Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Respir Res ; 25(1): 268, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38978068

RESUMEN

BACKGROUND: Lung ultrasound (LUS) in an emerging technique used in the intensive care unit (ICU). The derivative LUS aeration score has been shown to have associations with mortality in invasively ventilated patients. This study assessed the predictive value of baseline and early changes in LUS aeration scores in critically ill invasively ventilated patients with and without ARDS (Acute Respiratory Distress Syndrome) on 30- and 90-day mortality. METHODS: This is a post hoc analysis of a multicenter prospective observational cohort study, which included patients admitted to the ICU with an expected duration of ventilation for at least 24 h. We restricted participation to patients who underwent a 12-region LUS exam at baseline and had the primary endpoint (30-day mortality) available. Logistic regression was used to analyze the primary and secondary endpoints. The analysis was performed for the complete patient cohort and for predefined subgroups (ARDS and no ARDS). RESULTS: A total of 442 patients were included, of whom 245 had a second LUS exam. The baseline LUS aeration score was not associated with mortality (1.02 (95% CI: 0.99 - 1.06), p = 0.143). This finding was not different in patients with and in patients without ARDS. Early deterioration of the LUS score was associated with mortality (2.09 (95% CI: 1.01 - 4.3), p = 0.046) in patients without ARDS, but not in patients with ARDS or in the complete patient cohort. CONCLUSION: In this cohort of critically ill invasively ventilated patients, the baseline LUS aeration score was not associated with 30- and 90-day mortality. An early change in the LUS aeration score was associated with mortality, but only in patients without ARDS. TRIAL REGISTRATION: ClinicalTrials.gov, ID NCT04482621.


Asunto(s)
Pulmón , Respiración Artificial , Síndrome de Dificultad Respiratoria , Ultrasonografía , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Ultrasonografía/métodos , Síndrome de Dificultad Respiratoria/mortalidad , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Estudios de Cohortes , Enfermedad Crítica/mortalidad , Factores de Tiempo , Unidades de Cuidados Intensivos
2.
Crit Care ; 28(1): 96, 2024 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-38521944

RESUMEN

BACKGROUND: Acute respiratory distress syndrome (ARDS) poses challenges in early identification. Exhaled breath contains metabolites reflective of pulmonary inflammation. AIM: To evaluate the diagnostic accuracy of breath metabolites for ARDS in invasively ventilated intensive care unit (ICU) patients. METHODS: This two-center observational study included critically ill patients receiving invasive ventilation. Gas chromatography and mass spectrometry (GC-MS) was used to quantify the exhaled metabolites. The Berlin definition of ARDS was assessed by three experts to categorize all patients into "certain ARDS", "certain no ARDS" and "uncertain ARDS" groups. The patients with "certain" labels from one hospital formed the derivation cohort used to train a classifier built based on the five most significant breath metabolites. The diagnostic accuracy of the classifier was assessed in all patients from the second hospital and combined with the lung injury prediction score (LIPS). RESULTS: A total of 499 patients were included in this study. Three hundred fifty-seven patients were included in the derivation cohort (60 with certain ARDS; 17%), and 142 patients in the validation cohort (47 with certain ARDS; 33%). The metabolites 1-methylpyrrole, 1,3,5-trifluorobenzene, methoxyacetic acid, 2-methylfuran and 2-methyl-1-propanol were included in the classifier. The classifier had an area under the receiver operating characteristics curve (AUROCC) of 0.71 (CI 0.63-0.78) in the derivation cohort and 0.63 (CI 0.52-0.74) in the validation cohort. Combining the breath test with the LIPS does not significantly enhance the diagnostic performance. CONCLUSION: An exhaled breath metabolomics-based classifier has moderate diagnostic accuracy for ARDS but was not sufficiently accurate for clinical use, even after combination with a clinical prediction score.


Asunto(s)
Lesión Pulmonar , Neumonía , Síndrome de Dificultad Respiratoria , Humanos , Cuidados Críticos , Pulmón , Síndrome de Dificultad Respiratoria/diagnóstico
3.
Intensive Care Med Exp ; 12(1): 14, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345723

RESUMEN

BACKGROUND: Exhaled volatile organic compounds (VOCs), particularly hydrocarbons from oxidative stress-induced lipid peroxidation, are associated with hyperoxia exposure. However, important heterogeneity amongst identified VOCs and concerns about their precise pathophysiological origins warrant translational studies assessing their validity as a marker of hyperoxia-induced oxidative stress. Therefore, this study sought to examine changes in VOCs previously associated with the oxidative stress response in hyperoxia-exposed lung epithelial cells. METHODS: A549 alveolar epithelial cells were exposed to hyperoxia for 24 h, or to room air as normoxia controls, or hydrogen peroxide as oxidative-stress positive controls. VOCs were sampled from the headspace, analysed by gas chromatography coupled with mass spectrometry and compared by targeted and untargeted analyses. A secondary analysis of breath samples from a large cohort of critically ill adult patients assessed the association of identified VOCs with clinical oxygen exposure. RESULTS: Following cellular hyperoxia exposure, none of the targeted VOCs, previously proposed as breath markers of oxidative stress, were increased, and decane was significantly decreased. Untargeted analysis did not reveal novel identifiable hyperoxia-associated VOCs. Within the clinical cohort, three previously proposed breath markers of oxidative stress, hexane, octane, and decane had no real diagnostic value in discriminating patients exposed to hyperoxia. CONCLUSIONS: Hyperoxia exposure of alveolar epithelial cells did not result in an increase in identifiable VOCs, whilst VOCs previously linked to oxidative stress were not associated with oxygen exposure in a cohort of critically ill patients. These findings suggest that the pathophysiological origin of previously proposed breath markers of oxidative stress is more complex than just oxidative stress from hyperoxia at the lung epithelial cellular level.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...