Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 11(3)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38534481

RESUMEN

CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

2.
J Pain ; 25(2): 497-507, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37742905

RESUMEN

Development of back pain is multifactorial, and it is not well understood which factors are the main drivers of the disease. We therefore applied a machine-learning approach to an existing large cohort study data set and sought to identify and rank the most important contributors to the presence of back pain amongst the documented parameters of the cohort. Data from 399 participants in the KORA-MRI (Cooperative health research in the region Augsburg-magnetic resonance imaging) (Cooperative Health Research in the Region Augsburg) study was analyzed. The data set included MRI images of the whole body, including the spine, metabolic, sociodemographic, anthropometric, and cardiovascular data. The presence of back pain was one of the documented items in this data set. Applying a machine-learning approach to this preexisting data set, we sought to identify the variables that were most strongly associated with back pain. Mediation analysis was performed to evaluate the underlying mechanisms of the identified associations. We found that depression and anxiety were the 2 most selected predictors for back pain in our model. Additionally, body mass index, spinal canal width and disc generation, medium and heavy physical work as well as cardiovascular factors were among the top 10 most selected predictors. Using mediation analysis, we found that the effects of anxiety and depression on the presence of back pain were mainly direct effects that were not mediated by spinal imaging. In summary, we found that psychological factors were the most important predictors of back pain in our cohort. This supports the notion that back pain should be treated in a personalized multidimensional framework. PERSPECTIVE: This article presents a wholistic approach to the problem of back pain. We found that depression and anxiety were the top predictors of back pain in our cohort. This strengthens the case for a multidimensional treatment approach to back pain, possibly with a special emphasis on psychological factors.


Asunto(s)
Dolor de la Región Lumbar , Humanos , Estudios de Cohortes , Dolor de la Región Lumbar/psicología , Depresión/diagnóstico por imagen , Dolor de Espalda/diagnóstico por imagen , Dolor de Espalda/epidemiología , Imagen por Resonancia Magnética , Ansiedad/diagnóstico por imagen , Ansiedad/epidemiología , Vértebras Lumbares/patología
3.
Diagnostics (Basel) ; 12(9)2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36140556

RESUMEN

Purpose: To assess the influence of different dual-energy CT (DECT) scanner techniques on the severity of visceral-motion-related artifacts on the liver. Methods: Two independent readers retrospectively evaluated visceral-motion-related artifacts on the liver on 120-kVp(-like), monoenergetic low- and high-keV, virtual non-contrast (VNC), and iodine images acquired on a dual-source, twin-beam, fast kV-switching, and dual-layer spectral detector scanner. Quantitative assessment: Depth of artifact extension into the liver, measurements of Hounsfield Units (HU) and iodine concentrations. Qualitative assessment: Five-point Likert scale (1 = none to 5 = severe). Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 615 contrast-enhanced routine clinical DECT scans of the abdomen were evaluated in 458 consecutive patients (mean age: 61 ± 14 years, 331 men). For dual-source and twin-beam scanners, depth of extension of artifacts into the liver was significantly shorter and artifact severity scores significantly lower for 120-kVp-like images compared with the other image reconstructions (p < 0.001, each). For fast kV-switching and spectral detector scanner images, depth of extension of artifacts was significantly shorter and artifact severity scores significantly lower for iodine images (p < 0.001, each). Dual-source 120-kVp-like and spectral detector iodine images reduced artifacts to an extent that no significant difference in HU or iodine concentrations between artifacts (dual-source: 97 HU, spectral detector: 1.9 mg/mL) and unaffected liver parenchyma (dual-source: 108 HU, spectral detector: 2.1 mg/mL) was measurable (dual-source: p = 0.32, spectral detector: p = 0.15). Conclusion: Visceral-motion-related artifacts on the liver can be markedly reduced by viewing 120-kVp-like images for dual-source and twin-beam DECT scanners and iodine images for fast kV-switching and dual-layer spectral detector DECT scanners.

4.
Radiol Clin North Am ; 60(5): 731-743, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35989041

RESUMEN

Dual-energy computed tomography (DECT) increases confidence in hepatobiliary computed tomography (CT) evaluation by boosting visible iodine enhancement and differentiating between materials based on relative attenuation of 2 different X-ray energy spectra. Image reconstructions from DECT scans improve the detection and characterization of focal liver lesions, allows for quantification of diffuse liver disease, and reveals gallstones that may be missed on standard CT imaging. Our article aims to illustrate the basic concepts of DECT and types of image reconstruction relevant for the assessment of hepatobiliary diseases. We then review literature on the use of DECT for evaluating focal and diffuse hepatobiliary diseases.


Asunto(s)
Yodo , Hepatopatías , Imagen Radiográfica por Emisión de Doble Fotón , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Hepatopatías/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos
5.
Eur Radiol ; 32(11): 7936-7945, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35486170

RESUMEN

OBJECTIVES: To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner. METHODS: We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age: 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better). RESULTS: Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing. CONCLUSIONS: Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing. KEY POINTS: • Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. • Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.


Asunto(s)
Colonografía Tomográfica Computarizada , Yodo , Humanos , Persona de Mediana Edad , Anciano , Colonografía Tomográfica Computarizada/métodos , Estudios Retrospectivos , Algoritmos , Catárticos , Artefactos
6.
Diagnostics (Basel) ; 12(4)2022 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-35453830

RESUMEN

Background: Peristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy. Purpose: To assess dual-layer spectral-detector computed tomography (CT) image reconstructions for reducing intestinal peristalsis-related streak artifacts on the liver. Methods: We retrospectively evaluated 220 contrast-enhanced abdominal dual-energy CT scans in 131 consecutive patients (mean age: 68 ± 10 years, 120 men) who underwent routine clinical dual-layer spectral-detector CT imaging (120 kVp, 40 keV, 200 keV, virtual non-contrast (VNC), iodine images). Two independent readers evaluated bowel peristalsis streak artifacts on the liver qualitatively on a five-point Likert scale (1 = none to 5 = severe) and quantitatively by depth of streak artifact extension into the liver and measurements of Hounsfield Unit and iodine concentration differences from normal liver. Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 12 scans were excluded due to missing spectral data, artifacts on the liver originating from metallic foreign materials, or oral contrast material. Streak artifacts on the liver were seen in 51/208 (25%) scans and involved the left lobe only in 49/51 (96%), the right lobe only in 0/51 (0%), and both lobes in 2/51 (4%) scans. Artifact frequency was lower in iodine than in 120 kVp images (scans 18/208 vs. 51/208, p < 0.001). Artifact severity was less in iodine than in 120 kVp images (median score 1 vs. 3, p < 0.001). Streak artifact extension into the liver was shorter in iodine than 120 kVp images (mean length 2 ± 4 vs. 12 ± 5 mm, p < 0.001). Hounsfield Unit and iodine concentration differed significantly between bright streak artifacts and normal liver in 120 kVp, 40 keV, 200 keV, and VNC images (p < 0.001, each), but not in iodine images (p = 0.23). Conclusion: Intestinal peristalsis-related streak artifacts commonly affect the left liver lobe at CT and can be substantially reduced by viewing iodine dual-energy CT image reconstructions.

7.
Eur Radiol ; 32(7): 4749-4759, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35083528

RESUMEN

OBJECTIVES: To investigate the differentiation of premalignant from benign colorectal polyps detected by CT colonography using deep learning. METHODS: In this retrospective analysis of an average risk colorectal cancer screening sample, polyps of all size categories and morphologies were manually segmented on supine and prone CT colonography images and classified as premalignant (adenoma) or benign (hyperplastic polyp or regular mucosa) according to histopathology. Two deep learning models SEG and noSEG were trained on 3D CT colonography image subvolumes to predict polyp class, and model SEG was additionally trained with polyp segmentation masks. Diagnostic performance was validated in an independent external multicentre test sample. Predictions were analysed with the visualisation technique Grad-CAM++. RESULTS: The training set consisted of 107 colorectal polyps in 63 patients (mean age: 63 ± 8 years, 40 men) comprising 169 polyp segmentations. The external test set included 77 polyps in 59 patients comprising 118 polyp segmentations. Model SEG achieved a ROC-AUC of 0.83 and 80% sensitivity at 69% specificity for differentiating premalignant from benign polyps. Model noSEG yielded a ROC-AUC of 0.75, 80% sensitivity at 44% specificity, and an average Grad-CAM++ heatmap score of ≥ 0.25 in 90% of polyp tissue. CONCLUSIONS: In this proof-of-concept study, deep learning enabled the differentiation of premalignant from benign colorectal polyps detected with CT colonography and the visualisation of image regions important for predictions. The approach did not require polyp segmentation and thus has the potential to facilitate the identification of high-risk polyps as an automated second reader. KEY POINTS: • Non-invasive deep learning image analysis may differentiate premalignant from benign colorectal polyps found in CT colonography scans. • Deep learning autonomously learned to focus on polyp tissue for predictions without the need for prior polyp segmentation by experts. • Deep learning potentially improves the diagnostic accuracy of CT colonography in colorectal cancer screening by allowing for a more precise selection of patients who would benefit from endoscopic polypectomy, especially for patients with polyps of 6-9 mm size.


Asunto(s)
Pólipos del Colon , Colonografía Tomográfica Computarizada , Neoplasias Colorrectales , Aprendizaje Profundo , Lesiones Precancerosas , Anciano , Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Colonoscopía , Neoplasias Colorrectales/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Lesiones Precancerosas/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Diagnostics (Basel) ; 11(7)2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34359354

RESUMEN

BACKGROUND: Neurologic symptom severity and deterioration at 24 hours (h) predict long-term outcomes in patients with acute large vessel occlusion (LVO) stroke of the anterior circulation. We aimed to examine the association of baseline multiparametric CT imaging and clinical factors with the course of neurologic symptom severity in the first 24 h after endovascular treatment (EVT). METHODS: Patients with LVO stroke of the anterior circulation were selected from a prospectively acquired consecutive cohort of patients who underwent multiparametric CT, including non-contrast CT, CT angiography and CT perfusion before EVT. The symptom severity was assessed on admission and after 24 h using the 42-point National Institutes of Health Stroke Scale (NIHSS). Clinical and imaging data were compared between patients with and without early neurological deterioration (END). END was defined as an increase in ≥4 points, and a significant clinical improvement as a decrease in ≥4 points, compared to NIHSS on admission. Multivariate regression analyses were used to determine independent associations of imaging and clinical parameters with NIHSS score increase or decrease in the first 24 h. RESULTS: A total of 211 patients were included, of whom 38 (18.0%) had an END. END was significantly associated with occlusion of the internal carotid artery (odds ratio (OR), 4.25; 95% CI, 1.90-9.47) and the carotid T (OR, 6.34; 95% CI, 2.56-15.71), clot burden score (OR, 0.79; 95% CI, 0.68-0.92) and total ischemic volume (OR, 1.01; 95% CI, 1.00-1.01). In a comprehensive multivariate analysis model including periprocedural parameters and complications after EVT, carotid T occlusion remained independently associated with END, next to reperfusion status and intracranial hemorrhage. Favorable reperfusion status and small ischemic core volume were associated with clinical improvement after 24 h. CONCLUSIONS: The use of imaging parameters as a surrogate for early NIHSS progression in an acute LVO stroke after EVT reached limited performance with only carotid T occlusion as an independent predictor of END. Reperfusion status and early complications in terms of intracranial hemorrhage are critical factors that influence patient outcome in the acute stroke phase after EVT.

9.
Artículo en Inglés | MEDLINE | ID: mdl-34183320

RESUMEN

INTRODUCTION: As white matter hyperintensities (WMHs) of the brain are associated with an increased risk of stroke, cognitive decline, and depression, elucidating the associated risk factors is important. In addition to age and hypertension, pre-diabetes and diabetes may play important roles in the development of WMHs. Previous studies have, however, shown conflicting results. We aimed to investigate the effect of diabetes status and quantitative markers of glucose metabolism on WMH volume in a population-based cohort without prior cardiovascular disease. RESEARCH DESIGN AND METHODS: 400 participants underwent 3 T MRI. WMHs were manually segmented on 3D fluid-attenuated inversion recovery images. An oral glucose tolerance test (OGTT) was administered to all participants not previously diagnosed with diabetes to assess 2-hour serum glucose concentrations. Fasting glucose concentrations and glycated hemoglobin (HbA1c) levels were measured. Zero-inflated negative binomial regression analyses of WMH volume and measures of glycemic status were performed while controlling for cardiovascular risk factors and multiple testing. RESULTS: The final study population comprised 388 participants (57% male; age 56.3±9.2 years; n=98 with pre-diabetes, n=51 with diabetes). Higher WMH volume was associated with pre-diabetes (p=0.001) and diabetes (p=0.026) compared with normoglycemic control participants after adjustment for cardiovascular risk factors. 2-hour serum glucose (p<0.001), but not fasting glucose (p=0.389) or HbA1c (p=0.050), showed a significant positive association with WMH volume after adjustment for cardiovascular risk factors. CONCLUSION: Our results indicate that high 2-hour serum glucose concentration in OGTT, but not fasting glucose levels, may be an independent risk factor for the development of WMHs, with the potential to inform intensified prevention strategies in individuals at risk of WMH-associated morbidity.


Asunto(s)
Disfunción Cognitiva , Diabetes Mellitus , Estado Prediabético , Sustancia Blanca , Anciano , Diabetes Mellitus/epidemiología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estado Prediabético/epidemiología , Sustancia Blanca/diagnóstico por imagen
10.
Stroke ; 52(6): 2016-2023, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33947212

RESUMEN

Background and Purpose: Basilar artery occlusion is associated with high morbidity and mortality. Optimal imaging and treatment strategy are still controversial and prognosis estimation challenging. We, therefore, aimed to determine the predictive value of computed tomography perfusion (CTP) parameters for functional outcome in patients with basilar artery occlusion in the context of endovascular treatment. Methods: Patients with basilar artery occlusion who underwent endovascular treatment were selected from a prospectively acquired cohort. Ischemic changes were assessed with the posterior-circulation Acute Stroke Prognosis Early Computed Tomography Score on noncontrast computed tomography, computed tomography angiography (CTA) source images, and CTP maps. Basilar artery on CTA score, posterior-circulation CTA score, and posterior-circulation collateral score were evaluated on CTA. Perfusion deficit volumes were quantified on CTP maps. Good functional outcome was defined as modified Rankin Scale score ≤3 at 90 days. Statistical analysis included binary logistic regressions and receiver operating characteristics analyses. Results: Among 49 patients who matched the inclusion criteria, 24 (49.0%) achieved a good outcome. In univariate analysis, age, National Institutes of Health Stroke Scale score on admission, posterior cerebral artery involvement, absence of or hypoplastic posterior communicating arteries, basilar artery on CTA score, posterior-circulation Acute Stroke Prognosis Early Computed Tomography Score, and perfusion deficit volumes on all CTP parameter maps presented significant association with functional outcome (P<0.05). In multivariate analyses, Basilar artery on CTA score, posterior-circulation Acute Stroke Prognosis Early Computed Tomography Score (odds ratio range, 1.31­2.10 [95% CI, 1.00­7.24]), and perfusion deficit volumes on all CTP maps (odds ratio range, 0.77­0.98 [95% CI, 0.63­1.00]) remained as independent outcome predictors. Cerebral blood flow deficit volume yielded the best performance for the classification of good clinical outcome with an area under the curve of 0.92 (95% CI, 0.84­0.99). Age and admission National Institutes of Health Stroke Scale had lower discriminatory power (area under the curve, <0.7). Conclusions: CTP imaging parameters contain prognostic information for functional outcome in patients with stroke due to basilar artery occlusion and may identify patients with higher risk of disability at an early stage of hospitalization.


Asunto(s)
Arteriopatías Oclusivas , Arteria Basilar , Volumen Sanguíneo Cerebral , Circulación Cerebrovascular , Angiografía por Tomografía Computarizada , Accidente Cerebrovascular , Factores de Edad , Anciano , Anciano de 80 o más Años , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/cirugía , Arteria Basilar/diagnóstico por imagen , Arteria Basilar/fisiopatología , Arteria Basilar/cirugía , Procedimientos Endovasculares , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/cirugía
11.
Nutrients ; 13(4)2021 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-33924572

RESUMEN

Subclinical effects of coffee consumption (CC) with regard to metabolic, cardiac, and neurological complications were evaluated using a whole-body magnetic resonance imaging (MRI) protocol. A blended approach was used to estimate habitual CC in a population-based study cohort without a history of cardiovascular disease. Associations of CC with MRI markers of gray matter volume, white matter hyperintensities, cerebral microhemorrhages, total and visceral adipose tissue (VAT), hepatic proton density fat fraction, early/late diastolic filling rate, end-diastolic/-systolic and stroke volume, ejection fraction, peak ejection rate, and myocardial mass were evaluated by linear regression. In our analysis with 132 women and 168 men, CC was positively associated with MR-based cardiac function parameters including late diastolic filling rate, stroke volume (p < 0.01 each), and ejection fraction (p < 0.05) when adjusting for age, sex, smoking, hypertension, diabetes, Low-density lipoprotein (LDL), triglycerides, cholesterol, and alcohol consumption. CC was inversely associated with VAT independent of demographic variables and cardiovascular risk factors (p < 0.05), but this association did not remain significant after additional adjustment for alcohol consumption. CC was not significantly associated with potential neurodegeneration. We found a significant positive and independent association between CC and MRI-based systolic and diastolic cardiac function. CC was also inversely associated with VAT but not independent of alcohol consumption.


Asunto(s)
Consumo de Bebidas Alcohólicas/epidemiología , Enfermedades Cardiovasculares/epidemiología , Ingestión de Líquidos/fisiología , Enfermedades Neurodegenerativas/epidemiología , Adiposidad/fisiología , Anciano , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/prevención & control , Café , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Corazón/diagnóstico por imagen , Corazón/fisiología , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Grasa Intraabdominal/diagnóstico por imagen , Grasa Intraabdominal/fisiología , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Enfermedades Neurodegenerativas/diagnóstico , Enfermedades Neurodegenerativas/fisiopatología , Enfermedades Neurodegenerativas/prevención & control , Factores Protectores , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Imagen de Cuerpo Entero/métodos
12.
Front Neurol ; 12: 651387, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33776900

RESUMEN

Background and Purpose: Acute ischemic stroke of the anterior circulation due to large vessel occlusion (LVO) is a multifactorial process, which causes neurologic symptoms of different degree. Our aim was to examine the impact of neuromorphologic and vascular correlates as well as clinical factors on acute symptom severity in LVO stroke. Methods: We selected LVO stroke patients with known onset time from a consecutive cohort which underwent multiparametric CT including non-contrast CT, CT angiography and CT perfusion (CTP) before thrombectomy. Software-based quantification was used to calculate CTP total ischemic and ischemic core volume. Symptom severity was assessed using the National Institutes of Health Stroke Scale (NIHSS) upon admission. Multivariable regression analysis was performed to determine independent associations of admission NIHSS with imaging and clinical parameters. Receiver operating characteristics (ROC) analyses were used to examine performance of imaging parameters to classify symptom severity. Results: We included 142 patients. Linear and ordinal regression analyses for NIHSS and NIHSS severity groups identified significant associations for total ischemic volume [ß = 0.31, p = 0.01; Odds ratio (OR) = 1.11, 95%-confidence-interval (CI): 1.02-1.19], clot burden score (ß = -0.28, p = 0.01; OR = 0.76, 95%-CI: 0.64-0.90) and age (ß = 0.17, p = 0.04). No association was found for ischemic core volume, stroke side, collaterals and time from onset. Stroke topography according to the Alberta Stroke Program CT Score template did not display significant influence after correction for multiple comparisons. AUC for classification of the NIHSS threshold ≥6 by total ischemic volume was 0.81 (p < 0.001). Conclusions: We determined total ischemic volume, clot burden and age as relevant drivers for baseline NIHSS in acute LVO stroke. This suggests that not only mere volume but also degree of occlusion influences symptom severity. Use of imaging parameters as surrogate for baseline NIHSS reached limited performance underlining the need for combined clinical and imaging assessment in acute stroke management.

13.
Radiology ; 299(2): 326-335, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33620287

RESUMEN

Background CT colonography does not enable definite differentiation between benign and premalignant colorectal polyps. Purpose To perform machine learning-based differentiation of benign and premalignant colorectal polyps detected with CT colonography in an average-risk asymptomatic colorectal cancer screening sample with external validation using radiomics. Materials and Methods In this secondary analysis of a prospective trial, colorectal polyps of all size categories and morphologies were manually segmented on CT colonographic images and were classified as benign (hyperplastic polyp or regular mucosa) or premalignant (adenoma) according to the histopathologic reference standard. Quantitative image features characterizing shape (n = 14), gray level histogram statistics (n = 18), and image texture (n = 68) were extracted from segmentations after applying 22 image filters, resulting in 1906 feature-filter combinations. Based on these features, a random forest classification algorithm was trained to predict the individual polyp character. Diagnostic performance was validated in an external test set. Results The random forest model was fitted using a training set consisting of 107 colorectal polyps in 63 patients (mean age, 63 years ± 8 [standard deviation]; 40 men) comprising 169 segmentations on CT colonographic images. The external test set included 77 polyps in 59 patients comprising 118 segmentations. Random forest analysis yielded an area under the receiver operating characteristic curve of 0.91 (95% CI: 0.85, 0.96), a sensitivity of 82% (65 of 79) (95% CI: 74%, 91%), and a specificity of 85% (33 of 39) (95% CI: 72%, 95%) in the external test set. In two subgroup analyses of the external test set, the area under the receiver operating characteristic curve was 0.87 in the size category of 6-9 mm and 0.90 in the size category of 10 mm or larger. The most important image feature for decision making (relative importance of 3.7%) was quantifying first-order gray level histogram statistics. Conclusion In this proof-of-concept study, machine learning-based image analysis enabled noninvasive differentiation of benign and premalignant colorectal polyps with CT colonography. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Neoplasias del Colon/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada , Aprendizaje Automático , Lesiones Precancerosas/diagnóstico por imagen , Anciano , Neoplasias del Colon/patología , Pólipos del Colon/patología , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Lesiones Precancerosas/parasitología , Prueba de Estudio Conceptual , Estudios Prospectivos
14.
Sci Rep ; 11(1): 2325, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33504924

RESUMEN

To identify the most important parameters associated with cerebral white matter hyperintensities (WMH), in consideration of potential collinearity, we used a data-driven machine-learning approach. We analysed two independent cohorts (KORA and SHIP). WMH volumes were derived from cMRI-images (FLAIR). 90 (KORA) and 34 (SHIP) potential determinants of WMH including measures of diabetes, blood-pressure, medication-intake, sociodemographics, life-style factors, somatic/depressive-symptoms and sleep were collected. Elastic net regression was used to identify relevant predictor covariates associated with WMH volume. The ten most frequently selected variables in KORA were subsequently examined for robustness in SHIP. The final KORA sample consisted of 370 participants (58% male; age 55.7 ± 9.1 years), the SHIP sample comprised 854 participants (38% male; age 53.9 ± 9.3 years). The most often selected and highly replicable parameters associated with WMH volume were in descending order age, hypertension, components of the social environment (i.e. widowed, living alone) and prediabetes. A systematic machine-learning based analysis of two independent, population-based cohorts showed, that besides age and hypertension, prediabetes and components of the social environment might play important roles in the development of WMH. Our results enable personal risk assessment for the development of WMH and inform prevention strategies tailored to the individual patient.


Asunto(s)
Hipertensión/fisiopatología , Aprendizaje Automático , Sustancia Blanca/fisiología , Envejecimiento/fisiología , Presión Sanguínea/fisiología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
15.
Anticancer Res ; 41(1): 437-444, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33419841

RESUMEN

BACKGROUND/AIM: Intraarterial Technetium-99m-Macroaggregated Albumin (99mTc-MAA) administration is an established method to predict particle distribution prior to radioembolization. This study aimed to analyse the impact of intraarterial administration of 99mTc-MAA on changes in liver-specific laboratory parameters and to assess whether such changes are associated with post-radioembolization hepatotoxicity. PATIENTS AND METHODS: A total of 202 patients treated with radioembolization received prior mapping angiography with 99mTc-MAA administration. All patients underwent clinical and laboratory examinations, including liver-specific parameters at certain times before and after mapping angiography/99mTc-MAA administration, as well as before radioembolization and during follow-up. RESULTS: Bilirubin increased temporarily after 99mTc-MAA administration (p<0.001), but was not clinically relevant, and returned close to the initial value before radioembolization. These changes showed no association with subsequent postradioembolic hepatotoxicity or shortened overall survival. CONCLUSION: 99mTc-MAA administration results in a significant, however, not clinically relevant transient increase in bilirubin levels, which does not provide a predictive value for subsequent radioembolization outcome or postradioembolic hepatotoxicity.


Asunto(s)
Enfermedad Hepática Inducida por Sustancias y Drogas/diagnóstico , Enfermedad Hepática Inducida por Sustancias y Drogas/etiología , Embolización Terapéutica/efectos adversos , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/terapia , Radiofármacos/efectos adversos , Agregado de Albúmina Marcado con Tecnecio Tc 99m/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Manejo de la Enfermedad , Embolización Terapéutica/métodos , Femenino , Humanos , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Pronóstico , Radiofármacos/administración & dosificación , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación , Resultado del Tratamiento
16.
Radiology ; 298(1): 135-146, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33107800

RESUMEN

Background Modern high-spatial-resolution radiologic methods enable increasingly detailed volumetric postmortem investigations of human neuroanatomy for diagnostic, research, and educational purposes. Purpose To evaluate the viability of postmortem x-ray phase-contrast micro-CT to provide tissue-conserving, high-spatial-resolution, three-dimensional neuroimaging of the human spinal cord and column by comparing quality of x-ray phase-contrast micro-CT images of nondissected Thiel-embalmed human spines with images of extracted formalin-fixed human spinal cords. Specific focus was placed on assessing the detection of micrometric spinal cord soft-tissue structure and vasculature. Materials and Methods In this study from August 2015 to August 2019, three Thiel-embalmed human spinal column samples, unilaterally perfused with an iodinated vascular contrast agent, and three extracted formalin-fixed spinal cord samples were imaged postmortem at a synchrotron radiation facility. Propagation-based x-ray phase-contrast micro-CT was used with monochromatic 60-keV x-rays and a detector with either 46-µm or 8-µm pixel sizes. A single-distance phase-retrieval algorithm was applied to the acquired CT projection images in advance of filtered back projection CT reconstruction. The influence on image quality of Thiel versus formalin embalming was examined, and images were qualitatively evaluated in terms of the value of their anatomic representations. Results The x-ray phase-contrast micro-CT of Thiel-embalmed samples resulted in soft-tissue contrast within the vertebral canal, despite evident nervous tissue deterioration after Thiel embalming. Gross spinal cord anatomy, spinal meninges, contrast agent-enhanced spinal vasculature, and spinal nerves were all well rendered alongside surrounding vertebral bone structure. The x-ray phase-contrast micro-CT of formalin-fixed boneless cords led to much higher gray versus white matter contrast and to microscale visualization of deep medullary vasculature and neuronal perikarya. Conclusion This work demonstrated the use of x-ray phase-contrast micro-CT for detailed volumetric anatomic visualization of embalmed human spines. The method provided three-dimensional display of bone, nervous tissue, and vasculature at microscale resolutions without exogenous contrast agents. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Medios de Contraste , Imagenología Tridimensional/métodos , Intensificación de Imagen Radiográfica/métodos , Médula Espinal/anatomía & histología , Microtomografía por Rayos X/métodos , Cadáver , Humanos
17.
J Int Med Res ; 48(6): 300060520930151, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32529869

RESUMEN

OBJECTIVE: Hepatocellular carcinoma (HCC) is the most common cause of primary liver cancer. A major part of diagnostic HCC work-up is based on imaging findings from sonography, computed tomography (CT), or magnetic resonance imaging (MRI) scans. Contrast-enhanced ultrasound (CEUS) allows for the dynamic assessment of the microperfusion pattern of suspicious liver lesions. This study aimed to evaluate the diagnostic value of CEUS compared with CT scans for assessing HCC. METHODS: We performed a retrospective, single-center study between 2004 and 2018 on 234 patients with suspicious liver lesions who underwent CEUS and CT examinations. All patients underwent native B-mode, color Doppler and CEUS after providing informed consent. Every CEUS examination was performed and interpreted by a single experienced radiologist (European Federation of Societies for Ultrasound in Medicine and Biology level 3). RESULTS: CEUS was performed on all included patients without occurrence of any adverse effects. CEUS showed a sensitivity of 94%, a specificity of 70%, a positive predictive value of 93% and a negative predictive value of 72% for analyzing HCC compared with CT as the diagnostic gold standard. CONCLUSIONS: CEUS has an excellent safety profile and shows a high diagnostic accuracy in assessing HCC compared with corresponding results from CT scans.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Ultrasonografía Doppler en Color/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/efectos adversos , Ultrasonografía Doppler en Color/efectos adversos , Adulto Joven
18.
Sci Rep ; 10(1): 8363, 2020 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-32433583

RESUMEN

To identify the most important factors that impact brain volume, while accounting for potential collinearity, we used a data-driven machine-learning approach. Gray Matter Volume (GMV) was derived from magnetic resonance imaging (3T, FLAIR) and adjusted for intracranial volume (ICV). 93 potential determinants of GMV from the categories sociodemographics, anthropometric measurements, cardio-metabolic variables, lifestyle factors, medication, sleep, and nutrition were obtained from 293 participants from a population-based cohort from Southern Germany. Elastic net regression was used to identify the most important determinants of ICV-adjusted GMV. The four variables age (selected in each of the 1000 splits), glomerular filtration rate (794 splits), diabetes (323 splits) and diabetes duration (122 splits) were identified to be most relevant predictors of GMV adjusted for intracranial volume. The elastic net model showed better performance compared to a constant linear regression (mean squared error = 1.10 vs. 1.59, p < 0.001). These findings are relevant for preventive and therapeutic considerations and for neuroimaging studies, as they suggest to take information on metabolic status and renal function into account as potential confounders.


Asunto(s)
Sustancia Gris/fisiología , Aprendizaje Automático , Modelos Neurológicos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/fisiopatología , Estudios de Casos y Controles , Factores de Confusión Epidemiológicos , Estudios Transversales , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 2/fisiopatología , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Tasa de Filtración Glomerular/fisiología , Sustancia Gris/diagnóstico por imagen , Humanos , Estilo de Vida , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tamaño de los Órganos/fisiología , Estado Prediabético/epidemiología , Estado Prediabético/fisiopatología , Estudios Prospectivos
19.
Med Ultrason ; 21(3): 356-358, 2019 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-31476218

RESUMEN

We present the case of splenogonadal fusion in a 53-year-old male patient assessed by ultrasound and MRI, confirmed by pathologic examination. In addition to B-mode and colour-coded Doppler ultrasound, shear wave elastography and CEUS were performed and are presented in detail. Splenogonadal fusion is a rare congenital anomaly presumably caused by an abnormal attachment of splenic tissue to the gonad during gestation. Diagnosis is challenging for clinicians and in unclear cases splenogonadal fusion might cause unnecessary orchiectomies with benign pathologic results. Ultrasound is the first-line imaging modality in the diagnosis of testicular pathologies. This case report summarizes all available modern ultrasound imagingtechnologies and highlights the possibilities for the diagnosis of splenogonadal fusion.


Asunto(s)
Medios de Contraste , Gónadas/anomalías , Gónadas/diagnóstico por imagen , Aumento de la Imagen/métodos , Bazo/anomalías , Bazo/diagnóstico por imagen , Ultrasonografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Masculino , Persona de Mediana Edad
20.
Eur J Radiol ; 85(7): 1265-70, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27235873

RESUMEN

OBJECTIVES: To determine a cut-off apparent diffusion coefficient (ADC) value distinguishing local recurrence from scar tissue in patients with rectal cancer treated with complete surgical tumour removal. METHODS: 72 patients were retrospectively included. Patients underwent 1.5T MRI including multiplanar T2-weighted turbo-spin-echo sequences (TSE) and axial single-shot epi-diffusion-weighted sequences (EPSE). Two independent observers measured mean tumour and scar tissue ADCs by manually drawing regions of interest (ROIs). The t-test and ROC analysis were used for comparison and determining an optimal discrimination threshold. As reference standard histopathological results were used in 23 patients (32%) and clinical follow-up in 49 patients (68%). RESULTS: Recurrent rectal cancer was found in 30 patients (4 female, 26 male, median age 63.13 years) and treatment related changes such as scar tissue in 42 patients (11 female, 31 male, median age 63.67 years). The mean ADC value of tumour recurrence was 1.02×10(-3)mm(2)/s (0.63-1.44×10(-3)mm(2)/s) and of scar tissue 1.77×10(-3)mm(2)/s (1.11-2.41×10(-3)mm(2)/s) showing a statistically significant difference (p<0.001). The cut-off ADC value was 1.34×10(-3)mm(2)/s with a sensitivity, specificity, and accuracy of 93%, 91%, and 92% respectively. CONCLUSIONS: Diffusion weighted MRI allows for the differentiation of tumour recurrence from scar tissue after surgical resection of rectal cancer.


Asunto(s)
Cicatriz/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Neoplasias del Recto/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Curva ROC , Neoplasias del Recto/patología , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...