Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
1.
Phys Imaging Radiat Oncol ; 31: 100614, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39157294

RESUMEN

Background and purpose: Oxygen dynamics may be important for the tissue-sparing effect observed at ultra-high dose rates (FLASH sparing effect). This study investigated the correlation between local instantaneous dose rate and radiation-induced oxygen pressure reduction during proton pencil beam scanning (PBS) irradiations of a sample and quantified the oxygen consumption g-value. Materials and methods: A 0.2 ml phosphorescent sample (1 µM PtG4 Oxyphor probe in saline) was irradiated with a 244 MeV proton PBS beam. Four irradiations were performed with variations of a PBS spot pattern with 5 × 7 spots. During irradiation, the partial oxygen pressure (pO2) was measured with 4.5 Hz temporal resolution with a phosphorometer (Oxyled) that optically excited the probe and recorded the subsequently emitted light. A calibration was performed to calculate the pO2 level from the measured phosphorescence lifetime. A fiber-coupled scintillator simultaneously measured the instantaneous dose rate in the sample with 50 kHz sampling rate. The oxygen consumption g-value was determined on a spot-by-spot level and using the total pO2 change for full spot pattern irradiation. Results: A high correlation was found between the local instantaneous dose rate and pO2 reduction rate, with a correlation coefficient of 0.96-0.99. The g-vales were 0.18 ± 0.01 mmHg/Gy on a spot-by-spot level and 0.17 ± 0.01 mmHg/Gy for full spot pattern irradiation. Conclusions: The pO2 reduction rate was directly related to the local instantaneous dose rate per delivered spot in PBS deliveries. The methodology presented here can be applied to irradiation at ultra-high dose rates with modifications in the experimental setup.

2.
Front Oncol ; 14: 1427667, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39026976

RESUMEN

Objective: A favorable effect of ultra-high dose rate (FLASH) radiation on normal tissue-sparing has been indicated in several preclinical studies. In these studies, the adverse effects of radiation damage were reduced without compromising tumor control. Most studies of proton FLASH investigate these effects within the entrance of a proton beam. However, the real advantage of proton therapy lies in the Spread-out Bragg Peak (SOBP), which allows for giving a high dose to a target with a limited dose to healthy tissue at the entrance of the beam. Therefore, a clinically relevant investigation of the FLASH effect would be of healthy tissues within a SOBP. Our study quantified the tissue-sparing effect of FLASH radiation on acute and late toxicity within an SOBP in a murine model. Material/Methods: Radiation-induced damage was assessed for acute and late toxicity in the same mice following irradiation with FLASH (Field dose rate of 60 Gy/s) or conventional (CONV, 0.34 Gy/s) dose rates. The right hindleg of unanesthetized female CDF1 mice was irradiated with single-fraction doses between 19.9-49.7 Gy for CONV and 30.4-65.9 Gy for FLASH with 5-8 mice per dose. The leg was placed in the middle of a 5 cm SOBP generated from a mono-energetic beam using a 2D range modulator. Acute skin toxicity quantified by hair loss, moist desquamation and toe separation was monitored daily within 29 days post-treatment. Late toxicity of fibrotic development measured by leg extendibility was monitored biweekly until 30 weeks post-treatment. Results: Comparison of acute skin toxicity following radiation indicated a tissue-sparing effect of FLASH compared to conventional single-fraction radiation with a mean protection ratio of 1.40 (1.35-1.46). Fibrotic development similarly indicated normal tissue sparing with a 1.18 (1.17-1.18) protection ratio. The acute skin toxicity tissue sparing was similar to data from entrance-beam irradiations of Sørensen et al. (4). Conclusion: Full dose-response curves for acute and late toxicity after CONV and FLASH radiation were obtained. Radiation within the SOBP retains the normal-tissue-sparing effect of FLASH with a dose-modifying factor of 40% for acute skin damage and 18% for fibrotic development.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39041053

RESUMEN

Background: Physicians manage multiple obligations, providing best-practice treatment and patient- centred care in the standard treatment pathway while contributing to clinical trials simultaneously. These multifaceted responsibilities may introduce barriers and dilemmas to clinical trial execution, potentially impacting the clinical trial decision- making process. This study explores physicians' barriers and dilemmas in executing clinical trials and the impact on clinical trial decision-making. Method: Qualitative semi-structured interviews were conducted with experienced oncologists. Moreover, participant observations were performed during clinical encounters involving discussions about clinical trials. The analysis followed a structured approach: (1) transcription of data, (2) inductive text coding, (3) exploration of patterns, and (4) interpretation, leading to the results. The results were discussed and validated by the study participants. Results: The results comprise (1) a description of the clinical practice, which presents the setting of clinical trial execution; (2) results regarding physicians' barriers and dilemmas in executing clinical trials, leading to (3) the impact on clinical trial decision- making. The results involve barriers to time constraints for clinical trial tasks, dilemmas emerging from trial requirements or deviations from standard guidelines, and challenges with providing sufficient trial communication and adequate decision-making support, balancing between a paternalistic approach and respecting patient autonomy. Conclusion: The demanding obligations of clinical practice constitute a complex setting for executing clinical trials, resulting in numerous barriers and dilemmas that impact the decision-making process in clinical trials. The study emphasises the need for tailored clinical trial decision-making interventions to facilitate supportive, informed, and non-directive clinical trial decision-making.

4.
Int J Radiat Oncol Biol Phys ; 120(1): 265-275, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38750904

RESUMEN

PURPOSE: Preclinical studies have shown a preferential normal tissue sparing effect of FLASH radiation therapy with ultra-high dose rates. The aim of the present study was to use a murine model of acute skin toxicity to investigate the biologic effect of varying dose rates, time structure, and introducing pauses in the dose delivery. METHODS AND MATERIALS: The right hind limbs of nonanaesthetized mice were irradiated in the entrance plateau of a pencil beam scanning proton beam with 39.3 Gy. Experiment 1 was with varying field dose rates (0.7-80 Gy/s) without repainting, experiment 2 was with varying field dose rates (0.37-80 Gy/s) with repainting, and in experiment 3, the dose was split into 2, 3, 4, or 6 identical deliveries with 2-minute pauses. In total, 320 mice were included, with 6 to 25 mice per group. The endpoints were skin toxicity of different levels up to 25 days after irradiation. RESULTS: The dose rate50, which is the dose rate to induce a response in 50% of the animals, depended on the level of skin toxicity, with the higher toxicity levels displaying a FLASH effect at 0.7-2 Gy/s. Repainting resulted in higher toxicity for the same field dose rate. Splitting the dose into 2 deliveries reduced the FLASH effect, and for 3 or more deliveries, the FLASH effect was almost abolished for lower grades of toxicity. CONCLUSIONS: The dose rate that induced a FLASH effect varied for different skin toxicity levels, which are characterized by a differing degree of sensitivity to radiation dosage. Conclusions on a threshold for the dose rate needed to obtain a FLASH effect can therefore be influenced by the dose sensitivity of the used endpoint. Splitting the total dose into more deliveries compromised the FLASH effect. This can have an impact for fractionation as well as for regions where 2 or more FLASH fields overlap within the same treatment session.


Asunto(s)
Terapia de Protones , Piel , Animales , Ratones , Piel/efectos de la radiación , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Relación Dosis-Respuesta en la Radiación , Femenino , Factores de Tiempo , Miembro Posterior/efectos de la radiación , Traumatismos Experimentales por Radiación , Dosificación Radioterapéutica
5.
Radiother Oncol ; 196: 110284, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38636711

RESUMEN

INTRODUCTION: Treatment planning using a five-millimetre geometrical margin from GTV to high-dose CTV (CTV1) has been used in DAHANCA treatment centres since 2013. We aimed to evaluate changes in CTV1 volumes, local control (LC), and recurrence pattern after the implementation of five-millimetre geometrical margins nationally. MATERIALS AND METHODS: 1,948 patients with pharyngeal, and laryngeal squamous cell carcinomas completed definitive IMRT-based treatment in 2010-2012 and 2013-2015 in three centres. The patient-specific margin was calculated as median surface distance from primary tumour GTV (GTV-T) to CTV1. Radiologically verified local recurrences were analysed using a centre of mass (COM) of the delineated recurrence volume, measuring the shortest distance between COM to GTV-T and CTV1 boundaries. RESULTS: Median GTV-CTV1 was 0.9 (0.0-0.97) and 0.47 cm (0.4-0.5) for 2010-2012 and 2013-2015, respectively. Median CTV1 changed in three centres from 76, 28, 42 cm3 to 61, 53, 62 cm3 for 2010-2012 and 2013-2015, respectively. Local failures occurred at 247 patients during first three years after radiotherapy. The 3-year LC rate for 2010-2012 and 2013-2015 was 0.84 and 0.87 (p = 0.06). Out of 146 radiology-verified analysable local recurrences, 102 (69.9%) were inside the CTV1. In 74.6% and 91% of cases, the LRs were covered by 95% isodose in 2010-2012 and 2013-2015, respectively. CONCLUSION: DAHANCA radiotherapy guidelines based on a geometrically generated isotropic CTV1 margin led to less variation in treatment volumes and between centres than previous guidelines. The transition towards consensus GTV-CTV1 margins did not influence local tumour control. The majority of local recurrences were inside CTV1 and covered by the prescription dose.


Asunto(s)
Neoplasias Laríngeas , Recurrencia Local de Neoplasia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Masculino , Femenino , Recurrencia Local de Neoplasia/radioterapia , Persona de Mediana Edad , Anciano , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/patología , Radioterapia de Intensidad Modulada/métodos , Guías de Práctica Clínica como Asunto , Neoplasias Faríngeas/radioterapia , Neoplasias Faríngeas/patología , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/patología , Anciano de 80 o más Años , Adulto
6.
Radiother Oncol ; 196: 110293, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38653379

RESUMEN

The evidence for the value of particle therapy (PT) is still sparse. While randomized trials remain a cornerstone for robust comparisons with photon-based radiotherapy, data registries collecting real-world data can play a crucial role in building evidence for new developments. This Perspective describes how the European Particle Therapy Network (EPTN) is actively working on establishing a prospective data registry encompassing all patients undergoing PT in European centers. Several obstacles and hurdles are discussed, for instance harmonization of nomenclature and structure of technical and dosimetric data and data protection issues. A preferred approach is the adoption of a federated data registry model with transparent and agile governance to meet European requirements for data protection, transfer, and processing. Funding of the registry, especially for operation after the initial setup process, remains a major challenge.


Asunto(s)
Sistema de Registros , Humanos , Europa (Continente) , Estudios Prospectivos , Neoplasias/radioterapia , Terapia de Protones
7.
Int J Radiat Oncol Biol Phys ; 120(1): 276-286, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38462015

RESUMEN

PURPOSE: The aim of this work was to investigate the ability of a biological oxygen enhancement ratio-weighted dose, DOER, to describe acute skin toxicity variations observed in mice after proton pencil beam scanning irradiations with changing doses and beam time structures. METHODS AND MATERIALS: In five independent experiments, the right hind leg of a total of 621 CDF1 mice was irradiated previously in the entrance plateau of a pencil beam scanning proton beam. The incidence of acute skin toxicity (of level 1.5-2.0-2.5-3.0-3.5) was scored for 47 different mouse groups that mapped toxicity as function of dose for conventional and FLASH dose rate, toxicity as function of field dose rate with and without repainting, and toxicity when splitting the treatment into 1 to 6 identical deliveries separated by 2 minutes. DOER was calculated for all mouse groups using a simple oxygen kinetics model to describe oxygen depletion. The three independent model parameters (oxygen-depletion rate, oxygen-recovery rate, oxygen level without irradiation) were fitted to the experimental data. The ability of DOER to describe the toxicity variations across all experiments was investigated by comparing DOER-response curves across the five independent experiments. RESULTS: After conversion from the independent variable tested in each experiment to DOER, all five experiments had similar MDDOER50 (DOER giving 50% toxicity incidence) with standard deviations of 0.45 - 1.6 Gy for the five toxicity levels. DOER could thus describe the observed toxicity variations across all experiments. CONCLUSIONS: DOER described the varying FLASH-sparing effect observed for a wide range of conditions. Calculation of DOER for other irradiation conditions can quantitatively estimate the FLASH-sparing effect for arbitrary irradiations for the investigated murine model. With appropriate fitting parameters DOER also may be able to describe FLASH effect variations with dose and dose rate for other assays and endpoints.


Asunto(s)
Oxígeno , Terapia de Protones , Piel , Animales , Ratones , Piel/efectos de la radiación , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Traumatismos Experimentales por Radiación/prevención & control , Factores de Tiempo , Relación Dosis-Respuesta en la Radiación , Radiodermatitis/etiología , Radiodermatitis/patología , Femenino , Miembro Posterior/efectos de la radiación , Ratones Endogámicos , Protones/efectos adversos
9.
Clin Transl Radiat Oncol ; 45: 100737, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38317680

RESUMEN

Background: The role of early treatment response for patients with locally advanced non-small cell lung cancer (LA-NSCLC) treated with concurrent chemo-radiotherapy (cCRT) is unclear. The study aims to investigate the predictive value of response to induction chemotherapy (iCX) and the correlation with pattern of failure (PoF). Materials and methods: Patients with LA-NSCLC treated with cCRT were included for analyses (n = 276). Target delineations were registered from radiotherapy planning PET/CT to diagnostic PET/CT, in between which patients received iCX. Volume, sphericity, and SUVpeak were extracted from each scan. First site of failure was categorised as loco-regional (LR), distant (DM), or simultaneous LR+M (LR+M). Fine and Gray models for PoF were performed: a baseline model (including performance status (PS), stage, and histology), an image model for squamous cell carcinoma (SCC), and an image model for non-SCC. Parameters included PS, volume (VOL) of tumour, VOL of lymph nodes, ΔVOL, sphericity, SUVpeak, ΔSUVpeak, and oligometastatic disease. Results: Median follow-up was 7.6 years. SCC had higher sub-distribution hazard ratio (sHR) for LRF (sHR = 2.771 [1.577:4.87], p < 0.01) and decreased sHR for DM (sHR = 0.247 [0.125:0.485], p  <  0.01). For both image models, high diagnostic SUVpeak increased risk of LRF (sHR = 1.059 [1.05:1.106], p < 0.01 for SCC, sHR = 1.12 [1.03:1.21], p < 0.01 for non-SCC). Patients with SCC and less decrease in VOL had higher sHR for DM (sHR = 1.025[1.001:1.048] pr. % increase, p = 0.038). Conclusion: Poor response in disease volume was correlated with higher sHR of DM for SCC, no other clear correlation of response and PoF was observed. Histology significantly correlated with PoF with SCC prone to LRF and non-SCC prone to DM as first site of failure. High SUVpeak at diagnosis increased the risk of LRF for both histologies.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38186677

RESUMEN

Introduction: Clinical trials lead the progress in healthcare. To ensure reliable research conclusions, it is essential to enroll diverse patient groups. Identifying and understanding patient-reported barriers to clinical trials may help enhance recruitment among diverse patient groups.The clinical potential of proton therapy (PT) to reduce late effects is being investigated in clinical trials worldwide. Thus, for some patients, PT is only accessible by participating in clinical trials.Individuals with smoking-related head and neck cancer (HNC) are sometimes socioeconomically deprived, leading to barriers to trial participation. This study aims to identify barriers to their participation in a randomised controlled trial (RCT) involving PT. Method: Interviews were conducted with 14 HNC patients declining participation in an RCT involving PT. The interviews were transcribed and systematically analysed using an inductive approach identifying categories and themes. Results: The identified barriers to RCT-participation are: (1) existential distress, which influenced participants' mental and cognitive capacities, (2) insufficient RCT-related knowledge arising from information overload during clinical consultations, (3) the wish for safety and familiarity during the treatment trajectory, particularly for participants needing accommodation during  radiotherapy, and (4) the motivation for study participation was impacted by uncertainty due to randomisation and clinical equipoise. Existential distress is identified as an overarching theme because it influences and amplifies the other three themes. Conclusion: Existential distress is a central theme that influences and amplifies other participation barriers in PT RCTs. It affects participants' comprehension of trial information, their preference for familiar environments, and their motivation to participate in clinical trials.

11.
Radiother Oncol ; 190: 109812, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37479061

RESUMEN

INTRODUCTION: Proton treatment can potentially spare patients with H&N cancer for substantial treatment-related toxicities. The current study investigated the reproducibility of a decentralised model-based selection of patients for a proton treatment study when the selection plans were compared to the clinical treatment plans performed at the proton centre. METHODS: Sixty-three patients were selected for proton treatment in the six Danish Head and Neck Cancer (DAHANCA) centres. The patients were selected based on normal tissue complication probability (NTCP) estimated from local photon and proton treatment plans, which showed a ΔNTCP greater than 5%-point for either grade 2 + dysphagia or grade 2 + xerostomia at six months. The selection plans were compared to the clinical treatment plans performed at the proton centre. RESULTS: Of the 63 patients, 49 and 25 were selected based on an estimated benefit in risk of dysphagia and xerostomia, respectively. Eleven patients had a potential gain in both toxicities. The mean ΔNTCP changed from the local selection plan comparison to the clinical comparison from 6.9 to 5.3 %-points (p = 0.01) and 7.3 to 4.9 %-points (p = 0.03) for dysphagia and xerostomia, respectively. Volume differences in both CTV and OAR could add to the loss in ΔNTCP. 61 of the 63 clinical plans had a positive ΔNTCP, and 38 had a ΔNTCP of 5%-points for at least one of the two endpoints. CONCLUSION: A local treatment plan comparison can be used to select candidates for proton treatment. The local comparative proton plan overestimates the potential benefit of the clinical proton plan. Continuous quality assurance of the delineation procedures and planning is crucial in the subsequent randomised clinical trial setting.


Asunto(s)
Trastornos de Deglución , Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Xerostomía , Humanos , Protones , Órganos en Riesgo , Trastornos de Deglución/etiología , Reproducibilidad de los Resultados , Dosificación Radioterapéutica , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/etiología , Xerostomía/etiología , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
12.
Acta Oncol ; 62(10): 1161-1168, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37850659

RESUMEN

BACKGROUND: Previously, many radiotherapy (RT) trials were based on a few selected dose measures. Many research questions, however, rely on access to the complete dose information. To support such access, a national RT plan database was created. The system focuses on data security, ease of use, and re-use of data. This article reports on the development and structure, and the functionality and experience of this national database. METHODS AND MATERIALS: A system based on the DICOM-RT standard, DcmCollab, was implemented with direct connections to all Danish RT centres. Data is segregated into any number of collaboration projects. User access to the system is provided through a web interface. The database has a finely defined access permission model to support legal requirements. RESULTS: Currently, data for more than 14,000 patients have been submitted to the system, and more than 50 research projects are registered. The system is used for data collection, trial quality assurance, and audit data set generation.Users reported that the process of submitting data, waiting for it to be processed, and then manually attaching it to a project was resource intensive. This was accommodated with the introduction of triggering features, eliminating much of the need for users to manage data manually. Many other features, including structure name mapping, RT plan viewer, and the Audit Tool were developed based on user input. CONCLUSION: The DcmCollab system has provided an efficient means to collect and access complete datasets for multi-centre RT research. This stands in contrast with previous methods of collecting RT data in multi-centre settings, where only singular data points were manually reported. To accommodate the evolving legal environment, DcmCollab has been defined as a 'data processor', meaning that it is a tool for other research projects to use rather than a research project in and of itself.


Asunto(s)
Oncología por Radiación , Radioterapia , Humanos , Ensayos Clínicos como Asunto
14.
Acta Oncol ; 62(11): 1418-1425, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37703300

RESUMEN

BACKGROUND: In the Danish Head and Neck Cancer Group (DAHANCA) 35 trial, patients are selected for proton treatment based on simulated reductions of Normal Tissue Complication Probability (NTCP) for proton compared to photon treatment at the referring departments. After inclusion in the trial, immobilization, scanning, contouring and planning are repeated at the national proton centre. The new contours could result in reduced expected NTCP gain of the proton plan, resulting in a loss of validity in the selection process. The present study evaluates if contour consistency can be improved by having access to AI (Artificial Intelligence) based contours. MATERIALS AND METHODS: The 63 patients in the DAHANCA 35 pilot trial had a CT from the local DAHANCA centre and one from the proton centre. A nationally validated convolutional neural network, based on nnU-Net, was used to contour OARs on both scans for each patient. Using deformable image registration, local AI and oncologist contours were transferred to the proton centre scans for comparison. Consistency was calculated with the Dice Similarity Coefficient (DSC) and Mean Surface Distance (MSD), comparing contours from AI to AI and oncologist to oncologist, respectively. Two NTCP models were applied to calculate NTCP for xerostomia and dysphagia. RESULTS: The AI contours showed significantly better consistency than the contours by oncologists. The median and interquartile range of DSC was 0.85 [0.78 - 0.90] and 0.68 [0.51 - 0.80] for AI and oncologist contours, respectively. The median and interquartile range of MSD was 0.9 mm [0.7 - 1.1] mm and 1.9 mm [1.5 - 2.6] mm for AI and oncologist contours, respectively. There was no significant difference in ΔNTCP. CONCLUSIONS: The study showed that OAR contours made by the AI algorithm were more consistent than those made by oncologists. No significant impact on the ΔNTCP calculations could be discerned.


Asunto(s)
Inteligencia Artificial , Neoplasias de Cabeza y Cuello , Humanos , Órganos en Riesgo , Protones , Planificación de la Radioterapia Asistida por Computador/métodos
15.
Acta Oncol ; 62(11): 1566-1573, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37603112

RESUMEN

BACKGROUND: The purpose of this study was to introduce an experimental radiobiological setup used for in vivo irradiation of a mouse leg target in multiple positions along a proton beam path to investigate normal tissue- and tumor models with varying linear energy transfer (LET). We describe the dosimetric characterizations and an acute- and late-effect assay for normal tissue damage. METHODS: The experimental setup consists of a water phantom that allows the right hind leg of three to five mice to be irradiated at the same time. Absolute dosimetry using a thimble (Semiflex) and a plane parallel (Advanced Markus) ionization chamber and Monte Carlo simulations using Geant4 and SHIELD-HIT12A were applied for dosimetric validation of positioning along the spread-out Bragg peak (SOBP) and at the distal edge and dose fall-off. The mice were irradiated in the center of the SOBP delivered by a pencil beam scanning system. The SOBP was 2.8 cm wide, centered at 6.9 cm depth, with planned physical single doses from 22 to 46 Gy. The biological endpoint was acute skin damage and radiation-induced late damage (RILD) assessed in the mouse leg. RESULTS: The dose-response curves illustrate the percentage of mice exhibiting acute skin damage, and at a later point, RILD as a function of physical doses (Gy). Each dose-response curve represents a specific severity score of each assay, demonstrating a higher ED50 (50% responders) as the score increases. Moreover, the results reveal the reversible nature of acute skin damage as a function of time and the irreversible nature of RILD as time progresses. CONCLUSIONS: We want to encourage researchers to report all experimental details of their radiobiological setups, including experimental protocols and model descriptions, to facilitate transparency and reproducibility. Based on this study, more experiments are being performed to explore all possibilities this radiobiological experimental setup permits.


Asunto(s)
Terapia de Protones , Protones , Animales , Ratones , Reproducibilidad de los Resultados , Terapia de Protones/métodos , Radiometría/métodos , Modelos Teóricos , Método de Montecarlo
16.
JCO Glob Oncol ; 8: e2100358, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35960905

RESUMEN

The discipline of radiation oncology is the most resource-intensive component of comprehensive cancer care because of significant initial investments required for machines, the requirement of dedicated construction, a multifaceted workforce, and recurring maintenance costs. This review focuses on the challenges associated with accessible and affordable radiation therapy (RT) across the globe and the possible solutions to improve the current scenario. Most common cancers globally, including breast, prostate, head and neck, and cervical cancers, have a RT utilization rate of > 50%. The estimated annual incidence of cancer is 19,292,789 for 2020, with > 70% occurring in low-income countries and low-middle-income countries. There are approximately 14,000 teletherapy machines globally. However, the distribution of these machines is distinctly nonuniform, with low-income countries and low-middle-income countries having access to < 10% of the global teletherapy machines. The Directory of Radiotherapy Centres enlists 3,318 brachytherapy facilities. Most countries with a high incidence of cervical cancer have a deficit in brachytherapy facilities, although formal estimates for the same are not available. The deficit in simulators, radiation oncologists, and medical physicists is even more challenging to quantify; however, the inequitable distribution is indisputable. Measures to ensure equitable access to RT include identifying problems specific to region/country, adopting indigenous technology, encouraging public-private partnership, relaxing custom duties on RT equipment, global/cross-country collaboration, and quality human resources training. Innovative research focusing on the most prevalent cancers aiming to make RT utilization more cost-effective while maintaining efficacy will further bridge the gap.


Asunto(s)
Braquiterapia , Neoplasias , Oncología por Radiación , Atención Integral de Salud , Humanos , Masculino , Neoplasias/epidemiología , Neoplasias/radioterapia , Recursos Humanos
17.
Radiother Oncol ; 175: 178-184, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35595175

RESUMEN

PURPOSE: Preclinical studies indicate a normal tissue sparing effect when ultra-high dose rate (FLASH) radiation is used, while tumor response is maintained. This differential response has promising perspectives for improved clinical outcome. This study investigates tumor control and normal tissue toxicity of pencil beam scanning (PBS) proton FLASH in a mouse model. METHODS AND MATERIALS: Tumor bearing hind limbs of non-anaesthetized CDF1 mice were irradiated in a single fraction with a PBS proton beam using either conventional (CONV) dose rate (0.33-0.63 Gy/s field dose rate, 244 MeV) or FLASH (71-89 Gy/s field dose rate, 250 MeV). 162 mice with a C3H mouse mammary carcinoma subcutaneously implanted in the foot were irradiated with physical doses of 40-60 Gy (8-14 mice per dose point). The endpoints were tumor control (TC) assessed as no recurrent tumor at 90 days after treatment, the level of acute moist desquamation (MD) to the skin of the foot within 25 days post irradiation, and radiation induced fibrosis (RIF) within 24 weeks post irradiation. RESULTS: TCD50 (dose for 50% tumor control) was similar for CONV and FLASH with values (and 95% confidence intervals) of 49.1 (47.0-51.4) Gy for CONV and 51.3 (48.6-54.2) Gy for FLASH. RIF analysis was restricted to mice with tumor control. Both endpoints showed distinct normal tissue sparing effect of proton FLASH with MDD50 (dose for 50% of mice displaying moist desquamation) of <40.1 Gy for CONV and 52.3 (50.0-54.6) Gy for FLASH, (dose modifying factor at least 1.3) and FD50 (dose for 50% of mice displaying fibrosis) of 48.6 (43.2-50.8) Gy for CONV and 55.6 (52.5-60.1) Gy for FLASH (dose modifying factor of 1.14). CONCLUSIONS: FLASH had the same tumor control as CONV, but reduced normal tissue damage assessed as acute skin damage and radiation induced fibrosis.


Asunto(s)
Terapia de Protones , Protones , Ratones , Animales , Ratones Endogámicos C3H , Recurrencia Local de Neoplasia , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Piel/efectos de la radiación , Dosificación Radioterapéutica
19.
Acta Oncol ; 61(2): 120-126, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34979878

RESUMEN

PURPOSE: The study aimed to investigate the pattern of failure and describe compromises in the definition and coverage of the target for patients treated with curatively intended radiotherapy (RT) for sinonasal cancer (SNC). METHODS AND MATERIAL: Patients treated with curatively intended RT in 2008-2015 in Denmark for SNC were eligible for the retrospective cohort study. Information regarding diagnosis and treatment was retrieved from the national database of the Danish Head and Neck Cancer Group (DAHANCA). Imaging from the diagnosis of recurrences was collected, and the point of origin (PO) of the recurrent tumour was estimated. All treatment plans were collected and reviewed with the focus on target coverage, manual modifications of target volumes, and dose to organs at risk (OARs) above defined constraints. RESULTS: A total of 184 patients were included in the analysis, and 76 (41%) relapsed. The majority of recurrences involved T-site (76%). Recurrence imaging of 39 patients was evaluated, and PO was established. Twenty-nine POs (74%) were located within the CTV, and the minimum dose to the PO was median 64.1 Gy (3.1-70.7). The criteria for target coverage (V95%) was not met in 89/184 (48%) of the CTV and 131/184 (71%) of the PTV. A total of 24% of CTVs had been manually modified to spare OARs of high-dose irradiation. No difference in target volume modifications was observed between patients who suffered recurrence and patients with lasting remission. CONCLUSION: The majority of relapses after radical treatment of SNC were located in the T-site (the primary tumour site). Multiple compromises with regards to target coverage and tolerance levels for OARs in the sinonasal region, as defined from RT guidelines, were taken. No common practice in this respect could be derived from the study.


Asunto(s)
Neoplasias de los Senos Paranasales , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Dinamarca/epidemiología , Humanos , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/radioterapia , Neoplasias de los Senos Paranasales/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
20.
Radiother Oncol ; 167: 109-115, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34953933

RESUMEN

BACKGROUND AND PURPOSE: Preclinical studies indicate a normal tissue sparing effect using ultra-high dose rate (FLASH) radiation with comparable tumor response. Most data so far are based on electron beams with limited utility for human treatments. This study validates the effect of proton FLASH delivered with pencil beam scanning (PBS) in a mouse leg model of acute skin damage and quantifies the normal tissue sparing factor, the FLASH factor, through full dose response curves. MATERIALS AND METHODS: The right hind limb of CDF1 mice was irradiated with a single fraction of proton PBS in the entrance plateau of either a 244 MeV conventional dose rate field or a 250 MeV FLASH field. In total, 301 mice were irradiated in four separate experiments, with 7-21 mice per dose point. The endpoints were the level of acute moist desquamation to the skin of the foot within 25 days post irradiation. RESULTS: The field duration and field dose rate were 61-107 s and 0.35-0.40 Gy/s for conventional dose rate and 0.35-0.73 s and 65-92 Gy/s for FLASH. Full dose response curves for five levels of acute skin damage for both conventional and FLASH dose rate revealed a distinct normal tissue sparing effect with FLASH: across all scoring levels, a 44-58% higher dose was required to give the same biological response with FLASH as compared to the conventional dose rate. CONCLUSIONS: The normal tissue sparing effect of PBS proton FLASH was validated. The FLASH factor was quantified through full dose response curves.


Asunto(s)
Terapia de Protones , Protones , Animales , Humanos , Ratones , Dosificación Radioterapéutica , Tromboplastina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...