Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Photonics ; 11(4): 1447-1455, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38645998

RESUMEN

We present measurements of the coherence times of excited states of hydrogen-like arsenic impurities in germanium (Ge:As) using a table-top two-dimensional time-domain spectroscopy (2D-TDS) system. We show that this laboratory system is capable of resolving the coherence lifetimes of atomic-like excited levels of impurity centers in semiconductors, such as those used in solid-state quantum information technologies, on a subpicosecond time scale. By fitting the coherent nonlinear response of the system with the known intracenter transition frequencies, we are able to monitor coherent population transfer and decay of the transitions from the 2p0 and 2p± states for different low excitation pulse fields. Furthermore, by examining the off-diagonal resonances in the 2D frequency-domain map, we are able to identify coherences between excited electronic states that are not visible via conventional single-frequency pump-probe or Hahn-echo measurements.

2.
Nat Commun ; 14(1): 6812, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37935682

RESUMEN

Atomic oxygen is a key species in the mesosphere and thermosphere of Venus. It peaks in the transition region between the two dominant atmospheric circulation patterns, the retrograde super-rotating zonal flow below 70 km and the subsolar to antisolar flow above 120 km altitude. However, past and current detection methods are indirect and based on measurements of other molecules in combination with photochemical models. Here, we show direct detection of atomic oxygen on the dayside as well as on the nightside of Venus by measuring its ground-state transition at 4.74 THz (63.2 µm). The atomic oxygen is concentrated at altitudes around 100 km with a maximum column density on the dayside where it is generated by photolysis of carbon dioxide and carbon monoxide. This method enables detailed investigations of the Venusian atmosphere in the region between the two atmospheric circulation patterns in support of future space missions to Venus.

3.
Sensors (Basel) ; 22(23)2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36502218

RESUMEN

The project Lunar Volatiles Mobile Instrumentation-Extended (LUVMI-X) developed an initial system design as well as payload and mobility breadboards for a small, lightweight rover dedicated for in situ exploration of the lunar south pole. One of the proposed payloads is the Volatiles Identification by Laser Analysis instrument (VOILA), which uses laser-induced breakdown spectroscopy (LIBS) to analyze the elemental composition of the lunar surface with an emphasis on sampling regolith and the detection of hydrogen for the inference of the presence of water. It is designed to analyze targets in front of the rover at variable focus between 300 mm and 500 mm. The spectrometer covers the wavelength range from 350 nm to 790 nm, which includes the hydrogen line at 656.3 nm as well as spectral lines of most major rock-forming elements. We report here the scientific input that fed into the concept and design of the VOILA instrument configuration for the LUVMI-X rover. Moreover, we present the measurements performed with the breadboard laboratory setup for VOILA at DLR Berlin that focused on verifying the performance of the designed LIBS instrument in particular for the detection and quantification of hydrogen and other major rock forming elements in the context of in situ lunar surface analysis.


Asunto(s)
Rayos Láser , Luna , Análisis Espectral/métodos , Agua , Hidrógeno
4.
J Breath Res ; 16(4)2022 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-35688126

RESUMEN

The analysis of human breath is a very active area of research, driven by the vision of a fast, easy, and non-invasive tool for medical diagnoses at the point of care. Millimeter-wave gas spectroscopy (MMWGS) is a novel, well-suited technique for this application as it provides high sensitivity, specificity and selectivity. Most of all, it offers the perspective of compact low-cost systems to be used in doctors' offices or hospitals. In this work, we demonstrate the analysis of breath samples acquired in a medical environment using MMWGS and evaluate validity, reliability, as well as limitations and perspectives of the method. To this end, we investigated 28 duplicate samples from chronic obstructive lung disease patients and compared the results to gas chromatography-mass spectrometry (GC-MS). The quantification of the data was conducted using a calibration-free fit model, which describes the data precisely and delivers absolute quantities. For ethanol, acetone, and acetonitrile, the results agree well with the GC-MS measurements and are as reliable as GC-MS. The duplicate samples deviate from the mean values by only 6% to 18%. Detection limits of MMWGS depend strongly on the molecular species. For example, acetonitrile can be traced down to 1.8 × 10-12mol by the MMWGS system, which is comparable to the GC-MS system. We observed correlations of abundances between formaldehyde and acetaldehyde as well as between acetonitrile and acetaldehyde, which demonstrates the potential of MMWGS for breath research.


Asunto(s)
Pruebas Respiratorias , Enfermedad Pulmonar Obstructiva Crónica , Acetaldehído , Acetonitrilos , Pruebas Respiratorias/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Gases , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Reproducibilidad de los Resultados , Análisis Espectral
5.
Opt Express ; 28(16): 23114-23121, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-32752312

RESUMEN

We present an optically pumped terahertz gas laser, which is based on a mid-infrared quantum-cascade laser as a pump source, a transversely pumped standing wave resonator, and 15NH3 as a gain medium. We observe several laser lines around 4.5 THz, corresponding to rotational transitions in the ν2 band of ammonia. So far, these are the highest frequencies obtained from a QCL-pumped THz gas laser. The involved molecular transitions are unambiguously identified by high-resolution spectroscopy.

6.
Sensors (Basel) ; 19(12)2019 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-31212999

RESUMEN

Breath gas analysis is a promising tool for medical research and diagnosis. A particularly powerful technological approach is millimeter-wave/terahertz (mmW/THz) spectroscopy, because it is a very sensitive and highly selective technique. In addition, it offers the potential for compact and affordable sensing systems for wide use. In this work, we demonstrate the capability of a mmW/THz spectrometer for breath analysis. Samples from three volunteers and a sample from ambient air were analyzed with respect to 31 different molecular species. High-resolution absorption spectra were measured by scanning two absorption lines from each species. Out of the 31, a total of 21 species were detected. The results demonstrate the potential of mmW/THz spectroscopy for breath analysis.


Asunto(s)
Pruebas Respiratorias/métodos , Gases/análisis , Espectroscopía de Terahertz/métodos , Fenómenos Electromagnéticos , Humanos , Refractometría/métodos
7.
Opt Lett ; 44(5): 1210-1213, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30821750

RESUMEN

The development of diffractive lenses for the upper terahertz (THz) frequency range above 1 THz was successfully demonstrated by employing a direct laser ablation (DLA) technology. Two types of samples such as the Soret zone plate lens and the multi-level phase-correcting Fresnel lens were fabricated of a metal foil and crystalline silicon, respectively. The focusing performance along the optical axis of a 4.745 THz quantum cascade laser beam with respect to the positioning angle of the sample was studied by using a real-time microbolometric camera. A binary-phase profile sample demonstrated the values of the focusing gain and focused beam size up to 25 dB and 0.15 mm (2.4λ), respectively. The increase of the phase quantization level to eight led to higher (up to 29 dB) focusing gain values without a measurable increase of optical losses. All the samples were tolerant to misalignment as large as 10 deg of oblique incidence with a focusing power drop no larger than 10%. The results pave the way for new applications of industry-ready DLA technology in the entire THz range.

8.
Astrobiology ; 19(2): 145-157, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30742496

RESUMEN

BIOMEX (BIOlogy and Mars EXperiment) is an ESA/Roscosmos space exposure experiment housed within the exposure facility EXPOSE-R2 outside the Zvezda module on the International Space Station (ISS). The design of the multiuser facility supports-among others-the BIOMEX investigations into the stability and level of degradation of space-exposed biosignatures such as pigments, secondary metabolites, and cell surfaces in contact with a terrestrial and Mars analog mineral environment. In parallel, analysis on the viability of the investigated organisms has provided relevant data for evaluation of the habitability of Mars, for the limits of life, and for the likelihood of an interplanetary transfer of life (theory of lithopanspermia). In this project, lichens, archaea, bacteria, cyanobacteria, snow/permafrost algae, meristematic black fungi, and bryophytes from alpine and polar habitats were embedded, grown, and cultured on a mixture of martian and lunar regolith analogs or other terrestrial minerals. The organisms and regolith analogs and terrestrial mineral mixtures were then exposed to space and to simulated Mars-like conditions by way of the EXPOSE-R2 facility. In this special issue, we present the first set of data obtained in reference to our investigation into the habitability of Mars and limits of life. This project was initiated and implemented by the BIOMEX group, an international and interdisciplinary consortium of 30 institutes in 12 countries on 3 continents. Preflight tests for sample selection, results from ground-based simulation experiments, and the space experiments themselves are presented and include a complete overview of the scientific processes required for this space experiment and postflight analysis. The presented BIOMEX concept could be scaled up to future exposure experiments on the Moon and will serve as a pretest in low Earth orbit.


Asunto(s)
Cianobacterias/fisiología , Exobiología , Líquenes/fisiología , Marte , Biopelículas , Cianobacterias/efectos de la radiación , Deinococcus/fisiología , Deinococcus/efectos de la radiación , Medio Ambiente Extraterrestre , Líquenes/efectos de la radiación , Marchantia/fisiología , Marchantia/efectos de la radiación , Methanosarcina/fisiología , Methanosarcina/efectos de la radiación , Minerales , Rayos Ultravioleta
9.
Sci Rep ; 8(1): 4886, 2018 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-29559708

RESUMEN

Terahertz (THz) radiation meaning electromagnetic radiation in the range from 0.1 (3) to 10 (30) has the unique advantage of easily penetrating many obstructions while being non-hazardous to organic tissue since it is non-ionizing. A shortcoming of this domain is the limited availability of high-sensitivity detector arrays respective THz cameras with >1k pixels. To overcome the imaging limitations of the THz domain, compressive imaging in combination with an optically controllable THz spatial light modulator is a promising approach especially when used in a single-pixel imaging modality. The imaging fidelity, performance and speed of this approach depend crucially on the imaging patterns also called masks and their properties used in the imaging process. Therefore, in this paper, it is investigated how the image quality after reconstruction is specifically influenced by the different mask types and their properties in a compressive imaging modality. The evaluation uses an liquid-crystal display based projector as spatial light modulator to derive specific guidelines for the use of binary and true greyscale masks in THz single-pixel imaging setups respective THz single-pixel cameras when used in far-field applications e.g. stand-off security imaging.

10.
Opt Express ; 25(24): 30203-30213, 2017 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-29221052

RESUMEN

We report on real-time gas sensing with a terahertz quantum-cascade laser (QCL). The method is solely based on the modulation of the external cavity length, exploiting the intermediate optical feedback regime. While the QCL is operated in continuous-wave mode, optical feedback results in a change of the QCL frequency as well as its terminal voltage. The first effect is exploited to tune the lasing frequency across a molecular absorption line. The second effect is used for the detection of the self-mixing signal. This allows for fast measurement times on the order of 10 ms per spectrum and for real-time measurements of gas concentrations with a rate of 100 Hz. This technique is demonstrated with a mixture of D2O and CH3OD in an absorption cell.

11.
Opt Express ; 24(13): 13839-49, 2016 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-27410547

RESUMEN

We report on a high-spectral-resolution terahertz imaging system operating with a multi-mode quantum-cascade laser (QCL), a fast scanning mirror, and a sensitive Ge:Ga detector. By tuning the frequency of the QCL, several spectra can be recorded in 1.5 s during the scan through a gas cell filled with methanol (CH3OH). These experiments yield information about the local absorption and the linewidth. Measurements with a faster frame rate of up to 3 Hz allow for the dynamic observation of CH3OH gas leaking from a terahertz-transparent tube into the evacuated cell. In addition to the relative absorption, the local pressure is mapped by exploiting the effect of pressure broadening.

12.
J Chem Phys ; 131(3): 034311, 2009 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-19624201

RESUMEN

Transitions between the spin-rotational levels of the (14)NH(+) radical in the v = 0 levels of its X (2)Pi and a (4)Sigma(-) states have been studied by the technique of laser magnetic resonance at far-infrared wavelengths. The data have been combined with a previous zero-field measurement of the J = 1 1/2 - 1/2 transition frequencies at 1.01 THz to determine a much improved set of molecular parameters for NH(+) in the X (2)Pi state; the major parameters for the a (4)Sigma(-) state have also been determined. A full determination of the hyperfine parameters for both (14)N and (1)H nuclei has been achieved for the first time. Accurate predictions of the transition frequencies between the low-lying levels of the radical in the absence of a magnetic field have also been made, including lambda-doubling frequencies for use by radio astronomers.

13.
Opt Express ; 13(15): 5890-6, 2005 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-19498595

RESUMEN

Terahertz quantum cascade lasers have been investigated with respect to their performance as a local oscillator in a heterodyne receiver. The beam profile has been measured and transformed in to a close to Gaussian profile resulting in a good matching between the field patterns of the quantum cascade laser and the antenna of a superconducting hot electron bolometric mixer. Noise temperature measurements with the hot electron bolometer and a 2.5 THz quantum cascade laser yielded the same result as with a gas laser as local oscillator.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...