Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Int J Biometeorol ; 68(6): 1169-1178, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38602550

RESUMEN

Examining how heat affects people with Parkinson's disease is essential for informing clinical decision-making, safety, well-being, and healthcare planning. While there is evidence that the neuropathology associated with Parkinson's disease affects thermoregulatory mechanisms, little attention has been given to the association of heat sensitivity to worsening symptoms and restricted daily activities in people with this progressive disease. Using a cross-sectional study design, we examined the experiences of people diagnosed with Parkinson's disease in the heat. Two-hundred and forty-seven people completed an online survey (age: 66.0 ± 9.2 years; sex: male = 102 (41.3%), female = 145 (58.7%)), of which 195 (78.9%) reported becoming more sensitive to heat with Parkinson's disease. Motor and nonmotor symptoms worsened with heat in 182 (73.7%) and 203 (82.2%) respondents, respectively. The most commonly reported symptoms to worsen included walking difficulties, balance impairment, stiffness, tremor, fatigue, sleep disturbances, excess sweating, difficulty concentrating, and light-headedness when standing. Concerningly, over half indicated an inability to work effectively in the heat, and nearly half reported that heat impacted their ability to perform household tasks and social activities. Overall, heat sensitivity was common in people with Parkinson's disease and had a significant impact on symptomology, day-to-day activities and quality of life.


Asunto(s)
Calor , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/fisiopatología , Masculino , Femenino , Anciano , Persona de Mediana Edad , Estudios Transversales , Calor/efectos adversos , Sensación Térmica , Actividades Cotidianas , Encuestas y Cuestionarios
2.
PLoS One ; 15(12): e0243133, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33290429

RESUMEN

BACKGROUND: It is unclear how dual-task gait influences the lower limb range of motion (RoM) in people with Parkinson's disease (PD) and freezing of gait (FOG). The lower limb kinematics during dual-task gait might differ from regular gait, but during what events in the gait cycle? METHODS: This is an observational within-subjects study. Thirty-two individuals with PD and FOG underwent a gait analysis. Single and dual-task gait was assessed by a 3D motion analysis system and the RoM data of the lower limb were extracted from hips, knees and ankles in the sagittal plane. Dual-task assignment was performed using word-color interference test. To compare both gait conditions, we used two different analyses: (1) common discrete analysis to provide lower limb RoM and (2) Statistical Parametric Mapping analysis (SPM) to provide lower limb joint kinematics. A correlation between lower limb RoM and spatiotemporal gait parameters was also performed for each gait condition. RESULTS: Common discrete analysis evidenced reductions in RoM of hips, knees and ankles during the dual task gait when compared to single gait. SPM analysis showed reductions in flexion-extension of hip, knees and ankles joints when dual task was compared to single task gait. These reductions were observed in specific gait events as toe off (for knees and ankles) and heel strike (for all joints). The reduction in lower limb RoM was positively correlated with the reduction in step length and gait speed. CONCLUSIONS: Lower limb joints kinematics were reduced during toe off and heel strike in dual task gait when compared to single gait. These findings might help physiotherapists to understand the influence of dual and single walking in lower limb RoM throughout the gait cycle in people with PD and FOG.


Asunto(s)
Marcha/fisiología , Pierna/fisiología , Enfermedad de Parkinson/fisiopatología , Rango del Movimiento Articular/fisiología , Caminata/fisiología , Anciano , Femenino , Humanos , Masculino
3.
J Neuroeng Rehabil ; 16(1): 110, 2019 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-31488184

RESUMEN

BACKGROUND: Impairments of functional mobility may affect locomotion and quality of life in subjects with Parkinson's disease (PD). Movement smoothness measurements, such as the spectral arc length (SPARC), are novel approaches to quantify movement quality. Previous studies analyzed SPARC in simple walking conditions. However, SPARC outcomes during functional mobility tasks in subjects with PD and freezing of gait (FOG) were never investigated. This study aimed to analyze SPARC during the Timed Up and Go (TUG) test in individuals with PD and FOG. METHODS: Thirty-one participants with PD and FOG and six healthy controls were included. SPARC during TUG test was calculated for linear and angular accelerations using an inertial measurement unit system. SPARC data were correlated with clinical parameters: motor section of the Unified Parkinson's Disease Rating Scale, Hoehn & Yahr scale, Freezing of Gait Questionnaire, and TUG test. RESULTS: We reported lower SPARC values (reduced smoothness) during the entire TUG test, turn and stand to sit in subjects with PD and FOG, compared to healthy controls. Unlike healthy controls, individuals with PD and FOG displayed a broad spectral range that encompassed several dominant frequencies. SPARC metrics also correlated with all the above-mentioned clinical parameters. CONCLUSION: SPARC values provide valid and relevant clinical data about movement quality (e.g., smoothness) of subjects with PD and FOG during a functional mobility test.


Asunto(s)
Trastornos Neurológicos de la Marcha/fisiopatología , Movimiento , Enfermedad de Parkinson/fisiopatología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Limitación de la Movilidad , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Caminata
4.
Sensors (Basel) ; 19(13)2019 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-31284455

RESUMEN

The consequences of falls, costs, and complexity of conventional evaluation protocols have motivated researchers to develop more effective balance assessments tools. Healthcare practitioners are incorporating the use of mobile phones and other gadgets (smartphones and tablets) to enhance accessibility in balance evaluations with reasonable sensitivity and good cost-benefit. The prospects are evident, as well as the need to identify weakness and highlight the strengths of the different approaches. In order to verify if mobile devices and other gadgets are able to assess balance, four electronic databases were searched from their inception to February 2019. Studies reporting the use of inertial sensors on mobile and other gadgets to assess balance in healthy adults, compared to other evaluation methods were included. The quality of the nine studies selected was assessed and the current protocols often used were summarized. Most studies did not provide enough information about their assessment protocols, limiting the reproducibility and the reliability of the results. Data gathered from the studies did not allow us to conclude if mobile devices and other gadgets have discriminatory power (accuracy) to assess postural balance. Although the approach is promising, the overall quality of the available studies is low to moderate.


Asunto(s)
Teléfono Celular , Monitoreo Fisiológico/métodos , Equilibrio Postural/fisiología , Teléfono Inteligente , Adolescente , Adulto , Anciano , Brazo/fisiología , Estudios de Cohortes , Estudios Transversales , Femenino , Pie/fisiología , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Procesamiento de Señales Asistido por Computador , Dispositivos Electrónicos Vestibles
5.
Front Physiol ; 9: 310, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29651253

RESUMEN

During a continuously increasing exercise workload (WL) a point will be reached at which arterial lactate accumulates rapidly. This so-called lactate threshold (LT) is associated with the maximal lactate steady state workload (MLSSW), the highest WL, at which arterial lactate concentration [LA] does not change. However, the physiological range in which the LT and the MLSSW occur has not been demonstrated directly. We used minor WL variations in the MLSSW range to assess arterial lactate kinetics in 278 treadmill and 148 bicycle ergometer exercise tests. At a certain workload, minimal further increment of running speed (0.1-0.15 m/s) or cycling power (7-10 W) caused a steep elevation of [LA] (0.9 ± 0.43 mM, maximum increase 2.4 mM), indicating LT achievement. This sharp [LA] increase was more pronounced when higher WL increments were used (0.1 vs. 0.30 m/s, P = 0.02; 0.15 vs. 0.30 m/s, P < 0.001; 7 vs. 15 W, P = 0.002; 10 vs. 15 W, P = 0.001). A subsequent workload reduction (0.1 m/s/7 W) stopped the [LA] increase indicating MLSSW realization. LT based determination of running speed (MLSSW) was highly reproducible on a day-to-day basis (r = 0.996, P < 0.001), valid in a 10 km constant velocity setting (r = 0.981, P < 0.001) and a half marathon race (r = 0.969, P < 0.001). These results demonstrate a fine-tuned regulation of exercise-related lactate metabolism, which can be reliably captured by assessing lactate kinetics at the MLSSW.

6.
Int J Artif Organs ; 39(4): 178-83, 2016 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-27034319

RESUMEN

AIM: In current rotary blood pumps, complications related to blood trauma due to shear stresses are still frequently observed clinically. Reducing the rotor tip speed might decrease blood trauma. Therefore, the aim of this project was to design a two-stage rotary blood pump leading to lower shear stresses. METHODS: Using the principles of centrifugal pumps, two diagonal rotor stages were designed with an outer diameter of 22 mm. The first stage begins with a flow straightener and terminates with a diffusor, while a volute casing behind the second stage is utilized to guide fluid to the outlet. Both stages are combined into one rotating part which is pivoted by cup-socket ruby bearings. Details of the flow field were analyzed employing computational fluid dynamics (CFD). A functional model of the pump was fabricated and the pressure-flow dependency was experimentally assessed. RESULTS: Measured pressure-flow performance of the developed pump indicated its ability to generate adequate pressure heads and flows with characteristic curves similar to centrifugal pumps. According to the CFD results, a pressure of 70 mmHg was produced at a flow rate of 5 L/min and a rotational speed of 3200 rpm. Circumferential velocities could be reduced to 3.7 m/s as compared to 6.2 m/s in a clinically used axial rotary blood pump. Flow fields were smooth with well-distributed pressure fields and comparatively few recirculation or vortices. Substantially smaller volumes were exposed to high shear stresses >150 Pa. CONCLUSIONS: Hence, blood trauma might be reduced with this design. Based on these encouraging results, future in vitro investigations to investigate actual blood damage are intended.


Asunto(s)
Diseño de Equipo , Eritrocitos , Corazón Auxiliar , Hemólisis/fisiología , Humanos , Hidrodinámica , Estrés Mecánico
7.
PLoS One ; 10(6): e0130290, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26110847

RESUMEN

BACKGROUND: The peroneal muscles are the most effective lateral stabilisers whose tension braces the ankle joint complex against excessive supination. The purpose of this study was to identify the morphological and biomechanical effects of two machine-based shank muscle training methods. METHODS: Twenty-two healthy male recreationally active sports students performed ten weeks of single-set high resistance strength training with 3 training sessions per week. The subjects conducted subtalar pronator/supinator muscle training (ST) with the right leg by using a custom-made apparatus; the left foot muscles were exercised with machine-based talocrural plantar and dorsiflexor training (TT). Muscle strength (MVIC), muscle volume and foot biomechanics (rearfoot motion, ground reaction forces, muscle reaction times) during a sudden ankle supination were recorded before and after the intervention. RESULTS: Compared to TT, ST resulted in significantly higher pronator (14% vs. 8%, P<0.01) and supinator MVIC (25% vs. 12%, P<0.01). During sudden foot inversions, both ST and TT resulted in reduced supination velocity (-12%; P<0.01). The muscle reaction onset time was faster after the training in peroneus longus (PL) (P<0.01). Muscle volume of PL (P<0.01) and TA (P<0.01) increased significantly after both ST and TT. CONCLUSION: After both ST and TT, the ankle joint complex is mechanically more stabilised against sudden supinations due to the muscle volume increase of PL and TA. As the reduced supination velocities indicate, the strength training effects are already present during free-fall. According to a sudden ankle supination in standing position, both machine-based dorsiflexor and pronator strength training is recommended for enhancing the mechanical stability of the ankle.


Asunto(s)
Articulación del Tobillo/fisiología , Tobillo/fisiología , Pie/fisiología , Fuerza Muscular/fisiología , Entrenamiento de Fuerza , Supinación/fisiología , Adulto , Humanos , Masculino , Músculo Esquelético/fisiología
8.
Med Eng Phys ; 37(7): 642-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25962379

RESUMEN

Whole-body vibration (WBV) training has become popular in recent years. However, WBV may be harmful to the human body. The goal of this study was to determine the acceleration magnitudes at different body segments for different frequencies of WBV. Additionally, vibration sensation ratings by subjects served to create perception vibration magnitude and discomfort maps of the human body. In the first of two experiments, 65 young adults mean (± SD) age range of 23 (± 3.0) years, participated in WBV severity perception ratings, based on a Borg scale. Measurements were performed at 12 different frequencies, two intensities (3 and 5 mm amplitudes) of rotational mode WBV. On a separate day, a second experiment (n = 40) included vertical accelerometry of the head, hip and lower leg with the same WBV settings. The highest lower limb vibration magnitude perception based on the Borg scale was extremely intense for the frequencies between 21 and 25 Hz; somewhat hard for the trunk region (11-25 Hz) and fairly light for the head (13-25 Hz). The highest vertical accelerations were found at a frequency of 23 Hz at the tibia, 9 Hz at the hip and 13 Hz at the head. At 5 mm amplitude, 61.5% of the subjects reported discomfort in the foot region (21-25 Hz), 46.2% for the lower back (17, 19 and 21 Hz) and 23% for the abdominal region (9-13 Hz). The range of 3-7 Hz represents the safest frequency range with magnitudes less than 1 g(*)sec for all studied regions.


Asunto(s)
Cabeza/fisiología , Cadera/fisiología , Pierna/fisiología , Percepción del Tacto/fisiología , Vibración , Acelerometría , Femenino , Humanos , Masculino , Dimensión del Dolor , Umbral del Dolor/fisiología , Estimulación Física , Vibración/efectos adversos , Adulto Joven
9.
Eur J Cardiothorac Surg ; 47(6): 984-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25209626

RESUMEN

OBJECTIVES: The implantable continuous-flow left ventricular assist devices (LVADs) HeartMate II (HM II) and HeartWare HVAD (HW) underwent design modifications. The impact of these changes on life-threatening pump malfunctions was evaluated. METHODS: We retrospectively analysed pump malfunctions due to thrombosis or cable damage in patients supported with primarily implanted HM II (n = 191) and HW (n = 347), separated into patients supported with the old and new pump designs. In 2010, the cable strain relief of the HM II device was improved (132 patients with old and 79 with new) and sealed grafts were introduced (68 patients with sealed inflow connector and outflow graft and 125 without). In 2011, titanium sintering of the inflow cannula of HW pumps was introduced (137 patients with a non-sintered and 210 with a sintered inflow cannula). RESULTS: The median support time was 1.12 (0-6.1) years for all HM II and 0.59 (0-4.2) years for all HW patients. The cumulative rate of events per patient-year (EPPY) was 0.11 in HM II patients, compared with 0.09 EPPY in HW patients (P = 0.32). After introduction of the new cable design, incidence of cable damage in HM II patients dropped from 0.06 to 0 EPPY (P = 0.03), whereas pump thrombosis increased from 0.02 to 0.14 EPPY (P < 0.001) after the sealed graft was introduced. Pump thrombosis occurred in 4% of patients supported with HW with a sintered inflow cannula vs 15% with a non-sintered pump; the incidence changed from 0.10 to 0.07 EPPY in sintered pumps (P = 0.45). Kaplan-Meier analysis showed no differences over a period of 2.5 years for events when the HM II cohort with sealed graft and new cable design (n = 68) was compared with the HW group with a sintered cannula (P = 0.14). CONCLUSIONS: The modified cable strain relief of the HM II pump and the sintering of the inflow cannula of the HW pump demonstrated a significant reduction in the incidence of life-threatening pump-related complications, whereas the sealed inflow connector and outflow graft seem to be associated with a higher incidence of pump thrombosis. However, the overall incidence of pump-related complications after the latest design changes was similar for both pumps over a 2.5-year period.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/mortalidad , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/estadística & datos numéricos , Diseño de Prótesis/mortalidad , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis , Adulto Joven
10.
BMC Musculoskelet Disord ; 15: 88, 2014 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-24628720

RESUMEN

BACKGROUND: Femoroacetabular impingement (FAI) is predominant in young male athletes, but not much is known about gait differences in cases of increased hip alpha angles. In our study, the hip alpha angle of Nötzli of soccer players was quantified on the basis of magnetic resonance imaging (MRI) with axial oblique sequences. The aim of the current study was to compare the rearfoot motion and plantar pressure in male semiprofessional soccer players with increased alpha angles to age-matched amateur soccer players. METHODS: In a prospective analysis, male semiprofessional and amateur soccer players had an MRI of the right hip to measure the alpha angle of Nötzli. In a biomechanical laboratory setting, 14 of these participants in each group ran in two shoe conditions. Simultaneously in-shoe pressure distribution, tibial acceleration, and rearfoot motion measurements of the right foot were performed. RESULTS: In the semiprofessional soccer group, the mean value of the alpha angle of group was 55.1 ± 6.58° (range 43.2-76.6°) and 51.6 ± 4.43° (range 41.9-58.8°) in the amateur group. In both shoe conditions, we found a significant difference between the two groups concerning the ground reaction forces, tibial acceleration, rearfoot motion and plantar pressure parameters (P < 0.01, P < 0.05, P = 0.04). Maximum rearfoot motion is about 22% lower in the semiprofessional group compared to the amateur group in both shoe conditions. CONCLUSIONS: This study confirmed that semiprofessional soccer players with increased alpha angles showed differences in gait kinematics compared to the amateur group. These findings support the need for a screening program for competitive soccer players. In cases of a conspicuous gait analysis and symptomatic hip pain, FAI must be ruled out by further diagnostic tests.


Asunto(s)
Atletas , Pinzamiento Femoroacetabular/etiología , Articulación de la Cadera/anatomía & histología , Carrera/fisiología , Fútbol , Aceleración , Antropometría , Susceptibilidad a Enfermedades , Pinzamiento Femoroacetabular/diagnóstico , Pinzamiento Femoroacetabular/patología , Pie/fisiología , Marcha , Articulación de la Cadera/fisiología , Humanos , Pierna/fisiología , Masculino , Movimiento (Física) , Variaciones Dependientes del Observador , Presión/efectos adversos , Estudios Prospectivos , Carrera/lesiones , Zapatos , Método Simple Ciego , Fútbol/lesiones , Posición Supina , Adulto Joven
11.
PLoS One ; 8(12): e83309, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24349486

RESUMEN

BACKGROUND: Degradation of the somatosensory system has been implicated in postural instability and increased falls risk for older people and Parkinson's disease (PD) patients. Here we demonstrate that textured insoles provide a passive intervention that is an inexpensive and accessible means to enhance the somatosensory input from the plantar surface of the feet. METHODS: 20 healthy older adults (controls) and 20 participants with PD were recruited for the study. We evaluated effects of manipulating somatosensory information from the plantar surface of the feet using textured insoles. Participants performed standing tests, on two different surfaces (firm and foam), under three footwear conditions: 1) barefoot; 2) smooth insoles; and 3) textured insoles. Standing balance was evaluated using a force plate yielding data on the range of anterior-posterior and medial-lateral sway, as well as standard deviations for anterior-posterior and medial-lateral sway. RESULTS: On the firm surface with eyes open both the smooth and textured insoles reduced medial-lateral sway in the PD group to a similar level as the controls. Only the textured insole decreased medial-lateral sway and medial-lateral sway standard deviation in the PD group on both surfaces, with and without visual input. Greatest benefits were observed in the PD group while wearing the textured insoles, and when standing on the foam surface with eyes closed. CONCLUSIONS: Data suggested that textured insoles may provide a low-cost means of improving postural stability in high falls-risk groups, such as people with PD.


Asunto(s)
Accidentes por Caídas/prevención & control , Ortesis del Pié , Enfermedad de Parkinson/fisiopatología , Equilibrio Postural , Postura , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
13.
Eur J Cardiothorac Surg ; 44(1): 139-45, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22858453

RESUMEN

OBJECTIVES: A third-generation ventricular assist device, the HeartWare Ventricular Assist System, has demonstrated its reliability and durability in animal models and clinical experience. However, studies of a large series of applications are still lacking. We evaluate the safety and efficacy of the HeartWare pump in 141 patients with end-stage heart failure at a single centre. METHODS: A total of 141 patients (116 men and 25 women with a mean age of 52 years) in New York Heart Association (NYHA) Class IV received implantation of the HeartWare Ventricular Assist System between August 2009 and April 2011 at the Deutsches Herzzentrum Berlin. The outcomes were measured in terms of laboratory data, adverse events, NYHA functional class and survival during device support. RESULTS: The HeartWare system provided an adequate haemodynamic support for patients both inside and outside the hospital. NYHA class improved to I-II. Organ function and pulmonary vascular resistance improved significantly. In this cohort of patients, 14 patients underwent heart transplantation, one had had the device explanted following myocardial recovery, one had changed to another assist device, 81 were on ongoing support and 44 died. The overall actuarial survival rates at 6 and 12 months were 70 and 67%, respectively, and the 3-, 6- and 12-month survival rates on a left ventricular assist device (LVAD) support for bridge to transplantation patients were 82, 81 and 79%, respectively. Infection and bleeding were the main adverse events. Four patients underwent an LVAD exchange for pump thrombosis. CONCLUSIONS: The HeartWare system provides a safe and effective circulatory support in a population with a wide range of body surface areas, with a satisfactory actuarial survival time and an improved quality of life. It can be used for univentricular or biventricular support, being implanted into the pericardial space with simplified surgical techniques.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos , Niño , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Hemodinámica/fisiología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Factores de Riesgo , Resultado del Tratamiento
14.
Circulation ; 124(11 Suppl): S179-86, 2011 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-21911810

RESUMEN

BACKGROUND: Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow the use of 2 implantable centrifugal left ventricular assist devices as a biventricular assist system. METHODS AND RESULTS: Seventeen patients have been implanted with 2 HeartWare HVAD pumps, 1 as a left ventricular assist device and 1 as a right ventricular assist device. Seventy-seven percent of the patients had idiopathic dilated or ischemic cardiomyopathy. Their age ranged from 29 to 73 years (mean 51.8 ± 14.5 years), and 11 (64.7%) received intravenous catecholamine support preoperatively. The right ventricular assist device pump was implanted into the right ventricular free wall. The afterload of this pump was artificially increased by local reduction of the outflow graft diameter, and the effective length of its inflow cannula was reduced by the addition of two 5-mm silicon suture rings to the original HVAD implantation ring. All right ventricular assist device devices could be operated in appropriate speed ranges and delivered a flow of between 3.0 and 5.5 L/min. Thirty-day survival was 82%, and 59% of the patients could be discharged home after recovering from the operation. There was no clinically relevant hemolysis in any of the patients. CONCLUSIONS: Two HeartWare HVAD pumps can be used as a biventricular assist system. This implantable biventricular support gives the patients more comfort and mobility than usual biventricular ventricular assist devices with large and noisy displacement pumps.


Asunto(s)
Cardiomiopatía Dilatada/cirugía , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/clasificación , Adulto , Anciano , Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/fisiopatología , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/cirugía , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/cirugía
15.
ASAIO J ; 57(5): 382-7, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21869615

RESUMEN

Little is known about the hemolysis rate in the case of concomitant implantation of two continuous flow pumps for the treatment of biventricular heart failure. We present a retrospective study comparing the hemolysis parameters in patients supported with one implantable centrifugal pump of the type HeartWare HVAD used as a left ventricular assist device (LVAD) and with two pumps as a biventricular assist device (BiVAD). A total of 20 consecutive patients who received HeartWare BiVAD (n = 10) and LVAD (n = 10) support at our institution between September 2009 and September 2010 were examined. Hemolysis- and anemia-related parameters were analyzed after 2 weeks, 5 weeks, 3 months, and 6 months of support. Preoperative levels of hemoglobin, lactate dehydrogenase (LDH), and total bilirubin were similar in both groups. There were no differences in LDH, plasma-free hemoglobin (fHB), or total bilirubin levels postoperatively for up to 6 months. Only the haptoglobin level was lower in BiVAD recipients up to 3 months after surgery: 2nd week (63.5 [range: 8-237] mg/dl vs. 151 [range: 11-263] mg/dl, p = 0.05), 5th week (67 [range: 8-196] mg/dl vs. 215 [range: 56-292] mg/dl, p = 0.046), and after 3rd month (42 [range: 8-205] mg/dl vs. 220 [range: 157-256] mg/dl, p = 0.048). Our retrospective analysis of BiVAD HeartWare and LVAD HeartWare recipients showed a lack of a clinically important degree of hemolysis when two centrifugal HeartWare pumps are used for biventricular support.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Hemólisis , Adulto , Anciano , Anemia/patología , Anticoagulantes/química , Diseño de Equipo , Femenino , Insuficiencia Cardíaca/sangre , Hemoglobinas/química , Hemoglobinas/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Retrospectivos , Resultado del Tratamiento , Función Ventricular Izquierda
16.
Res Sports Med ; 19(3): 186-201, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21722006

RESUMEN

Although soccer is the most popular sport in the world, little research has been published in the field of soccer biomechanics, particularly on the importance of footwear for the game. The traction properties of soccer shoes on natural and artificial turf have been speculated to be responsible for acute and chronic injuries in soccer. This article reviewed the current knowledge on how soccer shoes influence the risk of injuries and how they may serve to improve player performance. Comfort is the highest priority that players want from their shoes, followed by traction and stability. Cleat design and arrangement are important shoe features that allow for fast accelerations and stops, rapid cuts, and turns. Soccer shoe design can influence shooting speed and, even more important for the game of soccer, kicking accuracy. To combine shoe characteristics for injury prevention and better performance will be a challenge for future research on optimizing soccer shoes.


Asunto(s)
Traumatismos en Atletas , Rendimiento Atlético , Zapatos , Fútbol/lesiones , Femenino , Humanos , Masculino , Riesgo , Factores Sexuales
17.
J Appl Biomech ; 27(1): 22-31, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21451179

RESUMEN

Nordic walking (NW) was compared with walking (W) and running (R) with respect to upper and lower limb injury risks. 24 NW-instructors performed W, NW, and R trials on a runway covered with artificial turf at controlled speeds. Foot pronation and ground reaction forces were measured as well as shock wave transmission to the right wrist. Comparison of NW and W shows similar results for all of the four chosen velocities (5 km/h, 7 km/h, 8 km/h, 8.5 km/h). Except for the 2nd peak of the vertical ground reaction force, NW results in higher loading rates and horizontal forces as well as higher pronation and pronation velocity values as compared with W. Wrist acceleration values up to 7.6 times gravitational acceleration were recorded in NW. Compared with R at the same speeds (8 km/h and 8.5 km/h), NW can be recommended as low impact sport with 36% lower loading rates and 59% lower pronation velocities. However, the high wrist accelerations in NW reveal that the upper extremities are exposed to considerable repetitive shocks, which may cause overuse injuries of the upper extremities. Thus, additional preventive exercises for the upper limb muscles are recommended as well as using shock absorbing walking poles.


Asunto(s)
Brazo/fisiología , Pierna/fisiología , Carrera/fisiología , Esquí/fisiología , Caminata/fisiología , Soporte de Peso/fisiología , Adulto , Femenino , Marcha/fisiología , Humanos , Masculino , Esfuerzo Físico/fisiología
18.
J Cardiovasc Transl Res ; 4(3): 332-9, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21394530

RESUMEN

The implantation of ventricular assist devices (VADs) is a valuable option in patients with end-stage heart failure. The number of VAD implantations is growing worldwide. Between July 1987 and July 2010, we implanted 1,598 VADs in 1,455 patients. The majority were male (81.0%), and their mean age was 49.4 years (range 0.3-82 years). Indications for implantation were: cardiomyopathy (n = 1,074), post-cardiotomy heart failure (n = 282), acute myocardial infarction (n = 83), graft failure after heart transplantation (n = 64), and others (n = 61). In 55.5%, the VAD implanted was left ventricular, in 39.5% biventricular, and in 4.8% right ventricular. Until 1995, the implanted pumps were mostly pulsatile. Today, however, more than 95% of the implanted VADs are continuous-flow rotary pumps. The average support time was 148.6 days (range 0-1,836 days). The percentage of biventricular VADs has dropped over the years to 20% in 2009. Three hundred forty-seven patients could be successfully bridged to heart transplantation. In 122 patients (8.3%), the device could be explanted after myocardial recovery. In 2009, 31.4% of the patients were implanted for permanent support. During the study period, 521 patients could be discharged home or to a rehabilitation center. Implantation of ventricular assist devices is now an established treatment for patients with both acute and chronic end-stage heart failure. Small implantable left ventricular assist devices of the second and third generation are now broadly employed worldwide, with growing acceptance and decreasing complications. The percentage of biventricular support has dropped over the years to 20%.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar/tendencias , Función Ventricular Izquierda , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Niño , Preescolar , Femenino , Alemania/epidemiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Lactante , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Miniaturización , Diseño de Prótesis , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
19.
J Thorac Cardiovasc Surg ; 141(3): 616-23, 623.e1, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21335121

RESUMEN

BACKGROUND: Pediatric ventricular assist devices may be superior to extracorporeal membrane oxygenation in some respects, especially for medium- and long-term cardiac support. We present our nearly 20-year experience with pediatric ventricular assist devices. METHODS: Between 1990 and April 2009, Berlin Heart EXCOR (Berlin Heart AG, Berlin, Germany) was implanted in 94 children. Patients were compared according to period of treatment: group I, implantation between 1990 and 2001 (n = 45), and group II, implantation since 2002 (n = 49). RESULTS: Preoperative serum creatinine (1.2 vs 0.7 mg/dL, P = .002) and bilirubin (1.5 vs 1 mg/dL, P = .002) were lower in period II, and fewer patients were artificially ventilated before surgery (26 vs 13, P = .002). In period I, more patients were supported with biventricular assist devices (64% vs 22.5%, P < .001). Median time on support was shorter in period I (10 vs 40 days, P < .001). Success (weaning from system or heart transplant) was achieved in 49% and 69%, respectively (P = .043). Whereas in period I 17% of children younger than 1 year were discharged home after transplant or weaning, rate during period II was 93% (P < .001), in particular because of improvement in discharge rate of patients with postcardiotomy heart failure (13% vs 50%). Rates of pump exchange for thrombus formation were 0.029/d in period I and 0.014/d in period II (P = 0.003). CONCLUSIONS: Recent results show significant improvements in survival and discharge rate, especially for children younger than 1 year. Pediatric Berlin Heart EXCOR ventricular assist device may provide a safe mechanical support strategy in children with cardiogenic shock.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico/terapia , Adolescente , Anticoagulantes/uso terapéutico , Bilirrubina/sangre , Biomarcadores/sangre , Distribución de Chi-Cuadrado , Niño , Preescolar , Creatinina/sangre , Femenino , Alemania , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Mortalidad Hospitalaria , Humanos , Lactante , Recién Nacido , Masculino , Alta del Paciente , Diseño de Prótesis , Respiración Artificial , Estudios Retrospectivos , Choque Cardiogénico/sangre , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Tasa de Supervivencia , Trombosis/etiología , Trombosis/prevención & control , Factores de Tiempo , Resultado del Tratamiento
20.
ASAIO J ; 57(3): 183-7, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21336105

RESUMEN

We have developed a method that allows the use of a commercially available implantable left ventricular assist device (LVAD; HeartWare HVAD) for right ventricular (RV) assistance. A mock circulation was used to examine the flow characteristics of the system with different outflow diameters (10-4 mm). Furthermore, we looked for a material for safe and satisfactory reduction of the effective length of the inflow cannula for better fitting to the RV dimensions. Reduction of the outflow graft to an inner diameter of ∼5 mm adds as much resistance to the system that in patients with a normal pulmonary resistance, the pump would deliver between 3.5 and 7 L/min. We added two 5 mm silicon suture rings to the system's "apical" sewing ring to reduce the effective length of the inflow cannula. Connection of the pump to the anterior free wall of the right ventricle ensures good orientation of the inflow cannula within the RV cavity, with sufficient space to prevent the inflow cannula from suction to the opposite interventricular septum. The HeartWare LVAD pump seems also to be usable as a right ventricular assist device (RVAD) after a few, but important, modifications of the implant procedure.


Asunto(s)
Corazón Auxiliar , Disfunción Ventricular Derecha/terapia , Circulación Coronaria , Diseño de Equipo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Técnicas In Vitro , Circulación Pulmonar , Resistencia Vascular , Disfunción Ventricular Derecha/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...