Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 11(1): 18929, 2021 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-34556697

RESUMEN

Early diagnosis of acute mesenteric ischemia (AMI) remains a clinical challenge, and no biomarker has been consistently validated. We aimed to assess the accuracy of three promising circulating biomarkers for diagnosing AMI-citrulline, intestinal fatty acid-binding protein (I-FABP), and D-lactate. A cross-sectional diagnostic study enrolled AMI patients admitted to the intestinal stroke center and controls with acute abdominal pain of another origin. We included 129 patients-50 AMI and 79 controls. Plasma citrulline concentrations were significantly lower in AMI patients compared to the controls [15.3 µmol/L (12.0-26.0) vs. 23.3 µmol/L (18.3-29.8), p = 0.001]. However, the area under the receiver operating curves (AUROC) for the diagnosis of AMI by Citrulline was low: 0.68 (95% confidence interval = 0.58-0.78). No statistical difference was found in plasma I-FABP and plasma D-lactate concentrations between the AMI and control groups, with an AUROC of 0.44, and 0.40, respectively. In this large cross-sectional study, citrulline, I-FABP, and D-lactate failed to differentiate patients with AMI from patients with acute abdominal pain of another origin. Further research should focus on the discovery of new biomarkers.


Asunto(s)
Abdomen Agudo/diagnóstico , Diagnóstico Precoz , Isquemia Mesentérica/diagnóstico , Abdomen Agudo/sangre , Abdomen Agudo/etiología , Adulto , Anciano , Biomarcadores , Citrulina/sangre , Estudios Transversales , Proteínas de Unión a Ácidos Grasos/sangre , Femenino , Humanos , Ácido Láctico/sangre , Masculino , Isquemia Mesentérica/sangre , Isquemia Mesentérica/complicaciones , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
2.
Clin Chem Lab Med ; 55(6): 817-825, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28222020

RESUMEN

BACKGROUND: High-dose biotin therapy is beneficial in progressive multiple sclerosis (MS) and is expected to be adopted by a large number of patients. Biotin therapy leads to analytical interference in many immunoassays that utilize streptavidin-biotin capture techniques, yielding skewed results that can mimic various endocrine disorders. We aimed at exploring this interference, to be able to remove biotin and avoid misleading results. METHODS: We measured free triiodothyronine (fT3), free thyroxine (fT4), thyroid-stimulating hormone (TSH), parathyroid homrone (PTH), 25-hydroxyvitamin D (25OHD), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin, C-peptide, cortisol (Roche Diagnostics assays), biotin and its main metabolites (liquid chromatography tandem mass spectrometry) in 23 plasmas from MS patients and healthy volunteers receiving high-dose biotin, and in 39 biotin-unsupplemented patients, before and after a simple procedure (designated N5) designed to remove biotin by means of streptavidin-coated microparticles. We also assayed fT4, TSH and PTH in the 23 high-biotin plasmas using assays not employing streptavidin-biotin binding. RESULTS: The biotin concentration ranged from 31.7 to 1160 µg/L in the 23 high-biotin plasmas samples. After the N5 protocol, the biotin concentration was below the detection limit in all but two samples (8.3 and 27.6 µg/L). Most hormones results were abnormal, but normalized after N5. All results with the alternative methods were normal except two slight PTH elevations. In the 39 biotin-unsupplemented patients, the N5 protocol did not affect the results for any of the hormones, apart from an 8.4% decrease in PTH. CONCLUSIONS: We confirm that most streptavidin-biotin hormone immunoassays are affected by high biotin concentrations, leading to a risk of misdiagnosis. Our simple neutralization method efficiently suppresses biotin interference.


Asunto(s)
Artefactos , Biotina/uso terapéutico , Análisis Químico de la Sangre/métodos , Sistema Endocrino/metabolismo , Inmunoensayo/métodos , Biotina/aislamiento & purificación , Biotina/metabolismo , Estudios de Casos y Controles , Relación Dosis-Respuesta a Droga , Femenino , Hormonas/sangre , Humanos , Masculino , Esclerosis Múltiple/sangre , Esclerosis Múltiple/tratamiento farmacológico , Estreptavidina/metabolismo
3.
PLoS One ; 6(10): e26245, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22046264

RESUMEN

The diagnostic of orphan genetic disease is often a puzzling task as less attention is paid to the elucidation of the pathophysiology of these rare disorders at the molecular level. We present here a multidisciplinary approach using molecular modeling tools and surface plasmonic resonance to study the function of the ATP7B protein, which is impaired in the Wilson disease. Experimentally validated in silico models allow the elucidation in the Nucleotide binding domain (N-domain) of the Mg(2+)-ATP coordination site and answer to the controversial role of the Mg(2+) ion in the nucleotide binding process. The analysis of protein motions revealed a substantial effect on a long flexible loop branched to the N-domain protein core. We demonstrated the capacity of the loop to disrupt the interaction between Mg(2+)-ATP complex and the N-domain and propose a role for this loop in the allosteric regulation of the nucleotide binding process.


Asunto(s)
Adenosina Trifosfatasas/metabolismo , Proteínas de Transporte de Catión/química , Adenosina Trifosfatasas/química , Regulación Alostérica , Sitios de Unión , Proteínas de Transporte de Catión/metabolismo , Simulación por Computador , ATPasas Transportadoras de Cobre , Humanos , Unión Proteica , Estructura Terciaria de Proteína
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...