Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Can J Cardiol ; 40(4): 500-523, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37820870

RESUMEN

Cardiovascular conditions are among the most frequent causes of impairment to drive, because they might induce unpredictable mental state alterations via diverse mechanisms like myocardial ischemia, cardiac arrhythmias, and vascular dysfunction. Accordingly, health professionals are often asked to assess patients' fitness to drive (FTD). The Canadian Cardiovascular Society previously published FTD guidelines in 2003-2004; herein, we present updated FTD guidelines. Because there are no randomized trials on FTD, observational studies were used to estimate the risk of driving impairment in each situation, and recommendations made on the basis of Canadian Cardiovascular Society Risk of Harm formula. More restrictive recommendations were made for commercial drivers, who spend longer average times behind the wheel, use larger vehicles, and might transport a larger number of passengers. We provide guidance for individuals with: (1) active coronary artery disease; (2) various forms of valvular heart disease; (3) heart failure, heart transplant, and left ventricular assist device situations; (4) arrhythmia syndromes; (5) implantable devices; (6) syncope history; and (7) congenital heart disease. We suggest appropriate waiting times after cardiac interventions or acute illnesses before driving resumption. When short-term driving cessation is recommended, recommendations are on the basis of expert consensus rather than the Risk of Harm formula because risk elevation is expected to be transient. These recommendations, although not a substitute for clinical judgement or governmental regulations, provide specialists, primary care providers, and allied health professionals with a comprehensive list of a wide range of cardiac conditions, with guidance provided on the basis of the level of risk of impairment, along with recommendations about ability to drive and the suggested duration of restrictions.


Asunto(s)
Sistema Cardiovascular , Enfermedad de la Arteria Coronaria , Demencia Frontotemporal , Isquemia Miocárdica , Humanos , Canadá/epidemiología , Arritmias Cardíacas/terapia
2.
CJC Open ; 5(8): 611-618, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37720184

RESUMEN

Patients with new-onset left bundle branch block (LBBB) after transcatheter aortic valve implantation (TAVI) are at risk of developing delayed high-degree atrioventricular block. Management of new-onset LBBB post-TAVI remains controversial. In the Comparison of a Clinical Monitoring Strategy Versus Electrophysiology-Guided Algorithmic Approach in Patients With a New LBBB After TAVI (COME-TAVI) trial, consenting patients with new-onset LBBB that persists on day 2 after TAVI, meeting exclusion/inclusion criteria, are randomized to an electrophysiological study (EPS)-guided approach or 30-day electrocardiographic monitoring. In the EPS-guided approach, patients with a His to ventricle (HV) interval ≥ 65 ms undergo permanent pacemaker implantation. Patients randomized to noninvasive monitoring receive a wearable continuous electrocardiographic recording and transmitting device for 30 days. Follow-up will be performed at 3, 6, and 12 months. The primary endpoint is a composite outcome designed to capture net clinical benefit. The endpoint incorporates major consequences of both strategies in patients with new-onset LBBB after TAVI, as follows: (i) sudden cardiac death; (ii) syncope; (iii) atrioventricular conduction disorder requiring a pacemaker (for a class I or IIa indication); and (iv) complications related to the pacemaker or EPS. The trial incorporates a Bayesian design with a noninformative prior, outcome-adaptive randomization (initially 1:1), and 2 prespecified interim analyses once 25% and 50% of the anticipated number of primary endpoints are reached. The trial is event-driven, with an anticipated upper limit of 452 patients required to reach 77 primary outcome events over 12 months of follow-up. In summary, the aim of this Bayesian multicentre randomized trial is to compare 2 management strategies in patients with new-onset LBBB post-TAVI-an EPS-guided approach vs noninvasive 30-day monitoring. Trial registration number: NCT03303612.


Les patients chez qui un bloc de branche gauche (BBG) est récemment apparu à la suite de l'implantation valvulaire aortique par cathéter (IVAC) présentent un risque de bloc auriculoventriculaire de haut degré tardif. La prise en charge d'un BBG récemment apparu après une IVAC demeure controversée. Dans le cadre de l'essai COME-TAVI (Comparison of a ClinicalMonitoring Strategy VersusElectrophysiology-Guided Algorithmic Approach in Patients With a New LBBB AfterTAVI, ou comparaison d'une stratégie de surveillance clinique, par rapport à une approche guidée par étude électrophysiologique et fondée sur un algorithme, chez des patients présentant un BBG d'apparition récente à la suite d'une IVAC), des patients qui présentent un BBG d'apparition récente persistant le 2e jour après une IVAC, qui répondent aux critères d'admissibilité et qui ont donné leur consentement sont répartis aléatoirement pour être suivis à l'aide d'une approche guidée par une étude électrophysiologique (EEP) ou faire l'objet d'une surveillance électrocardiographique d'une durée de 30 jours. Un stimulateur cardiaque est implanté chez les patients du groupe de l'EEP dont l'intervalle HV (temps de conduction dans le tronc du faisceau de His jusqu'aux ventricules) est ≥ 65 ms. Les patients du groupe de surveillance non invasive reçoivent un dispositif portable d'enregistrement et de transmission continue de données électrocardiographiques pour une période de 30 jours. Le suivi sera réalisé aux 3e, 6e et 12e mois. Le critère d'évaluation principal est un paramètre composite conçu afin de saisir le bienfait clinique net. Il comprend les conséquences majeures des deux stratégies chez les patients présentant un BBG d'apparition récente après une IVAC, comme suit : (i) mort subite d'origine cardiaque; (ii) syncope; (iii) trouble de la conduction auriculoventriculaire nécessitant la pose d'un stimulateur cardiaque (pour une indication de classe I ou IIa); et (iv) complications relatives au stimulateur cardiaque ou à l'EEP. L'essai intègre une conception bayésienne avec une répartition aléatoire (dans un rapport initial de 1:1) antérieure non informative adaptée aux résultats et deux analyses intermédiaires définies au préalable lorsque 25 % et 50 % du nombre anticipé des critères d'évaluation principaux seront atteints. L'essai est axé sur les événements, et la limite supérieure anticipée pour atteindre 77 événements relatifs aux critères d'évaluation principaux sur 12 mois de suivi est de 452 patients. En résumé, l'objectif de cet essai bayésien multicentrique à répartition aléatoire est de comparer deux stratégies de prise en charge de patients présentant un BBG d'apparition récente après une IVAC, soit une approche guidée par une EEP, par rapport à une surveillance non invasive de 30 jours. Trial registration number: NCT03303612.

3.
Heart Rhythm O2 ; 3(5): 560-567, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36340481

RESUMEN

Background: The identification of low-voltage proarrhythmic areas for catheter ablation of scar-mediated ventricular tachycardia (VT) remains challenging. Integration of myocardial perfusion imaging (single-photon emission computed tomography/computed tomography; SPECT/CT) and electroanatomical mapping (EAM) may improve delineation of the arrhythmogenic substrate. Objective: To assess the feasibility of SPECT/CT image integration with voltage maps using the EnSite Precision system (Abbott) in patients undergoing scar-mediated VT ablation. Methods: Patients underwent SPECT/CT imaging prior to left ventricular (LV) EAM with the EnSite Precision mapping system. The SPECT/CT, EAM data, and ablation lesions were retrospectively co-registered in the EnSite Precision system and exported for analysis. Segmental tissue viability scores were calculated based on SPECT/CT perfusion and electrogram bipolar voltage amplitude. Concordance, specificity, and sensitivity between the 2 modalities as well as the impact of SPECT/CT spatial resolution were evaluated. Results: Twenty subjects (95% male, 67 ± 7 years old, left ventricular ejection fraction 36% ± 11%) underwent EAM and SPECT/CT integration. A concordance of 70% was found between EAM and SPECT/CT for identification of cardiac segments as scar vs viable, with EAM showing a 68.5% sensitivity and 76.4% specificity when using SPECT/CT as a gold standard. Projection on low-resolution 3D geometries led to an average decrease of 38% ± 22% of the voltage points used. Conclusion: The study demonstrated the feasibility of integrating SPECT/CT with EAM performed retrospectively for characterization of anatomical substrates during VT ablation procedures.

4.
Eur Heart J ; 43(32): 3071-3081, 2022 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-35352813

RESUMEN

AIMS: Genetic testing is recommended in specific inherited heart diseases but its role remains unclear and it is not currently recommended in unexplained cardiac arrest (UCA). We sought to assess the yield and clinical utility of genetic testing in UCA using whole-exome sequencing (WES). METHODS AND RESULTS: Survivors of UCA requiring external defibrillation were included from the Cardiac Arrest Survivor with Preserved Ejection fraction Registry. Whole-exome sequencing was performed, followed by assessment of rare variants in previously reported cardiovascular disease genes. A total of 228 UCA survivors (mean age at arrest 39 ± 13 years) were included. The majority were males (66%) and of European ancestry (81%). Following advanced clinical testing at baseline, the likely aetiology of cardiac arrest was determined in 21/228 (9%) cases. Whole-exome sequencing identified a pathogenic or likely pathogenic (P/LP) variant in 23/228 (10%) of UCA survivors overall, increasing the proportion of 'explained' cases from 9% only following phenotyping to 18% when combining phenotyping with WES. Notably, 13 (57%) of the 23 P/LP variants identified were located in genes associated with cardiomyopathy, in the absence of a diagnosis of cardiomyopathy at the time of arrest. CONCLUSIONS: Genetic testing identifies a disease-causing variant in 10% of apparent UCA survivors. The majority of disease-causing variants was located in cardiomyopathy-associated genes, highlighting the arrhythmogenic potential of such variants in the absence of an overt cardiomyopathy diagnosis. The present study supports the use of genetic testing including assessment of arrhythmia and cardiomyopathy genes in survivors of UCA.


Asunto(s)
Cardiomiopatías , Paro Cardíaco , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/genética , Femenino , Pruebas Genéticas/métodos , Corazón , Paro Cardíaco/etiología , Humanos , Masculino
5.
Can J Cardiol ; 37(11): 1857-1860, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34571165

RESUMEN

Physicians engaged in cardiovascular implantable electronic device (CIED)-related practice come from diverse training backgrounds with variable degrees of CIED implant training. The objective of the Canadian Heart Rhythm Society Task Force on CIED Implant Training was to establish a common structure and content for training programs in CIED implantation, related activities and maintenance of competency. This executive summary presents the essence of the report with key recommendations included, with the complete version made available in a linked supplement. The goals are to ensure that future generations of CIED implanters are better prepared for continuously evolving CIED practice and quality care for all Canadians.


Asunto(s)
Comités Consultivos/estadística & datos numéricos , Cardiología/educación , Desfibriladores Implantables , Educación de Postgrado en Medicina/métodos , Marcapaso Artificial , Médicos/normas , Sociedades Médicas , Arritmias Cardíacas/terapia , Canadá , Competencia Clínica/normas , Cardioversión Eléctrica/normas , Electrónica , Guías como Asunto , Humanos
6.
Can J Cardiol ; 37(6): 835-847, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34154798

RESUMEN

Magnetic resonance imaging (MRI) is often considered the gold-standard test for characterizing cardiac as well as noncardiac structure and function. However, many patients with cardiac implantable electronic devices (CIEDs) and/or severe renal dysfunction are unable to undergo this test because of safety concerns. In the past 10 years, newer-generation CIEDs and gadolinium-based contrast agents (GBCAs) as well as coordinated care between imaging and heart rhythm device teams have mitigated risk to patients and improved access to MRI at many hospitals. The purpose of this statement is to review published data on safety of MRI in patients with conditional and nonconditional CIEDs in addition to patient risks from older and newer GBCAs. This statement was developed through multidisciplinary collaboration of pan-Canadian experts after a relevant and independent literature search by the Canadian Agency for Drugs and Technologies in Health. All recommendations align with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Key recommendations include: (1) the development of standardized protocols for patients with a CIED undergoing MRI; (2) patients with MRI nonconditional pacemakers and pacemaker dependency should be programmed to asynchronous mode and those with MRI nonconditional transvenous defibrillators should have tachycardia therapies turned off during the scan; and (3) macrocyclic or newer linear GBCAs should be used in preference to older GBCAs because of their better safety profile in patients at higher risk of nephrogenic systemic fibrosis.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Imagen por Resonancia Magnética/métodos , Pautas de la Práctica en Medicina , Ajuste de Riesgo/métodos , Canadá , Protocolos Clínicos/normas , Desfibriladores Implantables/efectos adversos , Humanos , Aumento de la Imagen/métodos , Invenciones/normas , Invenciones/tendencias , Imagen por Resonancia Magnética/tendencias , Marcapaso Artificial/efectos adversos , Seguridad del Paciente/normas , Pautas de la Práctica en Medicina/organización & administración , Pautas de la Práctica en Medicina/tendencias , Mejoramiento de la Calidad
7.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33157186

RESUMEN

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter/efectos adversos , Angiografía por Resonancia Magnética , Complicaciones Posoperatorias , Venas Pulmonares , Estenosis de Vena Pulmonar , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Canadá/epidemiología , Ablación por Catéter/métodos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Femenino , Humanos , Incidencia , Angiografía por Resonancia Magnética/métodos , Angiografía por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Evaluación de Resultado en la Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/patología , Venas Pulmonares/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad , Estenosis de Vena Pulmonar/diagnóstico , Estenosis de Vena Pulmonar/epidemiología , Estenosis de Vena Pulmonar/etiología , Estenosis de Vena Pulmonar/fisiopatología
8.
Osteoporos Sarcopenia ; 6(3): 139-145, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33102808

RESUMEN

OBJECTIVES: Sarcopenia is a decline in skeletal muscle mass and function. It is associated with adverse outcomes and increased mortality. Sarcopenia is also reported to be prevalent in the hip fracture population. Our aims in this study are to compare the hormonal profile in women with hip fracture to controls, and to assess the relationship between hormonal biomarkers to skeletal muscle mass and function in these women. METHODS: A cross sectional study was performed enrolling women above age 60 years old with hip fracture as a study group. For comparison healthy women from the community were recruited. Peripheral blood samples were obtained for analysis of hormonal profiles. Measures of skeletal muscle mass and function by muscle area on computed tomography, dual energy X-ray absorptiometry, bioelectrical impedance analysis, and grip strength was performed. RESULTS: A high proportion of sarcopenic individuals were detected in the hip fracture group (60%). Women with hip fracture compared to controls were older (P = 0.073), had lower serum albumin levels (P < 0.001), serum insulin-like growth factor-1 (IGF-1) (P < 0.001), insulin-like growth factor binding protein -3 (IGFBP-3) (P < 0.001), free testosterone levels (P = 0.001), and impaired beta cell function by homeostasis model assessment (HOMA beta) (P = 0.038). CONCLUSIONS: There is a high proportion of sarcopenic individuals in the hip fracture group. Lowered serum levels of IGF-1 and IGFBP-3, HOMA beta cell function, and free testosterone levels were detected in this group and may serve as potential biomarkers of sarcopenia.

9.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32374963

RESUMEN

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Equipo Reutilizado , Infecciones/etiología , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Estudios de Casos y Controles , Países en Desarrollo , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Infecciones/epidemiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Mortalidad , Factores de Riesgo , Esterilización
10.
Can J Cardiol ; 35(8): 1069-1077, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31376908

RESUMEN

BACKGROUND: Compelling evidence showing a link between atrial fibrillation (AF) and cognitive decline and dementia is accumulating. METHODS: Blinded Randomized Trial of Anticoagulation to Prevent Ischemic Stroke and Neurocognitive Impairment in Atrial Fibrillation (BRAIN-AF) is a prospective, multicentric, double-blind, randomized-controlled trial, recruiting patients with nonvalvular AF and a low risk of stroke. Patients with a high risk of bleeding will be excluded from the study. Participants will be randomized to receive either rivaroxaban (15 mg daily) or standard of care (placebo in patients without vascular disease or acetylsalicylic acid 100 mg daily in patients with vascular disease). RESULTS: The primary outcome is the composite of stroke, transient ischemic attack, and cognitive decline (defined by a decrease in the Montreal Cognitive Assessment score ≥ 3 at any follow-up visit after baseline). Approximately 3250 patients will be enrolled in approximately 130 clinical sites until 609 adjudicated primary outcome events have occurred. CONCLUSIONS: BRAIN-AF determines whether oral anticoagulation therapy with rivaroxaban compared with standard of care reduces the risk of stroke, transient ischemic attack, or cognitive decline in patients with nonvalvular AF and a low risk of stroke.


Asunto(s)
Fibrilación Atrial , Isquemia Encefálica , Disfunción Cognitiva , Rivaroxabán , Accidente Cerebrovascular , Administración Oral , Adulto , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Coagulación Sanguínea/efectos de los fármacos , Isquemia Encefálica/etiología , Isquemia Encefálica/prevención & control , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/etiología , Disfunción Cognitiva/prevención & control , Método Doble Ciego , Monitoreo de Drogas/métodos , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/efectos adversos , Femenino , Humanos , Masculino , Pruebas de Estado Mental y Demencia , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Rivaroxabán/administración & dosificación , Rivaroxabán/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
11.
Can J Cardiol ; 35(7): 840-845, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31292082

RESUMEN

BACKGROUND: Atrial fibrillation (AF), which affects 1% to 4% of the general population, is an important risk factor for stroke. New technologies for AF screening are now available, but their real-world application in clinical settings has not yet been thoroughly investigated. The aim of this project was to describe the introduction and feasibility of a mobile electrocardiogram (ECG) device for AF screening in a large-scale, undifferentiated population. METHODS: A total of 184 Canadian primary care physicians were provided with a KardiaMobile ECG device (AliveCor) for 3 months. Physicians were asked to obtain a single 30-second ECG recording of all patients seen in their daily practice who were ≥65 years old and not previously diagnosed with AF. Evaluation of the Kardia device by physicians was measured using a Likert scale-based questionnaire. RESULTS: One hundred thirty-three physicians (72%) reported their findings and completed the survey. A total of 7585 patients were screened (42% of eligible patients). AF was detected in 471 patients (6.2%). Anticoagulation therapy was initiated in 270 patients (57%). Physicians generally reported a high perceived clinical value (94%) and ease of integration (89%) of the device. CONCLUSIONS: Previously undiagnosed AF is common in older individuals attending primary care clinics. The KardiaMobile ECG device appears to be an effective screening tool for AF with high physician acceptability. More research on the feasibility of such novel technologies is warranted for future consideration of integration in population-based screening programs.


Asunto(s)
Instituciones de Atención Ambulatoria , Fibrilación Atrial/diagnóstico , Electrocardiografía/instrumentación , Aplicaciones Móviles , Atención Primaria de Salud , Teléfono Inteligente , Anciano , Actitud del Personal de Salud , Estudios de Factibilidad , Humanos , Ontario , Quebec , Encuestas y Cuestionarios
12.
Expert Rev Cardiovasc Ther ; 16(7): 489-500, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29912584

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is the most frequent arrhythmia worldwide. While mostly seen in elderly, it can also affect young adults (≤ 45 years of age), older adolescent, and children. Areas covered: The aim of this review is to provide an overview of the current management of AF in young patients. Specific issues arise over diagnostic workup as well as antiarrhythmic and anticoagulation therapies. The future management and diagnostic strategies are also discussed. Expert commentary: Management of AF in the young adult is largely extrapolated from adult studies and guidelines. In this population, AF could reveal a genetic pathology (e.g. Brugada, Long QT or Short QT syndromes) or be the initial presentation of a cardiomyopathy. Therefore, thorough workup in the young population to eliminate potential malignant pathology.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Terapia Trombolítica/métodos , Adolescente , Adulto , Niño , Humanos , Adulto Joven
13.
SAGE Open Med ; 6: 2050312118769797, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29770216

RESUMEN

OBJECTIVES: Cryoablation is an effective alternative treatment for cardiac arrhythmias offering shortened recovery and reduced side effects. As the use of cryoablation increases, the need for new devices and procedures has emerged. This has been driven by technological limitations including lengthy periods to generate a single lesion (3-5 min), uncertain transmurality, and differential efficacy. Furthermore, due to limited ablation capacity under high heat loads, cryo has had limited success in the treatment of ventricular arrhythmias. To this end, in this study we evaluated a new cryoablation catheter, ICEolate, for the targeted ablation of cardiac tissue. METHODS: Performance assessment included calorimetry, freeze zone isothermal distribution characterization and catheter ablation capacity in a submerged, circulating, heat-loaded ex vivo tissue model. A pilot in vivo study was also conducted to assess ablative capacity of the cryocatheter in a fully beating heart. RESULTS: Ex vivo studies demonstrated ice formation at the tip of a cryocatheter within 5 s and a tip temperature of ~-150°C within 10 s. The device repeatedly generated freeze zones of 2 cm × 3 cm in less than 2 min. Tissue model studies revealed the generation of a full thickness (5-10 mm) cryogenic lesion within 1 min with an opposite (transmural) surface temperature of <-60°C under a circulating 37°C heat load. Pilot in vivo studies demonstrated the delivery of an ablative "dose," producing a continuous full thickness transmural linear lesion in <60 s at both atrial and ventricular sites. CONCLUSION: These studies suggest that the supercritical nitrogen cryodevice and ICEolate cryocatheter may provide for rapid, effective, controllable freezing of targeted tissue. The ablative power, speed, and directional freeze characteristics also offer the potential of improved safety via a reduction in procedural time compared to current cryoablation devices. These technological developments may open new avenues for the application of cryo to treat other cardiac arrhythmogenic disorders.

15.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29064134

RESUMEN

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Asunto(s)
Cateterismo Cardíaco/métodos , Técnicas Electrofisiológicas Cardíacas , Exposición Profesional/prevención & control , Implantación de Prótesis/métodos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Humanos , Exposición Profesional/efectos adversos , Salud Laboral , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Factores Protectores , Exposición a la Radiación/efectos adversos , Protección Radiológica , Radiografía Intervencional/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
16.
Europace ; 19(2): 329-331, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28172643

RESUMEN

We report a case in which a novel three-dimensional (3D) electromagnetic cardiovascular navigation system (MediGude™, St. Jude Medical, St. Paul, MN, USA) was used to create a 3D reconstruction of the axillary vein and its anatomic course to guide its successful puncture and cannulation. The MediGuide system's projection accuracy has proved to offer a level of precision that is sufficient to achieve axillary vein access. This highlights its enormous possibilities to obtain 3D venous system reconstruction with minimal fluoroscopic use when performing cardiac or even non-cardiac procedures.


Asunto(s)
Vena Axilar/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Imagenología Tridimensional/métodos , Implantación de Prótesis/métodos , Vena Subclavia/diagnóstico por imagen , Humanos , Flebografía , Prueba de Estudio Conceptual
17.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28233925

RESUMEN

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Asunto(s)
Cateterismo Cardíaco/métodos , Frío , Criocirugía/métodos , Atrios Cardíacos/cirugía , Ventrículos Cardíacos/cirugía , Óxido Nitroso/farmacología , Animales , Perros , Atrios Cardíacos/patología , Ventrículos Cardíacos/patología , Modelos Animales , Factores de Tiempo
18.
JACC Heart Fail ; 5(2): 99-106, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28089316

RESUMEN

OBJECTIVES: The impact of beta-blockers on mortality and hospitalizations was assessed in the largest randomized trial of patients with both atrial fibrillation (AF) and heart failure with a reduced ejection fraction (HFrEF): the Atrial Fibrillation-Congestive Heart Failure trial. BACKGROUND: Although beta-blockers are the cornerstone of therapy for HFrEF, a recent patient-level meta-analysis cast doubt on their efficacy in patients with coexisting AF. METHODS: From a total of 1,376 subjects randomized in the AF-CHF trial, those without beta-blockers at baseline were propensity matched to a maximum of 2 exposed patients. All absolute standardized differences after matching were ≤10%. Primary analyses respected the intention-to-treat principle. In on-treatment sensitivity analyses, beta-blocker status was modeled as a time-dependent covariate. RESULTS: Baseline characteristics were comparable among the matched cohorts (mean age 70 ± 11 years, 81% male, and mean left ventricular ejection fraction 27 ± 6%). During a median follow-up of 37 months, beta-blockers were associated with significantly lower all-cause mortality (hazard ratio [HR]: 0.721, 95% confidence interval [CI]: 0.549 to 0.945; p = 0.0180) but not hospitalizations (HR: 0.886; 95% CI: 0.715 to 1.100; p = 0.2232). Similar results were obtained in sensitivity analyses that modeled beta-blockers as a time-dependent variable (HR: 0.668 for all-cause mortality; 95% CI: 0.511 to 0.874; p = 0.0032; HR: 0.814 for hospitalizations; 95% CI: 0.653 to 1.014; p = 0.0658). There were no significant interactions between beta-blockers and patterns (i.e., persistent vs. paroxysmal) or burden of AF with respect to mortality or hospitalizations. CONCLUSIONS: In propensity-matched analyses, beta-blockers were associated with significantly lower mortality but not hospitalizations in patients with HFrEF and AF, irrespective of the pattern or burden of AF. These results support current evidence-based recommendations for beta-blockers in patients with HFrEF, whether or not they have associated AF.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Fibrilación Atrial/epidemiología , Insuficiencia Cardíaca/tratamiento farmacológico , Hospitalización/estadística & datos numéricos , Mortalidad , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Causas de Muerte , Comorbilidad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Factores Protectores , Ensayos Clínicos Controlados Aleatorios como Asunto , Volumen Sistólico
19.
Europace ; 19(6): 1043-1048, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27377075

RESUMEN

AIMS: It remains unknown whether contact force (CF) sensing technology is of value for cavotricuspid isthmus (CTI) ablation. We prospectively evaluated procedural parameters and outcomes of CF-guided vs. CF-blinded CTI ablation for typical atrial flutter (AFL). METHODS AND RESULTS: A total of 70 consecutive patients (62.5 ± 10.9 years) undergoing CTI ablation for AFL were prospectively enrolled, 35 in CF-blinded and 35 in CF-guided groups. A CF-sensing catheter (power 25-35 W) was used in all. In the CF-guided group, CF target range was 10-25 g, whereas in the CF-blinded group, the operator was blinded to CF. The isthmus was divided into anterior, middle, and posterior segments for region-specific CF analysis. The procedural endpoint of bidirectional isthmus block following a 20-min observation period was achieved in all. A trend towards lower fluoroscopy and procedure duration was observed when the CF-guided group was compared with the CF-blinded group. The total radiofrequency (RF) energy delivery time required to achieve bidirectional block was significantly lower in the CF-guided vs. CF-blinded group [10.0 min (IQR 8.3;15.1) vs. 15.9 min (IQR 9.6;24.7), P= 0.0020], with a significant inverse correlation between CF and total RF delivery time (r = -0.36; P= 0.0027). Mean CF measurements significantly increased from anterior to posterior anatomical zones of CTI in the CF-blinded group (ANOVA P= 0.0466). CONCLUSIONS: Catheter ablation of AFL guided by real-time CF assessment results in a significant reduction in total RF delivery time. Real-time CF measurements facilitate the maintenance of homogenous efficient contact all along the CTI, particularly in the anterior segment where CF is generally lower.


Asunto(s)
Aleteo Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Transductores de Presión , Potenciales de Acción , Anciano , Análisis de Varianza , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Distribución de Chi-Cuadrado , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
Stand Genomic Sci ; 11: 88, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27980706

RESUMEN

Chlorinated solvent contamination of potable water supplies is a serious problem worldwide. Biostimulation protocols can successfully remediate chlorinated solvent contamination through enhanced reductive dechlorination pathways, however the process is poorly understood and sometimes stalls creating a more serious problem. Whole metagenome techniques have the potential to reveal details of microbial community changes induced by biostimulation. Here we compare the metagenome of a tetrachloroethene contaminated Environmental Protection Agency Superfund Site before and after the application of biostimulation protocols. Environmental DNA was extracted from uncultured microbes that were harvested by on-site filtration of groundwater one month prior to and five months after the injection of emulsified vegetable oil, nutrients, and hydrogen gas bioamendments. Pair-end libraries were prepared for high-throughput DNA sequencing and 90 basepairs from both ends of randomly fragmented 400 basepair DNA fragments were sequenced. Over 31 millions reads were annotated with Metagenome Rapid Annotation using Subsystem Technology representing 32 prokaryotic phyla, 869 genera, and 3,181 species. A 3.6 log2 fold increase in biomass as measured by DNA yield per mL water was measured, but there was a 9% decrease in the number of genera detected post-remediation. We apply Bayesian statistical methods to assign false discovery rates to fold-change abundance data and use Zipf's power law to filter genera with low read counts. Plotting the log-rank against the log-fold-change facilitates the visualization of the changes in the community in response to the enhanced reductive dechlorination protocol. Members of the Archaea domain increased 4.7 log2 fold, dominated by methanogens. Prior to remediation, classes Alphaproteobacteria and Betaproteobacteria dominated the community but exhibit significant decreases five months after biostimulation. Geobacter and Sulfurospirillum replace "Sideroxydans" and Burkholderia as the most abundant genera. As a result of biostimulation, Deltaproteobacteria and Epsilonproteobacteria capable of dehalogenation, iron and sulfate reduction, and sulfur oxidation increase. Matches to thermophilic, haloalkane respiring archaea is evidence for additional species involved in biodegradation of chlorinated solvents. Additionally, potentially pathogenic bacteria increase, indicating that there may be unintended consequences of bioremediation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA