1.
Phys Med Biol ; 69(3)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38157551

RESUMEN

Objective. Time-dependent yields of chemical products resulting from water radiolysis play a great role in evaluating DNA damage response after exposure to ionizing radiation. Particle and Heavy Ion Transport code System (PHITS) is a general-purpose Monte Carlo simulation code for radiation transport, which simulates atomic interactions originating from discrete energy levels of ionizations and electronic excitations as well as molecular excitations as physical stages. However, no chemical code for simulating water radiolysis products exists in the PHITS package.Approach.Here, we developed a chemical simulation code dedicated to the PHITS code, hereafter calledPHITS-Chemcode, which enables the calculation of theGvalues of water radiolysis species (•OH, eaq-, H2, H2O2etc) by electron beams.Main results.The estimatedGvalues during 1 µs are in agreement with the experimental ones and other simulations. ThisPHITS-Chemcode also simulates the radiolysis in the presence of OH radical scavengers, such as tris(hydroxymethyl)aminomethane and dimethyl sulfoxide. Thank to this feature, the contributions of direct and indirect effects on DNA damage induction under various scavenging capacities can be analyzed.Significance.This chemical code coupled with PHITS could contribute to elucidating the mechanism of radiation effects by connecting physical, physicochemical, and chemical processes.


Asunto(s)
Electrones , Agua , Agua/química , Simulación por Computador , Fenómenos Químicos , Radiación Ionizante , Método de Montecarlo
2.
RSC Adv ; 13(46): 32371-32380, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37928859

RESUMEN

This study uses a time-dependent first-principles simulation code to investigate the transient dynamics of an ejected electron produced in the monochromatic deposition energy from 11 to 19 eV in water. The energy deposition forms a three-body single spur comprising a hydroxyl radical (OH˙), hydronium ion (H3O+), and hydrated electron (eaq-). The earliest formation involves electron thermalization and delocalization dominated by the molecular excitation of water. Our simulation results show that the transient electron dynamics primarily depends on the amount of deposition energy to water; the thermalization time varies from 200 to 500 fs, and the delocalization varies from 3 to 10 nm in this energy range. These features are crucial for determining the earliest single-spur formation and facilitating a sequential simulation from an energy deposition to a chemical reaction in water photolysis or radiolysis. The spur radius obtained from the simulation correlates reasonably with the experimental-based estimations. Our results should provide universalistic insights for analysing ultrafast phenomena dominated by the molecular excitation of water in the femtosecond order.

3.
Phys Med Biol ; 68(15)2023 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-37352865

RESUMEN

Objective. Estimation of the probability density of the microdosimetric quantities in macroscopic matter is indispensable for applying the concept of microdosimetry to medical physics and radiological protection. The Particle and Heavy Ion Transport code System (PHITS) enables estimating the microdosimetric probability densities due to its unique hybrid modality between the Monte Carlo and analytical approaches called the microdosimetric function. It can convert the deposition energies calculated by the macroscopic Monte Carlo radiation transport simulation to microdosimetric probability densities in water using an analytical function based on the track-structure simulations.Approach. In this study, we improved this function using the latest track-structure simulation codes implemented in PHITS. The improved function is capable of calculating the probability densities of not only the conventional microdosimetric quantities such as lineal energy but also the number of ionization events occurring in a target site, the so-called ionization cluster size distribution, for arbitrary site diameters from 3 nm to 1µm.Main results. The accuracy of the improved function was well verified by comparing the microdosimetric probability densities measured by tissue-equivalent proportional counters with the corresponding data calculated in this study. Test calculations for clonogenic cell survival using the improved function coupled with the modified microdosimetric kinetic model suggested a slight increase of its relative biological effectiveness compared with our previous estimations. As a new application of the improved function, we calculated the relative biological effectiveness of the single-strand break and double-strand break yields for proton irradiations using the updated PHITS coupled with the simplified DNA damage estimation model, and confirmed its equivalence in accuracy and its superiority in computational time compared to our previously proposed method based on the track-structure simulation.Significance. From these features, we concluded that the improved function could expand the application fields of PHITS by bridging the gap between microdosimetry and macrodosimetry.


Asunto(s)
Radiación Ionizante , Radiometría , Método de Montecarlo , Simulación por Computador , Efectividad Biológica Relativa , Probabilidad , Radiometría/métodos
4.
RSC Adv ; 13(11): 7076-7086, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36875880

RESUMEN

Many scientific insights into water radiolysis have been applied for developing life science, including radiation-induced phenomena, such as DNA damage and mutation induction or carcinogenesis. However, the generation mechanism of free radicals due to radiolysis remains to be fully understood. Consequently, we have encountered a crucial problem in that the initial yields connecting radiation physics to chemistry must be parameterized. We have been challenged in the development of a simulation tool that can unravel the initial free radical yields, from physical interaction by radiation. The presented code enables the first-principles calculation of low energy secondary electrons resulting from the ionization, in which the secondary electron dynamics are simulated while considering dominant collision and polarization effects in water. In this study, using this code, we predicted the yield ratio between ionization and electronic excitation from a delocalization distribution of secondary electrons. The simulation result presented a theoretical initial yield of hydrated electrons. In radiation physics, the initial yield predicted from parameter analysis of radiolysis experiments in radiation chemistry was successfully reproduced. Our simulation code helps realize a reasonable spatiotemporal connection from radiation physics to chemistry, which would contribute to providing new scientific insights for precise understanding of underlying mechanisms of DNA damage induction.

6.
Sci Rep ; 12(1): 16412, 2022 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-36180476

RESUMEN

Magnetic resonance-guided radiotherapy (MRgRT) has been developed and installed in recent decades for external radiotherapy in several clinical facilities. Lorentz forces modulate dose distribution by charged particles in MRgRT; however, the impact of Lorentz forces on low-energy electron track structure and early DNA damage induction remain unclear. In this study, we estimated features of electron track structure and biological effects in a static magnetic field (SMF) using a general-purpose Monte Carlo code, particle and heavy ion transport code system (PHITS) that enables us to simulate low-energy electrons down to 1 meV by track-structure mode. The macroscopic dose distributions by electrons above approximately 300 keV initial energy in liquid water are changed by both perpendicular and parallel SMFs against the incident direction, indicating that the Lorentz force plays an important role in calculating dose within tumours. Meanwhile, DNA damage estimation based on the spatial patterns of atomic interactions indicates that the initial yield of DNA double-strand breaks (DSBs) is independent of the SMF intensity. The DSB induction is predominantly attributed to the secondary electrons below a few tens of eV, of which energy deposition patterns are not considerably affected by the Lorentz force. Our simulation study suggests that treatment planning for MRgRT can be made with consideration of only changed dose distribution.


Asunto(s)
Daño del ADN , Electrones , ADN/química , Espectroscopía de Resonancia Magnética , Método de Montecarlo , Agua/química
7.
Int J Radiat Biol ; 98(2): 148-157, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34930091

RESUMEN

PURPOSE: In radiation physics, Monte Carlo radiation transport simulations are powerful tools to evaluate the cellular responses after irradiation. When investigating such radiation-induced biological effects, it is essential to perform track structure simulations by explicitly considering each atomic interaction in liquid water at the sub-cellular and DNA scales. The Particle and Heavy-Ion Transport code System (PHITS) is a Monte Carlo code which enables to calculate track structure at DNA scale by employing the track-structure modes for electrons, protons and carbon ions. In this paper, we review the recent development status and future prospects of the track-structure modes in the PHITS code. CONCLUSIONS: To date, the physical features of these modes have been verified using the available experimental data and Monte Carlo simulation results reported in literature. These track-structure modes can be used for calculating microdosimetric distributions to estimate cell survival and for estimating initial DNA damage yields. The use of PHITS track-structure mode is expected not only to clarify the underlying mechanisms of radiation effects but also to predict curative effects in radiation therapy. The results of PHITS simulations coupled with biophysical models will contribute to the radiobiological studies by precisely predicting radiation-induced biological effects based on the Monte Carlo approach.


Asunto(s)
Iones Pesados , Simulación por Computador , ADN , Transporte Iónico , Método de Montecarlo , Radiobiología
8.
Sci Rep ; 11(1): 24401, 2021 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-34934066

RESUMEN

A novel transport algorithm performing proton track-structure calculations in arbitrary materials was developed. Unlike conventional algorithms, which are based on the dielectric function of the target material, our algorithm uses a total stopping power formula and single-differential cross sections of secondary electron production. The former was used to simulate energy dissipation of incident protons and the latter was used to consider secondary electron production. In this algorithm, the incident proton was transmitted freely in matter until the proton produced a secondary electron. The corresponding ionising energy loss was calculated as the sum of the ionisation energy and the kinetic energy of the secondary electron whereas the non-ionising energy loss was obtained by subtracting the ionising energy loss from the total stopping power. The most remarkable attribute of this model is its applicability to arbitrary materials, i.e. the model utilises the total stopping power and the single-differential cross sections for secondary electron production rather than the material-specific dielectric functions. Benchmarking of the stopping range, radial dose distribution, secondary electron energy spectra in liquid water, and lineal energy in tissue-equivalent gas, against the experimental data taken from literature agreed well. This indicated the accuracy of the present model even for materials other than liquid water. Regarding microscopic energy deposition, this model will be a robust tool for analysing the irradiation effects of cells, semiconductors and detectors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...