Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Acta Clin Croat ; 61(Suppl 3): 21-27, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36938551

RESUMEN

Intensity modulated radiotherapy (IMRT) has become widely used as a standard radiation therapy technique for the treatment of localized prostate cancer. The transition from conformal radiotherapy (3D CRT) to a more complex IMRT technique triggered the need for more thorough verification of the accuracy in the dose delivery. In this work we present the clinical workflow and the results of patient specific quality assurance (PSQA) procedures for 40 prostate cancer patients who have been treated with step and shot IMRT ever since its implementation in our routine clinical practice. PSQA procedures include dosimetric verification of each treatment plan with dedicated rotational phantom and high-resolution matrix detector system Octavius 4D (PTW Freiburg) that allows three-dimensional comparison of the calculated and delivered radiation dose distribution. Our results proved the compliance with the universal tolerance limits recommended for those procedures (1), assuring the safety of the treatment and providing the possibility for the adoption of more stringent constraints in the future.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Neoplasias de la Próstata/radioterapia
2.
Acta Clin Croat ; 61(Suppl 3): 65-70, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36938552

RESUMEN

Radiotherapy is one of the key treatment modalities for primary prostate cancer. During the last decade, significant advances were made in radiotherapy technology leading to increasing both physical and biological precision. Being a loco-regional treatment approach, radiotherapy requires accurate target dose deposition while sparing surrounding healthy tissue. Conventional radiotherapy is based on computerized tomography (CT) images both for radiotherapy planning and image-guidance, however, shortcomings of CT as soft tissue imaging tool are well known. Nowadays, our ability to further escalate radiotherapy dose using hypofractionation is limited by uncertainties in CT-based image guidance and verification. Magnetic resonance imaging (MRI) is a well established imaging method for pelvic organs. In prostate cancer specifically, MRI accurately depicts prostate zonal anatomy, rectum, bladder, and pelvic floor structures with previously unseen precision owing to its sharp soft tissue contrast. The advantages of including MRI in the clinical workflow of prostate cancer radiotherapy are multifold. MRI allows for true adaptive radiotherapy to unfold based on daily MRI images taken before, during and after each radiotherapy fraction. It enables accurate dose escalation to the prostate and intraprostatic tumor lesions. Technically, MRI high-strength magnetic field and linear accelerator high energy electromagnetic beams are hardly compatible, and important efforts were made to overcome these technical challenges and integrate MRI and linear accelerator into one single treatment device, called MRI-linac. Different systems are produced by two leading vendors in the field and currently, there are around 100 MRI-linacs worldwide in clinical operations. In this narrative review paper, we discuss historical perspective of image guidance in radiotherapy, basic elements of MRI, current clinical developments in MRI-guided prostate cancer radiotherapy, and challenges associated with the use of MRI-linac in clinical practice.


Asunto(s)
Neoplasias de la Próstata , Radioterapia Guiada por Imagen , Masculino , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos
3.
Radiol Oncol ; 53(4): 488-496, 2019 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-31747379

RESUMEN

Background The aim of this study was to determine the possible predictive value of various dosimetric parameters on the development of hypothyroidism (HT) in patients with head and neck squamous cell carcinoma (HNSCC) treated with (chemo)radiotherapy. Patients and methods This study included 156 patients with HNSCC who were treated with (chemo)radiotherapy in a primary or postoperative setting between August 2012 and September 2017. Dose-volume parameters as well as V10 toV70, D02 to D98, and the VS10 to VS70 were evaluated. The patients' hormone status was regularly assessed during follow-up. A nomogram (score) was constructed, and the Kaplan-Maier curves and Log-Rank test were used to demonstrate the difference in incidence of HT between cut-off values of specific variables. Results After a median follow-up of 23.0 (12.0-38.5) months, 70 (44.9%) patients developed HT. In univariate analysis, VS65, Dmin, V50, and total thyroid volume (TTV) had the highest accuracy in predicting HT. In a multivariate model, HT was associated with lower TTV (OR 0.31, 95% CI 0.11-0.87, P = 0.026) and Dmin (OR 9.83, 95% CI 1.89-108.08, P = 0.042). Hypothyroidism risk score (HRS) was constructed as a regression equation and comprised TTV and Dmin. HRS had an AUC of 0.709 (95% CI 0.627-0.791). HT occurred in 13 (20.0%) patients with a score < 7.1 and in 57 (62.6%) patients with a score > 7.1. Conclusions The dose volume parameters VS65, Dmin, V50, and TTV had the highest accuracy in predicting HT. The HRS may be a useful tool in detecting patients with high risk for radiation-induced hypothyroidism.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Hipotiroidismo/inducido químicamente , Traumatismos por Radiación/patología , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Nomogramas , Dosificación Radioterapéutica , Estudios Retrospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello/patología , Pruebas de Función de la Tiroides
4.
Acta Clin Croat ; 58(Suppl 2): 82-83, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34975204
5.
Nucl Med Commun ; 39(8): 797-802, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29889160

RESUMEN

To make quantitative methods of nuclear medicine more available, four centres in Croatia participated in the national intercomparison study, following the materials and methods used in the previous international study organized by the International Atomic Energy Agency (IAEA). The study task was to calculate the activities of four Ba sources (T 1/2=10.54 years; E γ=356 keV) using planar and single-photon emission computed tomography (SPECT) or SPECT/CT acquisitions of the sources inside a water-filled cylindrical phantom. The sources were previously calibrated by the US National Institute of Standards and Technology. Triple-energy window was utilized for scatter correction. Planar studies were corrected for attenuation correction (AC) using the conjugate-view method. For SPECT/CT studies, data from X-ray computed tomography were used for attenuation correction (CT-AC), whereas for SPECT-only acquisition, the Chang-AC method was applied. Using the lessons learned from the IAEA study, data were acquired according to the harmonized data acquisition protocol, and the acquired images were then processed using centralized data analysis. The accuracy of the activity quantification was evaluated as the ratio R between the calculated activity and the value obtained from National Institute of Standards and Technology. For planar studies, R=1.06±0.08; for SPECT/CT study using CT-AC, R=1.00±0.08; and for Chang-AC, R=0.89±0.12. The results are in accordance with those obtained within the larger IAEA study and confirm that SPECT/CT method is the most appropriate for accurate activity quantification.


Asunto(s)
Agencias Internacionales , Energía Nuclear , Fantasmas de Imagen/normas , Croacia , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...