Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Health Commun ; 38(14): 3316-3325, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36636017

RESUMEN

As frontline providers, first responders are not always thought of as patients with unique health beliefs. During early and continued distribution, many first responders in the United States chose to refuse vaccination. Guided by the health belief model and emerging research related to SARS-COV-2, the aim of this study was to further explore the complex message conditions that contributed to first responders' early vaccination decisions. An online survey was conducted between March 1 and March 31 2021, among first responders in the state of Kentucky, which has lagged behind most states in the percentage of the population who are fully vaccinated. The first responder sample included Firefighters, Emergency Medical Technicians (EMTs), and paramedics who completed a Qualtrics survey that included measures aimed at assessing health beliefs about SARS-COV-2, beliefs about SARS-COV-2 vaccines, source trustworthiness, and vaccine motivation. First responders were also asked to rank the importance of various information sources about SARS-COV-2 and its vaccines. Findings suggest significant differences exist among first responders who have chosen to receive SARS-COV-2 vaccines and those who have refused, including source preference, conspiracy beliefs, and perceived risk. Future directions, including the exploration of institutional mistrust as a health belief are discussed. These findings offer practical insights that may improve continuing approaches to discover and use preferred communication sources to reach the vaccine-hesitant.


Asunto(s)
COVID-19 , Socorristas , Humanos , SARS-CoV-2 , Vacunas contra la COVID-19/uso terapéutico , COVID-19/prevención & control , Vacunación
2.
J Nucl Med ; 63(11): 1693-1700, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35332092

RESUMEN

Clinical imaging performance using a fluorescent antibody was compared across 3 cancers to elucidate physical and biologic factors contributing to differential translation of epidermal growth factor receptor (EGFR) expression to macroscopic fluorescence in tumors. Methods: Thirty-one patients with high-grade glioma (HGG, n = 5), head-and-neck squamous cell carcinoma (HNSCC, n = 23), or lung adenocarcinoma (LAC, n = 3) were systemically infused with 50 mg of panitumumab-IRDye800 1-3 d before surgery. Intraoperative open-field fluorescent images of the surgical field were acquired, with imaging device settings and operating room lighting conditions being tested on tissue-mimicking phantoms. Fluorescence contrast and margin size were measured on resected specimen surfaces. Antibody distribution and EGFR immunoreactivity were characterized in macroscopic and microscopic histologic structures. The integrity of the blood-brain barrier was examined via tight junction protein (Claudin-5) expression with immunohistochemistry. Stepwise multivariate linear regression of biologic variables was performed to identify independent predictors of panitumumab-IRDye800 concentration in tissue. Results: Optimally acquired at the lowest gain for tumor detection with ambient light, intraoperative fluorescence imaging enhanced tissue-size dependent tumor contrast by 5.2-fold, 3.4-fold, and 1.4-fold in HGG, HNSCC, and LAC, respectively. Tissue surface fluorescence target-to-background ratio correlated with margin size and identified 78%-97% of at-risk resection margins ex vivo. In 4-µm-thick tissue sections, fluorescence detected tumor with 0.85-0.89 areas under the receiver-operating-characteristic curves. Preferential breakdown of blood-brain barrier in HGG improved tumor specificity of intratumoral antibody distribution relative to that of EGFR (96% vs. 80%) despite its reduced concentration (3.9 ng/mg of tissue) compared with HNSCC (8.1 ng/mg) and LAC (6.3 ng/mg). Cellular EGFR expression, tumor cell density, plasma antibody concentration, and delivery barrier were independently associated with local intratumoral panitumumab-IRDye800 concentration, with 0.62 goodness of fit of prediction. Conclusion: In multicancer clinical imaging of a receptor-ligand-based molecular probe, plasma antibody concentration, delivery barrier, and intratumoral EGFR expression driven by cellular biomarker expression and tumor cell density led to heterogeneous intratumoral antibody accumulation and spatial distribution whereas tumor size, resection margin, and intraoperative imaging settings substantially influenced macroscopic tumor contrast.


Asunto(s)
Neoplasias de Cabeza y Cuello , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello , Panitumumab , Imagen Óptica/métodos , Receptores ErbB/metabolismo , Márgenes de Escisión , Línea Celular Tumoral
3.
Cancers (Basel) ; 13(5)2021 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-33807778

RESUMEN

Malignant melanoma is the most aggressive type of skin cancer with invasive growth patterns. In 2021, 106,110 patients are projected to be diagnosed with melanoma, out of which 7180 are expected to die. Traditional methods like surgery, radiation therapy, and chemotherapy are not effective in the treatment of metastatic and advanced melanoma. Recent approaches to treat melanoma have focused on biomarkers that play significant roles in cell growth, proliferation, migration, and survival. Several FDA-approved molecular targeted therapies such as tyrosine kinase inhibitors (TKIs) have been developed against genetic biomarkers whose overexpression is implicated in tumorigenesis. The use of targeted therapies as an alternative or supplement to immunotherapy has revolutionized the management of metastatic melanoma. Although this treatment strategy is more efficacious and less toxic in comparison to traditional therapies, targeted therapies are less effective after prolonged treatment due to acquired resistance caused by mutations and activation of alternative mechanisms in melanoma tumors. Recent studies focus on understanding the mechanisms of acquired resistance to these current therapies. Further research is needed for the development of better approaches to improve prognosis in melanoma patients. In this article, various melanoma biomarkers including BRAF, MEK, RAS, c-KIT, VEGFR, c-MET and PI3K are described, and their potential mechanisms for drug resistance are discussed.

4.
Lancet Gastroenterol Hepatol ; 5(8): 753-764, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32416764

RESUMEN

BACKGROUND: Complete surgical resection remains the primary curative option for pancreatic ductal adenocarcinoma, with positive margins in 30-70% of patients. In this study, we aimed to evaluate the use of intraoperative tumour-specific imaging to enhance a surgeon's ability to detect visually occult cancer in real time. METHODS: In this single-centre, open-label, single-arm study, done in the USA, we enrolled patients who had clinically suspicious or biopsy-confirmed pancreatic ductal adenocarcinomas and were scheduled for curative surgery. Eligible patients were 19 years of age or older with a life expectancy of more than 12 weeks and a Karnofsky performance status of at least 70% or an Eastern Cooperative Oncology Group or Zubrod level of one or lower, who were scheduled to undergo curative surgery. Patients were sequentially enrolled into each dosing group and 2-5 days before surgery, patients were intravenously infused with 100 mg of unlabelled panitumumab followed by 25 mg, 50 mg, or 75 mg of the near-infrared fluorescently labelled antibody (panitumumab-IRDye800CW). The primary endpoint was to determine the optimal dose of panitumumab-IRDye800CW in identifying pancreatic ductal adenocarcinomas as measured by tumour-to-background ratio in all patients. The tumour-to-background ratio was defined as the fluorescence signal of the tumour divided by the fluorescence signal of the surrounding healthy tissue. The dose-finding part of this study has been completed. This study is registered with ClinicalTrials.gov, NCT03384238. FINDINGS: Between April, 2018, and July, 2019, 16 patients were screened for enrolment onto the study. Of the 16 screened patients, two (12%) patients withdrew from the study and three (19%) were not eligible; 11 (69%) patients completed the trial, all of whom were clinically diagnosed with pancreatic ductal adenocarcinoma. The mean tumour-to-background ratio of primary tumours was 3·0 (SD 0·5) in the 25 mg group, 4·0 (SD 0·6) in the 50 mg group, and 3·7 (SD 0·4) in the 75 mg group; the optimal dose was identified as 50 mg. Intraoperatively, near-infrared fluorescence imaging provided enhanced visualisation of the primary tumours, metastatic lymph nodes, and small (<2 mm) peritoneal metastasis. Intravenous administration of panitumumab-IRDye800CW at the doses of 25 mg, 50 mg, and 75 mg did not result in any grade 3 or higher adverse events. There were no serious adverse events attributed to panitumumab-IRDye800CW, although four possibly related adverse events (grade 1 and 2) were reported in four patients. INTERPRETATION: To our knowledge, this study presents the first clinical use of panitumumab-IRDye800CW for detecting pancreatic ductal adenocarcinomas and shows that panitumumab-IRDye800CW is safe and feasible to use during pancreatic cancer surgery. Tumour-specific intraoperative imaging might have added value for treatment of patients with pancreatic ductal adenocarcinomas through improved patient selection and enhanced visualisation of surgical margins, metastatic lymph nodes, and distant metastasis. FUNDING: National Institutes of Health and the Netherlands Organization for Scientific Research.


Asunto(s)
Antineoplásicos Inmunológicos/administración & dosificación , Bencenosulfonatos/administración & dosificación , Carcinoma Ductal Pancreático/cirugía , Indoles/administración & dosificación , Imagen Óptica/métodos , Neoplasias Pancreáticas/patología , Panitumumab/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/tratamiento farmacológico , Femenino , Humanos , Infusiones Intravenosas/métodos , Periodo Intraoperatorio , Metástasis Linfática/diagnóstico por imagen , Masculino , Márgenes de Escisión , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Países Bajos/epidemiología , Neoplasias Peritoneales/diagnóstico por imagen , Neoplasias Peritoneales/secundario
5.
Laryngoscope ; 130(12): 2811-2817, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31854462

RESUMEN

OBJECTIVE: Endoscopic resection of sinonasal squamous cell carcinoma has become the standard of care, but challenges remain in obtaining clear resection margins. The current study evaluated the feasibility of endoscopic fluorescence-guided surgery (FGS) to improve surgical resection in a human sinus surgical model. METHODS: A fluorescence endoscope optimized for near-infrared (NIR) fluorescence detection was evaluated in a phantom study. Various endoscope diameters (4 and 10 mm) and viewing angles (0, 30, and 45 degrees) were evaluated to determine the sensitivity of the system for IRDye800CW detection at various working distances (1-5 cm). Endoscopic FGS was then validated in a three-dimensional human sinus surgical model to which squamous cell tumors derived from mice were inserted. Mice had received intravenous panitumumab-IRDye800CW and upon fluorescence-guided tumor resection, mean fluorescence intensity (MFI) and tumor-to-background ratio (TBR) were calculated in in situ and ex vivo settings. RESULTS: A significantly higher fluorescence intensity was found when using the 10-mm diameter endoscope compared to the 4mm diameter endoscope (P < .001). No significant difference in MFI was found among the viewing angles of the 4-mm diameter endoscope. Using the human sinus model, the highest MFI and TBR were obtained at a 1-cm working distance compared to longer working distances. CONCLUSION: We demonstrate that clinically acceptable TBRs were obtained with several working distances to discriminate tumor tissue from adjacent normal tissue in a human sinus model, and that endoscopic FGS may have great potential in identifying residual tumor tissue regions during surgery. Laryngoscope, 2019.


Asunto(s)
Endoscopía/métodos , Imagen Óptica/métodos , Neoplasias de los Senos Paranasales/cirugía , Cirugía Asistida por Computador/métodos , Animales , Fluorescencia , Colorantes Fluorescentes , Humanos , Ratones , Panitumumab , Fantasmas de Imagen , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...