Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BJR Case Rep ; 9(6): 20230016, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37928712

RESUMEN

Femoral pseudoaneurysms are typically associated with femoral arterial catheterisation. Treating iatrogenic morbidity requires curing the disease, without causing any additional complications. Occlusion of the aneurysmal neck is ideal to seal post-catheterised pseudoaneurysms along with maintaining the femoral arterial flow. However, few reports have suggested neck embolisation for post-catheterised pseudoaneurysms. We describe five cases of iatrogenic femoral pseudoaneurysms in patients successfully treated with embolisation through the aneurysmal neck. This technique may be an alternative therapeutic option in managing femoral pseudoaneurysms.

2.
CVIR Endovasc ; 3(1): 24, 2020 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-32363471

RESUMEN

BACKGROUND: The penumbra occlusion device (POD) is a recently developed metallic coil with a unique anchor segment. The purpose of this study was to investigate the anchoring function of the POD for embolization of medium-sized vessels in detail. MATERIALS AND METHODS: We reviewed a series of cases of proximal embolization of medium-sized vessels in which the POD was used. Endovascular outcomes and complications were assessed. The distance between the distal end of the first-indwelled POD and the microcatheter tip was defined as the "landing distance," and this was also evaluated via fluoroscopic analysis. RESULTS: POD deployment was successful in 17 of 18 patients. The median landing distance was 9.6 mm, and no distal POD migration was observed after the formation of anchor loops. CONCLUSIONS: The specific anchoring function of the POD enables effective proximal occlusion of medium-sized vessels.

3.
PLoS One ; 14(12): e0226521, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31846490

RESUMEN

The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients.


Asunto(s)
Abdomen/diagnóstico por imagen , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Sobrepeso/diagnóstico por imagen , Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Control de Calidad , Estudios Retrospectivos
4.
Gan To Kagaku Ryoho ; 46(10): 1599-1601, 2019 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-31631148

RESUMEN

A man in his 40s presented with fever and nasal congestion. NK-T cell lymphoma was pathologically diagnosed. A central venous(CV)port was implanted via a right subclavian approach. Four months later, redness and swelling were observed around the implanted CV port. Initially, an infection of the CV port was suspected, and the CV port was removed. Regardless of the removal of the port, the wound healing was refractory, and an ulcer formed. Surgical biopsy from the ulcer showed skin infiltration of NK-T cell lymphoma. In cases ofref ractory wound healing around an implanted CV port in patients with lymphoma, lymphoma recurrence and port infection should be considered.


Asunto(s)
Cateterismo Venoso Central , Linfoma , Biopsia , Bases de Datos Genéticas , Humanos , Masculino , Prótesis e Implantes , Recurrencia
5.
Acta Crystallogr Sect E Struct Rep Online ; 69(Pt 4): m179-80, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23633985

RESUMEN

The title salt, [CoBr(C11H27N5)]Br2·2H2O, contains a complex cation with mirror symmetry and two Br(-) counter-anions that are likewise located on the mirror plane. The central Co(III) atom of the complex cation has one Br(-) ion in an axial position, one N atom of the penta-dentate macrocyclic ligand in the other axial position and four N atoms of the ligand in equatorial positions, defining a distorted octa-hedral coordination geometry. The macrocyclic ligand is coordinated to the Co(III) atom within a 5, 6, 5 arrangement of chelate rings in the equatorial plane of the four N atoms. Due to symmetry, the configuration of the chiral N atoms is 1RS, 4SR, 10RS, 13SR. In the crystal, N-H⋯Br, O-H⋯Br and N-H⋯O hydrogen bonds between the complex cation, anions and lattice water mol-ecules generate a three-dimensional network.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...