RESUMEN
In an effort to standardize and evaluate the performance of electrocardiographic computer measurement programs, a 15 lead reference library has been developed based on simultaneously recorded standard 12 lead and orthogonal XYZ lead data. A set of 250 electrocardiograms (ECGs) with selected abnormalities was analyzed by a group of five referee cardiologists and 11 different 12 lead and 6 XYZ computer programs. Attention was focused on the exact determination of the onsets and offsets of P, QRS and T waves. The referees performed their task on highly amplified, selected complexes from the library in a two round process. Median results of the referees coincided best with the median derived from all programs. An analysis of stability proved that the combined program median was a robust reference. However, some individual program results were widely divergent. Paired t tests demonstrated earlier onset for P and QRS (p less than 0.001), as well as later offset for P and T waves in the median 12 lead than in the XYZ results. Significant differences also existed among results obtained by programs analyzing all standard ECG leads at one time, the so-called multilead programs, and those obtained by the conventional standard three lead analysis programs. As a consequence, the derived P, PR, QRS and QT interval measurements varied quite widely among the various programs. Significant differences were also observed among measurements of Q, R and S duration. Some programs showed Q waves that were on the average 6 ms (p less than 0.001) longer than those of others. This may significantly influence diagnostic performance.(ABSTRACT TRUNCATED AT 250 WORDS)
Asunto(s)
Electrocardiografía , Interpretación de Imagen Asistida por Computador , Sistemas de Información , Humanos , Programas InformáticosRESUMEN
The development of a data base is described which can be used as common reference for ECG computer programs analyzing 12 or 15 simultaneously recorded leads. This data base is an extension of the 3-lead CSE reference library, described previously.
Asunto(s)
Electrocardiografía , Sistemas de Información , Procesamiento de Señales Asistido por Computador , Programas Informáticos , HumanosRESUMEN
As a result of an international cooperative project entitled "Common Standards for Quantitative Electrocardiography" (CSE), an ECG reference data base has been established with the aim of standardizing computer-derived ECG measurements. The objective of the project is to reduce the wide variation in wave measurements currently obtained by ECG analysis programs. A library of 250 ECGs with selective ECG abnormalities was established and a comprehensive reviewing scheme was devised for the visual determination of the onsets and offsets of P, QRS, and T. This task was performed by a board of cardiologists on highly amplified, selected complexes from the library. A subset was examined in order to study beat-to-beat and intraobserver variability. By using a modified Delphi approach, individual outlying point estimates were eliminated in four successive rounds. In this way final referee estimates were obtained which proved to be highly reproducible and precise. A reference library has thereby been developed which allows testing of the performance of ECG measurement programs and is a useful instrument in establishing recommendations for more precise measurement rules and definitions.