Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Pharmacol ; 15: 1414703, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38948465

RESUMEN

Esketamine nasal spray (ESK-NS) is a new drug for treatment-resistant depression, and we aimed to detect and characterize the adverse events (AEs) of ESK-NS using the Food and Drug Administration (FDA) adverse event reporting system (FAERS) database between 2019 Q1 and 2023 Q4. Reporting odds ratio (ROR), proportional reporting ratio (PRR), and multi-item gamma Poisson shrinker (MGPS) were performed to detect risk signals from the FAERS data to identify potential ESK-NS-AEs associations. A total of 14,606 reports on AEs with ESK-NS as the primary suspected drug were analyzed. A total of 518 preferred terms signals and 25 system organ classes mainly concentrated in psychiatric disorders (33.20%), nervous system disorders (16.67%), general disorders and administration site conditions (14.21%), and others were obtained. Notably, dissociation (n = 1,093, ROR 2,257.80, PRR 899.64, EBGM 876.86) exhibited highest occurrence rates and signal intensity. Moreover, uncommon but significantly strong AEs signals, such as hand-eye coordination impaired, feeling guilty, and feelings of worthlessness, were observed. Additionally, dissociative disorder (n = 57, ROR 510.92, PRR 506.70, EBGM 386.60) and sedation (n = 688, ROR 172.68, PRR 155.53, and EBGM 142.05) both presented strong AE signals, and the former is not recorded in the Summary of Product Characteristics (SmPC). In clinical applications, close attention should be paid to the psychiatric disorders and nervous system disorders, especially dissociation. Meanwhile, clinical professionals should be alert for the occurrence of AEs signals not mentioned in the SmPC and take preventive measures to ensure the safety of clinical use.

2.
Sensors (Basel) ; 22(1)2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-35009583

RESUMEN

To optically capture and analyze the structure and changes of the flow field of a weak airflow object with high accuracy, this study proposes novel weak flow field extraction methods based on background-oriented schlieren. First, a fine background pattern texture and a sensor network layout were designed to satisfy the requirement of weak flow field extraction. Second, the image displacement was extracted by calculating the correlation matrix in the frequency domain for a particle image velocimetry algorithm, and further calculations were performed for the density field using Poisson's equation. Finally, the time series baseline stacking method was proposed to obtain the flow field changes of weak airflow structures. A combustion experiment was conducted to validate the feasibility and accuracy of the proposed method. The results of a quad-rotor unmanned aerial vehicle experiment showed that the clear, uneven, and continuous quantitative laminar flow field could be obtained directly, which overcame the interference of the weak airflow, large field of view, and asymmetrical steady flow.

3.
Sensors (Basel) ; 19(19)2019 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-31546742

RESUMEN

This study presents an extrinsic Fabry-Perot interferometric (EFPI) fiber-optic strain sensor with a very short cavity. The sensor consists of two vertically cut standard single-mode fibers (SMFs) and a glass capillary with a length of several centimeters. The two SMFs penetrate into the glass capillary and are fixed at its two ends with the use of ultraviolet (UV) curable adhesives. Based on the use of the lengthy glass capillary sensitive element, the strain sensitivity can be greatly enhanced. Experiments showed that the microcavity EPFI strain sensor with initial cavity lengths of 20 µm, 30 µm, and 40 µm, and a capillary length of 40 mm, can yield respective cavity length-strain sensitivities of 15.928 nm/µÎµ, 25.281 nm/µÎµ, and 40.178 nm/µÎµ, while its linearity was very close to unity for strain measurements spanning a range in excess of 3500 µÎµ. Furthermore, the strain-temperature cross-sensitivity was extremely low.

4.
Sensors (Basel) ; 19(18)2019 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-31500318

RESUMEN

A zero-cross detection algorithm was proposed for the cavity-length interrogation of fiber-optic Fabry-Perot (FP) sensors. The method can avoid the inaccuracy of peak determination in the conventional peak-to-peak method for the cavity-length interrogation of fiber-optic FP sensors caused by the slow variation of the spectral power density in peak neighboring regions. Both simulations and experiments were carried out to investigate the feasibility and performance of the zero-cross detection algorithm. Fiber-optic FP sensors with cavity lengths in the range of 150-1000 µm were successfully interrogated with a maximum error of 0.083 µm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...