Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Cardiol Heart Vasc ; 53: 101435, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38946712

RESUMEN

Background: It is currently unknown whether high-resolution 3D-mapping and micro-electrodes add meaningful benefits in catheter ablation of Wolff-Parkinson-White (WPW) syndrome and challenging, e.g. para-Hisian accessory pathways (APs). Objectives: To compare the mapping resolution, acute success and complication rates in patients with WPW syndrome undergoing a first-time catheter ablation using only a contact force-sensing ablation catheter for mapping or a multi-electrode high-resolution mapping catheter. Methods: Fifty consecutive 3D-mapping procedures for WPW syndrome using a 3.5-mm ablation catheter (n = 27) or a multi-electrode high-resolution catheter (n = 23) were retrospectively analyzed regarding mapping resolution defined as first 5/10 msec isochronal activation area, number of RF applications to achieve AP block, occurence of AP automaticity during RF delivery, and acute success and complication rates. Results: Catheter ablation was successful in 48/50 patients with a median of 1 (IQR 1-2) RF applications. Compared to ablation catheter mapping, high-resolution mapping showed a significantly smaller isochronal activation area in the first 5/10 msec (1.25 ± 0.29 vs 0.15 ± 0.03 cm2; P < 0.001 and 3.41 ± 0.58 vs 0.55 ± 0.12 cm2; P < 0.0001) and significantly higher incidence of AP automaticity during RF delivery (0 vs 22 %; P < 0.05). In para-Hisian APs, micro-electrodes recorded distinct His electrograms and AP potentials without fusion and without AP bumping permitting safe and effective para-Hisian AP ablation. Conclusions: High-resolution mapping increases the mapping accuracy of the AP and its insertion site leading to a significantly higher incidence of AP automaticity during RF delivery. Micro-electrodes provide clinically relevant advantages in para-hisian AP mapping improving efficacy and safety of para-Hisian AP ablation.

3.
J Cardiovasc Electrophysiol ; 34(2): 420-428, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36444777

RESUMEN

INTRODUCTION: Defibrillation testing (DFT) is recommended during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. Previous studies analyzing the potential interference of propofol with defibrillation threshold are inconsistent. The purpose of this study was to analyze whether propofol affects DFT post S-ICD placement. METHODS: All patients with S-ICD implantation between 01/2017 and 11/2020 at the University Heart Center Freiburg were retrospectively analyzed. Two groups were generated depending on the success of the first shock during DFT. Implantation characteristics and dose of anesthetics were analyzed. RESULTS: In 12 of the included 80 (15%) patients, first shock during DFT failed. The absolute dose of propofol was significantly higher in patients with first shock failure (median 653 mg [IQR 503-855]) compared to patients with first shock termination (376 mg [200-600]; p = 0.027). Doses of opioids and midazolam as well as type of anesthesia did not differ between the groups. A multivariable binary logistic regression analysis confirmed an independent association of first shock termination and propofol dose (per 100 mg: OR 0.73 (95% CI: 0.56-0.95); p = 0.021). CONCLUSION: There is an independent association of propofol dose and first shock failure in routine S-ICD defibrillation testing.


Asunto(s)
Desfibriladores Implantables , Propofol , Humanos , Desfibriladores Implantables/efectos adversos , Propofol/efectos adversos , Estudios de Cohortes , Estudios Retrospectivos , Implantación de Prótesis/efectos adversos , Cardioversión Eléctrica/efectos adversos
4.
JACC Clin Electrophysiol ; 8(9): 1067-1076, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35780035

RESUMEN

BACKGROUND: The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping. OBJECTIVES: This study sought to report the initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray. METHODS: Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation. In addition, another 10 patients with sustained atrial tachycardia mapped with the 5-spline catheter (2-5-2 spacing) or the novel 8-spline catheter (2-2-2-2-2 spacing) were analyzed. RESULTS: Left atrial and ventricular mapping by either transseptal (n = 41) or retroaortic (n = 2) access was feasible without any complications related to the multispline design of the novel catheter. The acute procedural success rate was 94%. In sustained atrial tachycardia compared with the 5-spline catheter, the novel 8-spline catheter recorded more electrograms per map (3,628 ± 714 vs 11,350 ± 1,203; P < 0.001) in a shorter mapping time (13 ± 2 vs 9 ± 1 minutes; P = 0.08) resulting in a higher point density (18 ± 4 vs 59 ± 10 electrograms/cm2; P < 0.01) and point acquisition rate (308 ± 69 vs 1,332 ± 208 electrograms/min.; P < 0.01). CONCLUSIONS: In this initial experience, mapping with the novel catheter was safe and efficient with a high electroanatomical resolution. In sustained atrial tachycardia the novel 8-spline catheter demonstrated a marked increase in point density and mapping speed compared with those of the 5-spline catheter. These initial results should be validated in a larger multicenter cohort with longer follow-up.


Asunto(s)
Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Humanos , Venas Pulmonares/cirugía , Estudios Retrospectivos , Taquicardia Supraventricular/cirugía
5.
Clin Res Cardiol ; 111(5): 502-510, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-33770204

RESUMEN

BACKGROUND: The short-coupled variant of torsade de pointes (sc-TdP) is a malignant arrhythmia that frequently presents with ventricular fibrillation (VF) electrical storm. Verapamil is considered the first-line therapy of sc-TdP while catheter ablation is not widely adopted. The aim of this study was to determine the origin of sc-TdP and to assess the outcome of catheter ablation using 3D-mapping. METHODS AND RESULTS: We retrospectively analyzed five patients with sc-TdP who underwent 3D-mapping and ablation of sc-TdP at five different institutions. Four patients initially presented with sudden cardiac arrest, one patient experienced recurrent syncope as the first manifestation. All patients demonstrated a monomorphic premature ventricular contraction (PVC) with late transition left bundle branch block pattern, superior axis, and a coupling interval of less than 300 ms. triggering recurrent TdP and VF. In four patients, the culprit PVC was mapped to the free wall insertion of the moderator band (MB) with a preceding Purkinje potential in two patients. Catheter ablation using 3D-mapping and intracardiac echocardiography eliminated sc-TdP in all patients, with no recurrence at mean 2.7 years (range 6 months to 8 years) of follow-up. CONCLUSION: 3D-mapping and intracardiac echocardiography demonstrate that sc-TdP predominantly originates from the MB free wall insertion and its Purkinje network. Catheter ablation of the culprit PVC at the MB free wall junction leads to excellent short- and long-term results and should be considered as first-line therapy in recurrent sc-TdP or electrical storm.


Asunto(s)
Ablación por Catéter , Torsades de Pointes , Complejos Prematuros Ventriculares , Humanos , Ablación por Catéter/métodos , Proteínas de Unión al ADN , Electrocardiografía , Estudios Retrospectivos , Torsades de Pointes/diagnóstico , Torsades de Pointes/etiología , Fibrilación Ventricular , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
6.
J Cardiovasc Electrophysiol ; 32(11): 3095-3098, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34379359

RESUMEN

Combined implantation of cardiac contractility modulation (CCM) with subcutaneous implantable cardioverter-defibrillator (S-ICD) appears a suitable option to reduce the amount of intracardiac leads and complications for patients. Here we report on a patient with ischemic cardiomyopathy carrying an S-ICD in which a CCM device was implanted. During crosstalk testing post-CCM implantation, the S-ICD misannotated QRS complexes and T waves. The problem was solved through reprogramming the CCM, while preserving S-ICD functionality and improving heart failure symptoms. In conclusion, S-ICD combined with CCM seems to be a good and safe option for patients when device interference is being ruled out.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía , Arritmias Cardíacas , Desfibriladores , Humanos , Contracción Miocárdica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...