Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Klin Monbl Augenheilkd ; 235(6): 725-729, 2018 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-28086253

RESUMEN

Silicone oil is an intraocular tamponade that is essential for the treatment of complicated retinal detachment. As a long-term tamponade, it improves retinal reattachment and visual outcome. Unexpectedly, surgery with silicone oil tamponade may result in irreversible visual loss of unknown origin. In this report, we provide a general overview of unexplained visual loss after surgery with silicone oil. The frequency of such reports has increased continuously in recent years. The German Retina Society - supported by Retinanet (http://retina-net.uni-koeln.de) - has initiated data collection to gather information about such cases, in cooperation with Cologne University Eye Hospital. Ophthalmologists can provide data about cases of unexplained visual loss anonymously via the "Cologne Clinical Trials Centre" or via augenklinik-silikonoel@uk-koeln.de.


Asunto(s)
Desprendimiento de Retina , Aceites de Silicona , Ceguera , Humanos , Retina , Aceites de Silicona/efectos adversos , Agudeza Visual , Vitrectomía
2.
Klin Monbl Augenheilkd ; 231(10): 980-7, 2014 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-25333233

RESUMEN

BACKGROUND: Some patients with esotropic Duane's retraction syndrome (type 1) adopt a head turn to gain binocular vision. For some patients recession of the ipsilateral medial rectus muscle is not sufficient to eliminate head turn and squint angle. Surgery with tendon elongation allows the correction of larger angles and maintains a sufficient arc of contact. We report our results and experience. METHODS: We retrospectively reviewed the medical records of 10 patients with unilateral, esotropic Duane syndrome type 1 who had tendon elongation with bovine pericardium to correct a head turn or squint angle. Two patients had primary surgery with tendon elongation due to preoperative excessive angles, eight patients had tendon elongations as secondary procedures. Nine of the patients had their follow-up examination at least six weeks after surgery. RESULTS: The median preoperative angle of squint in primary position was + 27.5 pdpt, the median postoperative angle + 0 pdpt. The median dose effect relation for secondary interventions was 2.4 pdpt reduction of squint angle/mm surgery, for one patient with primary surgery and long-term follow-up 2.75 pdpt/mm. The median, preoperative head turn of seven patients with preoperative binocular functions was 20°. Postoperatively, six patients with long-term follow-up showed a median head turn of 0°. The median dose-effect relation was 3.3° reduction of head turn/mm surgery. All nine patients with long-term follow-up had a maximal head turn of 10°, six of the patients had no persisting head turn. Binocular functions were stable or better than preoperatively. CONCLUSIONS: For patients with retraction syndrome type 1, tendon elongation of the medial rectus muscle using Tutopatch® is a good option for secondary interventions or excessive preoperative squint angle or head turn.


Asunto(s)
Síndrome de Retracción de Duane/diagnóstico , Síndrome de Retracción de Duane/cirugía , Procedimientos Quirúrgicos Oftalmológicos/métodos , Pericardio/trasplante , Procedimientos de Cirugía Plástica/métodos , Tenotomía/métodos , Adolescente , Adulto , Anciano , Animales , Bovinos , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Oftalmológicos/instrumentación , Procedimientos de Cirugía Plástica/instrumentación , Estudios Retrospectivos , Tenotomía/instrumentación , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...