Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 26(Pt 2): 585-594, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30855271

RESUMEN

An experimental platform using X-ray free-electron laser (XFEL) pulses with high-intensity optical laser pulses is open for early users' experiments at the SACLA XFEL facility after completion of the commissioning. The combination of the hard XFEL and the high-intensity laser provides capabilities to open new frontiers of laser-based high-energy-density science. During the commissioning phase, characterization of the XFEL and the laser at the platform has been carried out for the combinative utilization as well as the development of instruments and basic diagnostics for user experiments. An overview of the commissioning and the current capabilities of the experimental platform is presented.

2.
Sci Adv ; 3(6): e1602705, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28630909

RESUMEN

The understanding of fracture phenomena of a material at extremely high strain rates is a key issue for a wide variety of scientific research ranging from applied science and technological developments to fundamental science such as laser-matter interaction and geology. Despite its interest, its study relies on a fine multiscale description, in between the atomic scale and macroscopic processes, so far only achievable by large-scale atomic simulations. Direct ultrafast real-time monitoring of dynamic fracture (spallation) at the atomic lattice scale with picosecond time resolution was beyond the reach of experimental techniques. We show that the coupling between a high-power optical laser pump pulse and a femtosecond x-ray probe pulse generated by an x-ray free electron laser allows detection of the lattice dynamics in a tantalum foil at an ultrahigh strain rate of [Formula: see text] ~2 × 108 to 3.5 × 108 s-1. A maximal density drop of 8 to 10%, associated with the onset of spallation at a spall strength of ~17 GPa, was directly measured using x-ray diffraction. The experimental results of density evolution agree well with large-scale atomistic simulations of shock wave propagation and fracture of the sample. Our experimental technique opens a new pathway to the investigation of ultrahigh strain-rate phenomena in materials at the atomic scale, including high-speed crack dynamics and stress-induced solid-solid phase transitions.

3.
Opt Lett ; 35(11): 1783-5, 2010 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20517415

RESUMEN

Segmented (tiled) grating arrays are being intensively investigated for petawatt-scale pulse compression due to the expense and technical challenges of fabricating monolithic diffraction gratings with apertures of over 1m. However, the considerable freedom of motion among grating segments complicates compression and laser focusing. We constructed a real compressor system using a segmented grating for an 18cm aperture laser beam of the Gekko MII 100TW laser system at Osaka University. To produce clean pulse shapes and single focal spots tolerant of misalignment and groove density difference of grating tiles, we applied a new compressor scheme with image rotation in which each beam segment samples each grating segment but from opposite sides. In high-energy shots of up to 50J, we demonstrated nearly Fourier-transform-limited pulse compression (0.5ps) with an almost diffraction-limited spot size (20microm).

4.
Phys Rev Lett ; 104(5): 055001, 2010 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-20366770

RESUMEN

We present direct measurements of the absolute energy distribution of relativistic electrons generated in intense, femtosecond laser interaction with a solid. Cherenkov emission radiated by these electrons in a novel prism target is spectrally dispersed to obtain yield and energy distribution of electrons simultaneously. A crucial advance is the observation of high density electron current as predicted by particle simulations and its transport as it happens inside the target. In addition, the strong sheath potential present at the rear side of the target is inferred from a comparison of the electron spectra derived from Cherenkov light observation with that from a magnet spectrometer.

5.
Rev Sci Instrum ; 79(10): 10E910, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044565

RESUMEN

Since an imaging plate (IP) is sensitive to electron, ion, and x rays, it can be used as a detector for laser plasma experiment using ultraintense laser. Moreover, an IP has the advantageous features such as high sensitivity, wide dynamic range, and high spatial resolution. Even though IP itself has a considerable wide dynamic range up to 10(5), the IP data have appeared often saturated at an IP reading device. We propose a reading technique by inserting optical density filters so that an apparently saturated IP data can be saved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...