Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Dermatol ; 51(1): 56-61, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37804078

RESUMEN

Nevus lipomatosus cutaneous superficialis is a rare, benign hamartoma characterized by mature adipocyte proliferation in the dermis. It is frequently difficult to distinguish clinically from soft tissue tumors, including lipoma, neurofibroma, venous malformation, and angiolipoma. Notably, the classical form, which shows multiple and sometimes enlarged nodules, is difficult to differentiate from liposarcoma based on clinical examination, computed tomography, and magnetic resonance imaging findings. Therefore, to ascertain the utility of ultrasonography in diagnosing nevus lipomatosus cutaneous superficialis, sonographic examinations were performed on eight patients with nevus lipomatosus cutaneous superficialis. All patients had ill-defined hyperechoic masses in the dermis or from the dermis to the subcutis, and the posterior echoes were attenuated in seven patients. Color Doppler sonography revealed no blood flow to the lesions. Ultrasound images were created using the reflections of ultrasound waves at interfaces with different acoustic impedances. Therefore, it is assumed that, in nevus lipomatosus cutaneous superficialis, the ultrasound beam is scattered by ectopic mature adipocytes intermingled with collagen bundles, which are shown as hyperechoic masses. Furthermore, the scattering of the ultrasound beam is thought to reduce tissue penetration, which may attenuate the posterior echo.


Asunto(s)
Hamartoma , Lipomatosis , Nevo , Neoplasias Cutáneas , Neoplasias de los Tejidos Blandos , Humanos , Lipomatosis/diagnóstico por imagen , Lipomatosis/patología , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Hamartoma/diagnóstico por imagen , Hamartoma/patología , Nevo/diagnóstico por imagen , Nevo/patología
4.
J Gastroenterol ; 57(4): 309-321, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35220490

RESUMEN

BACKGROUND: Ultrasonography (US) is widely used for the diagnosis of liver tumors. However, the accuracy of the diagnosis largely depends on the visual perception of humans. Hence, we aimed to construct artificial intelligence (AI) models for the diagnosis of liver tumors in US. METHODS: We constructed three AI models based on still B-mode images: model-1 using 24,675 images, model-2 using 57,145 images, and model-3 using 70,950 images. A convolutional neural network was used to train the US images. The four-class liver tumor discrimination by AI, namely, cysts, hemangiomas, hepatocellular carcinoma, and metastatic tumors, was examined. The accuracy of the AI diagnosis was evaluated using tenfold cross-validation. The diagnostic performances of the AI models and human experts were also compared using an independent test cohort of video images. RESULTS: The diagnostic accuracies of model-1, model-2, and model-3 in the four tumor types are 86.8%, 91.0%, and 91.1%, whereas those for malignant tumor are 91.3%, 94.3%, and 94.3%, respectively. In the independent comparison of the AIs and physicians, the percentages of correct diagnoses (accuracies) by the AIs are 80.0%, 81.8%, and 89.1% in model-1, model-2, and model-3, respectively. Meanwhile, the median percentages of correct diagnoses are 67.3% (range 63.6%-69.1%) and 47.3% (45.5%-47.3%) by human experts and non-experts, respectively. CONCLUSION: The performance of the AI models surpassed that of human experts in the four-class discrimination and benign and malignant discrimination of liver tumors. Thus, the AI models can help prevent human errors in US diagnosis.


Asunto(s)
Inteligencia Artificial , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Redes Neurales de la Computación , Ultrasonografía
5.
Biology (Basel) ; 10(9)2021 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-34571777

RESUMEN

Computed tomography (CT) is the standard method to evaluate Lipiodol deposition after transarterial embolization (TAE) for a long period. However, iodine but not Lipiodol can be observed on CT. A minimally invasive other method to detect Lipiodol has been needed to evaluate accurate evaluation after procedure. The purpose of this study was to evaluate the efficacy of using the rate of change in sound velocity caused by ultrasonic heating to reflect Lipiodol accumulation after TAE in a rat liver tumor model. We analyzed the association of this developed technique with CT images and histological findings. Eight rats bearing N1S1 cells were prepared. After confirmation of tumor development in a rat liver, Lipiodol was injected via the hepatic artery. Seven days after TAE, CT scan and sound velocity changes caused by ultrasonic heating were measured, and then the rats were sacrificed. An ultrasonic pulse-echo method was used to measure the sound velocity. The temperature coefficient of the sound velocity in each treated tumor was evaluated and compared with the mean CT value and the histological Lipiodol accumulation ratio. Pearson's correlation coefficients were calculated to assess the correlation between the measured values. The correlation coefficient (r) of the mean CT value and histological Lipiodol accumulation ratio was 0.835 (p = 0.010), which was considered statistically significant. Also, those of the temperature coefficient of the sound velocity and the histological Lipiodol accumulation ratio were statistically significant (r = 0.804; p = 0.016). To our knowledge, this is the first study that reported the efficacy of ultrasonic heating to detect Lipiodol accumulation in rat liver tumors after TAE. Our results suggest that the rate of change in sound velocity caused by ultrasonic heating can be used to evaluate Lipiodol accumulation in liver tumors after TAE, and thus could represent an alternative to CT in this application. This new innovative technique is easy to treat and less invasive in terms of avoiding radiation compared with CT.

6.
J Clin Imaging Sci ; 11: 15, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33767907

RESUMEN

OBJECTIVES: The objective of the study is to determine a parameter on the time-intensity curve (TIC) of dynamic contrast-enhanced ultrasonography (DCE-US) that best correlates with tumor growth and to evaluate whether the parameter could correlate with the early response to irinotecan in a rat liver tumor model. MATERIAL AND METHODS: Twenty rats with tumors were evaluated (control: Saline, n = 6; treatment: Irinotecan, n = 14) regarding four parameters from TIC: Peak intensity (PI), k value, slope (PI × k), and time to peak (TTP). Relative changes in maximum tumor diameter between day 0 and 10, and parameters in the first 3 days were evaluated. The Mann-Whitney U-test was used to compare differences in tumor size and other parameters. Pearson's correlation coefficients (r) between tumor size and parameters in the control group were calculated. In the treatment group, relative changes of parameters in the first 3 days were compared between responder and non-responder (<20% and ≥20% increase in size on day 10, respectively). RESULTS: PI, k value, PI × k, and TTP significantly correlated with tumor growth (r = 0.513, 0.911, 0.665, and 0.741, respectively). The mean RC in k value among responders (n = 6) was significantly lower than non-responders (n = 8) (mean k value, 4.96 vs. 72.5; P = 0.003). CONCLUSION: Parameters of DCE-US could be a useful parameter for identifying early response to irinotecan.

7.
Breast Cancer ; 28(2): 405-413, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33119842

RESUMEN

BACKGROUND: To prove the efficacy of contrast-enhanced ultrasound (CEUS) in determining the extent of resection, more evidence about B-mode and CEUS as opposed to pathology is required. We compared maximum tumor width measured on B-mode/CEUS images with that determined pathologically. METHODS: In this retrospective multicenter study, 152 operable breast cancer patients who had undergone both B-mode and CEUS were analyzed. Maximum tumor width on B-mode and CEUS, and on the postoperative pathological examination (P), was measured by the participating investigators. In addition, maximum width was assessed in B-mode and CEUS image sets by independent reviewers blinded to all patient information. We analyzed differences in maximum width between CEUS, B-mode and P. RESULTS: The mean widths as measured by the participating investigators were 15 ± 7 mm (B-mode), 19 ± 8 mm (CEUS), and 17 ± 9 mm (P). The difference subtracted P from B-mode was - 3 ± 7 mm (p < 0.0001), and that from CEUS was 1 ± 6 mm (p = 0.0163). The mean widths as measured by the independent reviewers were 16 ± 7 mm (B-mode) and 18 ± 7 mm (CEUS). The difference subtracted P from B-mode was - 2 ± 8 mm (p = 0.0114), while that from CEUS was 1 ± 7 mm (p = 0.1921). CONCLUSIONS: Maximum lesion width measurement showed a tendency to increase in the order of B-mode, to P and CEUS. The difference in measurement between P and B-mode was significant, but there was no significant between CEUS and P. These results provide additional information of tendency patterns in measuring the maximum lesion width through enhancement on CEUS.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Medios de Contraste , Carga Tumoral , Ultrasonografía Mamaria/métodos , Anciano , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Japón/epidemiología , Mastectomía , Persona de Mediana Edad , Estudios Retrospectivos
8.
J Med Ultrason (2001) ; 47(4): 591-601, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32989596

RESUMEN

PURPOSE: The objective of this study was to retrospectively evaluate the association between background parenchymal enhancement (BPE) on contrast-enhanced ultrasound (CEUS) with Sonazoid® and patient characteristics. Additionally, background parenchymal tissues with the high-contrast effect were pathologically observed compared to those showing the low-contrast effect. METHODS: A total of 65 patients who underwent breast CEUS with Sonazoid® between January 2010 and November 2013 were enrolled. Regions of interest (ROIs) were put on the tumor and on the background parenchymal tissue. The dB values during the nonenhanced time and at peak contrast enhancement were measured based on the time intensity curve (TIC) drawn by the ROI. The differences in the dB values of pre- and post-enhanced time were obtained separately for ROIs on the tumor and ROIs on the parenchymal tissue. The patient characteristics studied were age, menstrual status, mammographic density, BPE on magnetic resonance imaging (MRI), and pathological diagnoses of breast tumors. RESULTS: There was a weak negative correlation between BPE on CEUS and age. As for the contrast effect of parenchymal tissue, there was a significant difference between the menstruating and menopausal groups. There was no significant difference among the levels of mammographic density, and among the degrees of contrast effect on MRI. BPE on CEUS was the same between those with a malignant tumor and those with a benign tumor in each menstrual status. The parenchymal tissue with the low-contrast effect showed pathological atrophy. CONCLUSION: The degree of BPE on CEUS appeared related to age, menstruating or menopausal, and atrophy of breast tissue. BPE on CEUS was the same between those with a malignant tumor and those with a benign tumor in each menstrual status.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Compuestos Férricos , Aumento de la Imagen/métodos , Hierro , Óxidos , Tejido Parenquimatoso/diagnóstico por imagen , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Mama/patología , Densidad de la Mama , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Tejido Parenquimatoso/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
9.
Hepatol Res ; 50(11): 1297-1305, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32822527

RESUMEN

AIM: To compare two different embolic materials, water-in-oil (W/O) emulsion followed by gelatin particles and microspheres in transarterial embolization (TAE), using a rat hepatocellular carcinoma model. METHODS: Twenty rats bearing N1S1 cells were divided into the W/O emulsion group and Microsphere group. Water-in-oil emulsion was created by a glass membrane emulsification device. The tumor vascularity was measured by contrast-enhanced ultrasonography 24 h before and 10 min and 48 h after TAE. Tumor necrosis, hepatic infarction ratio surrounding the tumor, and locations of the embolic materials 48 h after TAE were assessed. The changes of serum liver enzymes were also evaluated. Statistical significance was determined by using either the Mann-Whitney U-test or Fisher's exact test. RESULTS: The tumor vascularity 48 h after TAE was significantly higher in the Microsphere group (20.1 vs. 3.76%, P = 0.016). The overflow of Lipiodol into the portal veins surrounding the tumor was seen, whereas microspheres were seen only in the artery. The percentage of necrotic area and complete response ratio in the W/O emulsion group was significantly higher (99.9 vs. 87.6%, P = 0.029 and 87.5 vs. 28.6%, P = 0.041, respectively). Serum aspartate aminotransferase and serum alanine aminotransferase levels 48 h after TAE were significantly higher in the W/O emulsion group (P < 0.01). CONCLUSIONS: The embolization using W/O emulsion followed by gelatin particles showed stronger antitumor effects with the occlusion of both the tumor feeding artery and the portal vein compared with microspheres, which occluded only the arteries.

10.
Abdom Radiol (NY) ; 45(7): 2263-2267, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32060612

RESUMEN

We report a case of uterine adenomatoid tumor (AT) with regional lymph node involvement in a 49-year-old woman. Magnetic resonance imaging revealed an aggregated cystic mass in the posterior uterine wall with partial protrusion of the tumor outside the uterus, and cystic masses of same characteristics in the bilateral obturator and right common iliac lymph nodes. FDG PET/CT revealed no significant FDG uptake in the uterine and lymph node lesions. Taking possible lymph node metastasis into consideration, hysterectomy and lymph node biopsy were performed and it revealed AT of the uterus and the lymph nodes histopathologically.


Asunto(s)
Tumor Adenomatoide , Tumor Adenomatoide/diagnóstico por imagen , Tumor Adenomatoide/cirugía , Femenino , Fluorodesoxiglucosa F18 , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Metástasis Linfática/diagnóstico por imagen , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Útero
11.
Ann Vasc Dis ; 12(3): 319-322, 2019 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-31636740

RESUMEN

Abdominal aortic aneurysms (AAAs) are life-threatening and are associated with >80% mortality when they rupture. Therefore, detecting these aneurysms before they rupture is critical. Ultrasonography is a non-invasive tool that is used for screening AAAs by measuring abdominal aorta diameter. A recent meta-analysis demonstrated the positive effects of ultrasonography. To date, aneurysm diameter is the most reliable predictor for aneurysm rupture and is used as a criterion for surgical intervention. However, some AAAs rupture at small diameters. Therefore, a better predictor for AAA rupture that is independent of aneurysm diameter is needed. Recently, an aortic wall strain examined using ultrasonography has been reported to have a potential in predicting AAA rupture. Since the introduction of endovascular aneurysm repair (EVAR), a paradigm shift has occurred in the management of AAAs. EVAR is broadly spread with the advantage of early favorable results but with concerning endoleak complications. At present, computed tomography angiography (CTA) is considered to be a gold standard for surveillance following EVAR, but it encounters some problems, such as contrast usage or radiation exposure. Ultrasonography offers an examination free from these problems and can this be an alternative to CTA. In this review article, current trends and new technologies regarding AAA assessment using ultrasonography are introduced.

12.
Anticancer Res ; 39(8): 4249-4252, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31366513

RESUMEN

BACKGROUND/AIM: Video-assisted thoracic surgery (VATS) for ipsilateral reoperations is challenging because of the potential for pleural adhesions. Insertion of the initial port can lead to lung injury because of the blinded intrathoracic area. We assessed the usefulness of ultrasonography before VATS to reduce the incidence of lung injury at the time of the initial port insertion during secondary ipsilateral VATS. PATIENTS AND METHODS: Thirty-three patients who underwent repeat VATS for ipsilateral pulmonary lesions were included. All patients underwent preoperative ultrasonography to assess the possible presence of pleural adhesions using the lung sliding sign. RESULTS: Seven adhesions were found at the VATS ports. Two of these adhesions were not evaluated as pleural adhesions using ultrasonography; however, they were loose. All initial ports were inserted without lung injury. There were no major complications. CONCLUSION: Preoperative detection of pleural adhesions using ultrasonography can determine the best initial port for secondary ipsilateral VATS.


Asunto(s)
Enfermedades Pleurales/cirugía , Cirugía Torácica Asistida por Video , Cirugía Torácica/métodos , Ultrasonografía , Adulto , Anciano , Femenino , Humanos , Pulmón/fisiopatología , Pulmón/cirugía , Lesión Pulmonar/fisiopatología , Lesión Pulmonar/cirugía , Masculino , Persona de Mediana Edad , Enfermedades Pleurales/fisiopatología , Cuidados Preoperatorios , Toracotomía , Adherencias Tisulares/fisiopatología
13.
Kyobu Geka ; 72(8): 567-569, 2019 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-31353345

RESUMEN

Recently, there has been an increase in the experience of lung surgery in cases with a history of thoracotomy or pneumonia. In these cases, pleural adhesion is often seen and makes the surgery to be difficult. Especially in thoracoscopic surgery, lung damage must be care at the 1st port insertion. In this report, the usefulness of the extent of pleural adhesion to the chest wall before surgery by using a transthoracic ultrasonography was assessed. Between April 2017 and September 2018, 32 patients underwent preoperative ultrasound examination, and 128 ports were evaluated whether had adhesions or not using lung sliding sign. All patients of 128, 24 adhesions were found at surgery, resulting in 14 true positive, 10 false negative, 0 false positive, and 104 true negative findings [sensitivity:58.3% (14/24), specificity: 100.0% (104/104), accuracy:92.2% (118/128)]. Especially, about the 1st port, accuracy was 93.8 % (30/32). In Conclusion, preoperative transthoracic ultrasonography could provide useful information on the pleural adhesion leading safe initial thoracoscopic access without lung injury.


Asunto(s)
Enfermedades Pleurales , Ultrasonografía , Humanos , Sensibilidad y Especificidad , Toracoscopía , Toracotomía
14.
In Vivo ; 33(3): 973-978, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31028224

RESUMEN

BACKGROUND/AIM: Aspirin reduces cardiovascular disease and/or stroke risks. However, perioperative aspirin use remains controversial. We assessed the efficacy of ultrasonography to facilitate video-assisted thoracic surgery (VATS). We analyzed the perioperative management of patients using aspirin and its association with bleeding events during lung cancer surgery. PATIENTS AND METHODS: A total of 38 patients who underwent VATS after continuing or discontinuing aspirin were examined. Ultrasound was performed preoperatively to evaluate the pleural adhesions. Fisher's exact test was used to analyze correlations between the two groups. RESULTS: Dense adhesions were found at VATS ports using ultrasonography (accuracy: 100%). No differences were detected in bleeding, thrombotic events, or operative times between the aspirin and non-aspirin groups. There were differences in bleeding (p=0.009) and operative times (p=0.021) between the dense adhesion and non-dense adhesion groups. CONCLUSION: Preoperative detection of pleural adhesions using ultrasonography was useful in selecting pulmonary resection patients who continued aspirin perioperatively.


Asunto(s)
Adherencias Tisulares/diagnóstico por imagen , Ultrasonografía , Anciano , Aspirina/administración & dosificación , Femenino , Humanos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Neumonectomía/efectos adversos , Adherencias Tisulares/etiología , Ultrasonografía/métodos
15.
Jpn J Radiol ; 36(7): 429-436, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29728922

RESUMEN

PURPOSE: The purpose of this study was to identify the magnetic resonance imaging (MRI) features of uterine endometrial carcinoma (EC) with DNA mismatch repair (MMR) deficiency. MATERIALS AND METHODS: This was a retrospective study approved by our institutional review board. The study included 118 patients pathologically diagnosed as having EC in our institution from April 2014 to December 2016. Of 118 patients, 8 were excluded because of insufficient data. Immunohistochemical analysis of MMR was performed retrospectively to observe the expressions of MLH1, MSH2, MSH6, and PMS2. A tumor with MMR deficiency was detected in 17 of 110 cases (15%). Clinical background characteristics and MRI findings were reviewed. These findings were compared between MMR deficiency group and the other group as a control group. Statistical significance was determined using the Fisher's exact test and the Mann-Whitney U test, as appropriate. RESULTS: The clinical background characteristics of patients with EC with MMR deficiency were not significantly different from those of other patients. On MRI, the tumor was significantly more often located in the lower uterine site (MMR(-) vs. MMR(+): 29.4 vs. 8.9% [p = 0.0366]). CONCLUSION: EC with MMR deficiency tends to be located lower in the uterus, though most other findings were not significantly different from those of EC without MMR deficiency.


Asunto(s)
Neoplasias Endometriales/diagnóstico por imagen , Neoplasias Endometriales/genética , Imagen por Resonancia Magnética/métodos , Homólogo 1 de la Proteína MutL/deficiencia , Adulto , Anciano , Endometrio/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Homólogo 1 de la Proteína MutL/genética , Estudios Retrospectivos
17.
Cardiovasc Intervent Radiol ; 40(3): 438-444, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27872985

RESUMEN

PURPOSE: The purpose of this study is to evaluate the pharmacokinetics and histopathological findings of transarterial chemoembolization (TACE) using cisplatin powder mixed with degradable starch microspheres (DSM) (Cis/DSM-TACE) compared with cisplatin arterial infusion (Cis-AI). MATERIALS AND METHODS: Eighteen rabbits with VX2 liver tumors were divided into two groups: Cis/DSM-TACE (n = 9) and Cis-AI (n = 9) groups. In the Cis/DSM-TACE group, a mixture of cisplatin powder and DSM was injected until stasis of hepatic arterial flow was achieved. In the Cis-AI group, cisplatin solution was infused. RESULTS: The platinum concentrations in VX2 tumors in the Cis/DSM-TACE group at 24 and 72 h were significantly elevated compared with those in the Cis-AI group (P = .016 and .019, respectively). There were no significant differences in the platinum concentrations in plasma. Histopathological examination revealed the presence of several microspheres inside the tumors at 1 h, which completely disappeared at 24 h. Tumor cell apoptosis at 1 h in the Cis/DSM-TACE group was more frequently observed compared with that in the Cis-AI group (P = .006). CONCLUSIONS: TACE using cisplatin powder mixed with DSM provides a higher drug concentration in tumors, thereby achieving stronger antitumor effects compared with arterial infusion of cisplatin solution.


Asunto(s)
Quimioembolización Terapéutica/métodos , Cisplatino/administración & dosificación , Cisplatino/farmacocinética , Neoplasias Hepáticas Experimentales/sangre , Neoplasias Hepáticas Experimentales/terapia , Neoplasias Hepáticas/sangre , Neoplasias Hepáticas/terapia , Almidón , Animales , Relación Dosis-Respuesta a Droga , Arteria Hepática , Infusiones Intraarteriales , Neoplasias Hepáticas/patología , Neoplasias Hepáticas Experimentales/patología , Microesferas , Polvos , Conejos
18.
J Med Ultrason (2001) ; 43(2): 227-35, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26801662

RESUMEN

PURPOSE: To prospectively evaluate the usefulness of contrast-enhanced ultrasound (CEUS) using parametric imaging for breast cancer in a multicenter study. METHODS: A total of 65 patients with breast cancer were included in this study. CEUS was performed, and still images on peak time (S), accumulated images (A) and parametric images (P) were generated from the raw data. Four blind reviewers ranked the best visible images as first place, and determined second and third place consecutively. We compared the average ranking of each image. The maximal diameter of the tumor determined on ultrasonography and MRI was compared with the corresponding pathological maximal diameter for 48 of the 65 patients. The correlation between the diameter determined by two experts and two beginners was analyzed. RESULTS: The average rank of visibility was as follows: P, 1.44; A, 2.04; and S, 2.52. The correlation between each image and the pathology was as follows: P, r = 0.664; A, r = 0.630; S, r = 0.717; and MRI, r = 0.936. There were no significant differences among the correlation between the experts and beginners in each image. CONCLUSIONS: The use of parametric imaging improves the visibility of CEUS. The maximal diameter of the tumor determined on CEUS correlates substantially with the pathology.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Carcinoma/diagnóstico por imagen , Medios de Contraste , Compuestos Férricos , Hierro , Óxidos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Carcinoma/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Método Simple Ciego , Carga Tumoral
19.
Int J Gynaecol Obstet ; 132(1): 42-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26442455

RESUMEN

OBJECTIVE: To evaluate a sequential screening method's efficacy in predicting symptomatic pulmonary thromboembolism (PTE) after gynecologic surgery. METHODS: A prospective study employing a two-stage screening process was conducted among consecutive asymptomatic adults who underwent outpatient evaluation for gynecologic surgery at Nara Medical University Hospital, Japan, between April 1, 2004, and December 31, 2013. Patients with a preoperative plasma D-dimer level greater than or equal to 1.0µg/mL underwent compression ultrasonography of the lower extremities. The primary outcome measure was postoperative detection of symptomatic PTE. RESULTS: Overall, 1729 patients were included. The mean D-dimer level was 1.7±3.3µg/mL. Compression ultrasonography was conducted among 470 (27.1%) patients with positive D-dimer test results; symptomatic deep vein thrombosis (DVT) was preoperatively detected among 94 (20.0%) of them. Patients with DVT (n=94) had higher D-dimer levels than patients (n=1635) without (7.8±12.8µg/mL vs 1.1±1.8µg/mL; P<0.001). Despite anticoagulant therapy, symptomatic PTE was detected postoperatively among two of these 94 patients. Symptomatic PTE was also detected among four of 376 patients with positive D-dimer test results but no evidence of DVT by ultrasonography. No clinical onset of postoperative PTE was observed among 1259 patients with D-dimer levels below the cut-off value. CONCLUSION: The PROVEN screening strategy (Preoperative surveillance using a sequential strategy) was ineffective at predicting postoperative symptomatic PTE.


Asunto(s)
Procedimientos Quirúrgicos Ginecológicos , Tamizaje Masivo/métodos , Cuidados Preoperatorios/métodos , Embolia Pulmonar/sangre , Embolia Pulmonar/diagnóstico por imagen , Adulto , Anciano , Anticoagulantes/uso terapéutico , Biomarcadores/sangre , Femenino , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Humanos , Japón , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/diagnóstico por imagen , Persona de Mediana Edad , Periodo Posoperatorio , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Ultrasonografía , Trombosis de la Vena/sangre , Trombosis de la Vena/diagnóstico por imagen
20.
Jpn J Radiol ; 33(10): 636-44, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26251239

RESUMEN

PURPOSE: To investigate the correlation between ABC risk assessment and radiological findings of gastric mucosa and to propose an improved method for gastric cancer screening. MATERIALS AND METHODS: We evaluated 318 participants with Helicobacter pylori (Hp) antibody titers, serum pepsinogen (PG) and upper GI radiography and then classified them into three groups: A, double-negative; B, Hp-positive, PG-negative; C, PG-positive. Group A was subclassified as: A-1, Hp antibody titer <3.0 U/ml; A-2, Hp antibody titer ≥3.0 U/ml. Results for group A and non-A (B or C) participants and radiological findings of gastric mucosa (fold and area gastricae) were analyzed retrospectively. RESULTS: Radiological findings differed significantly between the 207 A-1 and 98 non-A group. Odds ratios were 17.72 for fold distribution, 10.63 for fold thickness, 6.10 for fold characteristics, and 10.62 for area gastricae. Presence of ≥2 risk factors offered 90.3 % sensitivity, 94.7 % specificity, and 93.3 % accuracy. Nine (69.2 %) of the 13 A-2 group participants and 11 (5.3 %) A-1 group participants had a risk for gastric cancer according to radiological findings. CONCLUSION: A good correlation exists between ABC classifications and radiological findings for gastric cancer risk, but some discrepant cases exist. We recommend both methods as screening for gastric cancer.


Asunto(s)
Detección Precoz del Cáncer/métodos , Mucosa Gástrica/diagnóstico por imagen , Neoplasias Gástricas/sangre , Neoplasias Gástricas/diagnóstico por imagen , Adulto , Anciano , Bario , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...