Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 95(17): 6980-6988, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37070980

RESUMEN

The mammalian brain contains ∼20,000 distinct lipid species that contribute to its structural organization and function. The lipid profiles of cells change in response to a variety of cellular signals and environmental conditions that result in modulation of cell function through alteration of phenotype. The limited sample material combined with the vast chemical diversity of lipids makes comprehensive lipid profiling of individual cells challenging. Here, we leverage the resolving power of a 21 T Fourier-transform ion cyclotron resonance (FTICR) mass spectrometer for chemical characterization of individual hippocampal cells at ultrahigh mass resolution. The accuracy of the acquired data allowed differentiation of freshly isolated and cultured hippocampal cell populations, as well as finding differences in lipids between the soma and neuronal processes of the same cell. Differences in lipids include TG 42:2 observed solely in the cell bodies and SM 34:1;O2 found only in the cellular processes. The work represents the first mammalian single cells analyzed at ultrahigh resolution and is an advance in the performance of mass spectrometry (MS) for single-cell research.


Asunto(s)
Ciclotrones , Lípidos , Animales , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Análisis de Fourier , Mamíferos
2.
J Biol Chem ; 299(1): 102768, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36470426

RESUMEN

The KRAS gene is one of the most frequently mutated oncogenes in human cancer and gives rise to two isoforms, KRAS4A and KRAS4B. KRAS post-translational modifications (PTMs) have the potential to influence downstream signaling. However, the relationship between KRAS PTMs and oncogenic mutations remains unclear, and the extent of isoform-specific modification is unknown. Here, we present the first top-down proteomics study evaluating both KRAS4A and KRAS4B, resulting in 39 completely characterized proteoforms across colorectal cancer cell lines and primary tumor samples. We determined which KRAS PTMs are present, along with their relative abundance, and that proteoforms of KRAS4A versus KRAS4B are differentially modified. Moreover, we identified a subset of KRAS4B proteoforms lacking the C185 residue and associated C-terminal PTMs. By confocal microscopy, we confirmed that this truncated GFP-KRAS4BC185∗ proteoform is unable to associate with the plasma membrane, resulting in a decrease in mitogen-activated protein kinase signaling pathway activation. Collectively, our study provides a reference set of functionally distinct KRAS proteoforms and the colorectal cancer contexts in which they are present.


Asunto(s)
Neoplasias Colorrectales , Proteínas Quinasas Activadas por Mitógenos , Proteínas Proto-Oncogénicas p21(ras) , Transducción de Señal , Humanos , Neoplasias Colorrectales/genética , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Procesamiento Proteico-Postraduccional , Proteínas Proto-Oncogénicas p21(ras)/genética , Proteínas Proto-Oncogénicas p21(ras)/metabolismo , Línea Celular Tumoral , Proteómica , Proteínas Quinasas Activadas por Mitógenos/metabolismo
3.
Science ; 375(6579): 411-418, 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-35084980

RESUMEN

Human biology is tightly linked to proteins, yet most measurements do not precisely determine alternatively spliced sequences or posttranslational modifications. Here, we present the primary structures of ~30,000 unique proteoforms, nearly 10 times more than in previous studies, expressed from 1690 human genes across 21 cell types and plasma from human blood and bone marrow. The results, compiled in the Blood Proteoform Atlas (BPA), indicate that proteoforms better describe protein-level biology and are more specific indicators of differentiation than their corresponding proteins, which are more broadly expressed across cell types. We demonstrate the potential for clinical application, by interrogating the BPA in the context of liver transplantation and identifying cell and proteoform signatures that distinguish normal graft function from acute rejection and other causes of graft dysfunction.


Asunto(s)
Células Sanguíneas/química , Proteínas Sanguíneas/química , Células de la Médula Ósea/química , Bases de Datos de Proteínas , Isoformas de Proteínas/química , Proteoma/química , Empalme Alternativo , Linfocitos B/química , Proteínas Sanguíneas/genética , Linaje de la Célula , Humanos , Leucocitos Mononucleares/química , Trasplante de Hígado , Plasma/química , Isoformas de Proteínas/genética , Procesamiento Proteico-Postraduccional , Proteómica , Linfocitos T/química
4.
Anal Chem ; 93(41): 13749-13754, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34623794

RESUMEN

High magnetic field Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry provides the highest mass resolving power and mass measurement accuracy for detailed characterization of complex chemical mixtures. Here, we report the coupling of online liquid chromatography of complex mixtures with a 21 tesla FT-ICR mass spectrometer. The high magnetic field enables large ion populations to be analyzed for each spectrum for a high dynamic range, with 3.2 million mass resolving power at m/z 400 (6.2 s transient duration) or 1.6 million (3.1 s transient duration) while maintaining high mass accuracy for molecular formula assignment (root-mean-square assignment error < 0.150 ppm). Thousands of unique elemental compositions are assigned per mass spectrum, which can be grouped by the heteroatom class, double bond equivalents (the number of rings and double bonds to carbon), and carbon number. Figures of merit are discussed, as well as characterization of an Arabian heavy vacuum gas oil in terms of the ring number, compound class, double bond equivalents, and ion type. Consideration of elemental composition and retention order provides additional structural information.


Asunto(s)
Ciclotrones , Petróleo , Cromatografía Liquida , Análisis de Fourier , Espectrometría de Masas , Petróleo/análisis
5.
Anal Chem ; 93(26): 9119-9128, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34165955

RESUMEN

Proton-transfer reactions (PTRs) have emerged as a powerful tool for the study of intact proteins. When coupled with m/z-selective kinetic excitation, such as parallel ion parking (PIP), one can exert exquisite control over rates of reaction with a high degree of specificity. This allows one to "concentrate", in the gas phase, nearly all the signals from an intact protein charge state envelope into a single charge state, improving the signal-to-noise ratio (S/N) by 10× or more. While this approach has been previously reported, here we show that implementing these technologies on a 21 T FT-ICR MS provides a tremendous advantage for intact protein analysis. Advanced strategies for performing PTR with PIP were developed to complement this unique instrument, including subjecting all analyte ions entering the mass spectrometer to PTR and PIP. This experiment, which we call "PTR-MS1-PIP", generates a pseudo-MS1 spectrum derived from ions that are exposed to the PTR reagent and PIP waveforms but have not undergone any prior true mass filtering or ion isolation. The result is an extremely rapid and significant improvement in the spectral S/N of intact proteins. This permits the observation of many more proteoforms and reduces ion injection periods for subsequent tandem mass spectrometry characterization. Additionally, the product ion parking waveform has been optimized to enhance the PTR rate without compromise to the parking efficiency. We demonstrate that this process, called "rapid park", can improve reaction rates by 5-10× and explore critical factors discovered to influence this process. Finally, we demonstrate how coupling PTR-MS1 and rapid park provides a 10-fold reduction in ion injection time, improving the rate of tandem MS sequencing.


Asunto(s)
Proteínas , Protones , Indicadores y Reactivos , Iones , Espectrometría de Masas en Tándem
6.
Environ Sci Technol ; 54(16): 9968-9979, 2020 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-32806909

RESUMEN

Asphaltenes are high-boiling and recalcitrant compounds that are generally minor components of crude oil (∼0.1-15.0 wt %) but dominate the composition of heavily weathered spilled petroleum. These solid residues exhibit a high structural complexity, comprised of polycyclic aromatic hydrocarbons (PAHs) that are a mixture of single-core (island) and multicore (archipelago) structural motifs. The mass fraction of each motif is sample-dependent. Thus, knowledge of a potential structural dependence (single- versus multicore) on the production of water-soluble species from asphaltene samples is key to understanding the contribution of photochemically generated dissolved organic matter from oil spills. In this work, asphaltene samples with enriched mass fractions of either island (single-core) or archipelago (multicore) structural motifs are photo-oxidized on artificial seawater by the use of a solar simulator. Molecular characterization of oil- and water-soluble photoproducts, conducted by Fourier transform ion cyclotron resonance mass spectrometry, reveals that island motifs exhibit very limited production of water-soluble species, and their oil-soluble products reflect the molecular composition of the starting material. Conversely, archipelago motifs yield a water-soluble compositional continuum of Ox, SxOy, and NxOy containing hydrocarbons species that exhibit the typical molecular fingerprint of dissolved organic matter (DOM). The lower carbon number and aromaticity of the archipelago-derived asphaltene photoproducts suggest the occurrence of photofragmentation (or photolysis) reactions. To investigate the possibility of the opposite reaction (photopolymerization), the photo-oxidation of small PAHs isolated from a low-boiling petroleum distillation cut was also performed. It yielded water-soluble compounds with carbon number and aromaticity up to 2-fold higher than the starting material, strongly suggesting that polymerization (addition reactions) occurs. Collectively, the results indicate that the presence of archipelago motifs and the occurrence of cracking/polymerization reactions are central in the production of dissolved organic matter from fossil fuels.


Asunto(s)
Contaminación por Petróleo , Petróleo , Hidrocarburos Policíclicos Aromáticos , Contaminantes Químicos del Agua , Estructura Molecular , Petróleo/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Agua , Contaminantes Químicos del Agua/análisis
7.
Anal Chem ; 92(18): 12193-12200, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32812743

RESUMEN

Fourier transform mass spectrometers routinely provide high mass resolution, mass measurement accuracy, and mass spectral dynamic range. In this work, we utilize 21 T Fourier transform ion cyclotron resonance (FT-ICR) to analyze product ions derived from the application of multiple dissociation techniques and/or multiple precursor ions within a single transient acquisition. This ion loading technique, which we call, "chimeric ion loading", saves valuable acquisition time, decreases sample consumption, and improves top-down protein sequence coverage. In the analysis of MCF7 cell lysate, we show collision-induced dissociation (CID) and electron-transfer dissociation (ETD) on each precursor on a liquid chromatography-mass spectrometry (LC-MS) timescale and improve mean sequence coverage dramatically (CID-only 15% vs chimeric 33%), even during discovery-based acquisition. This approach can also be utilized to multiplex the acquisition of product ion spectra of multiple charge states from a single protein precursor or multiple ETD/proton-transfer reactions (PTR) reaction periods. The analytical utility of chimeric ion loading is demonstrated for top-down proteomics, but it is also likely to be impactful for tandem mass spectrometry applications in other areas.


Asunto(s)
Proteínas de Neoplasias/análisis , Proteómica , Análisis de Fourier , Humanos , Células MCF-7 , Espectrometría de Masas en Tándem , Células Tumorales Cultivadas
8.
J Am Soc Mass Spectrom ; 31(9): 1783-1802, 2020 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-32812765

RESUMEN

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information on the common TD/MD MS methods and practices in the field. A panel of three mAbs was selected and centrally provided to 20 laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). Various MS instrument platforms and ion dissociation techniques were employed. The present study confirms that TD/MD MS tools are available in laboratories worldwide and provide complementary information to the BU approach that can be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. A primary limitation revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS.


Asunto(s)
Anticuerpos Monoclonales , Espectrometría de Masas/métodos , Proteómica/métodos , Animales , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/genética , Regiones Determinantes de Complementariedad/análisis , Regiones Determinantes de Complementariedad/química , Regiones Determinantes de Complementariedad/genética , Humanos , Ratones
10.
Anal Chem ; 92(4): 3213-3219, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-32011122

RESUMEN

Stored waveform inverse Fourier transform (SWIFT) is a versatile method to generate complex isolation/ejection waveforms for precursor isolation prior to tandem mass spectrometry experiments. Here, we report ultrahigh resolving power ion isolation by SWIFT on a 21 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Individual histone proteoforms are isolated (0.6 m/z isolation window) with near 100% efficiency using a 52 ms SWIFT isolation, followed by in-cell fragmentation by ultraviolet photodissociation (UVPD). Ion isolation resolving power of 175 000 (m/Δm) is demonstrated by isolation of individual peaks at a spacing of 0.0034 Da at m/z 597 from a complex mixture of Canadian bitumen. An individual m/z ion, which corresponds to a single elemental composition, from a complex mixture is isolated and fragmented by infrared multiphoton dissociation (IRMPD). Theoretical and experimental considerations that limit achievable ion isolation resolving power are discussed.


Asunto(s)
Ciclotrones , Análisis de Fourier , Espectrometría de Masas/instrumentación , Secuencia de Aminoácidos , Histonas , Proteómica , Relación Señal-Ruido
11.
Anal Chem ; 92(4): 3133-3142, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-31955581

RESUMEN

Detailed characterization of complex biological surfaces by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) requires instrumentation that is capable of high mass resolving power, mass accuracy, and dynamic range. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers the highest mass spectral performance for MALDI MSI experiments, and often reveals molecular features that are unresolved on lower performance instrumentation. Higher magnetic field strength improves all performance characteristics of FT-ICR; mass resolving power improves linearly, while mass accuracy and dynamic range improve quadratically with magnetic field strength. Here, MALDI MSI at 21T is demonstrated for the first time: mass resolving power in excess of 1 600 000 (at m/z 400), root-mean-square mass measurement accuracy below 100 ppb, and dynamic range per pixel over 500:1 were obtained from the direct analysis of biological tissue sections. Molecular features with m/z differences as small as 1.79 mDa were resolved and identified with high mass accuracy. These features allow for the separation and identification of lipids to the underlying structures of tissues. The unique molecular detail, accuracy, sensitivity, and dynamic range combined in a 21T MALDI FT-ICR MSI experiment enable researchers to visualize molecular structures in complex tissues that have remained hidden until now. The instrument described allows for future innovative, such as high-end studies to unravel the complexity of biological, geological, and engineered organic material surfaces with an unsurpassed detail.

12.
Clin Chem ; 65(8): 986-994, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31040099

RESUMEN

BACKGROUND: Hemoglobinopathies and thalassemias are the most common genetically determined disorders. Current screening methods include cation-exchange HPLC and electrophoresis, the results of which can be ambiguous because of limited resolving power. Subsequently, laborious genetic testing is required for confirmation. METHODS: We performed a top-down tandem mass spectrometry (MS/MS) approach with a fast data acquisition (3 min), ultrahigh mass accuracy, and extensive residue cleavage by use of positive electrospray ionization 21 Tesla Fourier transform ion cyclotron resonance-tandem mass spectrometry (21 T FT-ICR MS/MS) for hemoglobin (Hb) variant de novo sequencing and ß-thalassemia diagnosis. RESULTS: We correctly identified all Hb variants in blind analysis of 18 samples, including the first characterization of homozygous Hb Himeji variant. In addition, an Hb heterozygous variant with isotopologue mass spacing as small as 0.0194 Da (Hb AD) was resolved in both precursor ion mass spectrum (MS1) and product ion mass spectrum (MS2). In blind analysis, we also observed that the abundance ratio between intact δ and ß subunits (δ/ß) or the abundance ratio between intact δ and α subunits (δ/α) could serve to diagnose ß-thalassemia trait caused by a mutation in 1 HBB gene. CONCLUSIONS: We found that 21 T FT-ICR MS/MS provides a benchmark for top-down MS/MS analysis of blood Hb. The present method has the potential to be translated to lower resolving power mass spectrometers (lower field FT-ICR mass spectrometry and Orbitrap) for Hb variant analysis (by MS1 and MS2) and ß-thalassemia diagnosis (MS1).


Asunto(s)
Análisis de Fourier , Hemoglobinopatías/sangre , Hemoglobinas/química , Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodos , Talasemia beta/sangre , Secuencia de Aminoácidos , Ciclotrones , Variación Genética , Hemoglobinopatías/genética , Humanos , Sensibilidad y Especificidad , Análisis de Secuencia de Proteína/métodos , Globinas alfa/química , Globinas beta/química , Talasemia beta/genética , Globinas delta/química
13.
Anal Chem ; 91(5): 3263-3269, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30801187

RESUMEN

The current five-year survival rate for systemic AL amyloidosis or multiple myeloma is ∼51%, indicating the urgent need for better diagnosis methods and treatment plans. Here, we describe highly specific and sensitive top-down and middle-down MS/MS methods owning the advantages of fast sample preparation, ultrahigh mass accuracy, and extensive residue cleavages with 21 telsa FT-ICR MS/MS. Unlike genomic testing, which requires bone marrow aspiration and may fail to identify all monoclonal immunoglobulins produced by the body, the present method requires only a blood draw. In addition, circulating monoclonal immunoglobulins spanning the entire population are analyzed and reflect the selection of germline sequence by B cells. The monoclonal immunoglobulin light chain FR2-CDR2-FR3 was sequenced by database-aided de novo MS/MS and 100% matched the gene sequencing result, except for two amino acids with isomeric counterparts, enabling accurate germline sequence classification. The monoclonal immunoglobulin heavy chains were also classified into specific germline sequences based on the present method. This work represents the first application of top/middle-down MS/MS sequencing of endogenous human monoclonal immunoglobulins with polyclonal immunoglobulins background.


Asunto(s)
Amiloidosis/clasificación , Cadenas Ligeras de Inmunoglobulina/sangre , Mieloma Múltiple/clasificación , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Amiloidosis/diagnóstico , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/metabolismo , Cromatografía Líquida de Alta Presión , Análisis de Fourier , Humanos , Cadenas Ligeras de Inmunoglobulina/química , Inmunoglobulinas/aislamiento & purificación , Inmunoglobulinas/metabolismo , Mieloma Múltiple/diagnóstico , Paraproteinemias/clasificación , Paraproteinemias/diagnóstico
14.
Anal Chem ; 90(3): 2041-2047, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29303558

RESUMEN

We describe complex organic mixture analysis by 21 tesla (T) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Ultrahigh mass-resolving power (m/Δm50% > 2 700 000 at m/z 400) and mass accuracy (80 ppb rms) enable resolution and confident identification of tens of thousands of unique elemental compositions. We demonstrate 2.2-fold higher mass-resolving power, 2.6-fold better mass measurement accuracy, and 1.3-fold more assigned molecular formulas compared to our custom-built, state-of-the-art 9.4 T FT-ICR mass spectrometer for petroleum and dissolved organic matter (DOM) analyses. Analysis of a heavy petroleum distillate exemplifies the need for ultrahigh-performance mass spectrometry (49 040 assigned molecular formulas for 21 T versus 29 012 for 9.4 T) and extends the identification of previously unresolved Oo, SsOo, and NOo classes. Mass selective ion accumulation (20 Thompson isolation) of an asphalt volcano sample yields 462 resolved mass spectral peaks at m/z 677 and reveals previously unresolved CcHhNnOoSs mass differences at high mass (m/z > 600). Similar performance gains are realized in the analysis of dissolved organic matter, where doubly charged Oo species are resolved from singly charged SOo species, which requires a mass-resolving power greater than 1 400 000 (at m/z 600). This direct comparison reveals the continued need for higher mass-resolving power and better mass accuracy for comprehensive molecular characterization of the most complex organic mixtures.

15.
J Am Soc Mass Spectrom ; 28(9): 1787-1795, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28721671

RESUMEN

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. Graphical Abstract ᅟ.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/análisis , Proteínas/química , Análisis de Secuencia de Proteína/métodos , Electrones , Diseño de Equipo , Análisis de Fourier , Espectrometría de Masas/instrumentación , Análisis de Secuencia de Proteína/instrumentación , Espectrometría de Masas en Tándem
16.
J Am Soc Mass Spectrom ; 28(5): 827-838, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28247297

RESUMEN

With the rapid growth of therapeutic monoclonal antibodies (mAbs), stringent quality control is needed to ensure clinical safety and efficacy. Monoclonal antibody primary sequence and post-translational modifications (PTM) are conventionally analyzed with labor-intensive, bottom-up tandem mass spectrometry (MS/MS), which is limited by incomplete peptide sequence coverage and introduction of artifacts during the lengthy analysis procedure. Here, we describe top-down and middle-down approaches with the advantages of fast sample preparation with minimal artifacts, ultrahigh mass accuracy, and extensive residue cleavages by use of 21 tesla FT-ICR MS/MS. The ultrahigh mass accuracy yields an RMS error of 0.2-0.4 ppm for antibody light chain, heavy chain, heavy chain Fc/2, and Fd subunits. The corresponding sequence coverages are 81%, 38%, 72%, and 65% with MS/MS RMS error ~4 ppm. Extension to a monoclonal antibody in human serum as a monoclonal gammopathy model yielded 53% sequence coverage from two nano-LC MS/MS runs. A blind analysis of five therapeutic monoclonal antibodies at clinically relevant concentrations in human serum resulted in correct identification of all five antibodies. Nano-LC 21 T FT-ICR MS/MS provides nonpareil mass resolution, mass accuracy, and sequence coverage for mAbs, and sets a benchmark for MS/MS analysis of multiple mAbs in serum. This is the first time that extensive cleavages for both variable and constant regions have been achieved for mAbs in a human serum background. Graphical Abstract ᅟ.


Asunto(s)
Adalimumab/sangre , Anticuerpos Monoclonales/sangre , Paraproteinemias/sangre , Espectrometría de Masas en Tándem/métodos , Adalimumab/análisis , Secuencia de Aminoácidos , Anticuerpos Monoclonales/análisis , Análisis de Fourier , Humanos , Procesamiento Proteico-Postraduccional , Programas Informáticos , Espectrometría de Masa por Ionización de Electrospray/métodos
18.
J Proteome Res ; 16(2): 1087-1096, 2017 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-27936753

RESUMEN

Successful high-throughput characterization of intact proteins from complex biological samples by mass spectrometry requires instrumentation capable of high mass resolving power, mass accuracy, sensitivity, and spectral acquisition rate. These limitations often necessitate the performance of hundreds of LC-MS/MS experiments to obtain reasonable coverage of the targeted proteome, which is still typically limited to molecular weights below 30 kDa. The National High Magnetic Field Laboratory (NHMFL) recently installed a 21 T FT-ICR mass spectrometer, which is part of the NHMFL FT-ICR User Facility and available to all qualified users. Here we demonstrate top-down LC-21 T FT-ICR MS/MS of intact proteins derived from human colorectal cancer cell lysate. We identified a combined total of 684 unique protein entries observed as 3238 unique proteoforms at a 1% false discovery rate, based on rapid, data-dependent acquisition of collision-induced and electron-transfer dissociation tandem mass spectra from just 40 LC-MS/MS experiments. Our identifications included 372 proteoforms with molecular weights over 30 kDa detected at isotopic resolution, which substantially extends the accessible mass range for high-throughput top-down LC-MS/MS.


Asunto(s)
Neoplasias Colorrectales/química , Espectrometría de Masas/métodos , Proteínas de Neoplasias/análisis , Proteoma/análisis , Proteómica/métodos , Secuencia de Aminoácidos , Neoplasias Colorrectales/patología , Mezclas Complejas/química , Ciclotrones/instrumentación , Análisis de Fourier , Humanos , Espectrometría de Masas/instrumentación , Proteómica/instrumentación
19.
Artículo en Inglés | MEDLINE | ID: mdl-26307725

RESUMEN

A three-dimensional code based on the particle-in-cell algorithm modified to account for the inhomogeneity of the magnetic field was applied to determine the effect of Z(1), Z(2), Z(3), Z(4), X, Y, ZX, ZY, XZ(2) YZ(2), XY and X(2)-Y(2) components of an orthogonal magnetic field expansion on ion motion during detection in an FT-ICR cell. Simulations were performed for magnetic field strengths of 4.7, 7, 14.5 and 21 Tesla, including experimentally determined magnetic field spatial distributions for existing 4.7 T and 14.5 T magnets. The effect of magnetic field inhomogeneity on ion cloud stabilization ("ion condensation") at high numbers of ions was investigated by direct simulations of individual ion trajectories. Z(1), Z(2), Z(3) and Z(4) components have the largest effect (especially Z(1)) on ion cloud stability. Higher magnetic field strength and lower m/z demand higher relative magnetic field homogeneity to maintain cloud coherence for a fixed time period. The dependence of mass resolving power upper limit on Z(1) inhomogeneity is evaluated for different magnetic fields and m/z. The results serve to set the homogeneity requirements for various orthogonal magnetic field components (shims) for future FT-ICR magnet design.


Asunto(s)
Artefactos , Ciclotrones , Iones/análisis , Iones/química , Modelos Químicos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Simulación por Computador , Iones/efectos de la radiación , Campos Magnéticos , Movimiento (Física) , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Am Soc Mass Spectrom ; 26(9): 1626-32, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26091892

RESUMEN

We describe the design and initial performance of the first 21 tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The 21 tesla magnet is the highest field superconducting magnet ever used for FT-ICR and features high spatial homogeneity, high temporal stability, and negligible liquid helium consumption. The instrument includes a commercial dual linear quadrupole trap front end that features high sensitivity, precise control of trapped ion number, and collisional and electron transfer dissociation. A third linear quadrupole trap offers high ion capacity and ejection efficiency, and rf quadrupole ion injection optics deliver ions to a novel dynamically harmonized ICR cell. Mass resolving power of 150,000 (m/Δm(50%)) is achieved for bovine serum albumin (66 kDa) for a 0.38 s detection period, and greater than 2,000,000 resolving power is achieved for a 12 s detection period. Externally calibrated broadband mass measurement accuracy is typically less than 150 ppb rms, with resolving power greater than 300,000 at m/z 400 for a 0.76 s detection period. Combined analysis of electron transfer and collisional dissociation spectra results in 68% sequence coverage for carbonic anhydrase. The instrument is part of the NSF High-Field FT-ICR User Facility and is available free of charge to qualified users.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...