1.
ACS Sens ; 8(6): 2309-2318, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37224474

RESUMEN

We adapted an existing, spaceflight-proven, robust "electronic nose" (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using "leave-one-out" training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.


Asunto(s)
COVID-19 , Nanoestructuras , Compuestos Orgánicos Volátiles , Animales , Humanos , Nariz Electrónica , Reproducibilidad de los Resultados , COVID-19/diagnóstico , Pruebas Respiratorias/métodos , Compuestos Orgánicos Volátiles/análisis , Mamíferos
2.
Sensors (Basel) ; 22(19)2022 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-36236680

RESUMEN

Composites of functionalized single walled carbon nanotubes (SWCNTs) and gold nanoparticles (Au NPs) of ≈15 nm diameter were drop-cast on a printed circuit board (PCB) substrate equipped with interdigitated electrodes to make a hybrid thin film. Addition of Au NPs decorated the surface of SWCNTs networked films and acted as catalysts which resulted into an enhanced sensitivity and low ppb concentration detection limit. The compositions of the film were characterized by scanning electron microscope (SEM). SWCNTs clusters were loaded with various amount of Au NPs ranging from 1-10% (by weight) and their effect on Nitric oxide (NO) sensitivity was studied and optimized. Further, the optimized composite films were tested in both air and nitrogen environments and as well as over a wide relative humidity range (0-97%). Sensors were also tested for the selectivity by exposing to various gases such as nitrous oxide, ammonia, carbon monoxide, sulfur dioxide and acetone. Sensitivity to NO was found much higher than the other tested gases. The advantage of this sensor is that it is sensitive to NO at low ppb level (10 ppb) with estimated response time within 10 s and recovery time around 1 min, and has excellent reproducibility from sensor to sensor and works within the wide range of relative humidity (0-97%).


Asunto(s)
Nanopartículas del Metal , Nanotubos de Carbono , Acetona , Amoníaco , Monóxido de Carbono , Electrodos , Oro/química , Humedad , Nanopartículas del Metal/química , Nanotubos de Carbono/química , Óxido Nítrico , Nitrógeno , Óxido Nitroso , Reproducibilidad de los Resultados , Dióxido de Azufre
3.
Sensors (Basel) ; 19(18)2019 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-31489885

RESUMEN

Detection of carbon dioxide (CO2) is very important for environmental, health, safety and space applications. We have studied novel multiwall carbon nanotubes (MWCNTs) and an iron oxide (Fe2O3) nanocomposite based chemiresistive sensor for detection of CO2 at room temperature. The sensor has been miniaturized to a chip size (1 cm × 2 cm). Good sensing performance was observed with a wide detection range of CO2 concentrations (100-6000 ppm). Structural properties of the sensing materials were characterized using Field-Emission Scanning Electron Microscopy, Fourier-Transform Infrared and Raman spectroscopies. The greatly improved sensitivity of the composite materials to CO2 can be attributed to the formation of a depletion layer at the p-n junction in an MWCNT/iron oxide heterostructure, and new CO2 gas molecules adhere to the high surface area of MWCNTs due to the concentration gradient. The test results showed that the CO2 sensor possesses fast response, compact size, ultra-low power consumption, high sensitivity and wide dynamic detection range.

4.
Sensors (Basel) ; 16(8)2016 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-27463716

RESUMEN

We address the sensitive detection and discrimination of gases impacting the environment, such as CH4, NH3, SO2, and CO, using a sensor array and aided by principal component analysis (PCA). A 32-element chemiresistive sensor array consisting of nine different sensor materials including seven types of modified single-walled carbon nanotubes and two types of polymers has been constructed. PCA results demonstrate excellent discriminating ability of the chemiresistor sensor chip in the 1-30 ppm concentration range. The accuracy of the sensor was verified against data collected using cavity ring down spectroscopy. The sensor chip has also been integrated with a smartphone and has been shown to reproduce the sensing performance obtained with the laboratory measurement system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...