Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 478: 135518, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39154474

RESUMEN

The solid culture method for measuring the efficiency of ultraviolet (UV) disinfection of airborne bacteria is time-consuming, typically taking 12-48 h. To expedite such experiments, this study proposed a liquid culture method assisted by adenosine triphosphate (ATP) analysis, as a liquid culture is faster than a solid culture, and measurement of ATP does not require waiting for visible colonies to form. Escherichia coli (E. coli) was used as the experimental bacterium. This study first compared the log reduction of bacteria in liquid as measured by the proposed method and by the traditional solid culture method. The minimum liquid culture time was determined for different bacterial concentration ranges. Finally, the feasibility of the proposed method was validated by UV disinfection experiments on airborne bacteria. The results indicated that the proposed method measured a similar log reduction to that of the solid culture method in liquid experiments. The minimum liquid culture time for E. coli in 105-106 colony forming units (CFU)/mL was 2 h. The validation experiments demonstrated that the proposed method is capable of measuring the UV disinfection efficiency of airborne bacteria. The proposed method can accelerate laboratory experiments on UV disinfection of airborne bacteria, which in turn can support the effective design and utilization of UV disinfection in real life.

2.
Sci Total Environ ; 912: 168803, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38000739

RESUMEN

Far-ultraviolet C (far-UVC) light is an effective and safe disinfection method for bioaerosol control in occupied indoor environments. The installation location of a far-UVC lamp strongly influences the spatial distribution of far-UVC irradiance, and thus the effectiveness of bioaerosol disinfection. To assist the design process, this study developed a fast prediction approach based on the Markov chain model for optimizing the installation locations of far-UVC lamps in order to enhance the disinfection effectiveness for indoor bioaerosol control. Experiments were conducted in an environmental chamber to validate the proposed simulation-based optimization approach. The results show that the proposed method can correctly predict the disinfection efficiency when compared with experimental data, and optimizing the installation location of the far-UVC lamp increased the disinfection efficiency by 54 % compared with the worst location. As an application, the validated method was then used to design the installation location of a far-UVC lamp in a real conference room. The results show that installing the far-UVC lamp in the optimal location can increase the disinfection efficiency by 48 % compared with the worst installation location. Therefore, optimizing the far-UVC lamp location using the proposed Markov chain model can enhance the effectiveness of bioaerosol disinfection in indoor environments.


Asunto(s)
Desinfección , Rayos Ultravioleta , Desinfección/métodos , Cadenas de Markov
3.
J Hazard Mater ; 465: 133358, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38157810

RESUMEN

Far-ultraviolet C (UVC) light has demonstrated its ability to inactivate microbes on surfaces. However, the factors influencing the efficacy of far-UVC surface disinfection remain unclear. This study aimed to explore the effects of material properties on far-UVC disinfection of bioaerosols (represented by Escherichia coli (E. coli)) deposited on surfaces. The susceptibility constants (Z-values) of E. coli on 14 common materials were measured and analyzed. Additionally, five possible influencing factors (roughness, pores, electrostatic charge, wetness, and temperature) related to surface properties were investigated by control experiments. The results show that far-UVC light effectively disinfected E. coli on the 14 materials, with disinfection efficiencies ranging from 69.1% to 98.9% under a dose of 100.8 J/m2. Surface roughness and electrostatic charges had negligible influence on far-UVC disinfection of E. coli on surfaces. However, for porous materials, pore sizes larger than the E. coli size resulted in lower Z-values. Higher surface wetness decreased both the Z-value and natural decay rate. Meanwhile, a higher surface temperature of 40 °C resulted in a higher Z-value and natural decay rate. The results can improve our understanding of far-UVC disinfection of microbes on surfaces, and the database can be used for numerical models.


Asunto(s)
Desinfección , Escherichia coli , Desinfección/métodos , Rayos Ultravioleta
4.
Lancet Planet Health ; 7(11): e900-e911, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37940210

RESUMEN

BACKGROUND: High-level exposure to indoor air pollutants (IAPs) and their corresponding adverse health effects have become a public concern in China in the past 10 years. However, neither national nor provincial level burden of disease attributable to multiple IAPs has been reported for China. This is the first study to estimate and rank the annual burden of disease and the financial costs attributable to targeted residential IAPs at the national and provincial level in China from 2000 to 2017. METHODS: We first did a systematic review and meta-analysis of 117 articles from 37 231 articles identified in major databases, and obtained exposure-response relationships for the candidate IAPs. The exposure levels to these IAPs were then collected by another systematic review of 1864 articles selected from 52 351 articles. After the systematic review, ten IAPs with significant and robust exposure-response relationships and sufficient exposure data were finally targeted: PM2·5, nitrogen dioxide, sulphur dioxide, ozone, carbon monoxide, radon, formaldehyde, benzene, toluene, and p-dichlorobenzene. The annual exposure levels in residences were then evaluated in all 31 provinces in mainland China continuously from 2000 to 2017, using the spatiotemporal Gaussian process regression model to analyse indoor originating IAPs, and the infiltration factor method to analyse outdoor originating IAPs. The disability-adjusted life-years (DALYs) attributable to the targeted IAPs were estimated at both national and provincial levels in China, using the population attributable fraction method. Financial costs were estimated by an adapted human capital approach. FINDINGS: From 2000 to 2017, annual DALYs attributable to the ten IAPs in mainland China decreased from 4620 (95% CI 4070-5040) to 3700 (3210-4090) per 100 000. Nevertheless, in 2017, IAPs still ranked third among all risk factors, and their DALYs and financial costs accounted for 14·1% (95% CI 12·3-15·6) of total DALYs and 3·45% (3·01-3·82) of the gross domestic product. Specifically, the rank of ten targeted IAPs in order of their contribution to DALYs in 2017 was PM2·5, carbon monoxide, radon, benzene, nitrogen dioxide, ozone, sulphur dioxide, formaldehyde, toluene, and p-dichlorobenzene. The DALYs attributable to IAPs were 9·50% higher than those attributable to outdoor air pollution in 2017. For the leading IAP, PM2·5, the DALYs attributable to indoor origins are 18·3% higher than those of outdoor origins. INTERPRETATION: DALYs attributed to IAPs in China have decreased by 20·0% over the past two decades. Even so, they are still much higher than those in the USA and European countries. This study can provide a basis for determining which IAPs to target in various indoor air quality standards and for estimating the health and economic benefits of various indoor air quality control approaches, which will help to reduce the adverse health effects of IAPs in China. FUNDING: The National Key Research and Development Program of China and the National Natural Science Foundation of China.


Asunto(s)
Contaminantes Atmosféricos , Ozono , Radón , Humanos , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Monóxido de Carbono/análisis , Dióxido de Azufre/análisis , Benceno/efectos adversos , Benceno/análisis , Dióxido de Nitrógeno/efectos adversos , Dióxido de Nitrógeno/análisis , Formaldehído/análisis , Costo de Enfermedad , Material Particulado/análisis , Radón/análisis , Ozono/análisis , Tolueno/análisis
5.
J Hazard Mater ; 436: 129241, 2022 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-35739760

RESUMEN

Far-UVC with a peak wavelength of 222 nm can potentially be used to inactivate exhaled bioaerosols in an efficient and safe manner. Therefore, this study aimed to experimentally explore the effectiveness of a 222 nm far-UVC light for inactivating bioaerosols, represented by E. coli, exhaled from a manikin in a chamber with mechanical ventilation. The spatial irradiance distribution from the far-UVC light was measured. The susceptibility constant (z-value) for E. coli under the far-UVC light was experimentally obtained. The temporal and spatial concentrations of the bioaerosols exhaled from the manikin were measured under three typical ventilation rates (4, 10, and 36 ACH). According to the results, when the far-UVC light was turned on, the bioaerosol concentrations were lower than those without the far-UVC light under all three ventilation rates, suggesting that far-UVC light can effectively disinfect E. coli under mechanical ventilation. However, the disinfection efficiency of the far-UVC light decreased as the ventilation rate increased, which indicated that the far-UVC light played a more important role in bioaerosol removal under a lower ventilation rate. In general, the results supported the feasibility of using 222 nm far-UVC light for disinfection of exhaled bioaerosols in mechanically ventilated spaces to reduce infection risks.


Asunto(s)
Desinfección , Rayos Ultravioleta , Desinfección/métodos , Escherichia coli , Respiración Artificial
6.
Indoor Air ; 30(6): 1147-1165, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32845998

RESUMEN

Microbes in buildings have attracted extensive attention from both the research community and the general public due to their close relationship with human health. However, there still lacks comprehensive information on the indoor exposure level of microbes in China. This study systematically reviews exposure levels, the community structures, and the impact factors of airborne bacteria and fungi in residences, schools, and offices in China. We reviewed the major literature databases between 1980 and 2019 and selected 55 original studies based on a set of criteria. Results show that the concentration of indoor bacteria varies from 72.5 to 7500 CFU/m3 , with a median value of 1000 CFU/m3 , and the concentration of fungi varies from 12 to 9730 CFU/m3 , with a median value of 526 CFU/m3 . The concentration level of microbes varies in different climate zones, with higher bacterial concentrations in the severe cold zone, and higher fungal concentrations in the hot summer and warm winter zone. Among different buildings, classrooms have the highest average bacteria and fungi levels. This review reveals that a unified assessment system based on health effects is needed for evaluating the exposure levels of bacteria and fungi.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior/estadística & datos numéricos , Exposición a Riesgos Ambientales/estadística & datos numéricos , Bacterias , Monitoreo del Ambiente , Hongos , Vivienda , Humanos , Instituciones Académicas , Estaciones del Año , Lugar de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...