Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Diabetes Care ; 47(6): 956-963, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412005

RESUMEN

OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.


Asunto(s)
Glucemia , Enfermedad Crítica , Humanos , Masculino , Glucemia/análisis , Persona de Mediana Edad , Femenino , Anciano , Abdomen/cirugía , Trasplante de Órganos , Estudios de Factibilidad , Adulto , Monitoreo Fisiológico/métodos , Monitoreo Continuo de Glucosa
3.
Transplant Proc ; 54(3): 806-810, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35227510

RESUMEN

BACKGROUND: Islet transplantation represents an established therapeutic option for people with type 1 diabetes who have hypoglycemia unawareness syndrome and frequent problematic hypoglycemic episodes when other methods comprising diabetes education and use of technological support fail. Because the current standard method of islet infusion into the liver has some limitations, novel approaches are under investigation. METHODS: We report our first results with 2 cases of islet transplantation into an omental pouch using a biocompatible plasma-fibrin gel. The recipients received 12,350 and 5,350 islet equivalents per kilogram that were mixed with autologous plasma, seeded during a laparoscopic procedure on the omentum, overlaid with human thrombin solution, and fixed by flapping the omentum over. RESULTS: During a 9-month follow-up, neither patient experienced any moderate or severe hypoglycemia. Their glucose control significantly improved, insulin dose decreased by approximately 50%, and C-peptide at 1 year was 0.22 and 0.14 pmol/mL, respectively. The postoperative course was uneventful, but C-peptide production in the first patient progressively declined at 1 year and hypoglycemic episodes recurred. CONCLUSIONS: Though the results for these first 2 cases are not fully satisfactory, we have demonstrated the feasibility, safety, and ability of this novel method to restore insulin production. Further refinements to improve immediate islet survival seem necessary.


Asunto(s)
Investigación Biomédica , Diabetes Mellitus Tipo 1 , Hipoglucemia , Trasplante de Islotes Pancreáticos , Islotes Pancreáticos , Glucemia , Péptido C , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/cirugía , Humanos , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Trasplante de Islotes Pancreáticos/efectos adversos , Trasplante de Islotes Pancreáticos/métodos , Epiplón/cirugía , Trombina/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA