RESUMEN
Acting through a combination of direct and indirect pathogen clearance mechanisms, blood-derived antimicrobial compounds (AMCs) play a pivotal role in innate immunity, safeguarding the host against invading microorganisms. Besides their antimicrobial activity, some AMCs can neutralize endotoxins, preventing their interaction with immune cells and avoiding an excessive inflammatory response. In this study, we aimed to investigate the influence of unfractionated heparin, a polyanionic drug clinically used as anticoagulant, on the endotoxin-neutralizing and antibacterial activity of blood-derived AMCs. Serum samples from healthy donors were pre-incubated with increasing concentrations of heparin for different time periods and tested against pathogenic bacteria (Acinetobacter baumannii, Enterococcus faecium, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus) and endotoxins from E. coli, K. pneumoniae, and P. aeruginosa. Heparin dose-dependently decreased the activity of blood-derived AMCs. Consequently, pre-incubation with heparin led to increased activity of LPS and higher values of the pro-inflammatory cytokines tumor necrosis factor α (TNF-α) and interleukin 6 (IL-6). Accordingly, higher concentrations of A. baumannii, E. coli, K. pneumoniae, and P. aeruginosa were observed as well. These findings underscore the neutralizing effect of unfractionated heparin on blood-derived AMCs in vitro and may lead to alternative affinity techniques for isolating and characterizing novel AMCs with the potential for clinical translation.
Asunto(s)
Antiinfecciosos , Heparina , Heparina/farmacología , Escherichia coli , Antibacterianos/farmacología , Antiinfecciosos/farmacología , Endotoxinas/farmacología , Klebsiella pneumoniaeRESUMEN
AIMS: Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS: Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44â min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6â min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION: Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.
RESUMEN
Proton bunches with maximum energies between 12 and 22 MeV were emitted from submicrometer-thin plastic foils upon irradiation by laser pulses with peak intensity of 4×10^{20}W/cm^{2}. The images of the protons by a magnetic quadrupole doublet on a screen remained consistently larger by a factor of 10 compared to expectations drawn from the ultralow transverse emittance values reported for thick foil targets. Analytic estimates and particle-in-cell simulations attribute this drastically increased emittance to formerly excluded Coulomb collisions between charged particles. The presence of carbon ions and significant transparency likely play a decisive role. This observation is highly relevant because such thin, partially transparent foils are considered ideal for optimizing maximum proton energies.
RESUMEN
INTRODUCTION: When the kidneys or liver fail, toxic metabolites accumulate in the patient's blood, causing cardiovascular and neurotoxic complications and increased mortality. Conventional membrane-based extracorporeal blood purification procedures cannot remove these toxins efficiently. The aim of this in vitro study was to determine whether commercial hemoperfusion adsorbers are suitable for removing protein-bound retention solutes from human plasma and whole blood as well as to compare the removal to conventional hemodialysis. METHODS: For in vitro testing of the removal of protein-bound substances, whole blood and plasma were spiked with uremic retention solutes (homocysteine, hippuric acid, indoxyl sulfate, 3-carboxy-4-methyl-5-propyl-2-furanpropionic acid) and the toxins of liver failure (bilirubin, cholic acid, tryptophan, phenol). Subsequently, the protein binding of each retention solute was determined. The adsorption characteristics of the hemoperfusion adsorbers, Jafron HA and Biosky MG, both approved for the adsorption of protein-bound uremic retention solutes and Cytosorb, an adsorber recommended for adsorption of cytokines, were tested by incubating them in spiked whole blood or plasma for 1 h. Subsequently, the adsorption characteristics of the adsorbers were tested in a dynamic system. For this purpose, a 6-h in vitro hemoperfusion treatment was compared with an equally long in vitro hemodialysis treatment. RESULTS: Hippuric acid, homocysteine, indoxyl sulfate, and tryptophan were most effectively removed by hemodialysis. Bilirubin and cholic acid were removed best by hemoperfusion with Cytosorb. A treatment with Jafron HA and Biosky MG showed similar results for the adsorption of the tested retention solutes and were best for removing phenol. 3-Carboxy-4-methyl-5-propyl-2-furanpropionic acid could not be removed with any treatment method. DISCUSSION/CONCLUSION: A combination of hemodialysis with hemoperfusion seems promising to improve the removal of some toxic metabolites in extracorporeal therapies. However, some very strongly protein-bound metabolites cannot be removed adequately with the adsorbers tested.
Asunto(s)
Hipuratos , Toxinas Biológicas , Uremia , Humanos , Tóxinas Urémicas , Indicán , Triptófano/metabolismo , Diálisis Renal/efectos adversos , Unión Proteica , Fenoles , Bilirrubina , Ácido Cólico , Homocisteína/metabolismoRESUMEN
INTRODUCTION: Pulsed field ablation (PFA) represents a novel, nonthermal energy modality that can be applied for single-shot pulmonary vein isolation (PVI) in atrial fibrillation (AF). Comparative data with regard to deep sedation to established single-shot modalities such as cryoballoon (CB) ablation are scarce. The aim of this study was to compare a deep sedation protocol in patients receiving PVI with either PFA or CB. METHODS: Prospective, consecutive AF patients undergoing PVI with a pentaspline PFA catheter were compared to a retrospective CB-PVI cohort of the same timeframe. Study endpoints were the requirements of analgesics, cardiorespiratory stability, and sedation-associated complications. RESULTS: A total of 100 PVI patients were included (PFA n = 50, CB n = 50, mean age 66 ± 10.6, 61% male patients, 65% paroxysmal AF). Requirement of propofol, midazolam, and sufentanyl was significantly higher in the PFA group compared to CB [propofol 0.14 ± 0.04 mg/kg/min in PFA vs. 0.11 ± 0.04 mg/kg/min in CB (p = .001); midazolam 0.00086 ± 0.0004 mg/kg/min in PFA vs. 0.0006295 ± 0.0003 mg/kg/min in CB (p = .002) and sufentanyl 0.0013 ± 0.0007 µg/kg/min in PFA vs. 0.0008 ± 0.0004 µg/kg/min in CB (p < .0001)]. Sedation-associated complications did not differ between both groups (PFA n = 1/50 mild aspiration pneumonia, CB n = 0/50, p > .99). Nonsedation-associated complications (PFA: n = 2/50, 4%, CB: n = 1/50, 2%, p > .99) and procedure times (PFA 75 ± 31, CB 84 ± 32 min, p = .18) did not differ between groups. CONCLUSIONS: PFA is associated with higher sedation and especially analgesia requirements. However, the safety of deep sedation does not differ to CB ablation.
Asunto(s)
Analgesia , Fibrilación Atrial , Criocirugía , Propofol , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Midazolam/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodosRESUMEN
Enhanced weathering (EW) is an emerging carbon dioxide (CO2) removal technology that can contribute to climate change mitigation. This technology relies on accelerating the natural process of mineral weathering in soils by manipulating the abiotic variables that govern this process, in particular mineral grain size and exposure to acids dissolved in water. EW mainly aims at reducing atmospheric CO2 concentrations by enhancing inorganic carbon sequestration. Until now, knowledge of EW has been mainly gained through experiments that focused on the abiotic variables known for stimulating mineral weathering, thereby neglecting the potential influence of biotic components. While bacteria, fungi, and earthworms are known to increase mineral weathering rates, the use of soil organisms in the context of EW remains underexplored. This protocol describes the design and construction of an experimental setup developed to enhance mineral weathering rates through soil organisms while concurrently controlling abiotic conditions. The setup is designed to maximize weathering rates while maintaining soil organisms' activity. It consists of a large number of columns filled with rock powder and organic material, located in a climate chamber and with water applied via a downflow irrigation system. Columns are placed above a fridge containing jerrycans to collect the leachate. Representative results demonstrate that this setup is suitable to ensure the activity of soil organisms and quantify their effect on inorganic carbon sequestration. Challenges remain in minimizing leachate losses, ensuring homogeneous ventilation through the climate chamber, and avoiding flooding of the columns. With this setup, an innovative and promising approach is proposed to enhance mineral weathering rates through the activity of soil biota and disentangle the effect of biotic and abiotic factors as drivers of EW.
Asunto(s)
Dióxido de Carbono , Suelo , Dióxido de Carbono/análisis , Minerales , Grano Comestible/química , AguaRESUMEN
BACKGROUND: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. OBJECTIVE: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. METHODS: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. RESULTS: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. CONCLUSION: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.
RESUMEN
Alkalinity generation from rock weathering modulates Earth's climate at geological time scales. Although lithology is thought to dominantly control alkalinity generation globally, the role of other first-order controls appears elusive. Particularly challenging remains the discrimination of climatic and erosional influences. Based on global observations, here we uncover the role of erosion rate in governing riverine alkalinity, accompanied by areal proportion of carbonate, mean annual temperature, catchment area, and soil regolith thickness. We show that the weathering flux to the ocean will be significantly altered by climate warming as early as 2100, by up to 68% depending on the environmental conditions, constituting a sudden feedback of ocean CO2 sequestration to climate. Interestingly, warming under a low-emissions scenario will reduce terrestrial alkalinity flux from mid-latitudes (-1.6 t(bicarbonate) a-1 km-2) until the end of the century, resulting in a reduction in CO2 sequestration, but an increase (+0.5 t(bicarbonate) a-1 km-2) from mid-latitudes is likely under a high-emissions scenario, yielding an additional CO2 sink.
RESUMEN
Atrial fibrillation (AF) is the most common cardiac arrhythmia affecting millions of people worldwide and poses a significant burden to the health care system. AF screening of the general population or of a specific higher-risk population could not only lead to earlier detection of AF but also to a prompt initiation of an adequate therapy to prevent complications such as stroke or death and consecutively to a potential reduction of health care costs, especially in asymptomatic AF patients. To conduct screening programs, accessible new technology devices such as "wearables", smartwatches, and implantable event recorders provide an innovative solution. However, as data regarding screening are inconclusive, routine AF screening of the population is currently not recommended by the European Society of Cardiology. Recently published studies have indicated that anticoagulation and early rhythm control of asymptomatic AF could avoid occurrence of clinical endpoints. This article reports on the scientific results of the current literature as well as gaps of evidence and discusses possible treatment options of asymptomatic AF.
Asunto(s)
Fibrilación Atrial , Cardiología , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Prótesis e ImplantesRESUMEN
Background and Objectives: Selective pulmonary vein (PV) angiography has been established as the gold standard for PV visualization in cryoballoon (CB)-based pulmonary vein isolation (PVI). We sought to simplify this approach to reduce procedural complexity and radiation exposure. Materials and Methods: Patients with paroxysmal and recently diagnosed persistent AF undergoing CB-based PVI from January 2015 to December 2017 were retrospectively analyzed. Patients underwent either selective PV angiography or conventional left atrial (LA) angiography for PV visualization. Results: A total of 336 patients were analyzed. A total of 87 patients (26%) received PV angiography and 249 (74%) LA angiography. LA angiography required fewer cine-sequences for PV visualization, translating into a significant reduction in procedure duration, fluoroscopy time and dose area product. Additionally, less contrast medium was utilized. PV occlusion by the CB, CB temperature and time to isolation showed no significant differences. The number of CB applications and total application time (LA angiography: 1.4 ± 0.02 vs. PV Angiography: 1.6 ± 0.05; p < 0.0001; LA angiography: 297.9 ± 4.62 vs. PV-Angiography: 348.9 ± 11.03; p < 0.001, respectively) per vein were slightly but significantly higher in the PV angiography group. We observed no difference in late AF recurrence (24.7% LA angiography vs. 21.3% PV angiography; p = 0.2657). Conclusions: A simplified protocol, using LA angiography for PV visualization, entails a reduction in procedure time and radiation exposure while equally maintaining procedural efficiency and safety in both groups.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Estudios Retrospectivos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/métodos , RecurrenciaRESUMEN
In this article, typical characteristics of focal atrial tachycardias are described and a systematic approach regarding diagnostics and treatment options in the field of invasive cardiac electrophysiology (EP) is presented. Subjects of this article include the definition of focal atrial tachycardias, knowledge about localizing the origin of such, and guidance on how to approach an invasive EP study (e.g., administration of medication during the EP study to provoke tachycardias). Further, descriptions will be found on how to localize the origin of focal atrial tachycardias with the help of the 12-lead ECG and invasive three-dimensional mapping to successfully treat focal atrial tachycardias with catheter ablation.
Asunto(s)
Ablación por Catéter , Taquicardia Atrial Ectópica , Humanos , Ablación por Catéter/métodos , Taquicardia/cirugía , Electrocardiografía/métodosRESUMEN
INTRODUCTION: Recently, the wide-band dielectric mapping system Kodex-EPD was introduced. This study reports the first clinical experience using a novel system to guide pulmonary vein isolation (PVI) with radiofrequency (RF) ablation. METHODS AND RESULTS: The study included 20 consecutive patients undergoing de-novo PVI for symptomatic paroxysmal or persistent atrial fibrillation guided by Kodex-EPD. The primary efficacy endpoint was successful PVI. Secondary endpoints included procedural parameters and complications. In all 20 patients (mean age 68 ± 8 years, 12 male patients, paroxysmal fibrillation in 14/20 [70%] patients), PVI was successfully completed. One patient underwent additional cavo-tricuspid isthmus ablation for concomitant typical atrial flutter and one patient required additional ablation of a focal atrial tachycardia. A conventional three-dimensional image of the left atrium as well as the innovative endocardial panoramic view were used to guide catheter manipulation and ablation. Median procedure time was 115 [1st; 3rd quartile 93,75; 140] min and median total fluoroscopy time was 9.9 [9.7; 11.2] min, of which a median of 0.8 [0.6; 0.9] min was required to create left atrial maps. Complete left atrial imaging using Kodex-EPD was achieved within a median of 7.1 [5.7; 8.3] min. Median RF ablation time was 45.1 [34.6; 58.7] min. No major complications were observed. CONCLUSION: RF ablation PVI guided by Kodex-EPD seems safe and feasible. The system provides effective three-dimensional guidance for PVI.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Masculino , Persona de Mediana Edad , Anciano , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Resultado del TratamientoRESUMEN
INTRODUCTION: Catheter-ablation (CA) of consecutive left atrial tachycardias (LAT) can be challenging. Pulsed field ablation (PFA) yields a novel nonthermal CA technology for treatment of atrial fibrillation (AF). There is no data regarding PFA of LAT. This study sought to investigate PFA of consecutive LAT following prior CA of AF. METHODS: Consecutive patients with LAT underwent ultrahigh-density (UHDx) mapping. Subsequent to identification of the AT mechanism, PFA was performed at the assumed critical sites for LAT maintenance. Continuous ablation lines were performed if required and evaluated with pre- and post-PFA HDx-mapping. RESULTS: Fifteen patients (age 70 ± 10, male 73%) who underwent 3.6 ± 2 prior AF-CA procedures were included. The total mean procedure and fluoroscopy times were 141 ± 43 and 18 ± 10 min, respectively. All 19 of 19 (100%) LAT were successfully ablated with PFA. Two AT located at the right atria required RF-ablation. LAT were identified as localized reentry (n = 1) and macro-reentry LAT (n = 18) and targeted with PFA. All LAT terminated with PFA either to sinus rhythm (9/15) or a secondary AT (6/15 and subsequently to SR); 63% (12/19) terminated with the first PFA-application. All lines (13 roof, 11 anterior, 1 mitral) were blocked. LA-posterior-wall isolation (LAPWI) was successfully achieved when performed (10/10). AF/AT free survival was 80% (12/15) after 153 [88-207] days of follow-up. No procedure-related complications occurred. CONCLUSION: PFA of consecutive LAT is feasible and safe. Successful creation of ablation lines and LAPWI can be achieved in a short time. PFA may offer the opportunity for effective ablation of atrial arrhythmias beyond AF.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Taquicardia , Resultado del Tratamiento , Venas Pulmonares/cirugíaRESUMEN
We present the design and development of a variable-temperature high-speed scanning tunneling microscope (STM). The setup consists of a two-chamber ultra-high vacuum system, including a preparation and a main chamber. The preparation chamber is equipped with standard preparation tools for sample cleaning and film growth. The main chamber hosts the STM that is located within a continuous flow cryostat for counter-cooling during high-temperature measurements. The microscope body is compact, rigid, and highly symmetric to ensure vibrational stability and low thermal drift. We designed a hybrid scanner made of two independent tube piezos for slow and fast scanning, respectively. A commercial STM controller is used for slow scanning, while a high-speed Versa Module Eurocard bus system controls fast scanning. Here, we implement non-conventional spiral geometries for high-speed scanning, which consist of smooth sine and cosine signals created by an arbitrary waveform generator. The tip scans in a quasi-constant height mode, where the logarithm of the tunneling current signal can be regarded as roughly proportional to the surface topography. Scan control and data acquisition have been programmed in the experimental physics and industrial control system framework. With the spiral scans, we atomically resolved diffusion processes of oxygen atoms on the Ru(0001) surface and achieved a time resolution of 8.3 ms per frame at different temperatures. Variable-temperature measurements reveal an influence of the temperature on the oxygen diffusion rate.
RESUMEN
Preventing bacteria from adhering to material surfaces is an important technical problem and a major cause of infection. One of nature's defense strategies against bacterial colonization is based on the biohalogenation of signal substances that interfere with bacterial communication. Biohalogenation is catalyzed by haloperoxidases, a class of metal-dependent enzymes whose activity can be mimicked by ceria nanoparticles. Transparent CeO2/polycarbonate surfaces that prevent adhesion, proliferation, and spread of Pseudomonas aeruginosa PA14 were manufactured. Large amounts of monodisperse CeO2 nanoparticles were synthesized in segmented flow using a high-throughput microfluidic benchtop system using water/benzyl alcohol mixtures and oleylamine as capping agent. This reduced the reaction time for nanoceria by more than one order of magnitude compared to conventional batch methods. Ceria nanoparticles prepared by segmented flow showed high catalytic activity in halogenation reactions, which makes them highly efficient functional mimics of haloperoxidase enzymes. Haloperoxidases are used in nature by macroalgae to prevent formation of biofilms via halogenation of signaling compounds that interfere with bacterial cell-cell communication ("quorum sensing"). CeO2/polycarbonate nanocomposites were prepared by dip-coating plasma-treated polycarbonate panels in CeO2 dispersions. These showed a reduction in bacterial biofilm formation of up to 85% using P. aeruginosa PA14 as model organism. Besides biofilm formation, also the production of the virulence factor pyocyanin in is under control of the entire quorum sensing systems P. aeruginosa. CeO2/PC showed a decrease of up to 55% in pyocyanin production, whereas no effect on bacterial growth in liquid culture was observed. This indicates that CeO2 nanoparticles affect quorum sensing and inhibit biofilm formation in a non-biocidal manner.
Asunto(s)
Nanocompuestos , Nanopartículas , Antibacterianos/farmacología , Bacterias , Biopelículas , Pseudomonas aeruginosa , Piocianina , Percepción de Quorum , Factores de VirulenciaRESUMEN
BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrofisiología Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Atrial fibrillation is the most common type of cardiac arrhythmia; the lifetime risk for a 55-year-old person to develop atrial fibrillation is 37%. In recent years, years there have been various distinct changes in the clinical management of AF. METHODS: This review is based on a selective search for literature on the treatment of AF and the prevention of thromboembolic complications. The updated guideline of the European Society of Cardiology (ESC) for the diagnosis and treatment of AF was also taken into consideration. RESULTS: The main components of AF management are the comprehensive treatment of risk factors and concomitant diseases, as well as the prevention of thromboembolic complications, usually with non-vitamin-K-dependent oral anticoagulants or vitamin K antagonists, according to individual risk stratification. Beyond this, either rate or rhythm control are viable treatment concepts. Symptomatic patients in whom reversible causes have been ruled out should be offered rhythm-control therapy early in their course. In patients with risk factors and/or heart failure, an early rhythm control strategy has been found to be beneficial. As antiarrhythmic drugs often prove to be ineffective over the long term, catheter ablation is now becoming increasingly important in AF management. CONCLUSION: The clinical management of atrial fibrillation consists of a multimodal approach with risk stratification, lifestyle modification, prevention of thromboembolism, and, if possible, early rhythm control therapy.
RESUMEN
Anthropogenic perturbations are increasing uncertainties in estimating CO2 emissions via air-water CO2 flux (FCO2) from large rivers of the Indian subcontinent. This study aimed to provide an improved estimate of the total FCO2 from the subcontinental rivers by combining calculations of the partial pressure of CO2 (pCO2) in eight major rivers with new measurements in the Ganges and Godavari. The average pCO2 in the two newly surveyed rivers, including tributaries, wastewater drains, and impoundments, were 3-6 times greater than the previously reported values. In some highly polluted urban tributaries and middle reaches of the Ganges that drain metropolitan areas, the measured pCO2 exceeded 20,000 µatm, ~40 times the background levels of the headwaters originating in the carbonate-rich Himalayas. The high pCO2 above 28,000 µatm in the lower reach of the Godavari was seven times the moderate levels of pCO2 in the headwaters of the volcanic Deccan Traps, indicating enhanced CO2 production in soils and anthropogenic sources under favorable conditions for organic matter degradation. Across the northern rivers, pCO2 exhibited a significant negative relationship with dissolved oxygen, but a positive relationship with inorganic N or P concentrations. The strong influence of water pollution on riverine pCO2 suggests that CO2 emissions from hypoxic, eutrophic reaches can greatly exceed phytoplanktonic CO2 uptake. Spatially resolved pCO2 data, combined with three gas transfer velocity estimates, provided a higher range of FCO2 from the subcontinental rivers (100.9-130.2 Tg CO2 yr-1) than the previous estimates (7.5-61.2 Tg CO2 yr-1). The revised estimates representing 2-5% of the global riverine FCO2 illustrate the importance of the Indian subcontinental rivers under increasing anthropogenic pressures in constraining global inland waters FCO2.
Asunto(s)
Dióxido de Carbono , Monitoreo del Ambiente , Dióxido de Carbono/análisis , Presión Parcial , Ríos , Aguas ResidualesRESUMEN
A number of negative emission technologies (NETs) have been proposed to actively remove CO2 from the atmosphere, with enhanced silicate weathering (ESW) as a relatively new NET with considerable climate change mitigation potential. Models calibrated to ESW rates in lab experiments estimate the global potential for inorganic carbon sequestration by ESW at about 0.5-5 Gt CO2 year-1 , suggesting ESW could be an important component of the future NETs mix. In real soils, however, weathering rates may differ strongly from lab conditions. Research on natural weathering has shown that biota such as plants, microbes, and macro-invertebrates can strongly affect weathering rates, but biotic effects were excluded from most ESW lab assessments. Moreover, ESW may alter soil organic carbon sequestration and greenhouse gas emissions by influencing physicochemical and biological processes, which holds the potential to perpetuate even larger negative emissions. Here, we argue that it is likely that the climate change mitigation effect of ESW will be governed by biological processes, emphasizing the need to put these processes on the agenda of this emerging research field.