Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
3.
Heart Rhythm ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969051

RESUMEN

BACKGROUND: Data on Transvenous (TV) lead-associated superior vena cava (SVC) syndrome are limited. The management of this problem might require a multidisciplinary approach, often involving TV lead extraction (TLE) followed by angioplasty and stenting. OBJECTIVE: To describe the management and outcome of TV lead-associated SVC syndrome METHODS: We retrospectively identified patients with a diagnosis of SVC syndrome and TV leads at Emory Healthcare between 2015 and 2023. RESULTS: 15 patients with lead-related SVC syndrome were identified. The cohort average age was 50 years. Symptoms included swelling in the face, neck, and upper extremity (67%), shortness of breath (53%) and lightheadedness (40%). Patients had on average 2 ± 0.7 leads crossing the SVC with a lead dwell time of 9.8 ± 7.5 years. Thirteen patients were managed with transvenous lead extraction (TLE), followed by SVC stenting and angioplasty (10), angioplasty alone (2), while one patient had no intervention after TLE. One patient was managed with anticoagulation, and another had angioplasty and stenting with lead jailing. One patient experienced SVC perforation and cardiac tamponade during SVC stenting managed successfully with a covered stent and pericardiocentesis. Among the 12 patients with TLE and angioplasty ± stenting, 7 patients underwent reimplantation of a transvenous lead. Two of those patients had symptoms recurrence and none of the 5 patients without lead reimplantation had recurrence of symptoms. CONCLUSION: Lead-related SVC syndrome management requires a multidisciplinary approach often including TLE followed by angioplasty and stenting. Avoiding TV lead reimplantation might help reduce symptoms recurrence.

4.
Blood Cancer Discov ; 5(4): 258-266, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747505

RESUMEN

Chimeric antigen receptor (CAR) T-cell therapy produces high response rates in refractory B-cell non-Hodgkin lymphoma, but long-term data are minimal to date. In this study, we present long-term follow-up of a pilot trial testing a CD20-targeting third-generation CAR in patients with relapsed B-cell lymphomas following cyclophosphamide-only lymphodepletion. Two of the three patients in the trial, with mantle cell lymphoma and follicular lymphoma, had remissions lasting more than 7 years, though they ultimately relapsed. The absence of B-cell aplasia in both patients suggested a lack of functional CAR T-cell persistence, leading to the hypothesis that endogenous immune responses were responsible for these long-term remissions. Correlative immunologic analyses supported this hypothesis, with evidence of new humoral and cellular antitumor immune responses proximal to clinical response time points. Collectively, our results suggest that CAR T-cell therapy may facilitate epitope spreading and endogenous immune response formation in lymphomas. Significance: Two of three patients treated with CD20-targeted CAR T-cell therapy had long-term remissions, with evidence of endogenous antitumor immune response formation. Further investigation is warranted to develop conditions that promote epitope spreading in lymphomas.


Asunto(s)
Antígenos CD20 , Inmunoterapia Adoptiva , Receptores Quiméricos de Antígenos , Inducción de Remisión , Humanos , Antígenos CD20/inmunología , Receptores Quiméricos de Antígenos/inmunología , Inmunoterapia Adoptiva/métodos , Persona de Mediana Edad , Masculino , Femenino , Anciano , Linfoma Folicular/terapia , Linfoma Folicular/inmunología , Proyectos Piloto , Linfocitos T/inmunología , Linfocitos T/trasplante , Resultado del Tratamiento
5.
JACC Clin Electrophysiol ; 10(5): 814-825, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38811066

RESUMEN

BACKGROUND: Deep intramural ventricular tachycardia substrate targets are difficult to access, map, and ablate from endocardial and epicardial surfaces, resulting in high recurrence rates. OBJECTIVES: In this study, the authors introduce a novel approach called ventricular intramyocardial navigation for tachycardia ablation guided by electrograms (VINTAGE) to access and ablate anatomically challenging ventricular tachycardia from within the myocardium. METHODS: Guidewire/microcatheter combinations were navigated deep throughout the extravascular myocardium, accessed directly from the right ventricle cavity, in Yorkshire swine (6 naive, 1 infarcted). Devices were steered to various intramyocardial targets including the left ventricle summit, guided by fluoroscopy, unipolar electrograms, and/or electroanatomic mapping. Radiofrequency ablations were performed to characterize ablation parameters and reproducibility. Intramyocardial saline irrigation began 1 minute before ablation and continued throughout. Lesions were analyzed on cardiac magnetic resonance and necropsy. RESULTS: VINTAGE was feasible in all animals within naive and infarcted myocardium. Forty-three lesions were created, using various guidewires and power settings. Forty-one (95%) lesions were detected on cardiac magnetic resonance and 38 (88%) on necropsy; all undetected lesions resulted from intentionally subtherapeutic ablation energy (10 W). Larger-diameter guidewires yielded larger size lesions. Lesion volumes on necropsy were significantly larger at 20 W than 10 W (178 mm3 [Q1-Q3: 104-382 mm3] vs 49 mm3 [Q1-Q3: 35-93 mm3]; P = 0.02). Higher power (30 W) did not create larger lesions. Median impedance dropped with preablation irrigation by 12 Ω (Q1-Q3: 8-17 Ω), followed by a further 15-Ω (Q1-Q3: 11-19 Ω) drop during ablation. Intramyocardial navigation, ablation, and irrigation were not associated with any complications. CONCLUSIONS: VINTAGE was safe and effective at creating intramural ablation lesions in targets traditionally considered inaccessible from the endocardium and epicardium, both naive and infarcted. Intramyocardial guidewire irrigation and ablation at 20 W creates reproducibly large intramural lesions.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular , Animales , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Porcinos , Técnicas Electrofisiológicas Cardíacas/métodos , Ventrículos Cardíacos/cirugía , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen
6.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
7.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38604492

RESUMEN

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Asunto(s)
Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Insuficiencia de la Válvula Tricúspide/cirugía , Femenino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Causas de Muerte/tendencias , Complicaciones Posoperatorias/epidemiología , Anciano de 80 o más Años , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen
8.
Interv Cardiol Clin ; 13(2): 217-225, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432764

RESUMEN

Left ventricular outflow tract (LVOT) obstruction is a life-threatening complication of transcatheter mitral valve replacement. In-depth analysis of pre-procedural computed tomography enables accurate prediction of this risk. Several techniques for LVOT modification, including Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN, preemptive alcohol septal ablation, preemptive radiofrequency ablation, and Septal Scoring Along the Midline Endocardium, have been described as effective strategies to mitigate this risk. This review aims to explore the indications, procedural steps, and outcomes associated with these LVOT modification techniques.


Asunto(s)
Endocardio , Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Tomografía Computarizada por Rayos X
9.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38471643

RESUMEN

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Asunto(s)
Cardiomiopatía Hipertrófica , Implantación de Prótesis de Válvulas Cardíacas , Miotomía , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cardiomiopatía Hipertrófica/complicaciones , Miotomía/efectos adversos
10.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38533653

RESUMEN

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Valvuloplastia con Balón , Modelos Animales de Enfermedad , Hemodinámica , Animales , Hemodinámica/efectos de los fármacos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Sus scrofa , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Diseño de Equipo , Recuperación de la Función , Enfermedad Aguda , Catéteres Cardíacos , Factores de Tiempo , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda/efectos de los fármacos
11.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38244000

RESUMEN

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Stents , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
13.
JACC Case Rep ; 27: 102074, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38094720

RESUMEN

Critical bioprosthetic aortic valve stenosis is a rare finding in the second trimester of pregnancy. We present the case of a successful valve-in-valve transcatheter aortic valve replacement in a 16-weeks-pregnant patient. We describe the significant role of the multidisciplinary heart team during preconception and pregnancy.

15.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
16.
Circ Cardiovasc Interv ; 16(10): e013243, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37732604

RESUMEN

BACKGROUND: Postinfarction ventricular septal defect (VSD) is a catastrophic complication of myocardial infarction. Surgical repair still has poor outcomes. This report describes clinical outcomes after a novel hybrid transcatheter/surgical repair in patients with apical VSD. METHODS: Seven patients with postmyocardial infarction apical VSD underwent hybrid transcatheter repair via subxiphoid surgical access. A transcatheter occluder (Amplatzer Septal Occluder) with a trailing premounted suture was deployed through the right ventricular wall and through the ventricular septum into the left ventricular apex. The trailing suture was used to connect an anchor external to the right ventricular wall. Tension on the suture then collapses the right ventricular free wall against the septum and left ventricular occluder, thereby obliterating the VSD. Outcomes were compared with 9 patients who underwent surgical repair using either patch or primary suture closure. RESULTS: All patients had significant left-to-right shunt (Qp:Qs 2.5:1; interquartile range [IQR, 2.1-2.6] hybrid repair versus 2.0:1 [IQR, 2.0-2.5] surgical repair), and elevated right ventricular systolic pressure (62 [IQR, 46-71] versus 49 [IQR, 43-54] mm Hg, respectively). All had severely depressed stroke volume index (22 versus 21 mL/m2) with ≈45% in each group requiring mechanical support preprocedurally. The procedure was done 15 (IQR, 10-50) versus 24 (IQR, 10-134) days postmyocardial infarction, respectively. Both groups of patients underwent repair with technical success and without intraprocedural death. One patient in the hybrid group and 4 in the surgical group developed multiorgan failure. The hybrid group had a higher survival at discharge (86% versus 56%) and at 30 days (71% versus 56%), but similar at 1 year (57% versus 56%). During follow-up, 1 patient in each group required reintervention for residual VSD (hybrid: 9 months versus surgical: 5 days). CONCLUSIONS: Early intervention with a hybrid transcatheter/surgical repair may be a viable alternative to traditional surgery for postinfarction apical VSD.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Defectos del Tabique Interventricular , Infarto del Miocardio , Dispositivo Oclusor Septal , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/terapia
17.
Circ Cardiovasc Interv ; 16(9): e013123, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37577788

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) in patients with a congenital or acquired abnormality resulting in enlarged right ventricular outflow tract (RVOT) is challenging and may preclude treatment with dedicated devices. We describe a technique using a physician-modified endograft to facilitate TPVR. METHODS: Six patients underwent physician-modified endograft-facilitated TPVR for severe symptomatic pulmonary insufficiency with enlarged RVOT. The fenestration was created in a commercially available endograft before implantation, which was then deployed from the dominant branch pulmonary artery into the RVOT, with the fenestration aligned with the ostium of the nondominant pulmonary artery. A covered stent was placed through the fenestration into the nondominant branch pulmonary artery, and a transcatheter heart valve was deployed within the endograft at the level of the original pulmonary valve. RESULTS: Four patients had tetralogy of Fallot, 1 had pulmonary atresia, and 1 had rheumatic valve disease. The RVOT/main pulmonary artery was severely enlarged (diameter, 44.2 [43.5-50.6] mm). All patients had reduced right ventricular (RV) function and dilated RVs (RV end-diastolic volume, 314 [235-316] mL). Successful endograft, covered stent, and transcatheter heart valve deployment were achieved in all cases without stent/valve embolization, vascular complications, or bleeding complications. At 30 days, 1 patient had mild pulmonary insufficiency, while others had none. The RV size measured by echocardiography was significantly reduced after TPVR (RV area, 34.4 [baseline] versus 29.0 [pre-discharge] versus 25.3 [30 days] cm2; P=0.03). During median follow-up of 221.5 (range, 29-652) days, there were no deaths or need for pulmonary valve reintervention. One patient developed severe tricuspid regurgitation due to entrapment of the anterior tricuspid leaflet by the endograft. The patient underwent successful tricuspid replacement and resection of the offending endograft with preservation of the pulmonary valve prosthesis. CONCLUSIONS: Simple fenestration of an off-the-shelf endograft and associated covered stent placement through the fenestration allows TPVR for patients with dysfunctional native or patch-repaired pulmonary valves and RVOT enlargement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis
18.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1741-1754, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37354176

RESUMEN

BACKGROUND: Intramyocardial guidewire navigation is a novel technique that allows free transcatheter movement within ventricular muscle. Guidewire radial depth, between endocardial and epicardial surfaces, is ambiguous by x-ray and echocardiography. OBJECTIVES: The aim of this study was to develop a simple tool, EDEN (Electrocardiographic Radial Depth Navigation), to indicate radial depth during intramyocardial guidewire navigation. Combined with routine imaging, EDEN facilitates a new family of intramyocardial catheter procedures to slice, reshape, pace, and ablate the heart. METHODS: We mapped intramyocardial electrograms of left and right ventricular walls and septum during open- and closed-chest swine procedures (N = 53), including MIRTH (Myocardial Intramural Remodeling by Transvenous Tether) ventriculoplasty. We identified radial depth-dependent features on unipolar electrograms. We developed a machine learning-based classifier to indicate categorical position, and modeled the findings in silico to test understanding of the physiology. RESULTS: EDEN signatures distinguished 5 depth zones throughout left and right ventricular free walls and interventricular septum. Relative ST-segment elevation magnitude best discriminated position and was maximum (40.1 ± 6.5 mV) in the midmyocardium. Subendocardial positions exhibited dominant Q waves with lower-amplitude ST segments (16.8 ± 5.8 mV), whereas subepicardial positions exhibited dominant R waves with lower-amplitude ST segments (15.7 ± 4.8 mV). EDEN was unaffected by pacing-induced left bundle branch block. ST-segment elevation declined over minutes and reappeared after submillimeter guidewire manipulation. Modeling recapitulated EDEN features. The machine learning-based classifier was 97% accurate. EDEN successfully guided MIRTH ventriculoplasty. CONCLUSIONS: EDEN provides a simple and reproducible real-time reflection of categorical guidewire-tip radial depth during intramyocardial guidewire navigation. Used in tandem with x-ray, EDEN enables novel, transcatheter, intramyocardial therapies such as MIRTH, SESAME (Septal Surfing Along Midline Endocardium), and cerclage ventriculoplasty.


Asunto(s)
Electrocardiografía , Miocardio , Animales , Porcinos , Electrocardiografía/métodos , Corazón , Endocardio , Ventrículos Cardíacos/diagnóstico por imagen
20.
J Am Coll Cardiol ; 81(18): 1766-1776, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37137586

RESUMEN

BACKGROUND: Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution. OBJECTIVES: The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR. METHODS: Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates. RESULTS: Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001). CONCLUSIONS: The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...