Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
MAGMA ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38743376

RESUMEN

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

2.
Tomography ; 9(5): 1839-1856, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37888738

RESUMEN

Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.


Asunto(s)
Artefactos , Hígado , Estudios Retrospectivos , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Movimiento (Física) , Imagen de Difusión por Resonancia Magnética/métodos
3.
J Clin Med ; 12(11)2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37297861

RESUMEN

Trimalleolar ankle fractures show a bimodal age distribution, affecting younger men and older women. Postmenopausal women often exhibit low bone mineral density, which contributes to a higher prevalence of osteoporotic-related fractures. The primary goal of this study was to analyse the association of patient characteristics with the cortical bone thickness of the distal tibia (CBTT) in trimalleolar ankle fractures. METHODS: A total of 193 patients with a trimalleolar ankle fracture treated between 2011 and 2020 were included. Patient registries were reviewed regarding demographics, mechanism, and type of injury. The CBTT was assessed in radiographs and CT images. The FRAX score was calculated to estimate the probability for an osteoporotic fracture. A multivariable regression model was calculated to identify independent variables affecting the cortical bone thickness of the distal tibia. RESULTS: Patients older than 55 years were 4.22 (95% CI: 2.12; 8.38) times more likely to be female. In the multivariable regression analysis, female sex (ß -0.508, 95% CI: -0.739; -0.278, p < 0.001) and a higher age (ß -0.009, 95% CI: -0.149; -0.003, p = 0.002) were independent variables associated with a lower CBTT. Patients with a CBTT < 3.5 mm had a higher 10-year probability for a major osteoporotic fracture (12% vs. 7.75%; p = 0.001). CONCLUSIONS: The assessment of the peripheral bone quality in routine computed tomography demonstrated that higher age and female sex are significantly associated with reduced cortical bone thickness of the distal tibia. Patients with a lower CBTT showed a higher probability for a subsequent osteoporotic fracture. In female patients with reduced distal tibial bone quality and associated risk factors, an osteoporosis assessment should be evaluated.

4.
Eur Radiol ; 33(10): 6892-6901, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37133518

RESUMEN

OBJECTIVES: To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS: Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS: High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS: High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT: This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS: • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.


Asunto(s)
Neoplasias Intraductales Pancreáticas , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagen , Relación Señal-Ruido , Imagen de Difusión por Resonancia Magnética/métodos , Páncreas
5.
Abdom Radiol (NY) ; 48(7): 2449-2455, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37160473

RESUMEN

Active surveillance (AS) is now included in all major guidelines for patients with low-risk PCa and selected patients with intermediate-risk PCa. Several studies have highlighted the potential benefit of multiparametric magnetic resonance imaging (mpMRI) in AS and it has been adopted in some guidelines. However, uncertainty remains about whether serial mpMRI can help to safely reduce the number of required repeat biopsies under AS. In 2017, the European School of Oncology initiated the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) panel which proposed the PRECISE scoring system to assess the likelihood of radiological tumor progression on serial mpMRI. The PRECISE scoring system remains the only major system evaluated in multiple publications. In this review article, we discuss the current body of literature investigating the application of PRECISE as it is not as yet an established standard in mpMRI reporting. We delineate the strengths of PRECISE and its potential added value. Also, we underline potential weaknesses of the PRECISE scoring system, which might be tackled in future versions to further increase its value in AS.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Espera Vigilante/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Radiografía
6.
Eur Radiol ; 33(8): 5840-5850, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37074425

RESUMEN

OBJECTIVES: Previous trial results suggest that only a small number of patients with non-metastatic renal cell carcinoma (RCC) benefit from adjuvant therapy. We assessed whether the addition of CT-based radiomics to established clinico-pathological biomarkers improves recurrence risk prediction for adjuvant treatment decisions. METHODS: This retrospective study included 453 patients with non-metastatic RCC undergoing nephrectomy. Cox models were trained to predict disease-free survival (DFS) using post-operative biomarkers (age, stage, tumor size and grade) with and without radiomics selected on pre-operative CT. Models were assessed using C-statistic, calibration, and decision curve analyses (repeated tenfold cross-validation). RESULTS: At multivariable analysis, one of four selected radiomic features (wavelet-HHL_glcm_ClusterShade) was prognostic for DFS with an adjusted hazard ratio (HR) of 0.44 (p = 0.02), along with American Joint Committee on Cancer (AJCC) stage group (III versus I, HR 2.90; p = 0.002), grade 4 (versus grade 1, HR 8.90; p = 0.001), age (per 10 years HR 1.29; p = 0.03), and tumor size (per cm HR 1.13; p = 0.003). The discriminatory ability of the combined clinical-radiomic model (C = 0.80) was superior to that of the clinical model (C = 0.78; p < 0.001). Decision curve analysis revealed a net benefit of the combined model when used for adjuvant treatment decisions. At an exemplary threshold probability of ≥ 25% for disease recurrence within 5 years, using the combined versus the clinical model was equivalent to treating 9 additional patients (per 1000 assessed) who would recur without treatment (i.e., true-positive predictions) with no increase in false-positive predictions. CONCLUSION: Adding CT-based radiomic features to established prognostic biomarkers improved post-operative recurrence risk assessment in our internal validation study and may help guide decisions regarding adjuvant therapy. KEY POINTS: In patients with non-metastatic renal cell carcinoma undergoing nephrectomy, CT-based radiomics combined with established clinical and pathological biomarkers improved recurrence risk assessment. Compared to a clinical base model, the combined risk model enabled superior clinical utility if used to guide decisions on adjuvant treatment.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Humanos , Niño , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Estudios Retrospectivos , Recurrencia Local de Neoplasia/cirugía , Nefrectomía , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Renales/tratamiento farmacológico , Tomografía Computarizada por Rayos X/métodos
7.
Invest Radiol ; 58(3): 199-208, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36070524

RESUMEN

OBJECTIVE: Before implementing radiomics in routine clinical practice, comprehensive knowledge about the repeatability and reproducibility of radiomic features is required. The aim of this study was to systematically investigate the influence of image processing parameters on radiomic features from magnetic resonance imaging (MRI) in terms of feature values as well as test-retest repeatability. MATERIALS AND METHODS: Utilizing a phantom consisting of 4 onions, 4 limes, 4 kiwifruits, and 4 apples, we acquired a test-retest dataset featuring 3 of the most commonly used MRI sequences on a 3 T scanner, namely, a T1-weighted, a T2-weighted, and a fluid-attenuated inversion recovery sequence, each at high and low resolution. After semiautomatic image segmentation, image processing with systematic variation of image processing parameters was performed, including spatial resampling, intensity discretization, and intensity rescaling. For each respective image processing setting, a total of 45 radiomic features were extracted, corresponding to the following 7 matrices/feature classes: conventional indices, histogram matrix, shape matrix, gray-level zone length matrix, gray-level run length matrix, neighboring gray-level dependence matrix, and gray-level cooccurrence matrix. Systematic differences of individual features between different resampling steps were assessed using 1-way analysis of variance with Tukey-type post hoc comparisons to adjust for multiple testing. Test-retest repeatability of radiomic features was measured using the concordance correlation coefficient, dynamic range, and intraclass correlation coefficient. RESULTS: Image processing influenced radiological feature values. Regardless of the acquired sequence and feature class, significant differences ( P < 0.05) in feature values were found when the size of the resampled voxels was too large, that is, bigger than 3 mm. Almost all higher-order features depended strongly on intensity discretization. The effects of intensity rescaling were negligible except for some features derived from T1-weighted sequences. For all sequences, the percentage of repeatable features (concordance correlation coefficient and dynamic range ≥ 0.9) varied considerably depending on the image processing settings. The optimal image processing setting to achieve the highest percentage of stable features varied per sequence. Irrespective of image processing, the fluid-attenuated inversion recovery sequence in high-resolution overall yielded the highest number of stable features in comparison with the other sequences (89% vs 64%-78% for the respective optimal image processing settings). Across all sequences, the most repeatable features were generally obtained for a spatial resampling close to the originally acquired voxel size and an intensity discretization to at least 32 bins. CONCLUSION: Variation of image processing parameters has a significant impact on the values of radiomic features as well as their repeatability. Furthermore, the optimal image processing parameters differ for each MRI sequence. Therefore, it is recommended that these processing parameters be determined in corresponding test-retest scans before clinical application. Extensive repeatability, reproducibility, and validation studies as well as standardization are required before quantitative image analysis and radiomics can be reliably translated into routine clinical care.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen
8.
Cancers (Basel) ; 14(23)2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36497223

RESUMEN

BACKGROUND: To assess the performance of prospectively accelerated and deep learning (DL) reconstructed T2-weighted (T2w) imaging in volunteers and patients with histologically proven prostate cancer (PCa). METHODS: Prospectively undersampled T2w datasets were acquired with acceleration factors of 1.7 (reference), 3.4 and 4.8 in 10 healthy volunteers and 23 patients with histologically proven PCa. Image reconstructions using compressed SENSE (C-SENSE) and a combination of C-SENSE and DL-based artificial intelligence (C-SENSE AI) were analyzed. Qualitative image comparison was performed using a 6-point Likert scale (overall image quality, noise, motion artifacts, lesion detection, diagnostic certainty); the T2 and PI-RADS scores were compared between the two reconstructions. Additionally, quantitative image parameters were assessed (apparent SNR, apparent CNR, lesion size, line profiles). RESULTS: All C-SENSE AI-reconstructed images received a significantly higher qualitative rating compared to the C-SENSE standard images. Analysis of the quantitative parameters supported this finding, with significantly higher aSNR and aCNR. The line profiles demonstrated a significantly steeper signal change at the border of the prostatic lesion and the adjacent normal tissue in the C-SENSE AI-reconstructed images, whereas the T2 and PI-RADS scores as well as the lesion size did not differ. CONCLUSION: In this prospective study, we demonstrated the clinical feasibility of a novel C-SENSE AI reconstruction enabling a 58% acceleration in T2w imaging of the prostate while obtaining significantly better image quality.

9.
Eur J Nucl Med Mol Imaging ; 50(1): 115-129, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36074156

RESUMEN

PURPOSE: Pancreatic ductal adenocarcinoma (PDAC) is a molecularly heterogeneous tumor entity with no clinically established imaging biomarkers. We hypothesize that tumor morphology and physiology, including vascularity and perfusion, show variations that can be detected by differences in contrast agent (CA) accumulation measured non-invasively. This work seeks to establish imaging biomarkers for tumor stratification and therapy response monitoring in PDAC, based on this hypothesis. METHODS AND MATERIALS: Regional CA accumulation in PDAC was correlated with tumor vascularization, stroma content, and tumor cellularity in murine and human subjects. Changes in CA distribution in response to gemcitabine (GEM) were monitored longitudinally with computed tomography (CT) Hounsfield Units ratio (HUr) of tumor to the aorta or with magnetic resonance imaging (MRI) ΔR1 area under the curve at 60 s tumor-to-muscle ratio (AUC60r). Tissue analyses were performed on co-registered samples, including endothelial cell proliferation and cisplatin tissue deposition as a surrogate of chemotherapy delivery. RESULTS: Tumor cell poor, stroma-rich regions exhibited high CA accumulation both in human (meanHUr 0.64 vs. 0.34, p < 0.001) and mouse PDAC (meanAUC60r 2.0 vs. 1.1, p < 0.001). Compared to the baseline, in vivo CA accumulation decreased specifically in response to GEM treatment in a subset of human (HUr -18%) and mouse (AUC60r -36%) tumors. Ex vivo analyses of mPDAC showed reduced cisplatin delivery (GEM: 0.92 ± 0.5 mg/g, vs. vehicle: 3.1 ± 1.5 mg/g, p = 0.004) and diminished endothelial cell proliferation (GEM: 22.3% vs. vehicle: 30.9%, p = 0.002) upon GEM administration. CONCLUSION: In PDAC, CA accumulation, which is related to tumor vascularization and perfusion, inversely correlates with tumor cellularity. The standard of care GEM treatment results in decreased CA accumulation, which impedes drug delivery. Further investigation is warranted into potentially detrimental effects of GEM in combinatorial therapy regimens.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Ratones , Animales , Cisplatino/uso terapéutico , Ensayos Antitumor por Modelo de Xenoinjerto , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/tratamiento farmacológico , Carcinoma Ductal Pancreático/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/patología , Neovascularización Patológica/diagnóstico por imagen , Neovascularización Patológica/tratamiento farmacológico , Biomarcadores , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética , Tomografía , Línea Celular Tumoral , Gemcitabina , Neoplasias Pancreáticas
10.
Front Oncol ; 12: 938703, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35865465

RESUMEN

Introduction: Exposure of the posterior skull base and the cerebellopontine angle is challenging due to important neurovascular structures. The retrosigmoid approach (RSA) has become the standard method used in surgery. We report our experiences with RSAs regarding technical obstacles, complications, and approach-related outcomes. Materials and Methods: We performed a retrospective chart review at a tertiary neurosurgical center between January 2007 and September 2020. We included all patients undergoing surgery for oncologic lesions through RSAs, concentrating on surgical technique, postoperative outcome, and complications. Results: A total of 449 RSAs were included. The median age at the time of surgery was 58 years; 168 (37.4%) were male and 281 (62.6%) were female. The median approach surface was 7.8 cm2. The median tumor volume was 5.9 cm3. The median Clavien-Dindo grade was 2, the total complication rate was 28.7%, and gross total resection (GTR) was 78.8%. Findings revealed that tumor volume had no significant impact on postoperative complications in general (p = 0.086) but had a significant impact on postoperative hemorrhage (p = 0.037) and hydrocephalus (p = 0.019). Tumor volume was significant for several preoperative symptoms (p < 0.001). The extent of the approach had no significant impact on complications in general (p = 0.120) but was significant regarding postoperative cerebrospinal fluid (CSF) leaks (p = 0.008). Craniotomy size was not significant regarding GTR (p = 0.178); GTR rate just missed significant correlation with tumor volume (p = 0.056). However, in the case of vestibular schwannomas, the size of craniotomy was important for GTR (p = 0.041). Conclusion: Tumor volume has an important impact on preoperative symptoms as well as on postoperative complications. Although the extent of the craniotomy barely missed significance regarding GTR, a correlation can be assumed. Thus, the extent of craniotomy should be taken into presurgical consideration, especially in the case of postoperative CSF leaks. Regarding vestibular schwannomas, craniotomy size plays an important role in achieving satisfactory oncological outcomes. Different approaches should be selected where necessary regarding superior resection rates.

11.
EMBO Mol Med ; 14(4): e14876, 2022 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-35119792

RESUMEN

Despite the advance and success of precision oncology in gastrointestinal cancers, the frequency of molecular-informed therapy decisions in pancreatic ductal adenocarcinoma (PDAC) is currently neglectable. We present a longitudinal precision oncology platform based on functional model systems, including patient-derived organoids, to identify chemotherapy-induced vulnerabilities. We demonstrate that treatment-induced tumor cell plasticity in vivo distinctly changes responsiveness to targeted therapies, without the presence of a selectable genetic marker, indicating that tumor cell plasticity can be functionalized. By adding a mechanistic layer to precision oncology, adaptive processes of tumors under therapy can be exploited, particularly in highly plastic tumors, such as pancreatic cancer.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Carcinoma Ductal Pancreático/tratamiento farmacológico , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/patología , Humanos , Organoides/patología , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/patología , Medicina de Precisión , Neoplasias Pancreáticas
12.
Cancers (Basel) ; 14(3)2022 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-35158737

RESUMEN

BACKGROUND: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. MATERIALS AND METHODS: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1-4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). RESULTS: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. CONCLUSION: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.

13.
Magn Reson Imaging ; 87: 1-6, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34808306

RESUMEN

OBJECTIVES: To prospectively evaluate an L1 regularized iterative SENSE reconstruction (L1-R SENSE) to eliminate band-like artifacts frequently seen with parallel imaging (SENSE) at high acceleration factors in high resolution diffusion weighted magnetic resonance imaging of the pancreas. METHODS: Fourteen patients with pancreatic ductal adenocarcinoma (PDAC) underwent respiratory triggered DWI ss-EPI at a resolution of 2.5 × 2.5 × 3 mm3 with uniform undersampling in the phase encoding direction (AP axis) with an acceleration factor of 4. Data were reconstructed using the standard SENSE reconstruction routine of the vendor and an iterative SENSE reconstruction employing L1 regularization after a wavelet sparsifying transformation (L1-R SENSE). Retrospective reconstruction of the data with a lower number of averages was performed using both reconstruction methods. Two radiologists independently assessed noise artifacts, anatomical details and image quality (IQ) subjectively with a 4-point scale. Apparent diffusion coefficient (ADC) and covariance (CV) of ADC estimated from images reconstructed at a different number of averages for PDAC and the normal pancreas were assessed. RESULTS: L1-R SENSE resulted in higher IQ and less noise artifacts than SENSE. Anatomical details were significantly higher for SENSE in one reader. Mean ADC of PDAC and normal pancreas were significantly higher for L1-R SENSE than SENSE. L1-R SENSE revealed lower CV of ADC for normal pancreas compared to SENSE, whereas no difference was noted for PDAC. CONCLUSION: Compared with traditional SENSE reconstruction, L1-R SENSE effectively reduces band-like noise and improves the robustness of the ADC estimation from acquisitions using single-shot DW-EPI of the pancreas.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Humanos , Páncreas/diagnóstico por imagen , Páncreas/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos
14.
EJNMMI Res ; 11(1): 70, 2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34322781

RESUMEN

PURPOSE: In this prospective exploratory study, we evaluated the feasibility of [18F]fluorodeoxyglucose ([18F]FDG) PET/MRI-based chemotherapy response prediction in pancreatic ductal adenocarcinoma at two weeks upon therapy onset. MATERIAL AND METHODS: In a mixed cohort, seventeen patients treated with chemotherapy in neoadjuvant or palliative intent were enrolled. All patients were imaged by [18F]FDG PET/MRI before and two weeks after onset of chemotherapy. Response per RECIST1.1 was then assessed at 3 months [18F]FDG PET/MRI-derived parameters (MTV50%, TLG50%, MTV2.5, TLG2.5, SUVmax, SUVpeak, ADCmax, ADCmean and ADCmin) were assessed, using multiple t-test, Man-Whitney-U test and Fisher's exact test for binary features. RESULTS: At 72 ± 43 days, twelve patients were classified as responders and five patients as non-responders. An increase in ∆MTV50% and ∆ADC (≥ 20% and 15%, respectively) and a decrease in ∆TLG50% (≤ 20%) at 2 weeks after chemotherapy onset enabled prediction of responders and non-responders, respectively. Parameter combinations (∆TLG50% and ∆ADCmax or ∆MTV50% and ∆ADCmax) further improved discrimination. CONCLUSION: Multiparametric [18F]FDG PET/MRI-derived parameters, in particular indicators of a change in tumor glycolysis and cellularity, may enable very early chemotherapy response prediction. Further prospective studies in larger patient cohorts are recommended to their clinical impact.

15.
Eur J Radiol ; 142: 109843, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34274842

RESUMEN

OBJECTIVES: To evaluate sparse sampling computed tomography (SpSCT) for detection of endoleak after endovascular aortic repair (EVAR) at different dose levels in terms of subjective image criteria and diagnostic accuracy. METHODS: Twenty clinically indicated computed tomography aortic angiography (CTA) scans were used to obtain simulated low-dose scans with 100%, 50%, 25%, 12.5% and 6.25% of the applicated clinical dose, resulting in five dose levels (DL). From full sampling (FS) data sets, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to generate simulated sparse sampling scans. All examinations were evaluated by four blinded radiologists regarding subjective image criteria and diagnostic performance. RESULTS: Sensitivity was higher than 93% in 4-SpSCT at the 25% DL which is the same as with FS at full dose (100% DL). High accuracies and relative high AUC-values were obtained for 2- and 4-SpSCT down to the 12.5% DL, while for FS similar values were shown down to 25% DL only. Subjective image quality was significantly higher for 4-SpSCT compared to FS at each dose level. More than 90% of all cases were rated with a high or medium confidence for FS and 2-SpSCT at the 50% DL and for 4-SpSCT at the 25% DL. At DL 25% and 12.5%, more cases showed a high confidence using 2- and 4-SpSCT compared with FS. CONCLUSIONS: Via SpSCT, a dose reduction down to a 25% dose level (mean effective dose of 1.49 mSv in the current study) for CTA is possible while maintaining high image quality and full diagnostic confidence.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
16.
Invest Radiol ; 56(7): 433-441, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33813577

RESUMEN

OBJECTIVES: The aim of this study was to intraindividually compare the performance of 2 compressed sensing (CS)-accelerated magnetic resonance imaging (MRI) sequences, 1 featuring Cartesian (compressed sensing volumetric interpolated breath-hold examination [CS-VIBE]) and the other radial (golden-angle radial sparse parallel [GRASP]) k-space sampling in continuous dynamic imaging during hepatic vascular phases, using extracellular and hepatocyte-specific contrast agents. MATERIALS AND METHODS: Seven New Zealand white rabbits, with induced VX2 liver tumors (median number of lesions, 2 ± 0.83; range, 1-3), received 2 continuously acquired T1-weighted prototype CS-accelerated MRI sequences (CS-VIBE and GRASP) with high spatial (0.8 × 0.8 × 1.5 mm) and temporal resolution (3.5 seconds) in randomized order on 2 separate days using a 1.5-T scanner. In all animals, imaging was performed using first gadobutrol at a dose of 0.1 mmol/kg and, then 45 minutes later, gadoxetic acid at a dose of 0.025 mmol/kg.The following qualitative parameters were assessed using 3- and 5-point Likert scales (3 and 5 being the highest scores respectively): image quality (IQ), arterial and venous vessel delineation, tumor enhancement, motion artifacts, and sequence-specific artifacts. Furthermore, the following quantitative parameters were obtained: relative peak signal enhancement, time to peak, mean transit time, and plasma flow ratios. Paired sampled t tests and Wilcoxon signed rank tests were used for intraindividual comparison. Image analysis was performed by 2 radiologists. RESULTS: Six of 7 animals underwent the full imaging protocol and obtained data were analyzed statistically. Overall IQ was rated moderate to excellent, not differing significantly between the 2 sequences.Gadobutrol-enhanced CS-VIBE examinations revealed the highest mean Likert scale values in terms of vessel delineation and tumor enhancement (arterial 4.4 [4-5], venous 4.3 [3-5], and tumor 2.9 [2-3]). Significantly, more sequence-specific artifacts were seen in GRASP examinations (P = 0.008-0.031). However, these artifacts did not impair IQ. Excellent Likert scale ratings were found for motion artifacts in both sequences. In both sequences, a maximum of 4 hepatic arterial dominant phases were obtained. Regarding the relative peak signal enhancement, CS-VIBE and GRASP showed similar results. The relative peak signal enhancement values did not differ significantly between the 2 sequences in the aorta, the hepatic artery, or the inferior vena cava (P = 0.063-0.536). However, significantly higher values were noted for CS-VIBE in gadoxetic acid-enhanced examinations in the portal vein (P = 0.031) and regarding the tumor enhancement (P = 0.005). Time to peak and mean transit time or plasma flow ratios did not differ significantly between the sequences. CONCLUSIONS: Both CS-VIBE and GRASP provide excellent results in dynamic liver MRI using extracellular and hepatocyte-specific contrast agents, in terms of IQ, peak signal intensity, and presence of artifacts.


Asunto(s)
Neoplasias Hepáticas , Neoplasias Experimentales , Animales , Artefactos , Contencion de la Respiración , Medios de Contraste , Aumento de la Imagen , Imagenología Tridimensional , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Conejos
17.
Acad Radiol ; 28 Suppl 1: S234-S243, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33390324

RESUMEN

RATIONALE AND OBJECTIVES: To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas. MATERIALS AND METHODS: We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]). RESULTS: All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images. CONCLUSION: rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Humanos , Páncreas/diagnóstico por imagen , Reproducibilidad de los Resultados
18.
J Clin Med ; 9(5)2020 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-32344944

RESUMEN

RATIONALE: Pancreatic ductal adenocarcinoma (PDAC) remains a tumor entity of exceptionally poor prognosis, and several biomarkers are under current investigation for the prediction of patient prognosis. Many studies focus on promoting newly developed imaging biomarkers without a rigorous comparison to other established parameters. To assess the true value and leverage the potential of all efforts in this field, a multi-parametric evaluation of the available biomarkers for PDAC survival prediction is warranted. Here we present a multiparametric analysis to assess the predictive value of established parameters and the added contribution of newly developed imaging features such as biomarkers for overall PDAC patient survival. METHODS: 103 patients with resectable PDAC were retrospectively enrolled. Clinical and histopathological data (age, sex, chemotherapy regimens, tumor size, lymph node status, grading and resection status), morpho-molecular and genetic data (tumor morphology, molecular subtype, tp53, kras, smad4 and p16 genetics), image-derived features and the combination of all parameters were tested for their prognostic strength based on the concordance index (CI) of multivariate Cox proportional hazards survival modelling after unsupervised machine learning preprocessing. RESULTS: The average CIs of the out-of-sample data were: 0.63 for the clinical and histopathological features, 0.53 for the morpho-molecular and genetic features, 0.65 for the imaging features and 0.65 for the combined model including all parameters. CONCLUSIONS: Imaging-derived features represent an independent survival predictor in PDAC and enable the multiparametric, machine learning-assisted modelling of postoperative overall survival with a high performance compared to clinical and morpho-molecular/genetic parameters. We propose that future studies systematically include imaging-derived features to benchmark their additive value when evaluating biomarker-based model performance.

19.
J Clin Med ; 9(3)2020 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-32155990

RESUMEN

To bridge the translational gap between recent discoveries of distinct molecular phenotypes of pancreatic cancer and tangible improvements in patient outcome, there is an urgent need to develop strategies and tools informing and improving the clinical decision process. Radiomics and machine learning approaches can offer non-invasive whole tumor analytics for clinical imaging data-based classification. The retrospective study assessed baseline computed tomography (CT) from 207 patients with proven pancreatic ductal adenocarcinoma (PDAC). Following expert level manual annotation, Pyradiomics was used for the extraction of 1474 radiomic features. The molecular tumor subtype was defined by immunohistochemical staining for KRT81 and HNF1a as quasi-mesenchymal (QM) vs. non-quasi-mesenchymal (non-QM). A Random Forest machine learning algorithm was developed to predict the molecular subtype from the radiomic features. The algorithm was then applied to an independent cohort of histopathologically unclassifiable tumors with distinct clinical outcomes. The classification algorithm achieved a sensitivity, specificity and ROC-AUC (area under the receiver operating characteristic curve) of 0.84 ± 0.05, 0.92 ± 0.01 and 0.93 ± 0.01, respectively. The median overall survival for predicted QM and non-QM tumors was 16.1 and 20.9 months, respectively, log-rank-test p = 0.02, harzard ratio (HR) 1.59. The application of the algorithm to histopathologically unclassifiable tumors revealed two groups with significantly different survival (8.9 and 39.8 months, log-rank-test p < 0.001, HR 4.33). The machine learning-based analysis of preoperative (CT) imaging allows the prediction of molecular PDAC subtypes highly relevant for patient survival, allowing advanced pre-operative patient stratification for precision medicine applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA