ESS and TSS have demonstrated restoration of motor functions that were previously lost due to spinal cord injury (SCI). However, the spinal network interactions that occur in response to TSS or ESS pulses with spared descending connections across the site of SCI have yet to be characterized. Therefore, we examined the effects of delivering TSS or ESS pulses to the lumbosacral spinal cord in nine individuals with chronic SCI. During low-frequency stimulation, participants were instructed to relax or attempt maximum voluntary contraction to perform full leg flexion while supine. We observed similar lower-extremity neuromusculature activation during TSS and ESS when performed in the same participants while instructed to relax. Interestingly, when participants were instructed to attempt lower-extremity muscle contractions, both TSS- and ESS-evoked motor responses were significantly inhibited across all muscles. Participants with clinically complete SCI tested with ESS and participants with clinically incomplete SCI tested with TSS demonstrated greater ability to modulate evoked responses than participants with motor complete SCI tested with TSS, although this was not statistically significant due to a low number of subjects in each subgroup. These results suggest that descending commands combined with spinal stimulation may increase activity of inhibitory interneuronal circuitry within spinal sensorimotor networks in individuals with SCI, which may be relevant in the context of regaining functional motor outcomes.

3.
NPJ Regen Med ; 6(1): 66, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-34671050

RESUMEN

Here, we report the effect of newly regenerated axons via scaffolds on reorganization of spinal circuitry and restoration of motor functions with epidural electrical stimulation (EES). Motor recovery was evaluated for 7 weeks after spinal transection and following implantation with scaffolds seeded with neurotrophin producing Schwann cell and with rapamycin microspheres. Combined treatment with scaffolds and EES-enabled stepping led to functional improvement compared to groups with scaffold or EES, although, the number of axons across scaffolds was not different between groups. Re-transection through the scaffold at week 6 reduced EES-enabled stepping, still demonstrating better performance compared to the other groups. Greater synaptic reorganization in the presence of regenerated axons was found in group with combined therapy. These findings suggest that newly regenerated axons through cell-containing scaffolds with EES-enabled motor training reorganize the sub-lesional circuitry improving motor recovery, demonstrating that neuroregenerative and neuromodulatory therapies cumulatively enhancing motor function after complete SCI.

4.
Mayo Clin Proc ; 96(6): 1426-1437, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33678411

RESUMEN

OBJECTIVE: To provide precise description of the dorsal and ventral roots orientation along with the main spinal cord anatomical measurements and their segment-specific variations. PATIENTS AND METHODS: We collected and analyzed the measurements of the spines, spinal cords, and dorsal and ventral roots (C2-L5) of nine adult cadavers (five males and four females). RESULTS: This study for the first time provides analysis of the dorsal and ventral roots orientation along with spinal cord anatomical measurements and their segment-specific distribution. The results of this study showed less variability in rostral root angles compared with the caudal. Dorsal and ventral rootlets were oriented mostly perpendicular to the spinal cord at the cervical level and had more parallel orientation to the spinal cord at the thoracic and lumbar segments. The number of rootlets per root was greatest at dorsal cervical and lumbar segments. Spinal cord transverse diameter and width of the dorsal columns were largest at cervical segments. The strongest correlation between the spinal cord and vertebrae structures was found between the length of intervertebral foramen to rostral rootlet distance and vertebral bone length. CONCLUSION: These results demonstrate consistent variation in spinal cord anatomical features across all tested subjects. The results of this study can be used to locate spinal roots and main spinal cord landmarks based on bone marks on computed tomography or X-rays. These results could improve stereotactic surgical procedures and electrode positioning for neuromodulation procedures.


Asunto(s)
Médula Espinal/anatomía & histología , Raíces Nerviosas Espinales/anatomía & histología , Anciano de 80 o más Años , Puntos Anatómicos de Referencia/anatomía & histología , Vértebras Cervicales , Femenino , Humanos , Vértebras Lumbares , Masculino , Vértebras Torácicas
5.
Front Rehabil Sci ; 2: 757828, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-36188812

RESUMEN

Background: Neuromodulation using epidural electrical stimulation (EES) has shown functional restoration in humans with chronic spinal cord injury (SCI). EES during body weight supported treadmill training (BWSTT) enhanced stepping performance in clinical trial participants with paraplegia. Unfortunately, tools are lacking in availability to quantify clinician assistance during BWSTT with and without EES. Force sensitive resistors (FSRs) have previously quantified clinician assistance during static standing; however, dynamic tasks have not been addressed. Objective: To determine the validity of FSRs in measurements of force and duration to quantify clinician assistance and participant progression during BWSTT with EES in participants with SCI. Design: A feasibility study to determine the effectiveness of EES to restore function in individuals with SCI. Methods: Two male participants with chronic SCI were enrolled in a pilot phase clinical trial. Following implantation of an EES system in the lumbosacral spinal cord, both participants underwent 12 months of BWSTT with EES. At monthly intervals, FSRs were positioned on participants' knees to quantity forces applied by clinicians to achieve appropriate mechanics of stepping during BWSTT. The FSRs were validated on the benchtop using a leg model instrumented with a multiaxial load cell as the gold standard. The outcomes included clinician-applied force duration measured by FSR sensors and changes in applied forces indicating progression over the course of rehabilitation. Results: The force sensitive resistors validation revealed a proportional bias in their output. Loading required for maximal assist training exceeded the active range of the FSRs but were capable of capturing changes in clinician assist levels. The FSRs were also temporally responsive which increased utility for accurately assessing training contact time. The FSRs readings were able to capture independent stance for both participants by study end. There was minimal to no applied force bilaterally for participant 1 and unilaterally for participant 2. Conclusions: Clinician assistance applied at the knees as measured through FSRs during dynamic rehabilitation and EES (both on and off) effectively detected point of contact and duration of forces; however, it lacks accuracy of magnitude assessment. The reduced contact time measured through FSRs related to increased stance duration, which objectively identified independence in stepping during EES-enabled BWSTT following SCI.

6.
Front Neurosci ; 14: 552, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32655351

RESUMEN

OBJECTIVE: In this study, we evaluated the role of residual supraspinal and afferent signaling and their convergence on the sublesional spinal network in subject diagnosed with complete paralysis (AIS-A). METHODS: A combination of electrophysiologic techniques with positional changes and subject-driven reinforcement maneuvers was implemented in this study. Electrical stimulation was applied transcutaneously at the T9-L2 vertebra levels and the spinal cord motor evoked potentials (SEMP) were recorded from leg muscles. To test the influence of positional changes, the subject was placed in (i) supine, (ii) upright with partial body weight bearing and (iii) vertically suspended without body weight bearing positions. RESULTS: Increase in amplitude of SEMP was observed during transition from supine to upright position, supporting the role of sensory input in lumbosacral network excitability. Additionally, amplitudes of SEMP were facilitated during reinforcement maneuvers, indicating a supralesional influence on sub-lesional network. After initial assessment, subject underwent rehabilitation therapy with following electrophysiological testing that reviled facilitation of SEMP. CONCLUSION: These results demonstrate that combination of electrophysiological techniques with positional and reinforcement maneuvers can add to the diagnostics of discomplete SCI. These findings also support an idea that integration of supraspinal and afferent information on sub-lesional circuitry plays a critical role in facilitation of spinal sensorimotor network in discomplete SCI.

7.
Front Syst Neurosci ; 14: 590231, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33584209

RESUMEN

Background: Regaining control of movement following a spinal cord injury (SCI) requires utilization and/or functional reorganization of residual descending, and likely ascending, supraspinal sensorimotor pathways, which may be facilitated via task-specific training through body weight supported treadmill (BWST) training. Recently, epidural electrical stimulation (ES) combined with task-specific training demonstrated independence of standing and stepping functions in individuals with clinically complete SCI. The restoration of these functions may be dependent upon variables such as manipulation of proprioceptive input, ES parameter adjustments, and participant intent during step training. However, the impact of each variable on the degree of independence achieved during BWST stepping remains unknown. Objective: To describe the effects of descending intentional commands and proprioceptive inputs, specifically body weight support (BWS), on lower extremity motor activity and vertical ground reaction forces (vGRF) during ES-enabled BWST stepping in humans with chronic sensorimotor complete SCI. Furthermore, we describe perceived changes in the level of assistance provided by clinicians when intent and BWS are modified. Methods: Two individuals with chronic, mid thoracic, clinically complete SCI, enrolled in an IRB and FDA (IDE G150167) approved clinical trial. A 16-contact electrode array was implanted in the epidural space between the T11-L1 vertebral regions. Lower extremity motor output and vertical ground reaction forces were obtained during clinician-assisted ES-enabled treadmill stepping with BWS. Consecutive steps were achieved during various experimentally-controlled conditions, including intentional participation and varied BWS (60% and 20%) while ES parameters remain unchanged. Results: During ES-enabled BWST stepping, the knee extensors exhibited an increase in motor activation during trials in which stepping was passive compared to active or during trials in which 60% BWS was provided compared to 20% BWS. As a result of this increased motor activation, perceived clinician assistance increased during the transition from stance to swing. Intentional participation and 20% BWS resulted in timely and purposeful activation of the lower extremities muscles, which improved independence and decreased clinician assistance. Conclusion: Maximizing participant intention and optimizing proprioceptive inputs through BWS during ES-enabled BWST stepping may facilitate greater independence during BWST stepping for individuals with clinically complete SCI. Clinical Trial Registration: ClinicalTrials.gov identifier: NCT02592668.

8.
J Neurophysiol ; 122(5): 2111-2118, 2019 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-31553681

RESUMEN

Transcutaneous spinal stimulation (TSS), a noninvasive technique to modulate sensorimotor circuitry within the spinal cord, has been shown to enable a wide range of functions that were thought to be permanently impaired in humans with spinal cord injury. However, the extent to which TSS can be used to target specific mediolateral spinal cord circuitry remains undefined. We tested the hypothesis that TSS applied unilaterally to the skin ~2 cm lateral to the midline of the lumbosacral spine selectively activates ipsilateral spinal sensorimotor circuitry, resulting in ipsilateral activation of downstream lower extremity neuromusculature. TSS cathodes and anodes were positioned lateral from the midline of the spine in 15 healthy subjects while supine, and the timing of TSS pulses was synchronized to recordings of lower extremity muscle activity and force. At motor threshold, left and right TSS-evoked muscle activity was significantly higher in the ipsilateral leg compared with contralateral recordings from the same muscles. Similarly, we observed a significant increase in force production in the ipsilateral leg compared with the contralateral leg. Delivery of paired TSS pulses, during which an initial stimulus was applied to one side of the spinal cord and 50 ms later a second stimulus was applied to the contralateral side, revealed that ipsilateral leg muscle responses decreased following the initial stimulus, whereas contralateral muscle responses did not decrease, indicating side-specific activation of lateral spinal sensorimotor circuitry. Our results indicate TSS can selectively engage ipsilateral neuromusculature via lumbosacral sensorimotor networks responsible for lower extremity function in healthy humans.NEW & NOTEWORTHY We demonstrate the selectivity of transcutaneous spinal stimulation (TSS), which has been shown to enable function in humans with chronic paralysis. Specifically, we demonstrate that TSS applied to locations lateral to the spinal cord can selectively activate ipsilateral spinal sensorimotor networks. We quantified lumbosacral spinal network activity by recording lower extremity muscle electromyography and force. Our results suggest lumbosacral TSS engages side-specific spinal sensorimotor networks associated with ipsilateral lower extremity function in humans.


Asunto(s)
Lateralidad Funcional , Estimulación de la Médula Espinal/métodos , Médula Espinal/fisiología , Adulto , Potenciales Evocados Motores , Femenino , Humanos , Región Lumbosacra/fisiología , Masculino , Músculo Esquelético/fisiología , Estimulación Eléctrica Transcutánea del Nervio/métodos
9.
Neuromodulation ; 22(3): 244-252, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30840354

RESUMEN

BACKGROUND: Traumatic spinal cord injury (SCI) disrupts signaling pathways between the brain and spinal networks below the level of injury. In cases of severe SCI, permanent loss of sensorimotor and autonomic function can occur. The standard of care for severe SCI uses compensation strategies to maximize independence during activities of daily living while living with chronic SCI-related dysfunctions. Over the past several years, the research field of spinal neuromodulation has generated promising results that hold potential to enable recovery of functions via epidural electrical stimulation (EES). METHODS: This review provides a historical account of the translational research efforts that led to the emergence of EES of the spinal cord to enable intentional control of motor functions that were lost after SCI. We also highlight the major limitations associated with EES after SCI and propose future directions of spinal neuromodulation research. RESULTS: Multiple, independent studies have demonstrated return of motor function via EES in individuals with chronic SCI. These enabled motor functions include intentional, controlled movement of previously paralyzed extremities, independent standing and stepping, and increased grip strength. In addition, improvements in cardiovascular health, respiratory function, body composition, and urologic function have been reported. CONCLUSIONS: EES holds promise to enable functions thought to be permanently lost due to SCI. However, EES is currently restricted to scientific investigation in humans with SCI and requires further validation of factors such as safety and efficacy before clinical translation.


Asunto(s)
Espacio Epidural/fisiología , Red Nerviosa/fisiología , Desempeño Psicomotor/fisiología , Recuperación de la Función/fisiología , Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal/tendencias , Humanos , Corteza Sensoriomotora/fisiología , Médula Espinal/fisiología , Traumatismos de la Médula Espinal/fisiopatología , Estimulación de la Médula Espinal/métodos
10.
J Neurotrauma ; 36(9): 1451-1460, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30430902

RESUMEN

Epidural electrical stimulation (EES) of the spinal cord has been shown to restore function after spinal cord injury (SCI). Characterization of EES-evoked motor responses has provided a basic understanding of spinal sensorimotor network activity related to EES-enabled motor activity of the lower extremities. However, the use of EES-evoked motor responses to guide EES system implantation over the spinal cord and their relation to post-operative EES-enabled function in humans with chronic paralysis attributed to SCI has yet to be described. Herein, we describe the surgical and intraoperative electrophysiological approach used, followed by initial EES-enabled results observed in 2 human subjects with motor complete paralysis who were enrolled in a clinical trial investigating the use of EES to enable motor functions after SCI. The 16-contact electrode array was initially positioned under fluoroscopic guidance. Then, EES-evoked motor responses were recorded from select leg muscles and displayed in real time to determine electrode array proximity to spinal cord regions associated with motor activity of the lower extremities. Acceptable array positioning was determined based on achievement of selective proximal or distal leg muscle activity, as well as bilateral muscle activation. Motor response latencies were not significantly different between intraoperative recordings and post-operative recordings, indicating that array positioning remained stable. Additionally, EES enabled intentional control of step-like activity in both subjects within the first 5 days of testing. These results suggest that the use of EES-evoked motor responses may guide intraoperative positioning of epidural electrodes to target spinal cord circuitry to enable motor functions after SCI.


Asunto(s)
Electrodos Implantados , Monitorización Neurofisiológica Intraoperatoria/métodos , Procedimientos Neuroquirúrgicos/métodos , Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal/métodos , Adulto , Electromiografía/métodos , Espacio Epidural , Potenciales Evocados Motores/fisiología , Humanos , Locomoción/fisiología , Región Lumbosacra , Masculino , Parálisis/etiología , Parálisis/fisiopatología , Parálisis/cirugía , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/fisiopatología
11.
Nat Med ; 24(12): 1942, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30353100

RESUMEN

In the version of this article originally published, Dimitry G. Sayenko's affiliations were not correct. The following affiliation for this author was missing: Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, Houston, TX, USA. This affiliation has been added for the author, and the rest of the affiliations have been renumbered accordingly. The error has been corrected in the HTML and PDF versions of this article.

12.
Nat Med ; 24(11): 1677-1682, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30250140

RESUMEN

Spinal sensorimotor networks that are functionally disconnected from the brain because of spinal cord injury (SCI) can be facilitated via epidural electrical stimulation (EES) to restore robust, coordinated motor activity in humans with paralysis1-3. Previously, we reported a clinical case of complete sensorimotor paralysis of the lower extremities in which EES restored the ability to stand and the ability to control step-like activity while side-lying or suspended vertically in a body-weight support system (BWS)4. Since then, dynamic task-specific training in the presence of EES, termed multimodal rehabilitation (MMR), was performed for 43 weeks and resulted in bilateral stepping on a treadmill, independent from trainer assistance or BWS. Additionally, MMR enabled independent stepping over ground while using a front-wheeled walker with trainer assistance at the hips to maintain balance. Furthermore, MMR engaged sensorimotor networks to achieve dynamic performance of standing and stepping. To our knowledge, this is the first report of independent stepping enabled by task-specific training in the presence of EES by a human with complete loss of lower extremity sensorimotor function due to SCI.


Asunto(s)
Red Nerviosa/fisiopatología , Paraplejía/rehabilitación , Traumatismos de la Médula Espinal/rehabilitación , Estimulación Eléctrica Transcutánea del Nervio , Adulto , Estimulación Eléctrica , Electromiografía , Humanos , Masculino , Actividad Motora/fisiología , Músculo Esquelético/fisiopatología , Parálisis/fisiopatología , Parálisis/rehabilitación , Paraplejía/fisiopatología , Traumatismos de la Médula Espinal/fisiopatología
13.
Front Neuroanat ; 11: 82, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29075183

RESUMEN

In this study, the neuroanatomy of the swine lumbar spinal cord, particularly the spatial orientation of dorsal roots was correlated to the anatomical landmarks of the lumbar spine and to the magnitude of motor evoked potentials during epidural electrical stimulation (EES). We found that the proximity of the stimulating electrode to the dorsal roots entry zone across spinal segments was a critical factor to evoke higher peak-to-peak motor responses. Positioning the electrode close to the dorsal roots produced a significantly higher impact on motor evoked responses than rostro-caudal shift of electrode from segment to segment. Based on anatomical measurements of the lumbar spine and spinal cord, significant differences were found between L1-L4 to L5-L6 segments in terms of spinal cord gross anatomy, dorsal roots and spine landmarks. Linear regression analysis between intersegmental landmarks was performed and L2 intervertebral spinous process length was selected as the anatomical reference in order to correlate vertebral landmarks and the spinal cord structures. These findings present for the first time, the influence of spinal cord anatomy on the effects of epidural stimulation and the role of specific orientation of electrodes on the dorsal surface of the dura mater in relation to the dorsal roots. These results are critical to consider as spinal cord neuromodulation strategies continue to evolve and novel spinal interfaces translate into clinical practice.

14.
Mayo Clin Proc ; 92(9): 1401-1414, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28781176

RESUMEN

Spinal cord injury (SCI) is a complex and devastating condition characterized by disruption of descending, ascending, and intrinsic spinal circuitry resulting in chronic neurologic deficits. In addition to limb and trunk sensorimotor deficits, SCI can impair autonomic neurocircuitry such as the motor networks that support respiration and cough. High cervical SCI can cause complete respiratory paralysis, and even lower cervical or thoracic lesions commonly result in partial respiratory impairment. Although electrophrenic respiration can restore ventilator-independent breathing in select candidates, only a small subset of affected individuals can benefit from this technology at this moment. Over the past decades, spinal cord stimulation has shown promise for augmentation and recovery of neurologic function including motor control, cough, and breathing. The present review discusses the challenges and potentials of spinal cord stimulation for restoring respiratory function by overcoming some of the limitations of conventional respiratory functional electrical stimulation systems.


Asunto(s)
Recuperación de la Función/fisiología , Trastornos Respiratorios/terapia , Traumatismos de la Médula Espinal/rehabilitación , Estimulación de la Médula Espinal/métodos , Estimulación Eléctrica Transcutánea del Nervio/métodos , Humanos , Trastornos Respiratorios/etiología , Traumatismos de la Médula Espinal/complicaciones
15.
Front Hum Neurosci ; 11: 144, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28400726

RESUMEN

Spinal cord injury (SCI) remains a debilitating condition for which there is no cure. In addition to loss of somatic sensorimotor functions, SCI is also commonly associated with impairment of autonomic function. Importantly, cough dysfunction due to paralysis of expiratory muscles in combination with respiratory insufficiency can render affected individuals vulnerable to respiratory morbidity. Failure to clear sputum can aggravate both risk for and severity of respiratory infections, accounting for frequent hospitalizations and even mortality. Recently, epidural stimulation of the lower thoracic spinal cord has been investigated as novel means for restoring cough by evoking expiratory muscle contraction to generate large positive airway pressures and expulsive air flow. This review article discusses available preclinical and clinical evidence, current challenges and clinical potential of lower thoracic spinal cord stimulation (SCS) for restoring cough in individuals with SCI.

16.
Mayo Clin Proc ; 92(4): 544-554, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28385196

RESUMEN

We report a case of chronic traumatic paraplegia in which epidural electrical stimulation (EES) of the lumbosacral spinal cord enabled (1) volitional control of task-specific muscle activity, (2) volitional control of rhythmic muscle activity to produce steplike movements while side-lying, (3) independent standing, and (4) while in a vertical position with body weight partially supported, voluntary control of steplike movements and rhythmic muscle activity. This is the first time that the application of EES enabled all of these tasks in the same patient within the first 2 weeks (8 stimulation sessions total) of EES therapy.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Músculo Esquelético/fisiopatología , Paraplejía , Traumatismos de la Médula Espinal , Médula Espinal/fisiopatología , Adulto , Electromiografía/métodos , Humanos , Masculino , Paraplejía/diagnóstico , Paraplejía/etiología , Paraplejía/fisiopatología , Postura/fisiología , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/fisiopatología , Traumatismos de la Médula Espinal/terapia , Análisis y Desempeño de Tareas , Resultado del Tratamiento , Caminata/fisiología
17.
Spine (Phila Pa 1976) ; 41(13): E806-E813, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-26679880

RESUMEN

STUDY DESIGN: Laboratory/animal-based proof of principle study. OBJECTIVE: To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. SUMMARY OF BACKGROUND DATA: Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. METHODS: System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. RESULTS: The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ±â€Š0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. CONCLUSION: We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Electrodos Implantados , Imagen por Resonancia Magnética/métodos , Médula Espinal/diagnóstico por imagen , Técnicas Estereotáxicas , Animales , Imagen por Resonancia Magnética/instrumentación , Masculino , Microelectrodos , Traumatismos de la Médula Espinal/diagnóstico por imagen , Traumatismos de la Médula Espinal/terapia , Técnicas Estereotáxicas/instrumentación , Porcinos
18.
Tissue Eng Part A ; 21(13-14): 2099-114, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25891264

RESUMEN

Positively charged oligo[poly(ethylene glycol) fumarate] (OPF+) scaffolds loaded with Schwann cells bridge spinal cord injury (SCI) lesions and support axonal regeneration in rat. The regeneration achieved is not sufficient for inducing functional recovery. Attempts to increase regeneration would benefit from understanding the effects of the scaffold and transplanted cells on lesion environment. We conducted morphometric and stereological analysis of lesions in rats implanted with OPF+ scaffolds with or without loaded Schwann cells 1, 2, 3, 4, and 8 weeks after thoracic spinal cord transection. No differences were found in collagen scarring, cyst formation, astrocyte reactivity, myelin debris, or chondroitin sulfate proteoglycan (CSPG) accumulation. However, when scaffold-implanted animals were compared with animals with transection injuries only, these barriers to regeneration were significantly reduced, accompanied by increased activated macrophages/microglia. This distinctive and regeneration permissive tissue reaction to scaffold implantation was independent of Schwann cell transplantation. Although the tissue reaction was beneficial in the short term, we observed a chronic fibrotic host response, resulting in scaffolds surrounded by collagen at 8 weeks. This study demonstrates that an appropriate biomaterial scaffold improves the environment for regeneration. Future targeting of the host fibrotic response may allow increased axonal regeneration and functional recovery.


Asunto(s)
Fumaratos/farmacología , Polietilenglicoles/farmacología , Implantación de Prótesis , Traumatismos de la Médula Espinal/patología , Traumatismos de la Médula Espinal/terapia , Andamios del Tejido/química , Animales , Astrocitos/efectos de los fármacos , Astrocitos/metabolismo , Proteínas de Unión al Calcio/metabolismo , Femenino , Proteína Ácida Fibrilar de la Glía/metabolismo , Proteínas Fluorescentes Verdes/metabolismo , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Proteínas de Microfilamentos/metabolismo , Microglía/efectos de los fármacos , Microglía/metabolismo , Proteína Básica de Mielina/metabolismo , Fenotipo , Proteoglicanos/metabolismo , Ratas Sprague-Dawley , Células de Schwann/citología , Células de Schwann/efectos de los fármacos , Células de Schwann/trasplante , Factores de Tiempo
19.
Mayo Clin Proc ; 90(2): 300-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25659246

RESUMEN

Spinal cord injury can be defined as a loss of communication between the brain and the body due to disrupted pathways within the spinal cord. Although many promising molecular strategies have emerged to reduce secondary injury and promote axonal regrowth, there is still no effective cure, and recovery of function remains limited. Functional electrical stimulation (FES) represents a strategy developed to restore motor function without the need for regenerating severed spinal pathways. Despite its technological success, however, FES has not been widely integrated into the lives of spinal cord injury survivors. In this review, we briefly discuss the limitations of existing FES technologies. Additionally, we discuss how optogenetics, a rapidly evolving technique used primarily to investigate select neuronal populations within the brain, may eventually be used to replace FES as a form of therapy for functional restoration after spinal cord injury.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Optogenética/métodos , Traumatismos de la Médula Espinal/terapia , Humanos , Médula Espinal/fisiopatología
20.
J Neurosurg ; 123(1): 232-242, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25479124

RESUMEN

OBJECT: Despite a promising outlook, existing intraspinal microstimulation (ISMS) techniques for restoring functional motor control after spinal cord injury are not yet suitable for use outside a controlled laboratory environment. Thus, successful application of ISMS therapy in humans will require the use of versatile chronic neurostimulation systems. The objective of this study was to establish proof of principle for wireless control of ISMS to evoke controlled motor function in a rodent model of complete spinal cord injury. METHODS: The lumbar spinal cord in each of 17 fully anesthetized Sprague-Dawley rats was stimulated via ISMS electrodes to evoke hindlimb function. Nine subjects underwent complete surgical transection of the spinal cord at the T-4 level 7 days before stimulation. Targeting for both groups (spinalized and control) was performed under visual inspection via dorsal spinal cord landmarks such as the dorsal root entry zone and the dorsal median fissure. Teflon-insulated stimulating platinum-iridium microwire electrodes (50 µm in diameter, with a 30- to 60-µm exposed tip) were implanted within the ventral gray matter to an approximate depth of 1.8 mm. Electrode implantation was performed using a free-hand delivery technique (n = 12) or a Kopf spinal frame system (n = 5) to compare the efficacy of these 2 commonly used targeting techniques. Stimulation was controlled remotely using a wireless neurostimulation control system. Hindlimb movements evoked by stimulation were tracked via kinematic markers placed on the hips, knees, ankles, and paws. Postmortem fixation and staining of the spinal cord tissue were conducted to determine the final positions of the stimulating electrodes within the spinal cord tissue. RESULTS: The results show that wireless ISMS was capable of evoking controlled and sustained activation of ankle, knee, and hip muscles in 90% of the spinalized rats (n = 9) and 100% of the healthy control rats (n = 8). No functional differences between movements evoked by either of the 2 targeting techniques were revealed. However, frame-based targeting required fewer electrode penetrations to evoke target movements. CONCLUSIONS: Clinical restoration of functional movement via ISMS remains a distant goal. However, the technology presented herein represents the first step toward restoring functional independence for individuals with chronic spinal cord injury.


Asunto(s)
Estimulación Eléctrica/métodos , Parálisis/terapia , Traumatismos de la Médula Espinal/terapia , Médula Espinal/fisiopatología , Tecnología Inalámbrica , Animales , Potenciales Evocados Motores/fisiología , Femenino , Microelectrodos , Modelos Animales , Movimiento/fisiología , Músculo Esquelético/inervación , Músculo Esquelético/fisiología , Parálisis/fisiopatología , Ratas , Ratas Sprague-Dawley , Traumatismos de la Médula Espinal/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...