Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
EJNMMI Phys ; 10(1): 34, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37261547

RESUMEN

BACKGROUND: Image optimization is a key step in clinical nuclear medicine, and phantoms play an essential role in this process. However, most phantoms do not accurately reflect the complexity of human anatomy, and this presents a particular challenge when imaging endocrine glands to detect small (often subcentimeter) tumors. To address this, we developed a novel phantom for optimization of positron emission tomography (PET) imaging of the human pituitary gland. Using radioactive 3D printing, phantoms were created which mimicked the distribution of 11C-methionine in normal pituitary tissue and in a small tumor embedded in the gland (i.e., with no inactive boundary, thereby reproducing the in vivo situation). In addition, an anatomical phantom, replicating key surrounding structures [based on computed tomography (CT) images from an actual patient], was created using material extrusion 3D printing with specialized filaments that approximated the attenuation properties of bone and soft tissue. RESULTS: The phantom enabled us to replicate pituitary glands harboring tumors of varying sizes (2, 4 and 6 mm diameters) and differing radioactive concentrations (2 ×, 5 × and 8 × the normal gland). The anatomical phantom successfully approximated the attenuation properties of surrounding bone and soft tissue. Two iterative reconstruction algorithms [ordered subset expectation maximization (OSEM); Bayesian penalized likelihood (BPL)] with a range of reconstruction parameters (e.g., 3, 5, 7 and 9 OSEM iterations with 24 subsets; BPL regularization parameter (ß) from 50 to 1000) were tested. Images were analyzed quantitatively and qualitatively by eight expert readers. Quantitatively, signal was the highest using BPL with ß = 50; noise was the lowest using BPL with ß = 1000; contrast was the highest using BPL with ß = 100. The qualitative review found that accuracy and confidence were the highest when using BPL with ß = 400. CONCLUSIONS: The development of a bespoke phantom has allowed the identification of optimal parameters for molecular pituitary imaging: BPL reconstruction with TOF, PSF correction and a ß value of 400; in addition, for small (< 4 mm) tumors with low contrast (2:1 or 5:1), sensitivity may be improved using a ß value of 100. Together, these findings should increase tumor detection and confidence in reporting scans.

2.
EJNMMI Res ; 12(1): 26, 2022 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-35524902

RESUMEN

BACKGROUND: Pituitary adenomas (PA) affect ~ 1:1200 of the population and can cause a wide range of symptoms due to hormone over-secretion, loss of normal pituitary gland function and/or compression of visual pathways, resulting in significantly impaired quality of life. Surgery is potentially curative if the location of the adenoma can be determined. However, standard structural (anatomical) imaging, in the form of MRI, is unable to locate all tumors, especially microadenomas (< 1 cm diameter). In such cases, functional imaging [11C-methionine PET/CT (Met-PET)] can facilitate tumor detection, although may be inconclusive when the adenoma is less metabolically active. We, therefore, explored whether subtraction imaging, comparing findings between two Met-PET scans with medical therapy-induced suppression of tumor activity in the intervening period, could increase confidence in adenoma localization. In addition, we assessed whether normalization to a reference region improved consistency of pituitary gland signal in healthy volunteers who underwent two Met-PET scans without medical suppression. RESULTS: We found that the mean percentage differences in maximum pituitary uptake between two Met-PET scans in healthy volunteers were 2.4% for (SUVr) [cerebellum], 8.8% for SUVr [pons], 5.2% for SUVr [gray matter] and 23.1% for the SUVbw [no region]. Laterality, as measured by contrast-noise ratio (CNR), indicated the correct location of the adenoma in all three image types with mean CNR values of 6.2, 8.1 and 11.1 for SUVbw, SUVbwSub and SUVrSub [cerebellum], respectively. Subtraction imaging improved CNR in 60% and 100% of patients when using images generated from SUVbw [no region] and SUVr [cerebellum] scans compared to standard clinical SUVbw imaging. CONCLUSIONS: Met-PET scans should be normalized to the cerebellum to minimize the effects of physiological variation in pituitary gland uptake of 11C-methionine, especially when comparing serial imaging. Subtraction imaging following endocrine suppression of tumor function improved lateralization of PA when compared with single time point clinical Met-PET but, importantly, only if the images were normalized to the cerebellum prior to subtraction.

3.
World J Nucl Med ; 20(2): 139-144, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34321965

RESUMEN

A retrospective analysis was performed of epidemiological data assessing the survival of patients who had received radium-223 for castrate-resistant metastatic prostate cancer treated at a regional tertiary referral center over a 5-year period. The patients' age, date of first treatment, and the number of cycles of radium-223 given were obtained from the patients' electronic patient record (EPR). Data on the date of death were provided by national death registrations which update the EPR via a unique national health service number. A total of 187 patients (mean age on the date of first treatment: 73 years; range: 56-93) were treated from April 1, 2014, to June 30, 2019. The median overall survival of the 119 patients (71%) who had died by December 31, 2019, was 15 months. There was no significant age difference between those who had died and survivors (72 vs. 74 years). On a further analysis, it was found that the median overall survival of the 107 patients who had received all the six cycles of radium-223 was 31 months, significantly longer than the median overall survival of only 6 months for those eighty patients who had received less than the full course of six cycles of radium-223 (P = 0.001). Of those who received all the six cycles of treatment, 58 patients had died (58%) and the 1-year survival was 87%. This was compared to the group of patients receiving <6 cycles of radium-223 where 61 patients (76%) had died and the 1-year survival was 30%. Therefore, the hazard ratio of dying before 1 year if the patient did not receive all the six cycles of treatment was 2.9. Where the reason for stopping treatment was recorded on the EPR the most common cause for the cessation of treatment was because of the side effects caused by the treatment itself. Other causes were hospitalization with comorbidities, disease progression, or patient choice. Given the survival advantage of receiving the full course of all the six cycles of treatment, this should be administered if possible and the patients should be managed in such a way as to allow the complete treatment course to be given.

4.
EJNMMI Phys ; 8(1): 38, 2021 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-33909154

RESUMEN

PURPOSE: Phantoms are routinely used in molecular imaging to assess scanner performance. However, traditional phantoms with fillable shapes do not replicate human anatomy. 3D-printed phantoms have overcome this by creating phantoms which replicate human anatomy which can be filled with radioactive material. The problem with these is that small objects suffer to a greater extent than larger objects from the effects of inactive walls, and therefore, phantoms without these are desirable. The purpose of this study was to explore the feasibility of creating resin-based 3D-printed phantoms using 18F. METHODS: Radioactive resin was created using an emulsion of printer resin and 18F-FDG. A series of test objects were printed including twenty identical cylinders, ten spheres with increasing diameters (2 to 20 mm), and a double helix. Radioactive concentration uniformity, printing accuracy and the amount of leaching were assessed. RESULTS: Creating radioactive resin was simple and effective. The radioactive concentration was uniform among identical objects; the CoV of the signal was 0.7% using a gamma counter. The printed cylinders and spheres were found to be within 4% of the model dimensions. A double helix was successfully printed as a test for the printer and appeared as expected on the PET scanner. The amount of radioactivity leached into the water was measurable (0.72%) but not visible above background on the imaging. CONCLUSIONS: Creating an 18F radioactive resin emulsion is a simple and effective way to create accurate and complex phantoms without inactive walls. This technique could be used to print clinically realistic phantoms. However, they are single use and cannot be made hollow without an exit hole. Also, there is a small amount of leaching of the radioactivity to take into consideration.

5.
Thorax ; 75(11): 1020-1023, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32887739

RESUMEN

Neutrophils play an important role in the lung tumour microenvironment. We hypothesised that radiolabelled neutrophils coupled to single-photon emission CT (SPECT) may non-invasively quantify neutrophil uptake in tumours from patients with non-small cell lung cancer. We demonstrated increased uptake of radiolabelled neutrophils from the blood into tumours compared with non-specific uptake using radiolabelled transferrin. Moreover, indium-111-neutrophil activity in the tumour biopsies also correlated with myeloperoxidase (MPO)-positive neutrophils. Our data support the utility of imaging with In-111-labelled neutrophils and SPECT-CT to quantify neutrophil uptake in lung cancer.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Neutrófilos , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Biopsia , Femenino , Humanos , Radioisótopos de Indio , Neoplasias Pulmonares/patología , Masculino , Estadificación de Neoplasias
6.
Biosci Rep ; 38(4)2018 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-29700216

RESUMEN

The study's aim was to image severe alcoholic hepatitis (SAH) using 111In-labelled leucocytes with two objectives in mind: firstly for non-invasive diagnosis and secondly to provide a platform for experimental therapies aiming to inhibit intrahepatic neutrophil migration. 111In-leucocyte scintigraphy was performed 30 min and 24 h post-injection in 19 patients with SAH, 14 abstinent patients with alcohol-related cirrhosis and 11 normal controls. Eleven with SAH and seven with cirrhosis also had 99mTc-nanocolloid scintigraphy. Change in hepatic 111In radioactivity was expressed as decay-corrected 24 h:30 min count ratio and, in SAH, compared with histological grading of steatohepatitis and expression of granulocyte marker, CD15. Hepatic microautoradiography on biopsy specimens obtained 24 h post-injection of 111In-leucocytes was performed in one patient. Median 24 h:30 min hepatic 111In activity ratio was higher in SAH (2.5 (interquartile range (IQR): 1.7-4.0) compared with cirrhotics and normal controls (1.0 (0.8-1.1) and 0.8 (0.7-0.9) respectively, P<0.0001). In SAH, it correlated with CD15 expression (r = 0.62, P=0.023) and was higher in marked compared with mild/moderate steatohepatitis (4.0 (3.0-4.6) compared with 1.8 (1.5-2.6), P=0.006). Hepatic-to-splenic 99mTc count rate ratio was reduced in SAH (0.5 (0.4-1.4)) compared with cirrhotics (2.3( 0.6-3.0)) and three historic normal controls (4.2 (3.8-5.0); P=0.003), consistent with impaired hepatic reticuloendothelial function. Scintigraphic findings in SAH included prominent lung radioactivity at 30 min, likely the result of neutrophil primimg. Microautoradiography demonstrated cell-associated 111In in areas of parenchymal neutrophil infiltration. In conclusion, 111In-leucocyte scintigraphy can non-invasively diagnose SAH and could provide a platform for evaluation of novel treatments aiming to inhibit intrahepatic neutrophil migration.


Asunto(s)
Hepatitis Alcohólica/diagnóstico por imagen , Hígado/diagnóstico por imagen , Infiltración Neutrófila , Neutrófilos/patología , Enfermedad Aguda , Adulto , Movimiento Celular , Femenino , Hepatitis Alcohólica/inmunología , Hepatitis Alcohólica/patología , Humanos , Radioisótopos de Indio/análisis , Hígado/inmunología , Hígado/patología , Masculino , Persona de Mediana Edad , Neutrófilos/inmunología , Cintigrafía
7.
Nucl Med Commun ; 38(6): 471-479, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28394818

RESUMEN

OBJECTIVE: The objective of this study was to quantify any improvement with the GE 'Sharp IR' point-spread function (PSF) reconstruction algorithm in addition to ordered subsets expectation maximum (OSEM) and time-of-flight (TOF) reconstruction algorithms and establish the optimum parameters to be used in clinical studies. MATERIALS AND METHODS: We conducted a range of experiments using the National Electrical Manufacturers Association image quality phantom filled with a 4 : 1 signal-to-background ratio. We scanned the phantom using the GE Discovery 690 PET/CT scanner. We varied iteration number and Gaussian filtration. Results were compared for OSEM, OSEM+TOF and OSEM+TOF+PSF reconstructions. A sample of 15 whole-body fluorine-18-fluorodeoxyglucose were reconstructed with OSEM+TOF and OSEM+TOF+PSF using a selection of optimum reconstruction parameters determined in phantom studies. Clinicians qualitatively ranked their preferred images to choose optimum parameters. RESULTS: The addition of PSF improved signal-to-noise ratios (SNRs), contrast, hot contrast recovery coefficients and noise over OSEM and OSEM+TOF reconstruction algorithms. SNRs were the highest at two iterations and with 0 or 2 mm filters with OSEM+TOF+PSF reconstruction in all phantom studies. Clinicians generally favoured OSEM+TOF+PSF reconstruction with three iterations and a 2 mm filter. CONCLUSION: PSF reconstruction significantly improved image quality for both clinical and phantom studies. We recommended the optimum reconstruction parameters using three iterations, 24 subsets and a 2 mm filter, which improved SNRs by up to 28.8% for small lesions (P<0.05).


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Control de Calidad
8.
Physiol Rep ; 4(17)2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27613822

RESUMEN

Although granulocyte dysfunction is known to occur in cirrhosis, in vivo studies of granulocyte lifespan have not previously been performed. The normal circulating granulocyte survival half-time (G - t½), determined using indium-111 ((111)In)-radiolabeled granulocytes, is ~7 h. In this pilot study, we aimed to measure the in vivo G - t½ in compensated alcohol-related cirrhosis. Sequential venous blood samples were obtained in abstinent subjects with alcohol-related cirrhosis over 24 h post injection (PI) of minimally manipulated (111)In-radiolabeled autologous mixed leukocytes. Purified granulocytes were isolated from each sample using a magnetic microbead-antibody technique positively selecting for the marker CD15. Granulocyte-associated radioactivity was expressed relative to peak activity, plotted over time, and G - t½ estimated from data up to 12 h PI This was compared with normal neutrophil half-time (N - t½), determined using a similar method specifically selecting neutrophils in healthy controls at a collaborating center. Seven patients with cirrhosis (six male, aged 57.8 ± 9.4 years, all Child-Pugh class A) and seven normal controls (three male, 64.4 ± 5.6 years) were studied. Peripheral blood neutrophil counts were similar in both groups (4.6 (3.5 - 5.5) × 10(9)/L vs. 2.8 (2.7 - 4.4) × 10(9)/L, respectively, P = 0.277). G - t½ in cirrhosis was significantly lower than N - t½ in controls (2.7 ± 0.5 h vs. 4.4 ± 1.0 h, P = 0.007). Transient rises in granulocyte and neutrophil-associated activities occurred in four patients from each group, typically earlier in cirrhosis (4-6 h PI) than in controls (8-10 h), suggesting recirculation of radiolabeled cells released from an unidentified focus. Reduced in vivo granulocyte survival in compensated alcohol-related cirrhosis is a novel finding and potentially another mechanism for immune dysfunction in chronic liver disease. Larger studies are needed to corroborate these pilot data and assess intravascular neutrophil residency in other disease etiologies.


Asunto(s)
Granulocitos/patología , Cirrosis Hepática Alcohólica/sangre , Anciano , Femenino , Granulocitos/inmunología , Granulocitos/metabolismo , Humanos , Leucocitos/inmunología , Leucocitos/metabolismo , Leucocitos/patología , Cirrosis Hepática Alcohólica/inmunología , Masculino , Persona de Mediana Edad , Neutrófilos/inmunología , Neutrófilos/metabolismo , Neutrófilos/patología , Proyectos Piloto
9.
Eur J Endocrinol ; 175(5): 485-498, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27562400

RESUMEN

OBJECTIVE: To determine if functional imaging using 11C-methionine positron emission tomography co-registered with 3D gradient echo MRI (Met-PET/MRI), can identify sites of residual active tumour in treated acromegaly, and discriminate these from post-treatment change, to allow further targeted treatment. DESIGN/METHODS: Twenty-six patients with persistent acromegaly after previous treatment, in whom MRI appearances were considered indeterminate, were referred to our centre for further evaluation over a 4.5-year period. Met-PET/MRI was performed in each case, and findings were used to decide regarding adjunctive therapy. Four patients with clinical and biochemical remission after transsphenoidal surgery (TSS), but in whom residual tumour was suspected on post-operative MRI, were also studied. RESULTS: Met-PET/MRI demonstrated tracer uptake only within the normal gland in the four patients who had achieved complete remission after primary surgery. In contrast, in 26 patients with active acromegaly, Met-PET/MRI localised sites of abnormal tracer uptake in all but one case. Based on these findings, fourteen subjects underwent endoscopic TSS, leading to a marked improvement in (n = 7), or complete resolution of (n = 7), residual acromegaly. One patient received stereotactic radiosurgery and two patients with cavernous sinus invasion were treated with image-guided fractionated radiotherapy, with good disease control. Three subjects await further intervention. Five patients chose to receive adjunctive medical therapy. Only one patient developed additional pituitary deficits after Met-PET/MRI-guided TSS. CONCLUSIONS: In patients with persistent acromegaly after primary therapy, Met-PET/MRI can help identify the site(s) of residual pituitary adenoma when MRI appearances are inconclusive and direct further targeted intervention (surgery or radiotherapy).

10.
Methods Mol Biol ; 1178: 165-76, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24986616

RESUMEN

Radiolabelled leukocyte scans are widely used in nuclear medicine to locate sites of infection and inflammation. Radiolabelling of leukocyte subpopulations can also yield valuable information on cell trafficking and kinetics in vivo, but care must be taken to minimize inadvertent cell activation ex vivo. Here, we describe the use of autologous indium(111)-labelled eosinophils to measure eosinophil intravascular life-span and monitor their distribution and fate using gamma camera imaging in healthy non-atopic individuals.


Asunto(s)
Eosinófilos/citología , Eosinófilos/metabolismo , Voluntarios Sanos , Humanos , Radioisótopos de Indio , Cinética
11.
Blood ; 120(19): 4068-71, 2012 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-22993388

RESUMEN

Eosinophils are the major cellular effectors of allergic inflammation and represent an important therapeutic target. Although the genesis and activation of eosinophils have been extensively explored, little is known about their intravascular kinetics or physiological fate. This study was designed to determine the intravascular life span of eosinophils, their partitioning between circulating and marginated pools, and sites of disposal in healthy persons. Using autologous, minimally manipulated 111-Indium-labeled leukocytes with blood sampling, we measured the eosinophil intravascular residence time as 25.2 hours (compared with 10.3 hours for neutrophils) and demonstrated a substantial marginated eosinophil pool. γ camera imaging studies using purified eosinophils demonstrated initial retention in the lungs, with early redistribution to the liver and spleen, and evidence of recirculation from a hepatic pool. This work provides the first in vivo measurements of eosinophil kinetics in healthy volunteers and shows that 111-Indium-labeled eosinophils can be used to monitor the fate of eosinophils noninvasively.


Asunto(s)
Rastreo Celular/métodos , Eosinófilos/citología , Radioisótopos de Indio/administración & dosificación , Adulto , Eosinófilos/fisiología , Femenino , Granulocitos/citología , Humanos , Radioisótopos de Indio/metabolismo , Cinética , Masculino , Coloración y Etiquetado , Factores de Tiempo , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA