Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38809101

RESUMEN

STUDY DESIGN: This was a retrospective study combined with attempted prospective patient contact to collect current data. OBJECTIVE: The purpose of this study was to investigate long-term clinical outcome of patients undergoing lumbar hybrid surgery (total disc replacement (TDR) at one level and fusion at an adjacent level. SUMMARY OF BACKGROUND DATA: Many patients with symptomatic lumbar disc degeneration are affected at more than one level. Lumbar TDR was introduced as a fusion alternative; however, some disc levels are not amenable to TDR and fusion is preferable at such levels. Hybrid surgery was introduced as an option to fusing multiple levels. METHODS: A consecutive series of 305 patients undergoing lumbar hybrid surgery was identified beginning with the first case experience in 2005. Operative and clinical outcome data including visual analog scales (VAS) assessing back and leg pain, Oswestry Disability Index (ODI), and re-operations were collected. The mean follow-up duration was 67.1 months. RESULTS: There were statistically significant improvements (P<0.01) in the mean values of all three clinical outcome measures: VAS back pain scores improved from 6.7 to 3.3; leg pain improved from 4.3 to 2.0; and ODI scores improved from 45.5 to 24.6. There were no significant differences in pain and function scores for patients with minimum 10-year follow-up vs. those with shorter follow-up duration. Re-operation occurred in 16.1% of patients, many of which involved removal of posterior instrumentation at the fusion level (6.2% of study group, 38.8% of re-operations). Re-operation involving the TDR level occurred in 9 patients (2.9%), only 3 of which (1.0%) involved TDR removal/revision. CONCLUSION: This study supports that for many patients with multilevel symptomatic disc degeneration, hybrid surgery is a viable surgical option. Significant improvements were demonstrated in pain and function scores with no diminished improvement in scores among patients with more than 10-year follow-up.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38747243

RESUMEN

STUDY DESIGN: Retrospective cohort study. OBJECTIVE: The purpose of this study was to investigate the rate of cervical total disc replacement (TDR) device removal or revision. SUMMARY OF BACKGROUND DATA: Cervical TDR has gained acceptance as an alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. There have been concerns over device safety, one measure of which is subsequent surgery related to device problems. METHODS: A consecutive series of 1,626 cervical TDR patients from 2003 to June 2021 were included, consisting of TDRs up to 3 levels and hybrids (TDR and fusion). TDR removal or revision surgeries and reasons for these surgeries, procedures performed, and duration from index procedure were recorded. Data were analyzed to determine removal/revision rate and factors possibly related to these events. RESULTS: There were 24 removals/revisions (1.48%) in the 1,626 patients. Removal was performed in 23 cases (1.41%) and revision in 1 (0.06%). Among removal cases, ACDF was performed in 18 and TDR was replaced with another TDR in 5. Removals with fusion included 5 cases of osteolysis with/without C. acnes, 4 device displacement/migration, 4 posterior spinal pathology, and one for each of the following: metal allergy, approach-related complications, malpositioning, subsidence, and hypermobility. The revision involved TDR repositioning 3 days after index surgery. There were 66 patients for whom minimum of 10year follow-up was confirmed, and none had removal/revision surgery 10 or more years after index surgery. There was no relationship between occurrence of removal/revision and age, gender, body mass index, or physician experience (learning curve). The removal/revision rate was significantly higher in FDA trials vs. post-approval (4.1% vs. 1.3%, P<0.05). CONCLUSION: In this large consecutive series of patients, 1.48% of cervical TDRs were removed/revised. The low rate of removals/revisions over a long period of time provides support for the devices' safety.

3.
Int J Spine Surg ; 18(2): 217-221, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38471741

RESUMEN

BACKGROUND: Intraoperative neuromonitoring (IONM) became widely used in spine surgery to reduce the risk of iatrogenic nerve injury. However, the proliferation of IONM has fallen into question based on effectiveness and costs, with a lack of evidence supporting its benefit for specific spine surgery procedures. The purpose of this study was to evaluate the use of IONM and the rate of neurological injury associated with anterior lumbar spinal surgery. METHODS: This was a retrospective study on a consecutive series of 359 patients undergoing lumbar anterior approach surgery for anterior lumbar interbody fusion (ALIF), total disc replacement (TDR), or hybrid (ALIF with TDR) for the treatment of symptomatic disc degeneration. Patients undergoing any posterior spine surgery were excluded. Operative notes were reviewed to identify any changes in IONM and the surgeon's response. Clinic notes were reviewed up to 3 months postoperatively for indications of iatrogenic nerve injury. RESULTS: There were 3 aberrant results with respect to IONM. Changes in IONM of a lower extremity occurred for 1 patient (0.3%). The surgeon evaluated the situation and there was no observable reason for the IONM change. Upon waking, the patient was found to have no neurological deficit. There were 2 cases of neurologic deficits in this population, which were classified as false-negatives of IONM (0.56%, 95% CI: 0.1% to 1.8%). In both cases, the patients were found to have a foot drop after the anterior approach surgery. CONCLUSION: In this study, there was 1 false-positive and 2 false-negative results of IONM. These data suggest that IONM is not beneficial in this population. However, many surgeons may feel obligated to use IONM for medicolegal reasons. There is a need for future studies to delineate cases in which IONM is beneficial and the type of monitoring to use, if any, for specific spine surgery types. CLINICAL RELEVANCE: This study questions the routine use of IONM in anterior lumbar approach surgery for the treatment of symptomatic disc degeneration. This has significant implications related to the cost of this practice.

5.
Spine (Phila Pa 1976) ; 49(10): 671-676, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38282440

RESUMEN

STUDY DESIGN: This was a retrospective study with prospective patient contact attempted to collect current data. OBJECTIVE: The purpose was to investigate the incidence and reasons for lumbar total disk replacement (TDR) removal or revision. SUMMARY OF BACKGROUND DATA: A concern regarding lumbar TDR was safety, particularly the need for device removal or revision. This may be particularly important considering removal/revision requires repeat anterior exposure with an increased risk of vascular injury. METHODS: Data were collected for a series of 2141 lumbar TDR patients, beginning with the first case experience in 2000. The mean follow-up was 78.6 months. For each case of device removal/revision, the reason, duration from index surgery, and procedure performed were recorded. RESULTS: Of 2141 patients, 27 (1.26%) underwent TDR removal or revision. Device removal was performed in 24 patients (1.12%), while three patients underwent revision (0.14%). Of the 24 removals, 12 were due to migration and/or loosening, three developed problems post-trauma, two developed lymphocytic reaction to device materials, two had ongoing pain, and there was one case of each: TDR was too large, vertebral body fracture (osteoporosis), lytic lesion, device subsidence and facet arthrosis, and infection seeded from a chest infection 146 months post-TDR. The three revisions were for Core repositioning (technique error), device repositioning after displacement, and core replacement due to wear/failure. With respect to timing, 37.0% of removals/revisions occurred within one-month postimplantation. Of note, 40.7% of removals/revisions occurred in the first 25 TDR cases performed by individual surgeons. There was one significant vascular complication occurring in a patient whose TDR was removed due to trauma. This was also the only patient among 258 with ≥15-year follow-up who underwent removal/revision. CONCLUSION: In this large consecutive series, 1.26% of TDRs were removed/revised. The low rate over a 20 year period supports the safety of these devices.


Asunto(s)
Remoción de Dispositivos , Vértebras Lumbares , Reoperación , Reeemplazo Total de Disco , Humanos , Reeemplazo Total de Disco/efectos adversos , Reeemplazo Total de Disco/instrumentación , Reeemplazo Total de Disco/métodos , Masculino , Vértebras Lumbares/cirugía , Femenino , Reoperación/estadística & datos numéricos , Persona de Mediana Edad , Adulto , Estudios Retrospectivos , Anciano , Estudios de Seguimiento , Resultado del Tratamiento
6.
J Neurosurg Spine ; 40(1): 84-91, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862719

RESUMEN

OBJECTIVE: The purpose of this study was to compare and contrast lumbar bone quality and osteoporosis/osteopenia screening results via dual-energy x-ray absorptiometry (DEXA), CT, and MRI. METHODS: A consecutive series of 426 candidates screened for lumbar disc replacement over a 5-year period beginning in 2018 was reviewed. Patients with a preoperative lumbar spine DEXA scan and a CT and/or MRI scan were included. The primary outcome measures included the bone mineral density (BMD) and osteoporosis or osteopenia classification from DEXA scans, Hounsfield units (HUs) for CT, and vertebral bone quality (VBQ) assessment for MRI. Patients were included if they had a DEXA scan within 1 year of an MRI or CT scan. DEXA BMD scores from composite or level-by-level reports were recorded. Asynchronous MRI and CT measurements were conducted using PACS. Interrater and intrarater reliability scores were generated for both CT and MRI measurements and ranged from 1.000 for MRI L1-4 scans to 0.683 for MRI VBQ. RESULTS: All 3 types of scans were statistically significantly correlated with one another; however, CT was more strongly correlated with the lumbar DEXA value (r = 0.439, p < 0.001). The correlation between MRI VBQ and DEXA was -0.103, (p < 0.045). The CT level-by-level measurements correlate with the corresponding level-by-level DEXA BMD values (correlation ranging from 0.531 to 0.289, p < 0.001 to p = 0.007). CT HU values were more strongly related to osteoporosis/osteopenia classification based on DEXA T-scores than were MRI VBQ values. Receiver operating characteristic analyses found that the area under the curve was 0.817 for CT and 0.539 for MRI. CONCLUSIONS: These results demonstrate that CT HUs more closely correlate to DEXA scores than MRI VBQ in this population of patients undergoing surgery for symptomatic disc degeneration. Thus, CT may be an alternative to DEXA for assessing VBQ in this population.


Asunto(s)
Enfermedades Óseas Metabólicas , Osteoporosis , Humanos , Absorciometría de Fotón/métodos , Reproducibilidad de los Resultados , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estudios Retrospectivos , Densidad Ósea , Osteoporosis/diagnóstico por imagen , Osteoporosis/cirugía
7.
Eur Spine J ; 32(9): 3176-3182, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37439864

RESUMEN

PURPOSE: The purpose of this study was to investigate the impact of various methods on the assessment of vertebral bone quality. METHODS: A consecutive series of 427 candidates for lumbar disc replacement with lumbar DEXA and MRI and/or CT scans were included. Two measurement techniques were used on CTs-a sagittal and axial. From axial images, the upper, mid, and lower portions of each vertebral body were measured. Four MRI vertebral bone quality (VBQ) calculations were generated using separate equations. RESULTS: All CT measures were highly correlated with each other, regardless of measurement or calculation method (range 0.925-0.995). Sagittal measurements were highly correlated with axial (r = 0.928, p < 0.001). CT values were correlated with DEXA (range 0.446-0.534). There was no benefit to measuring multiple axial images of each vertebral body vs. just midbody (r = 0.441 and 0.455, respectively). No MRI VBQ values were highly correlated with DEXA (r = - 0.103, p = 0.045). In receiver operating curve analysis, the area under the curve ranged from 0.539 to 0.558, indicating poor ability of VBQ to identify osteoporosis/osteopenia. CONCLUSION: CT produced values more closely related to DEXA, while MRI was less reliable for osteoporosis/osteopenia screening. On CT, there was no benefit to making multiple measurements for each vertebral body to calculate a composite. Measuring sagittal CT images produced values similar to axial and required less time. While assessing bone quality from existing images rather than getting an additional DEXA scan is appealing, the methods of measuring these images needs standardization to maximize their utility.


Asunto(s)
Enfermedades Óseas Metabólicas , Osteoporosis , Humanos , Densidad Ósea , Absorciometría de Fotón/métodos , Vértebras Lumbares/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos
8.
J Orthop Surg Res ; 18(1): 364, 2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37194059

RESUMEN

BACKGROUND: Anterior cervical corpectomy and fusion (ACCF) is an effective technique to address multi-level degenerative cervical myelopathy. However, as the number of surgical levels increases, the outcomes worsen with respect to complication rates, range of motion and length of surgery. This study aimed to determine the clinical outcome of ACCF procedures performed using a new distally curved and shielded drilling device. METHODS: A retrospective study was conducted on 43 ACCF procedures in which the device was used for osteophyte removal. Patient files were reviewed to assess the early clinical results and complications following ACCF. Clinical outcomes were evaluated using patient neck and arm pain scores and SF-36 questionnaires. Hospitalization characteristics were compared with historical controls. RESULTS: All procedures were uneventful and without major complications or neurological deterioration. Single-level ACCF procedures required an average of 71 min and followed by an average hospitalization of 3.3 days. Osteophyte removal, verified by intraoperative imaging, was satisfactory. Average neck pain score was improved by 0.9 points (p = 0.24). Average arm pain score was improved by 1.8 points (p = 0.06). SF-36 scores were improved in all domains. CONCLUSIONS: The new curved device enabled safe and efficient removal of osteophytes sparing adjacent vertebral removal in ACCF procedures, thus improving the clinical outcome.


Asunto(s)
Osteofito , Fusión Vertebral , Espondilosis , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Espondilosis/diagnóstico por imagen , Espondilosis/cirugía , Espondilosis/complicaciones , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Discectomía/efectos adversos , Discectomía/métodos , Dolor de Cuello/etiología , Dolor de Cuello/cirugía , Fusión Vertebral/métodos
10.
Eur Spine J ; 32(3): 797-802, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36520212

RESUMEN

PURPOSE: It is sometimes anticipated that patients with prior spine surgery will have a compromised outcome from future procedures. The purpose of this study was to compare TDR outcomes in patients with prior lumbar spine surgery to those with no previous surgery. METHODS: Post hoc analysis was performed on 5-year follow-up data collected prospectively in the multi-centre FDA-regulated trial for the activL® Artificial Disc which involved 376 patients treated for single-level symptomatic disc degeneration. Clinical outcome measures included the Oswestry Disability Index (ODI), visual analog scales (VAS) assessing back and leg pain, SF-36, adverse events, and re-operations. Radiographic outcomes included flexion/extension range of motion (ROM) and translation of the operated segment. Patients were divided into two groups: Prior Lumbar Surgery (PLS, n = 92) and No Prior Lumbar Surgery (NPLS, n = 284). RESULTS: Baseline demographics were similar in the two groups. ODI, VAS, and SF-36 Physical Component Scale scores improved significantly (p < 0.05) from baseline in both groups with improvements maintained through 5-year post-TDR with no significant differences between groups. There were no statistically significant differences in rates of serious device-related events, procedure-related events, or re-operations. While ROM was significantly less prior to TDR surgery in the PLS group, there was no significant difference in ROM at post-operative points. CONCLUSION: Prior lumbar spine surgery was not associated with compromised outcomes following TDR. These results are in line with reports from earlier studies with shorter follow-up, finding that non-destabilizing prior surgery is not a contra-indication for TDR provided that selection criteria are met. LEVEL OF EVIDENCE I: Diagnostic: individual cross-sectional studies with the consistently applied reference standard and blinding.


Asunto(s)
Degeneración del Disco Intervertebral , Reeemplazo Total de Disco , Humanos , Estudios Transversales , Estudios de Seguimiento , Estudios Prospectivos , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía
11.
Int J Spine Surg ; 17(1): 1-5, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35940637

RESUMEN

BACKGROUND: Anterior lumbar interbody fusion (ALIF) has been performed for many years. Often, posterior supplemental fixation has been used to provide additional stability to the operated segment. Interbody implants have evolved to incorporate unique designs, polyetheretherketone, integrated screws, and surface texture. With these changes, the need for supplemental posterior fixation has been debated. The purpose of this study was to evaluate the clinical outcome of stand-alone ALIF. METHODS: A surgery log was reviewed to identify the consecutive series of 58 patients undergoing ALIF using a STALIF stand-alone cage from March 2011 (first case) to December 2018 (minimum 24 months postoperative) with a mean follow-up of 30.6 months. All patients were treated for symptomatic degenerative conditions. Charts were reviewed to collect general patient information, operative data, and patient-reported outcomes, including the Oswestry Disability Index (ODI), visual analog scales (VAS) separately assessing back pain and leg pain, and re-operations. For patients who were not seen recently in clinic for follow-up, current outcome data were collected through mailings. RESULTS: The mean operative blood loss was 52.1 mL. There was a statistically significant improvement in mean ODI scores from 41.7 preoperatively to 21.0 at follow-up (P < 0.01). There was also significant improvement (P < 0.01) in VAS back pain (6.0-2.5) and leg pain (4.1-1.3). Subsequent surgery was performed on 9 patients. Reasons for re-operation were pseudoarthrosis (n = 3), progressive cage subsidence (n = 1), foraminal stenosis at the index level (n = 1), metal allergy reaction (n = 2), adjacent segment degeneration (n = 1), and ongoing pain (n = 1). There were no cases of device failure, vertebral body fracture, or screws backing out of the implant. DISCUSSION: Stand-alone ALIF was associated with statistically significant improvements in ODI scores, back pain, and leg pain. The re-operation rate for clear pseudoarthrosis or cage subsidence was 6.8%. These results support that stand-alone ALIF produces good outcomes in patients treated for symptomatic disc degeneration while avoiding the use of posterior fixation and its complication risk and cost. CLINICAL RELEVANCE: The results of this study support that stand-alone ALIF is a viable procedure for the treatment of symptomatic disc degeneration unresponsive in patients who have failed nonoperative care and who do not have specific indications for supplemental posterior instrumentation.

12.
Eur Spine J ; 31(10): 2607-2611, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35922636

RESUMEN

PURPOSE: The purpose of this study was to investigate reasons and their frequency for why spine surgeons subspecializing in total disc replacement (TDR) performed lumbar fusion rather than TDR. METHODS: The study was based on a consecutive series of 515 patients undergoing lumbar TDR or fusion during a 5-year period by three surgeons specializing in TDR. For each fusion patient, the reason for not performing TDR was recorded. RESULTS: TDR was performed in 65.4% (n = 337) of patients and the remaining 34.6% (n = 178) underwent anterior lumbar interbody fusion (ALIF ± posterior instrumentation). Of the 178 fusion patients, the most common reason for fusion was combined factors related to severe degenerative changes (n = 59, 11.5% of the study population). The second most common reason was > Grade 1 spondylolisthesis (n = 32, 6.2%), followed by insurance non-coverage (n = 24, 4.7%), and osteopenia/osteoporosis (n = 13, 2.5%). Fusion patients were significantly older than TDR patients (52.5 vs. 41.6 years; p < 0.01). There was no significant difference with respect to gender (41.2% female vs. 43.8% female, p > 0.05) or the percentage of patients with single-level surgery (61.2% vs. 56.7%, p > 0.05). CONCLUSION: The most common reason for not performing lumbar TDR was related to anatomic factors that may compromise stability of the operated segment and/or TDR functionality. The older age of fusion patients may be related to these factors. This study found that many patients are appropriate candidates for lumbar TDR. However, even among TDR subspecialists, fusion is preferred when there are factors that cannot be addressed with TDR and/or may compromise implant functionality.


Asunto(s)
Degeneración del Disco Intervertebral , Fusión Vertebral , Cirujanos , Reeemplazo Total de Disco , Femenino , Humanos , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Masculino , Fusión Vertebral/métodos , Reeemplazo Total de Disco/métodos , Resultado del Tratamiento
13.
J Neurosurg Spine ; : 1-11, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35364570

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of a PEEK-on-ceramic cervical total disc replacement (cTDR) device for the treatment of 2-level cervical disc disease with radiculopathy and/or myelopathy. METHODS: The study was a prospective, nonrandomized, historically controlled FDA investigational device exemption trial evaluating the Simplify Cervical Artificial Disc for use at 2 levels. The anterior cervical discectomy and fusion (ACDF) control group was derived from a propensity score-matched (using subclassification) cohort of patients who participated in an earlier prospective trial in which similar indications were used. The follow-up duration was 24 months. The primary outcome was a 4-point composite success classification. Other validated clinical and radiographic assessments were also evaluated. RESULTS: The investigational group (n = 182) was compared with patients who underwent ACDF (n = 170) in a historical control group using propensity score analysis. The overall composite success rate was statistically significantly greater in the cTDR group compared with the ACDF group (86.7% vs 77.1%; p < 0.05). The mean Neck Disability Index scores improved significantly in both groups, with cTDR significantly lower at some follow-up points. At the 24-month follow-up, a minimum 15-point improvement in Neck Disability Index scores was achieved in 92.9% of the cTDR group and 83.5% of the ACDF group (p > 0.05). In both groups, neck and arm pain scores improved significantly (p < 0.05) by 6 weeks and improvement was maintained throughout follow-up. Segmental range of motion was maintained at both treated segments in the cTDR group. MRI performed in the cTDR group at 24 months postoperatively found minimal changes in facet joint degeneration. The rate of subsequent surgical intervention was 2.2% in the cTDR group and 8.8% in the ACDF group. CONCLUSIONS: This study adds to the growing body of literature supporting cTDR for 2-level cervical disc disease with radiculopathy or myelopathy. cTDR showed a superior overall success rate compared to ACDF, while maintaining motion. These results support that the Simplify disc is a viable alternative to ACDF in appropriately selected patients with 2-level cervical spondylosis.

14.
Clin Spine Surg ; 35(4): 166-169, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35344516

RESUMEN

STUDY DESIGN: This study was a post hoc analysis of data collected from 2 Food and Drug Administration (FDA) Investigational Device Exemption (IDE) trials. OBJECTIVE: The purposes of this study were to: (1) measure disk space heights adjacent to the level to be treated with a total disk replacement (TDR); (2) analyze cervical disk space heights to be replaced with TDR; and (3) investigate the frequency of use of a smaller height TDR when available. SUMMARY OF BACKGROUND DATA: Cervical TDR produces outcomes noninferior or superior to anterior cervical discectomy and fusion. While the restoration of the height of a collapsed, degenerated disk is a surgical goal, there are potential problems with overdistracting the segment with an implant. METHODS: Disk heights were measured using radiographs from the 1-level Simplify Cervical Artificial Disk IDE trial, producing values for 259 levels adjacent to the treated level and 162 treated levels. The device is available in 4, 5, and 6 mm heights. The 4 mm height became available only after treatment was 13% complete in the single-level trial and was available for all of the 2-level trial. RESULTS: Measurements of 259 adjacent levels found that 55.2% of disk spaces had a height of <4 mm. Among operated levels, 82.7% were <4 mm. When a 4 mm TDR was available, it was used in 38.4% of operated levels in the 1-level trial and 54.3% of levels in the 2-level trial. CONCLUSIONS: Among nonoperated levels, 55.2% were of height <4 mm, suggesting that TDRs of greater heights may potentially overdistract the disk space. The 4 mm TDR was selected by surgeons in 49.4% of all implanted levels, suggesting a preference for smaller TDR height. Further investigation is warranted to determine if the lower height implants are related to clinical and/or radiographic outcomes. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Degeneración del Disco Intervertebral , Fusión Vertebral , Reeemplazo Total de Disco , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Discectomía , Estudios de Seguimiento , Humanos , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía , Estudios Prospectivos , Rango del Movimiento Articular , Resultado del Tratamiento
15.
Global Spine J ; 12(5): 812-819, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33089712

RESUMEN

STUDY DESIGN: Original research, cross-sectional study. OBJECTIVES: Evaluate patient satisfaction with spine care delivered via telemedicine. Identify patient- and visit-based factors associated with increased satisfaction and visit preference. METHODS: Telemedicine visits with a spine surgeon at 2 practices in the United States between March and May 2020 were eligible for inclusion in the study. Patients were sent an electronic survey recording overall satisfaction, technical or clinical issues encountered, and preference for a telemedicine versus an in-person visit. Factors associated with poor satisfaction and preference of telemedicine over an in-person visit were identified using multivariate logistic regression. RESULTS: A total of 772 responses were collected. Overall, 87.7% of patients were satisfied with their telemedicine visit and 45% indicated a preference for a telemedicine visit over an in-person visit if given the option. Patients with technical or clinical issues were significantly less likely to achieve 5 out of 5 satisfaction scores and were significantly more likely to prefer an in-person visit. Patients who live less than 5 miles from their surgeon's office and patients older than 60 years were also significantly more likely to prefer in-person visits. CONCLUSIONS: Spine telemedicine visits during the COVID-19 pandemic were associated with high patient satisfaction. Additionally, 45% of respondents indicated a preference for telemedicine versus an in-patient visit in the future. In light of these findings, telemedicine for spine care may be a preferable option for a subset of patients into the future.

16.
Neurosurg Clin N Am ; 32(4): 449-460, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34538471

RESUMEN

This article reviews the available literature for novel cervical total disc replacement devices, including ones which are available inside and outside of the United States. It includes biomechanical consideration as well as design characteristics and clinical data when available.


Asunto(s)
Degeneración del Disco Intervertebral , Disco Intervertebral , Fusión Vertebral , Reeemplazo Total de Disco , Vértebras Cervicales/cirugía , Humanos , Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Estados Unidos
17.
Int J Spine Surg ; 15(5): 978-987, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34551924

RESUMEN

BACKGROUND: Lumbar total disc replacement (TDR) has produced results similar or superior to fusion in treating symptomatic disc degeneration. Some patients have reported onset of leg pain early after surgery. Little information is available specifically on this problem. The purpose of this study was to investigate the incidence of early-onset postoperative leg pain following lumbar TDR and to describe strategies for its treatment. METHODS: The study was based on a post hoc analysis of prospectively collected adverse event data from 283 patients in the activL Food and Drug Administration investigational device exemption study. Early-onset leg pain was defined as occurring between 0 and 4 weeks postprocedure, and the baseline visual analog scale score in the affected leg(s) was <25 (of 100). The treatment types these patients received were analyzed. RESULTS: Among 283 patients, 26 (9.2%) had an early-onset leg pain event. The majority of these events resolved (20/26, 76.9%). Of those resolving, 55% (11/20) did so within 3 months. Most patients received at least 1 drug treatment for leg pain (92.3%). Of those receiving drug therapy, the most common type was neurogenic (61.5%), followed by narcotics (46.2%). Steroid use was prescribed in 30.8%. The majority of resolved cases were not on narcotics and resolved with neurogenic drugs. Three patients went on to have surgery, none of whom benefited from it. Age, body mass index, and baseline disability scores were predictive of time to resolution. CONCLUSION: Early-onset postoperative leg pain occurred in approximately 10% of lumbar TDR patients. The majority of events resolved, often within 3 months. Treatment with conservative care, including medication(s), was more effective in resolving symptoms rather than surgery. CLINICAL RELEVANCE: This study provides useful information for providers and patients on the incidence, treatment, and resolution of leg pain with onset after lumbar TDR and not related to direct neural compression identified by imaging. LEVEL OF EVIDENCE: 2.

18.
Int J Spine Surg ; 15(4): 633-644, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34281951

RESUMEN

BACKGROUND: Many early cervical total disc replacements (TDRs) produced motion through a ball-and-socket action, with metal endplates articulating with a plastic core. Polyetheretherketone (PEEK) is used increasingly for spinal implants due to its mechanical properties and lack of artifacts on imaging. A TDR was designed with titanium-coated PEEK endplates and a ceramic core. The purpose of this study was to compare this TDR with anterior cervical discectomy and fusion (ACDF) to treat single-level cervical disc degeneration. METHODS: This was a prospective, nonrandomized, historically controlled, multicenter US Food and Drug Administration (FDA) Investigational Device Exemption (IDE) trial. Patients received the PEEK-on-ceramic Simplify® Cervical Artificial Disc (n = 150). The historic control group included 117 propensity-matched ACDF patients from an earlier IDE trial. The primary outcome was a composite success classification at the 24-month follow-up. Outcome measures included the Neck Disability Index (NDI), neurological status, adverse events, subsequent surgery, a visual analog scale assessing neck and arm pain, and the Dysphagia Handicap Index. Radiographic assessment included flexion/extension range of motion and heterotopic ossification. Facet joints were assessed at 24 months using MRI. RESULTS: The success rate was significantly greater in the TDR group vs the ACDF group (93.0% vs 73.6%; P < .001). Mean NDI, neck pain, and arm pain scores improved significantly in both groups at all follow-up points. Mean NDI scores in the TDR group were significantly lower than ACDF scores at all follow-up points. There were no significant differences in the rates of serious adverse events. The range of motion of the TDR level had increased significantly by 3 months and remained so throughout follow-up. Facet joint assessment by MRI in the TDR group showed little change from preoperation. CONCLUSIONS: The TDR had an acceptable safety profile and a significantly greater composite success rate than ACDF. These results support that the PEEK-on-ceramic TDR is a viable alternative to ACDF for single-level symptomatic disc degeneration. CLINICAL RELEVANCE: This study found that the PEEK-on-ceramic TDR is a viable treatment for symptoms related to cervical disc degeneration and offers similar or superior outcomes compared with fusion. LEVEL OF EVIDENCE: 2.

19.
Spine J ; 21(7): 1110-1117, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33640583

RESUMEN

BACKGROUND CONTEXT: The reoperation rate following TDR (Total Disc replacement) has been established at short- and mid-term time points through the Food and Drug Administration Investigational Device Exemption (FDA IDE) trials. However, these trials include highly selected centers and surgeons with strict governance of indications. The utilization of TDR throughout the community needs further analysis. PURPOSE: To identify the risk factors for lumbar spine reoperation in patients undergoing lumbar total disc replacement (TDR) at short-, mid-, and long-term follow-up. STUDY DESIGN/SETTING: This study is a multi-center retrospective cohort study utilizing the New York Statewide Planning and Research Cooperative System database. PATIENT SAMPLE: We identified 1,368 patients who underwent an elective primary lumbar TDR in New York State between January 1, 2005 and September 30, 2013. OUTCOME MEASURES: The primary functional outcome of interest was lumbar reoperation, specifically the evaluation of independent risk factors for lumbar reoperation at a minimum of 2 years, with sub-analyses performed at 5 and ten years. METHODS: International Classification of Diseases, Ninth revision codes were utilized to identify patients undergoing a primary lumbar TDR. We excluded patients with primary/revision lumbar fusion procedures and revision disc replacement procedures. Hospital academic status was determined by the Accreditation Council for Graduate Medical Education. Unique encrypted patient identifiers allowed for longitudinal follow-up for reoperation. Logistic regression models compared reoperation and no-reoperation cohorts, and were performed on sub-analyses for significant univariate predictors of reoperation. RESULTS: Between January 2005 and September 2013, 1368 patients underwent a primary lumbar TDR. Reoperation occurred in 8.8% by 2 years, 15.8% by 5 years, and 19.5% by ten years. Diabetics were more likely to have reoperations (7.5% vs 3.8%, p=.013). Teaching hospitals experienced a decreased reoperation rate compared to nonteaching hospitals at 2-year (5.0% vs 10.5%, p=.002), 5-year (10.7% vs 17.9%, p=.002) and 10-year (11.7% vs 21.9%, p=.045) follow-up. Lumbar fusion was the most common reoperation (14.2%). CONCLUSION: We identified an 8.8% reoperation rate after inpatient lumbar TDR at 2-years, 15.8% at 5-years, and 19.5% at 10-years. When stratifying by teaching status, reoperation rates at teaching centers align with those reported in FDA IDE studies. Diabetes was the only patient factor influencing reoperation rate. There is a growing consensus that lumbar TDR is a durable and appropriate surgical option for lumbar degenerative disc disease. Proper indications are crucial to obtaining good outcomes with lumbar TDR.


Asunto(s)
Degeneración del Disco Intervertebral , Fusión Vertebral , Reeemplazo Total de Disco , Estudios de Seguimiento , Humanos , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Reeemplazo Total de Disco/efectos adversos , Resultado del Tratamiento
20.
Pharmacoecon Open ; 5(3): 519-531, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33462767

RESUMEN

BACKGROUND: Transforaminal lumbar interbody fusion (TLIF) represents a commonly performed spinal procedure that poses a significant financial burden on patients, hospitals and insurers. Reducing these costs, while maintaining efficacy, may be assisted by a new powered endplate preparation device, designed to shorten procedural time while offering positive impacts on other elements that contribute to the cost of care. OBJECTIVE: The aim of the study was to assess and compare the individual cost elements of TLIF procedures with and without the use of the device, to determine whether application of this technology translated into any material procedural savings. METHODS: The records of 208 single-level TLIF procedures in a single hospital were reviewed. Surgical time, length of hospital stay, blood loss, infection rate, and other parameters were compared for the cases where the device was used (device group; n = 143) and cases which used standard tools (control group; n = 65). The cost per unit of each element was derived from the literature, online resources, and the hospital's financial department. RESULTS: The analysis revealed a shorter surgery duration in the device group (23 min, after controlling for procedure year and patient characteristics; statistically significant at p < 0.001) and lower complication and readmission rates (p = 0.67 and p = 0.21, respectively) associated with the use of the device, leading to a statistically significant cost reduction of approximately 2060 US dollars (US$) (p < 0.01). CONCLUSION: The study suggests that use of the device may lead to a cost reduction and shorter procedure without deteriorating the clinical outcome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...