Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomed Chromatogr ; 38(7): e5871, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38599686

RESUMEN

We report the development and the validation of a sensitive liquid chromatography-mass spectrometry (LC-MS/MS) method for mometasone furoate (MF) analysis in human plasma. Plasma samples were processed through liquid-liquid extraction and analyzed using LC-MS/MS operating in positive mode using multiple reaction monitoring of transitions m/z 520.9 â†’ 355.0 and m/z 525.8 â†’ 355.0 for MF and the internal standard (IS), respectively. Separation was achieved at 1.0 mL/min on a C18 column using a gradient elution of mobile phase of 0.05% ammonia in water (phase A) and acetonitrile (phase B). The assay range was 0.250-100 pg/mL and proved to be accurate and precise MF. Normalized recoveries were consistent and reproducible with a coefficient of variation (CV%) value of 6.0. The CV (%) of the IS normalized matrix factor was not observed in normal, lipemic, and hemolyzed plasmas. Dilutions of 1:10 were accurately quantified. A cycle of three freeze and thaw and stabilities at room temperature and on the autosampler were demonstrated. In addition, MF in the presence of indacaterol and glycopyrronium was proven to be stable at -70°C for at least 157 days. The present method was successfully applied to quantify MF in patients receiving MF, indacaterol, and glycopyrronium as a fixed-dose combination.


Asunto(s)
Furoato de Mometasona , Espectrometría de Masas en Tándem , Humanos , Furoato de Mometasona/sangre , Furoato de Mometasona/farmacocinética , Furoato de Mometasona/química , Espectrometría de Masas en Tándem/métodos , Reproducibilidad de los Resultados , Cromatografía Liquida/métodos , Modelos Lineales , Sensibilidad y Especificidad , Estabilidad de Medicamentos , Extracción Líquido-Líquido/métodos , Límite de Detección , Cromatografía Líquida con Espectrometría de Masas
2.
Biomed Chromatogr ; 38(1): e5769, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37937618

RESUMEN

Sample preparation is essential for low-level compound determination. In the present work, supported liquid extraction (SLE) was used as sample preparation for the low-level determination of a new TLR7 agonist imiquimod compound, LFX453. Samples were extracted on ISOLUTE® SLE 96-well plates using tert-butyl-methyl ether followed by evaporation and dry residue reconstitution with 150 µl of a mixture of 0.1% formic acid in acetonitrile-water (50/50, v/v). Samples were eluted using a flow rate of 0.750 ml/min on a C18 column (50 × 2.1 mm, 2.7 µm) with a mobile phase consisting of 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B). Tandem mass spectrometry was used to analyze the samples in positive mode. The method run time was 6.5 min, and the low limit of quantification was 1.00 pg/ml with 0.100 ml of minipig plasma. Intra-run and inter-run precision and accuracy were within the acceptance criteria at four concentration levels over a concentration ranging from 1.00 to 200 pg/ml. There was no matrix effect and recovery, three freeze-thaw cycles and incurred samples reanalysis were validated. The method was successfully applied for measuring LFX453 in minipig plasma after application on minipig skin.


Asunto(s)
Espectrometría de Masas en Tándem , Receptor Toll-Like 7 , Animales , Porcinos , Espectrometría de Masas en Tándem/métodos , Imiquimod , Reproducibilidad de los Resultados , Porcinos Enanos , Cromatografía Liquida/métodos , Agua , Acetonitrilos , Cromatografía Líquida de Alta Presión/métodos
3.
BMC Pulm Med ; 21(1): 18, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413291

RESUMEN

BACKGROUND: A once-daily (o.d.) fixed-dose combination of indacaterol acetate (IND), glycopyrronium bromide (GLY), and mometasone furoate (MF) delivered via the Breezhaler® device (IND/GLY/MF) is being developed for treatment of asthma. This study compared steady-state pharmacokinetics of IND, GLY and MF between Japanese and Caucasian male subjects after multiple inhalations of IND/GLY/MF o.d. METHODS: This was a single-center, open-label, 2-treatment crossover study with a 21-day washout period. Japanese and Caucasian subjects received IND/GLY/MF 150/50/80 µg (inhaled corticosteroid [ICS] medium-dose) or 150/50/160 µg o.d. (ICS high-dose) for 14 days in each period. Pharmacokinetics were characterized up to 24 h post-dose on Days 1 and 14. RESULTS: In total, 16 Japanese (median age 31 years [range 20-40 years], mean weight 68.3 kg) and 17 Caucasian subjects (median age 27 years [range 21-43 years], mean weight 75.0 kg) were randomized. Geometric mean ratios (Japanese/Caucasian) [90% confidence interval (CI)] for Cmax for IND, GLY and MF at the high ICS dose on Day 14 were 1.31 [1.13, 1.51] 1.38 [1.13, 1.69] and 1.07 [0.969, 1.18], respectively. Geometric mean ratios (Japanese/Caucasian) [90% CI] for AUC0-24h on Day 14 for IND, GLY and MF at the high ICS dose were 1.17 [1.01, 1.35], 1.05 [0.920, 1.20] and 1.15 [1.05, 1.27] respectively. Similar trends were noted for all components for the medium ICS dose treatment. IND/GLY/MF was safe and well tolerated; no AEs suspected to be study drug-related were observed. CONCLUSION: Pharmacokinetics of IND, GLY and MF (high and medium dose) when delivered as a fixed-dose combination were comparable between Japanese and Caucasian subjects. The IND/GLY/MF combination at the administrated doses was safe and well tolerated in both ethnic groups. TRIAL REGISTRATION: Japan Registry of Clinical Trial: jRCT2031200227, retrospectively registered on 04, December, 2020.


Asunto(s)
Antiasmáticos/farmacocinética , Glicopirrolato/farmacocinética , Indanos/farmacocinética , Furoato de Mometasona/farmacocinética , Quinolonas/farmacocinética , Administración por Inhalación , Adulto , Antiasmáticos/administración & dosificación , Pueblo Asiatico , Estudios Cruzados , Combinación de Medicamentos , Femenino , Glicopirrolato/administración & dosificación , Voluntarios Sanos , Humanos , Indanos/administración & dosificación , Masculino , Furoato de Mometasona/administración & dosificación , Quinolonas/administración & dosificación , Población Blanca , Adulto Joven
4.
Pulm Pharmacol Ther ; 64: 101964, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33035700

RESUMEN

Indacaterol (IND), is co-formulated with glycopyrronium (GLY), and mometasone furoate (MF) as a once-daily (o.d.) inhaled fixed-dose combination (IND/GLY/MF) delivered via the Breezhaler® device for maintenance treatment of asthma. We evaluated the steady state plasma pharmacokinetics (PK) of IND, GLY and MF following inhalation of IND/GLY/MF or as monotherapies. This was a randomized, open-label, four-way crossover study. Subjects received IND/GLY/MF 150/50/160 µg (high-dose), IND 150 µg, GLY 50 µg or MF 190 µg (in vitro fine particle mass comparable to 160 µg MF in IND/GLY/MF) via the Breezhaler® device, o.d. for 14 days in each period, with a washout of at least 7 days. PK was characterized on Day 14, up to 24 h post-dose. In total, 36 healthy subjects were randomized. For IND, the geometric mean ratios (90% CI) for AUC0-24h,ss and Cmax,ss were 0.922 (0.878, 0.969) and 1.02 (0.967, 1.08), respectively for the IND/GLY/MF versus IND monotherapy comparison. For GLY, the geometric mean ratios (90% CI) for AUC0-24h,ss and Cmax,ss were 0.986 (0.944, 1.03) and 1.21 (1.09, 1.34), respectively for the IND/GLY/MF versus GLY comparison. For MF, the geometric mean ratios (90% CI) for AUC0-24h,ss and Cmax,ss were 1.16 (1.09, 1.24) and 1.17 (1.09, 1.25), respectively for IND/GLY/MF versus MF comparison. Similar systemic exposure was noted for IND/GLY/MF versus monotherapy for all three mono-components, indicating a lack of PK interaction. Multiple inhaled doses of IND, GLY and MF were safe and well tolerated, when administered alone or in combination. There was no clinically relevant pharmacokinetic interaction between IND, GLY and MF when administered as IND/GLY/MF.


Asunto(s)
Glicopirrolato , Estudios Cruzados , Combinación de Medicamentos , Voluntarios Sanos , Humanos , Indanos , Furoato de Mometasona , Quinolonas
5.
Biomed Chromatogr ; 34(10): e4909, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32485782

RESUMEN

We report a selective LC-MS/MS method for the simultaneous quantitative determinations of the adenosine A2a receptor antagonist NIR178 (NIR178) and its major metabolite NJI765 in human plasma. Sample preparation steps involved protein precipitation, sample evaporation and reconstitution using a plasma sample volume of 0.1 ml plasma. Separation was achieved in 10 min on an Acquity UPLC BEH C18 1.7 µm, 2.1 × 50 mm column heated at 60°C with a gradient elution at 0.6 ml/min mobile phase made of water and acetonitrile both acidified with 0.1% formic acid. The detection was performed in positive ion mode and quantification based on multiple reaction monitoring. The linear response range was 1.00-1,000 ng/ml using a 1/x2 weighting factor. The intra- and inter-day accuracies (bias %) and intra- and inter-day precisions (CV, %) obtained for NIR178 and NJI765 were within the acceptance criteria. The normalized NIR178 and NJI765 matrix factor calculated from six lots of normal, lipemic and hemolyzed plasmas ranged from 0.97 to 1.05. The normalized recoveries of both NIR178 and NJI765 compared with their internal standards were consistent and reproducible with a CV ≤8.0. This method was successfully applied to support pharmacokinetic studies in adult patients with cancer.


Asunto(s)
Antagonistas del Receptor de Adenosina A2/sangre , Cromatografía Liquida/métodos , Piridinas/sangre , Espectrometría de Masas en Tándem/métodos , Antagonistas del Receptor de Adenosina A2/química , Antagonistas del Receptor de Adenosina A2/farmacocinética , Humanos , Modelos Lineales , Piridinas/química , Piridinas/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Anal Chem ; 89(4): 2628-2635, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28192936

RESUMEN

The quantitative analysis of human immunoglobulin G1 (hIgG1) by mass spectrometry is commonly performed using surrogate peptides after enzymatic digestion. Since some limitations are associated with this approach, a novel workflow is presented by hybridizing ligand binding assay (LBA) with liquid chromatography-high-resolution mass spectrometry (LC-HRMS) for hIgG1 quantification directly at the intact protein level. Different hIgG1s, including a [13C]-labeled version used as internal standard, were immuno-enriched from rat serum with a fully automated platform based on streptavidin coated tips and a biotinylated mouse anti-hIgG capture antibody targeting the fragment crystallizable region followed by overnight deglycosylation prior to LC-HRMS analysis. The proposed quantitative workflow utilized extracted ion chromatograms (XICs) from the nondeconvoluted full-scan MS spectrum. The assay was validated in terms of selectivity, sensitivity, accuracy/precision, carry-over, dilution linearity, and reproducibility. Consistent data between the conventional approach based on surrogate peptide analysis and our proposed workflow were obtained in vitro and in vivo with the advantage of a less extensive sample pretreatment. Multiplexing capabilities for simultaneous quantification of different hIgG1s within the same spiked sample were also exemplified. Altogether our results pave the way not only for the thorough application of intact hIgG1 quantification by LBA-LC-HRMS but also as a generic quantitative analytical method for other hIgG isotypes or next generation biotherapeutics.


Asunto(s)
Inmunoglobulina G/análisis , Ligandos , Espectrometría de Masas en Tándem , Animales , Biotinilación , Cromatografía Líquida de Alta Presión , Evaluación Preclínica de Medicamentos , Femenino , Semivida , Humanos , Inmunoensayo , Inmunoglobulina G/sangre , Inmunoglobulina G/metabolismo , Péptidos/análisis , Ratas , Ratas Wistar , Reproducibilidad de los Resultados
8.
J Pharm Biomed Anal ; 131: 214-222, 2016 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-27599352

RESUMEN

An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000µg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00µg/mL whereas for FNW at 5.00µg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities.


Asunto(s)
Cromatografía Liquida/métodos , Inmunoglobulina G/sangre , Fragmentos de Péptidos/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Macaca fascicularis , Ratas , Reproducibilidad de los Resultados
9.
Drug Metab Dispos ; 44(7): 897-910, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27122302

RESUMEN

For antibody drug conjugates (ADCs), the fate of the cytotoxic payload in vivo needs to be well understood to mitigate toxicity risks and properly design the first in-patient studies. Therefore, a distribution, metabolism, and excretion (DME) study with a radiolabeled rat cross-reactive ADC ([(3)H]DM1-LNL897) targeting the P-cadherin receptor was conducted in female tumor-bearing nude rats. Although multiple components [total radioactivity, conjugated ADC, total ADC, emtansine (DM1) payload, and catabolites] needed to be monitored with different technologies (liquid scintillation counting, liquid chromatography/mass spectrometry, enzyme-linked immunosorbent assay, and size exclusion chromatography), the pharmacokinetic data were nearly superimposable with the various techniques. [(3)H]DM1-LNL897 was cleared with half-lives of 51-62 hours and LNL897-related radioactivity showed a minor extent of tissue distribution. The highest tissue concentrations of [(3)H]DM1-LNL897-related radioactivity were measured in tumor. Complimentary liquid extraction surface analysis coupled to micro-liquid chromatography-tandem mass spectrometry data proved that the lysine (LYS)-4(maleimidylmethyl) cyclohexane-1-carboxylate-DM1 (LYS-MCC-DM1) catabolite was the only detectable component distributed evenly in the tumor and liver tissue. The mass balance was complete with up to 13.8% ± 0.482% of the administered radioactivity remaining in carcass 168 hours postdose. LNL897-derived radioactivity was mainly excreted via feces (84.5% ± 3.12%) and through urine only to a minor extent (4.15% ± 0.462%). In serum, the major part of radioactivity could be attributed to ADC, while small molecule disposition products were the predominant species in excreta. We show that there is a difference in metabolite profiles depending on which derivatization methods for DM1 were applied. Besides previously published results on LYS-MCC-DM1 and MCC-DM1, maysine and a cysteine conjugate of DM1 could be identified in serum and excreta.


Asunto(s)
Anticuerpos/metabolismo , Antineoplásicos Fitogénicos/farmacocinética , Neoplasias de la Mama/tratamiento farmacológico , Inmunoconjugados/farmacocinética , Maitansina/farmacocinética , Administración Intravenosa , Animales , Anticuerpos/administración & dosificación , Anticuerpos/sangre , Antineoplásicos Fitogénicos/administración & dosificación , Antineoplásicos Fitogénicos/sangre , Área Bajo la Curva , Disponibilidad Biológica , Biotransformación , Neoplasias de la Mama/sangre , Neoplasias de la Mama/patología , Cadherinas/inmunología , Cadherinas/metabolismo , Línea Celular Tumoral , Heces/química , Femenino , Semivida , Humanos , Inmunoconjugados/administración & dosificación , Inmunoconjugados/sangre , Maitansina/administración & dosificación , Maitansina/sangre , Tasa de Depuración Metabólica , Ratas Desnudas , Distribución Tisular
10.
Bioanalysis ; 8(10): 1035-49, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27095045

RESUMEN

AIM: A sensitive generic LC-MS/MS method for hIgG1 quantification in cynomolgus monkey serum using mass spectrometric immunoassay disposable automation research tips (MSIA-D.A.R.T.'S™) is reported. RESULTS: The hIgG1 was captured with a biotinylated mouse anti-hIgG antibody (50.0 µg/ml) targeting the fragment crystallizable (Fc) region. Elution from the streptavidin-coated MSIA-D.A.R.T.'s was conducted with 0.4% trifluoroacetic acid in water. The method was selective and linear from 10.0 to 1000 ng/ml using 100 µl of serum. The method was evaluated regarding accuracy, precision, carry-over, dilution, auto-sampler stability and applied for the determination of hIgG1 concentration in monkey serum after intravitreal administration. CONCLUSION: The present assay is suitable for quantitative analysis of hIgG1-based therapeutic proteins in monkey serum at low levels.


Asunto(s)
Inmunoensayo/métodos , Inmunoglobulina G/sangre , Macaca fascicularis/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Anticuerpos Antiidiotipos/química , Biotinilación , Cromatografía Liquida/métodos , Inmunoglobulina G/análisis , Límite de Detección , Ratones
11.
Anal Biochem ; 501: 23-5, 2016 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-26893107

RESUMEN

The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC-MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 µg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents.


Asunto(s)
Inmunoglobulina G/sangre , Secuencia de Aminoácidos , Animales , Cromatografía Liquida , Humanos , Inmunoglobulina G/análisis , Límite de Detección , Ratas , Espectrometría de Masas en Tándem
12.
J Pharm Biomed Anal ; 120: 322-32, 2016 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-26771131

RESUMEN

A sensitive and specific method was developed and validated for the quantitation of maytansinoid (DM1) in human serum using on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS). Because DM1 contains a free thiol moiety, likely to readily dimerize or react with other thiol-containing molecules in serum, samples were pre-treated with a reducing agent [tris (2-carboxyethyl) phosphine] (TCEP) and further blocked with N-ethylmaleimide (NEM). The resulting samples were diluted with acetonitrile prior to the on-line solid phase extraction (SPE) on a C18 cartridge. A C18 (150×4.6mm ID 3µm particle size) column was used for chromatographic separation with a 10.0min HPLC gradient and DM1-NEM was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. DM1 concentrations were back-calculated from DM1-NEM amount found in the human serum samples. The quantitation range of the method was 0.200-200ng/mL when using 0.25mL serum. Within-run day precisions (n=6) were 0.9-4.4% and between-run day (3 days runs; n=18) precisions 2.5-5.6%. Method biases were between 3.5-14.5% across the whole calibration range. DM1-NEM exhibited sufficiently stability under all relevant analytical conditions and no DM1 losses from the ADC were observed. Finally, the assay was used for DM1 determination in human serum concentration after the intravenous administration of an investigational antibody drug conjugate (ADC) containing DM1 as payload.


Asunto(s)
Maitansina/análogos & derivados , Extracción en Fase Sólida/métodos , Extracción en Fase Sólida/normas , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Humanos , Infusiones Intravenosas , Maitansina/administración & dosificación , Maitansina/sangre , Neoplasias/sangre , Neoplasias/tratamiento farmacológico , Reproducibilidad de los Resultados
13.
Anal Bioanal Chem ; 408(6): 1687-99, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26758601

RESUMEN

In the present study, the application of a liquid chromatography high-resolution mass spectrometry (LC-HRMS) analytical assay for the quantitative analysis of a recombinant human immunoglobulin G1 (hIgG1) in rat serum is reported using three generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), and VVSVLTVLHQDWLNGK (VVS). Moreover, the deamidation site of a fourth peptide FNWYVDGVEVHNAK (FNW) was identified and further excluded from the assay evaluation due to the inaccuracy of the quantitative results. The rat serum samples were spiked with a fully labeled hIgG1 as internal standard (ISTD). The digestion with trypsin was performed onto the pellet prior to peptide analysis by LC-HRMS using a quadrupole time of flight (QTOF) mass analyzer operating in selected reaction monitoring (SRM) mode with enhanced duty cycles (EDC). The assay linearity for the three investigated peptides was established for a hIgG1 (hIgG1A) from 1.00 to 1000 µg mL(-1) with a mean coefficient of determination (R (2)) higher than 0.9868. The inter-day accuracy and precision obtained in rat serum over 3 days were ≤11.4 and ≤10.5%, respectively. Short-term stability on the auto-sampler at 6 °C for 30 h, at RT for 48 h, and a 100-fold dilution factor were demonstrated. In addition, QC samples prepared in cynomolgus monkey serum and measured with the present method met the acceptance criteria of ±20.0 and ≤20.0% for all three peptides regarding accuracy and precision, respectively. The LC-HRMS method was applied to the analysis of samples from five individual cynomolgus monkeys dosed with a second hIgG1 (hIgG1B) and consistent data were obtained compared to the LC-MS/MS method (conventional triple quadrupole (QqQ) mass analyzer operating in SRM). The present data demonstrate that LC-HRMS can be used for the quantitative analysis of hIgG1 in both species and that quantification is not only limited to classical QqQ instruments.


Asunto(s)
Inmunoglobulina G/sangre , Espectrometría de Masas/métodos , Proteínas Recombinantes/sangre , Secuencia de Aminoácidos , Animales , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Femenino , Humanos , Inmunoglobulina G/genética , Macaca fascicularis , Espectrometría de Masas/normas , Datos de Secuencia Molecular , Péptidos/química , Péptidos/metabolismo , Ratas , Proteínas Recombinantes/genética , Proteínas Recombinantes/farmacología , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/métodos
14.
Bioanalysis ; 7(4): 425-35, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25747762

RESUMEN

AIM: An ultrafast, sensitive, selective and robust LDTD-APCI-MS/MS method was developed for the quantification of ceritinib in human plasma. RESULTS: Samples were protein precipitated using acetonitrile containing [(13)C6]-ceritinib as internal standard. The assay was validated over a concentration range from 5.00 to 1000 ng/ml. Intra- and inter-day precision and accuracy met acceptance from EMA and US FDA guidelines. The normalized recovery was 69%, whereas no carryover and matrix effects were observed. The method was applied to clinical samples and resultant data were consistent with the LC-ESI-MS/MS reference method. CONCLUSION: The new assay is suitable for ceritinib quantification in clinical trials, whereas the analysis time is significantly reduced to 10 s.


Asunto(s)
Análisis Químico de la Sangre/métodos , Ensayos Clínicos como Asunto , Rayos Láser , Espectrometría de Masas/métodos , Pirimidinas/sangre , Sulfonas/sangre , Análisis Químico de la Sangre/instrumentación , Humanos , Límite de Detección , Modelos Lineales , Espectrometría de Masas/instrumentación , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem , Factores de Tiempo
15.
Anal Chem ; 87(4): 2068-71, 2015 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-25607538

RESUMEN

Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 µL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.


Asunto(s)
Recolección de Muestras de Sangre/instrumentación , Pruebas con Sangre Seca/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Hematócrito , Humanos , Reproducibilidad de los Resultados
16.
Anal Bioanal Chem ; 406(28): 7389-96, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25258279

RESUMEN

Ceritinib is a highly selective inhibitor of an important cancer target, anaplastic lymphoma kinase (ALK). Because it is an investigational compound, there is a need to develop a robust and reliable analytical method for its quantitative determination in human plasma. Here, we report the validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the rapid quantification of ceritinib in human plasma. The method consists of protein precipitation with acetonitrile, and salting-out assisted liquid-liquid extraction (SALLE) using a saturated solution of sodium chloride prior to analysis by LC-MS/MS with electrospray ionization (ESI) technique in positive mode. Samples were eluted at 0.800 mL min(-1) on Ascentis Express® C18 column (50 mm × 2.1 mm, 2.7 µm) with a mobile phase made of 0.1 % formic acid in water (A) and 0.1 % formic acid in acetonitrile (B). The method run time was 3.6 min and the low limit of quantification (LLOQ) was estimated at 1.00 ng mL(-1) when using 0.100 mL of human plasma. The assay was fully validated and the method exhibited sufficient specificity, accuracy, precision, and sensitivity. In addition, recovery data and matrix factor (MF) in normal and in hemolyzed plasmas were assessed, while incurred samples stability (ISS) for ceritinib was demonstrated for at least 21 months at a storage temperature of -65 °C or below. The method was successfully applied to the measurement of ceritinib in clinical samples and the data obtained on incurred samples reanalysis (ISR) showed that our method was reliable and suitable to support the analysis of samples from the clinical studies.


Asunto(s)
Antineoplásicos/sangre , Antineoplásicos/farmacocinética , Cromatografía Liquida/métodos , Pirimidinas/sangre , Pirimidinas/farmacocinética , Sulfonas/sangre , Sulfonas/farmacocinética , Espectrometría de Masas en Tándem/métodos , Antineoplásicos/farmacología , Ensayos Clínicos Fase I como Asunto , Humanos , Extracción Líquido-Líquido , Neoplasias/tratamiento farmacológico , Neoplasias/metabolismo , Pirimidinas/farmacología , Sulfonas/farmacología , Distribución Tisular
17.
Anal Bioanal Chem ; 406(22): 5413-23, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24958346

RESUMEN

A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell™ plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL(-1) with a coefficient of determination (R (2)) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell™ plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n = 847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.


Asunto(s)
Aminopiridinas/sangre , Rayos Láser , Extracción Líquido-Líquido/métodos , Morfolinas/sangre , Plasma/química , Espectrometría de Masas en Tándem/métodos , Atmósfera , Presión Atmosférica , Calibración , Química Farmacéutica/métodos , Cromatografía Liquida , Humanos , Modelos Lineales , Control de Calidad , Valores de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray , Temperatura , Factores de Tiempo
18.
Drug Metab Dispos ; 42(3): 431-40, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24389421

RESUMEN

Absorption, distribution, metabolism, and excretion properties of a small interfering RNA (siRNA) formulated in a lipid nanoparticle (LNP) vehicle were determined in male CD-1 mice following a single intravenous administration of LNP-formulated [(3)H]-SSB siRNA, at a target dose of 2.5 mg/kg. Tissue distribution of the [(3)H]-SSB siRNA was determined using quantitative whole-body autoradiography, and the biostability was determined by both liquid chromatography mass spectrometry (LC-MS) with radiodetection and reverse-transcriptase polymerase chain reaction techniques. Furthermore, the pharmacokinetics and distribution of the cationic lipid (one of the main excipients of the LNP vehicle) were investigated by LC-MS and matrix-assisted laser desorption ionization mass spectrometry imaging techniques, respectively. Following i.v. administration of [(3)H]-SSB siRNA in the LNP vehicle, the concentration of parent guide strand could be determined up to 168 hours p.d. (post dose), which was ascribed to the use of the vehicle. This was significantly longer than what was observed after i.v. administration of the unformulated [(3)H]-SSB siRNA, where no intact parent guide strand could be observed 5 minutes post dosing. The disposition of the siRNA was determined by the pharmacokinetics of the formulated LNP vehicle itself. In this study, the radioactivity was widely distributed throughout the body, and the total radioactivity concentration was determined in selected tissues. The highest concentrations of radioactivity were found in the spleen, liver, esophagus, stomach, adrenal, and seminal vesicle wall. In conclusion, the LNP vehicle was found to drive the kinetics and biodistribution of the SSB siRNA. The renal clearance was significantly reduced and its exposure in plasma significantly increased compared with the unformulated [(3)H]-SSB siRNA.


Asunto(s)
Portadores de Fármacos/metabolismo , Lípidos/farmacocinética , Nanopartículas/metabolismo , ARN Interferente Pequeño/metabolismo , Animales , Autorradiografía , Cromatografía Líquida de Alta Presión , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Estabilidad de Medicamentos , Inyecciones Intravenosas , Lípidos/sangre , Lípidos/química , Masculino , Ratones , Ratones Endogámicos , Nanopartículas/química , ARN Interferente Pequeño/sangre , ARN Interferente Pequeño/química , ARN Interferente Pequeño/farmacocinética , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Distribución Tisular , Tritio , Recuento Corporal Total
19.
Bioanalysis ; 5(17): 2137-45, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23829464

RESUMEN

BACKGROUND: In the framework of wider exploration of the application of dried blood spots (DBS) in bioanalysis, by the DBS consortium of the European Bioanalytical Forum, one team of five laboratories investigated the merits of the various ways of IS addition prior to LC-MS/MS analysis. A set of 22 pharmaceutical compounds with log P in the range of 0-10 was selected for this purpose. Assessments were made of precision, recovery, and of the effects of prolonged storage. RESULTS: Assay precision was not significantly different for 3 month-aged samples as compared with 'fresh' samples stored for 7-22 days. Extraction recovery from 3 month-aged spots decreased for some of the analytes; the most widely employed addition of IS in the extraction solvent does not compensate for recovery in such cases. CONCLUSION: From the overall results, it is clear that there is no 'one size fits all' approach to IS addition in DBS bioanalysis.


Asunto(s)
Pruebas con Sangre Seca/normas , Manejo de Especímenes/normas , Animales , Europa (Continente) , Humanos , Asociaciones de Práctica Independiente , Metanol , Ratas , Reproducibilidad de los Resultados , Microextracción en Fase Sólida , Solventes , Espectrometría de Masas en Tándem , Factores de Tiempo
20.
Bioorg Med Chem ; 21(17): 4904-13, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23896611

RESUMEN

A series of new deoxyamodiaquine-based compounds was synthesized via the modified TMSN3-Ugi multi-component reaction and evaluated in vitro for antiplasmodial activity. The most potent compounds, 6b, 6c and 6j, showed IC50 values in the range of 6-77nM against chloroquine-resistant K1- and W2-strains of Plasmodium falciparum. In vitro ADME characterization of frontrunner compounds 6b and 6c indicates that these two compounds are rapidly metabolized and have a high clearance rate in human and rat liver microsomes. This result correlated well with an in vivo pharmacokinetics study, which showed low bioavailability of 6c in rats. Tentative metabolite identification was determined by LC-MS and suggested metabolic lability of groups attached to the tertiary nitrogen. Preliminary studies on 6b and 6c suggested strong inhibitory activity against the major CYP450 enzymes. In silico docking studies were used to rationalize strong inhibition of CYP3A4 by 6c. Full characterization and biological evaluation of the metabolites is currently underway in our laboratories.


Asunto(s)
Aminoquinolinas/síntesis química , Amodiaquina/análogos & derivados , Antimaláricos/síntesis química , Tetrazoles/química , Tetrazoles/síntesis química , Aminoquinolinas/farmacocinética , Aminoquinolinas/toxicidad , Amodiaquina/farmacocinética , Amodiaquina/toxicidad , Animales , Antimaláricos/farmacocinética , Antimaláricos/toxicidad , Sitios de Unión , Células CHO , Supervivencia Celular/efectos de los fármacos , Cricetinae , Cricetulus , Citocromo P-450 CYP3A/metabolismo , Inhibidores del Citocromo P-450 CYP3A , Resistencia a Medicamentos/efectos de los fármacos , Semivida , Humanos , Microsomas Hepáticos/metabolismo , Simulación del Acoplamiento Molecular , Plasmodium falciparum/efectos de los fármacos , Estructura Terciaria de Proteína , Ratas , Relación Estructura-Actividad , Tetrazoles/farmacocinética , Tetrazoles/toxicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...