Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 449
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39189600

RESUMEN

AIMS: Transcatheter tricuspid valve interventions (TTVI) are increasingly used to treat patients with significant tricuspid regurgitation (TR). The evolution of concurrent mitral regurgitation (MR) severity after TTVI is currently unknown and may be pivotal for clinical decision-making. The aim of this study was to assess the evolution of MR after TTVI and to identify predictors of MR worsening and improvement. METHODS AND RESULTS: This analysis is a substudy of the Trivalve Registry, an international registry designed to collect data on TTVI. This substudy included all patients with echocardiographic data on MR evolution and excluded those with a concomitant tricuspid and mitral transcatheter valve intervention or with a history of mitral valve intervention. The co-primary outcomes were MR improvement and worsening at two timepoints: pre-discharge and 2-month follow-up. This analysis included 359 patients with severe TR, mostly(80%) treated with tricuspid transcatheter edge-to-edge repair(T-TEER). MR improvement was found in 106(29.5%) and 99(34%) patients, while MR worsening in 34(9.5%) and 33(11%) patients at pre-discharge and 2-month follow-up, respectively. Annuloplasty and heterotopic replacement were associated with MR worsening. Independent predictors of MR improvement were: atrial fibrillation, T-TEER, acute procedural success, TR reduction, LVEDD>60 mm and beta-blocker therapy. Patients with moderate-to-severe/severe MR following TTVI showed significantly higher death rates. CONCLUSION: MR degree variation is common after TTVI, with most cases showing improvement. Clinical and procedural characteristics may predict the MR evolution, in particular procedural success and T-TEER play key roles in MR outcomes. TTVI may be beneficial even in the presence of functional MR.

2.
Eur Heart J Case Rep ; 8(8): ytae261, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39113778

RESUMEN

Background: Limited data exist on strain changes after transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation (AR). Case summary: Three patients with AR undergoing TAVI showed an initial reduction in global longitudinal strain (GLS), followed by sustained GLS improvement within the first year. Discussion: Findings align with those of surgically treated patients with AR. There is a possible superiority of GLS to left ventricular end-diastolic diameter ratio in assessing patients with severe volume overload.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39177555

RESUMEN

BACKGROUND: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV). OBJECTIVES: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes. METHODS: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality. RESULTS: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF). CONCLUSIONS: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.

4.
J Am Coll Cardiol ; 84(9): 832-847, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39168570

RESUMEN

Pathologic left ventricular remodeling and valvular heart disease may contribute to the clinical presentation and outcomes of patients presenting with heart failure, and limit the effectiveness of guideline-directed medical therapy. Although surgical interventions including surgical ventricular restoration techniques and valve repair or replacement are effective therapies, there is growing evidence that transcatheter interventions may be options for patients with persistent symptoms of heart failure despite optimal medical therapy, where surgical options may be limited. This scientific statement will review the current available and investigational percutaneous strategies for the management of structural contributors to heart failure: dilated left ventricular cardiomyopathies and valvular heart disease.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/terapia , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiomiopatía Dilatada/terapia , Cardiomiopatía Dilatada/fisiopatología
6.
Artículo en Inglés | MEDLINE | ID: mdl-39066744

RESUMEN

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

7.
J Am Coll Cardiol ; 84(2): 195-212, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38960514

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is associated with high morbidity and mortality. Important risk factors for the development of HFpEF are similar to risk factors for the progression of tricuspid regurgitation (TR), and both conditions frequently coexist and thus is a distinct phenotype or a marker for advanced HF. Many patients with severe, symptomatic atrial secondary TR have been enrolled in current transcatheter device trials, and may represent patients at an advanced stage of HFpEF. Management of HFpEF thus may affect the pathophysiology of TR, and the physiologic changes that occur following transcatheter treatment of TR, may also impact symptoms and outcomes in patients with HFpEF. This review discusses these issues and suggests possible management strategies for these patients.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología
8.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

9.
Circ Cardiovasc Interv ; 17(8): e013782, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39034924

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Falla de Prótesis , Recuperación de la Función , Humanos , Femenino , Masculino , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Anciano , Estudios Prospectivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Factores de Riesgo , Persona de Mediana Edad , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Medición de Riesgo , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Estados Unidos , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Hemodinámica , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad
10.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

11.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38884853

RESUMEN

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentación , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
12.
Am J Cardiol ; 225: 171-177, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38897265

RESUMEN

Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). The TRISCEND II pivotal trial studies the transcatheter EVOQUE (Edwards Lifesciences, Irvine, California) tricuspid valve replacement system using a United States Food and Drug Administration Breakthrough Device Designation-a program intended to provide timely access to medical devices by speeding up development, assessment, and review. The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness end points for the first 150 patients in the initial phase and a 1-year safety and effectiveness end point for the full cohort of 400 patients in the second phase. The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. In conclusion, the design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Válvula Tricúspide/cirugía , Estudios Prospectivos , Prótesis Valvulares Cardíacas , Resultado del Tratamiento
14.
Ann Cardiothorac Surg ; 13(3): 211-223, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38841078

RESUMEN

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthetic valve is too small in relation to the patient's body size. The effect of PPM on outcomes and valve durability have gained credibility, making this an important possibly preventable risk factor. Transcatheter aortic valve replacement (TAVR) generally has a lower incidence of PPM than surgical aortic valve replacement (SAVR). Current surgical literature and randomized trials show an association between severe PPM and mortality in patients with SAVR but there is less evidence for an association with TAVR. Differences in the incidence of PPM may be related to the methods and cutoffs for measuring mismatch. This review will discuss the current state of field and propose standardization of measurement methods which may more accurately risk stratify patients.

15.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
17.
Circulation ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38881496

RESUMEN

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

18.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938839

RESUMEN

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

20.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38795109

RESUMEN

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía de Estrés , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Curva ROC , Función Ventricular Izquierda , Área Bajo la Curva , Volumen Sistólico , Hemodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...