Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Respir Res ; 25(1): 251, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902707

RESUMEN

BACKGROUND: The impact of chronic obstructive pulmonary disease (COPD) on outcome in perioperative organ injury (POI) has not yet been investigated sufficiently. METHODS: This retrospective cohort study analysed data of surgical patients with POI, namely delirium, stroke, acute myocardial infarction, acute respiratory distress syndrome, acute liver injury (ALI), or acute kidney injury (AKI), in Germany between 2015 and 2019. We compared in-hospital mortality, hospital length of stay (HLOS) and perioperative ventilation time (VT) in patients with and without COPD. RESULTS: We analysed the data of 1,642,377 surgical cases with POI of which 10.8% suffered from COPD. In-hospital mortality was higher (20.6% vs. 15.8%, p < 0.001) and HLOS (21 days (IQR, 12-34) vs. 16 days (IQR, 10-28), p < 0.001) and VT (199 h (IQR, 43-547) vs. 125 h (IQR, 32-379), p < 0.001) were longer in COPD patients. Within the POI examined, AKI was the most common POI (57.8%), whereas ALI was associated with the highest mortality (54.2%). Regression analysis revealed that COPD was associated with a slightly higher risk of in-hospital mortality (OR, 1.19; 95% CI:1.18-1.21) in patients with any POI. CONCLUSIONS: COPD in patients with POI is associated with higher mortality, longer HLOS and longer VT. Especially patients suffering from ALI are susceptible to the detrimental effects of COPD on adverse outcome.


Asunto(s)
Mortalidad Hospitalaria , Complicaciones Posoperatorias , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Estudios Retrospectivos , Masculino , Femenino , Alemania/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Anciano , Mortalidad Hospitalaria/tendencias , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/epidemiología , Estudios de Cohortes , Anciano de 80 o más Años , Tiempo de Internación/estadística & datos numéricos , Tiempo de Internación/tendencias , Resultado del Tratamiento , Factores de Riesgo
2.
Bioengineering (Basel) ; 11(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38790323

RESUMEN

The survival rate of cardiac arrest (CA) can be improved by utilizing percutaneous left ventricular assist devices (pLVADs) instead of conventional chest compressions. However, existing pLVADs require complex fluoroscopy-guided placement along a guidewire and suffer from limited blood flow due to their cross-sectional area. The recently developed self-expandable Impella CP (ECP) pLVAD addresses these limitations by enabling guidewire-free placement and increasing the pump cross-sectional area. This study evaluates the feasibility of resuscitation using the Impella ECP in a swine CA model. Eleven anesthetized pigs (73.8 ± 1.7 kg) underwent electrically induced CA, were left untreated for 5 min and then received pLVAD insertion and activation. Vasopressors were administered and defibrillations were attempted. Five hours after the return of spontaneous circulation (ROSC), the pLVAD was removed, and animals were monitored for an additional hour. Hemodynamics were assessed and myocardial function was evaluated using echocardiography. Successful guidewire-free pLVAD placement was achieved in all animals. Resuscitation was successful in 75% of cases, with 3.5 ± 2.0 defibrillations and 1.8 ± 0.4 mg norepinephrine used per ROSC. Hemodynamics remained stable post-device removal, with no adverse effects or aortic valve damage observed. The Impella ECP facilitated rapid guidewire-free pLVAD placement in fibrillating hearts, enabling successful resuscitation. These findings support a broader clinical adoption of pLVADs, particularly the Impella ECP, for CA.

3.
J Clin Med ; 13(5)2024 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-38592678

RESUMEN

(1) Background: Patients' comorbidities play an immanent role in perioperative risk assessment. It is unknown how Charlson Comorbidity Indices (CCIs) from different sources compare. (2) Methods: In this prospective observational study, we compared the CCIs of patients derived from patients' self-reports and from physicians' assessments with hospital administrative data. (3) Results: The data of 1007 patients was analyzed. Agreement between the CCI from patients' self-report compared to administrative data was fair (kappa 0.24 [95%CI 0.2-0.28]). Agreement between physicians' assessment and the administrative data was also fair (kappa 0.28 [95%CI 0.25-0.31]). Physicians' assessment and patients' self-report had the best agreement (kappa 0.33 [95%CI 0.30-0.37]). The CCI calculated from the administrative data showed the best predictability for in-hospital mortality (AUROC 0.86 [95%CI 0.68-0.91]), followed by equally good prediction from physicians' assessment (AUROC 0.80 [95%CI 0.65-0.94]) and patients' self-report (AUROC 0.80 [95%CI 0.75-0.97]). (4) Conclusions: CCIs derived from patients' self-report, physicians' assessments, and administrative data perform equally well in predicting postoperative in-hospital mortality.

4.
Sci Rep ; 14(1): 6044, 2024 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-38472246

RESUMEN

Chronic obstructive pulmonary disease (COPD) is one of the leading chronic diseases worldwide. However, the impact of COPD on outcome after percutaneous coronary intervention (PCI) remains unclear. In this retrospective cohort study, we analyzed the data of hospitalized patients undergoing PCI in Germany between 2015 and 2019. We compared in-hospital mortality, hospital length of stay and peri-interventional ventilation time (VT) in patients with and without COPD, including different COPD severity grades, COPD with exacerbation (COPDe) and infection (COPDi). We analyzed the data of 3,464,369 cases undergoing PCI. A total of 291,707 patients (8.4%) suffered from COPD. Patients suffering from COPD died more often (2.4% vs. 2.0%; p < 0.001), stayed longer hospitalized (5 days (2-10) vs. 3 days (1-6); p < 0.001), were more frequent (7.2% vs. 3.2%) and longer ventilated (26 h (7-88) vs. 23 h (5-92); p < 0.001). Surprisingly, COPD was associated with a 0.78-fold odds of in-hospital mortality and with reduced VT (- 1.94 h, 95% CI, - 4.34 to 0.43). Mild to severe COPD was associated with a lower risk of in-hospital mortality and reduced VT, whereas very severe COPD, COPDe and COPDi showed a higher risk of in-hospital mortality. We found a paradoxical association between mild to severe COPD and in-hospital mortality, whereas very severe COPD, COPDe and COPDi were associated with higher in-hospital mortality. Further investigations should illuminate, whether comorbidities affect these associations.


Asunto(s)
Intervención Coronaria Percutánea , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Estudios Retrospectivos , Mortalidad Hospitalaria , Factores de Riesgo
5.
J Clin Med ; 12(3)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36769640

RESUMEN

A noninvasive tool for cardiovascular risk stratification has not yet been established in the clinical routine analysis. Previous studies suggest a prolonged Tpeak-Tend interval (the interval from the peak to the end of the T-wave) to be predictive of death. This meta-analysis was designed to systematically evaluate the association of the Tpeak-Tend interval with mortality outcomes. Medline (via PubMed), Embase and the Cochrane Library were searched from 1 January 2008 to 21 July 2020 for articles reporting the ascertainment of the Tpeak-Tend interval and observation of all-cause-mortality. The search yielded 1920 citations, of which 133 full-texts were retrieved and 29 observational studies involving 23,114 patients met the final criteria. All-cause deaths had longer Tpeak-Tend intervals compared to survivors by a standardized mean difference of 0.41 (95% CI 0.23-0.58) and patients with a long Tpeak-Tend interval had a higher risk of all-cause death compared to patients with a short Tpeak-Tend interval by an overall odds ratio of 2.33 (95% CI 1.57-3.45). Heart rate correction, electrocardiographic (ECG) measurement methods and the selection of ECG leads were major sources of heterogeneity. Subgroup analyses revealed that heart rate correction did not affect the association of the Tpeak-Tend interval with mortality outcomes, whereas this finding was not evident in all measurement methods. The Tpeak-Tend interval was found to be significantly associated with all-cause mortality. Further studies are warranted to confirm the prognostic value of the Tpeak-Tend interval.

6.
J Clin Monit Comput ; 36(4): 1205-1212, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34542735

RESUMEN

With electrical impedance tomography (EIT) recruitment and de-recruitment phenomena can be quantified and monitored at bedside. The aim was to examine the feasibility of EIT with respect to monitor atelectasis formation and resolution in the post anesthesia care unit (PACU). In this observational study, 107 postoperative patients were investigated regarding the presence and recovery of atelectasis described by the EIT-derived parameters Global Inhomogeneity Index (GI Index), tidal impedance variation (TIV), and the changes in end-expiratory lung impedance (ΔEELI). We examined whether the presence of obesity (ADP group) has an influence on pulmonary recovery compared to normal weight patients (NWP group). During the stay at PACU, measurements were taken every 15 min. GI Index, TIV, and ΔEELI were calculated for each time point. 107 patients were monitored and EIT-data of 16 patients were excluded for various reasons. EIT-data of 91 patients were analyzed off-line. Their length of stay averaged 80 min (25th and 75th quartile 52-112). The ADP group demonstrated a significantly higher GI Index at PACU arrival (p < 0.001). This finding disappeared during their stay at the PACU. Additionally, the ADP group showed a significant increase in ΔEELI between PACU arrival and discharge (p = 0.025). Furthermore, TIV showed a significantly lower value during the first 90 min of PACU stay as compared to the time period thereafter (p = 0.036). Our findings demonstrate that obesity has an influence on intraoperative atelectasis formation and de-recruitment during PACU stay. The application of EIT in spontaneously breathing PACU patients seems meaningful in monitoring pulmonary recovery.


Asunto(s)
Anestesia , Neumonía , Atelectasia Pulmonar , Humanos , Impedancia Eléctrica , Pulmón , Obesidad , Tomografía/métodos
7.
J Clin Med ; 9(12)2020 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-33255530

RESUMEN

Guidelines for the treatment of severe bleeding comprise viscoelastic-test-guided use of coagulation factor concentrates as part of their recommendations. The aim of this study is to investigate the effects of substituting fibrinogen, prothrombin complex concentrate, and a combination of both on conventional coagulation tests, viscoelastic test results, and thrombin generation. Blood was drawn from seven healthy volunteers to obtain platelet-free plasma, which later was diluted by replacing 40%, 60%, 80%, 90%, 95%, and 99% with a crystalloid solution. The diluted samples were spiked with fibrinogen concentrate, prothrombin complex concentrate, a combination of both, or a corresponding amount of crystalloid solution. Up to a dilution level of 95%, viscoelastically determined clotting time was significantly shorter in the group substituted with fibrinogen only in comparison with the additional use of prothrombin complex concentrate. Clot firmness and endogenous thrombin potential remained at relatively stable values up to a dilution level of 95% with the substitution of fibrinogen but not prothrombin complex concentrate. Substitution of prothrombin complex concentrate led to an excessive overshoot of thrombin generation. The results of our study question currently propagated treatment algorithms for bleeding patients that include the use of prothrombin complex concentrate for patients without former intake of oral anticoagulants. Even in severely bleeding patients, thrombin generation might be sufficient to achieve adequate hemostasis.

8.
PLoS One ; 14(11): e0225218, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31721803

RESUMEN

BACKGROUND: Animal trials contribute to major achievements in medical science. The so-called lavage model is frequently used to evaluate ventilation strategies in acute respiratory distress syndrome (ARDS) using electrical impedance tomography (EIT). But, the lavage model itself might have systematic impacts on EIT parameters. Therefore, we established an additional experimental model, in which ARDS is caused by intravenously administered lipopolysaccharide (LPS). In this study, we want to examine if EIT measurements provide consistent results in both experimental models or whether the pathophysiology of the model influences the findings. Overall, we want to compare both experimental models regarding clinical parameters and EIT-derived indices, namely the global inhomogeneity (GI) index and the regional ventilation delay (RVD) index. METHODS: Nineteen pigs were included in this study, allocated to the control group (CO; n = 5), lavage group (LAV; n = 7) and LPS group (LPS; n = 7). After baseline measurements and the establishment of ARDS, assessment of respiratory mechanics, hemodynamics, gas exchange and EIT recordings were performed hourly over eight hours. RESULTS: In both experimental ARDS models, EIT measurements provided reliable results. But, the GI and the RVD index did not show consistent results as compared to the CO group. Initially, GI and RVD index were higher in the LAV group but not in the LPS group as compared to the CO group. This effect disappeared during the study. Furthermore, the GI index and the RVD index were higher in the LAV group compared to the LPS group in the beginning as well. This, once again, disappeared. Clinical lung injury parameters remained more stable when using LPS. CONCLUSION: The two models showed quite different influences on the GI and RVD index. This implies, that the underlying pathophysiology affects EIT parameters and thus the findings. Hence, translation to EIT-guided clinical therapy in humans suffering from ARDS might be limited.


Asunto(s)
Impedancia Eléctrica , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/etiología , Tomografía Computarizada por Rayos X , Animales , Biomarcadores , Femenino , Hemodinámica , Humanos , Síndrome de Dificultad Respiratoria/fisiopatología , Porcinos
9.
PLoS One ; 14(11): e0224747, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31693688

RESUMEN

Pig experiments have played an important role in medical breakthroughs during the last century. In fact, pigs are one of the major animal species used in translational research, surgical models and procedural training due to their anatomical and physiological similarities to humans. To ensure high bioethical standards in animal trials, new directives have been implemented, among others, to refine the procedures and minimize animals' stress and pain. This paper presents a contactless motion-based approach for monitoring cardiorespiratory signals (heart rate and respiratory rate) in anesthetized pigs using infrared thermography. Heart rate monitoring is estimated by measuring the vibrations (precordial motion) of the chest caused by the heartbeat. Respiratory rate, in turn, is computed by measuring the mechanical chest movements that accompany the respiratory cycle. To test the feasibility of this approach, thermal videos of 17 anesthetized pigs were acquired and analyzed. A high agreement between infrared thermography and a gold standard (electrocardiography and capnography-derived respiratory rate) was achieved. The mean absolute error averaged 3.43 ± 3.05 bpm and 0.27 ± 0.48 breaths/min for heart rate and respiratory rate, respectively. In sum, infrared thermography is capable of assessing cardiorespiratory signals in pigs. Future work should be conducted to evaluate infared thermography capability of capturing information for long term monitoring of research animals in a diverse set of facilities.


Asunto(s)
Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico/métodos , Frecuencia Respiratoria/fisiología , Termografía/métodos , Experimentación Animal/ética , Bienestar del Animal/ética , Animales , Estudios de Factibilidad , Rayos Infrarrojos , Modelos Animales , Monitoreo Fisiológico/ética , Monitoreo Fisiológico/instrumentación , Procesamiento de Señales Asistido por Computador , Porcinos/fisiología , Termografía/ética , Termografía/instrumentación
10.
J Med Internet Res ; 21(1): e11939, 2019 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-30609988

RESUMEN

BACKGROUND: To treat many patients despite lacking personnel resources, triage is important in disaster medicine. Various triage algorithms help but often are used incorrectly or not at all. One potential problem-solving approach is to support triage with Smart Glasses. OBJECTIVE: In this study, augmented reality was used to display a triage algorithm and telemedicine assistance was enabled to compare the duration and quality of triage with a conventional one. METHODS: A specific Android app was designed for use with Smart Glasses, which added information in terms of augmented reality with two different methods-through the display of a triage algorithm in data glasses and a telemedical connection to a senior emergency physician realized by the integrated camera. A scenario was created (ie, randomized simulation study) in which 31 paramedics carried out a triage of 12 patients in 3 groups as follows: without technical support (control group), with a triage algorithm display, and with telemedical contact. RESULTS: A total of 362 assessments were performed. The accuracy in the control group was only 58%, but the assessments were quicker (on average 16.6 seconds). In contrast, an accuracy of 92% (P=.04) was achieved when using technical support by displaying the triage algorithm. This triaging took an average of 37.0 seconds. The triage group wearing data glasses and being telemedically connected achieved 90% accuracy (P=.01) in 35.0 seconds. CONCLUSIONS: Triage with data glasses required markedly more time. While only a tally was recorded in the control group, Smart Glasses led to digital capture of the triage results, which have many tactical advantages. We expect a high potential in the application of Smart Glasses in disaster scenarios when using telemedicine and augmented reality features to improve the quality of triage.


Asunto(s)
Medicina de Desastres/métodos , Servicios Médicos de Urgencia/métodos , Anteojos/normas , Incidentes con Víctimas en Masa/psicología , Telemedicina/métodos , Triaje/métodos , Humanos , Incidentes con Víctimas en Masa/mortalidad
11.
Biomed Tech (Berl) ; 64(3): 365-371, 2019 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-29949505

RESUMEN

The gold standard for estimating blood alcohol content (BAC) after alcohol consumption is a blood sample analysis. An innovative technology to estimate BAC is based on impedance cardiography and bioimpedance spectroscopy (BIS). This study investigated whether it is possible to estimate increasing blood alcohol levels during a drinking trial with bioimpedance measurement techniques. Twenty-one healthy volunteers were assigned to a test (ethanol) group (ETH) or a reference group (H2O). After baseline measurements, the ETH group ingested 120 ml of vodka, followed by a resorption phase of 50 min. Then, bioimpedance and breath alcohol measurements were performed. Thereafter, 60 ml of vodka was ingested and another resorption phase of 50 min was followed by bioimpedance and breath alcohol measurements. This procedure was repeated until alcohol levels exceeded 0.4 mg/l. The H2O group performed in the same way with water. For all measurements, extracellular resistance (Re) and the base impedance (Z0) were computed. Regarding BIS, several parameters differed significantly between the ETH and the H2O group. Re increased in ETH (p=0.005), but not in the H2O group when comparing the first and last measurements. Z0 also increased significantly in the ETH group (p=0.001). To conclude, with BIS measurements, it is possible to measure increasing blood alcohol levels.


Asunto(s)
Intoxicación Alcohólica/sangre , Cardiografía de Impedancia/métodos , Cardiografía de Impedancia/normas , Impedancia Eléctrica , Humanos , Proyectos Piloto , Análisis Espectral
12.
Sensors (Basel) ; 18(5)2018 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-29783683

RESUMEN

The post-anesthesia care unit (PACU) is the central hub for recovery after surgery, especially when the surgery is performed under general anesthesia. Aside from clinical aspects, respiratory impairment is one of the major causes of morbidity and affected recovery in the PACU and should therefore be monitored. In previous studies, infrared thermography was applied to assess the breathing rate (BR) of healthy volunteers. Here, the transferability of published methods for postoperative patients in the PACU was examined. Video recordings of 28 patients were acquired using a long-wave infrared camera, and analyzed offline. For validation purposes, BRs derived from body surface electrocardiography were measured simultaneously. In general, a close agreement between the two techniques (r = 0.607, p = 0.002 upon arrival, and r = 0.849, p < 0.001 upon discharge from the PACU) was obtained. In conclusion, the algorithm was demonstrated to be feasible and reliable under these challenging conditions.


Asunto(s)
Periodo de Recuperación de la Anestesia , Monitoreo Fisiológico/métodos , Frecuencia Respiratoria/fisiología , Termografía/métodos , Anciano , Femenino , Alemania , Humanos , Rayos Infrarrojos , Masculino , Persona de Mediana Edad , Enfermería Posanestésica/métodos , Respiración
13.
Respir Physiol Neurobiol ; 254: 1-9, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29614341

RESUMEN

In critically ill patients, correct diagnosis of lung disease is essential for successful therapy. Therefore, this study investigated whether new multi-frequency electrical impedance tomography (mfEIT) can detect, monitor and differentiate between pathologies associated with the acute respiratory distress syndrome (ARDS). For this pilot study, 12 pigs were randomized into an ARDS (bronchoalveolar lavage) group (n = 7) and a healthy control group (n = 5). Animals were monitored by means of mfEIT. In addition to functional images, a new impaired-ventilation (rImpVent) index was developed and frequency-difference images were computed and analyzed. Amplitude functional images revealed only small differences between the groups. However, phase functional images were of greater importance in distinguishing between lung pathologies. Correlation images showed substantial differences between the two groups. The new rImpVent index achieved high sensitivity (91%) and specificity (92%) in detecting PaO2/FiO2 ≤ 200 mmHg. mfEIT was able to detect lung edema, differentiate this from atelectasis, and also monitor their progress over time in terms of global and regional differences.


Asunto(s)
Lesión Pulmonar/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Atelectasia Pulmonar/diagnóstico por imagen , Tomografía , Animales , Edema/diagnóstico por imagen , Impedancia Eléctrica , Femenino , Proyectos Piloto , Curva ROC , Distribución Aleatoria , Sus scrofa , Tomografía/métodos
14.
Physiol Meas ; 39(3): 035009, 2018 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-29406309

RESUMEN

OBJECTIVE: Bioimpedance measurements such as bioimpedance spectroscopy (BIS) or electrical impedance tomography (EIT) are used in many biomedical applications. While BIS measures and analyzes the impedance in a frequency range at constant electrode positions, EIT aims to reconstruct images of the conductivity distribution from multiple measurements at different electrode positions. Our aim is to add spatial information to tetrapolar BIS measurements by using electrode positions that focus measurements on desired regions of interest. In this paper, we aim to investigate, whether internal electrodes that can be integrated into breathing or gastroesophageal tubes, can improve the local sensitivity of bioimpedance spectroscopy measurements. APPROACH: We present the results of a simulation study, in which we investigated more than 4 M different electrode configurations on their ability to monitor specific regions of interest (ROI) in the lung. Based on the sensitivity, which describes the impact of a conductivity change on the measured impedance, we define three main criteria which we use to evaluate our simulation results: the selectivity [Formula: see text], which describes the impact of a conductivity change inside the region of interest compared to a conductivity change outside the ROI; the homogeneity [Formula: see text], which describes the distribution of the sensitivity inside the ROI; and the absolute impedance contribution ratio [Formula: see text], which describes the contribution of the ROI to the measured impedance. MAIN RESULTS: Depending on the region of interest, electrode configurations using internal electrodes are between 9.8 % and 90 % better with respect to these criteria than configurations using external electrodes only. SIGNIFICANCE: The combination of internal and external electrodes improves the focusing ability of tetrapolar impedance measurements on specific lung regions, which may be especially beneficial for lung monitoring in intensive care.


Asunto(s)
Pulmón/diagnóstico por imagen , Tomografía/instrumentación , Impedancia Eléctrica , Electrodos
15.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 352-355, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29059883

RESUMEN

Adequate medical treatment of the Acute Respiratory Distress Syndrome is still challenging since patient-individual aspects have to be taken into account. Lung protective ventilation and hemodynamic stability have always been two of the most crucial aims of intensive care therapy. For both aspects, a continuous - preferably non-invasive - monitoring is desirable that is available at the bedside. Unfortunately, there is no technique clinically established yet, that provides both measurement of cardiac stroke volume and ventilation dynamics in real-time. Electrical Impedance Tomography (EIT) is a promising technique to close this gap. The aim of the study was to investigate if stroke volume can be estimated by a self-developed software using EIT-based image analysis. In addition, two EIT-derived parameters, namely Global Inhomogeneity Index (GII) and Impedance Ratio (IR), were calculated to evaluate homogeneity of air distribution. Experimental acute lung injury (ALI) was provoked in seven female pigs (German Landrace) by lipopolysaccharide (LPS). All animals suffered from experimental ALI 3 to 4 hours after LPS infusion. At defined time points, respiratory and hemodynamic parameters, blood gas analyses and EIT-recordings were performed. Eight hours after ALI, animals were euthanized. Stroke volume, derived from pulmonary artery catheter (PAC), decreased continuously up to four hours after ALI. Then, stroke volume increased slightly. Stroke volume, derived from the self-developed tool, showed the same characteristics (p=0.047, r = 0.365). In addition to the GII and IR individually, both classified scores showed a high correlation with the Horowitz Index, defined as paO2/FiO2. To conclude, EIT-derived measures enabled a reliable estimation of cardiac stroke volume and regional distribution of ventilation.


Asunto(s)
Respiración Artificial , Lesión Pulmonar Aguda , Animales , Impedancia Eléctrica , Femenino , Porcinos , Tomografía
16.
Respir Care ; 62(3): 340-349, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27999152

RESUMEN

BACKGROUND: Mechanical ventilation is necessary in diverse clinical circumstances. Especially in the context of ARDS, so-called protective ventilation strategies must be followed. It is already known that PEEP might enhance oxygenation in ARDS. However, determining the optimal PEEP settings in clinical routines is challenging. Electrical impedance tomography (EIT) is a promising technique with which to adjust ventilator settings. We investigated whether the combination of different EIT parameters, namely the global inhomogeneity and hyperdistension indices, may lead to a feasible and safe PEEP setting. METHODS: ARDS was induced by a double-hit approach in 18 pigs weighing, on average, 34.8 ± 3.97 kg. First, a surfactant washout was conducted; second, the tidal volume was increased to 20 mL/kg body weight, triggering a ventilator-induced lung injury. Subsequently, pigs were randomized to either the EIT or control groups, followed by an observation time of 24 h. In the control group, PEEP was set according to the ARDS network table. In the EIT group, a PEEP trial was conducted to determine an appropriate PEEP. At defined time points, hemodynamic measures, ventilation parameters, and EIT recordings, as well as blood samples, were taken. After euthanization, lungs were removed for subsequent histopathological and cytological examination. RESULTS: The combination of PEEP and FIO2 differed between groups, although respiratory compliance, gas exchange, and histopathological examinations, as well as hemodynamics, did not show any statistical differences between the EIT and control groups. However, in the control group, the PEEP/FIO2 settings followed the given coupling; in the EIT group, divergent individual combinations of PEEP and FIO2 ranges occurred. CONCLUSIONS: PEEP setting by EIT facilitates a more individual ventilation therapy. However, in our relatively short ARDS observation period of 24 h, no significant differences appeared in common clinical parameters compared with a control group.


Asunto(s)
Impedancia Eléctrica/uso terapéutico , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Tomografía/métodos , Animales , Modelos Animales de Enfermedad , Surfactantes Pulmonares , Síndrome de Dificultad Respiratoria/etiología , Porcinos , Resultado del Tratamiento , Lesión Pulmonar Inducida por Ventilación Mecánica/complicaciones
17.
Physiol Meas ; 37(12): 2111-2129, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27811407

RESUMEN

Impedance spectroscopy can be used to analyze the dielectric properties of various materials. In the biomedical domain, it is used as bioimpedance spectroscopy (BIS) to analyze the composition of body tissue. Being a non-invasive, real-time capable technique, it is a promising modality, especially in the field of lung monitoring. Unfortunately, up to now, BIS does not provide any regional lung information as the electrodes are usually placed in hand-to-hand or transthoracic configurations. Even though transthoracic electrode configurations are in general capable of monitoring the lung, no focusing to specific regions is achieved. In order to resolve this issue, we use a finite element model (FEM) of the human body to study the effect of different electrode configurations on measured BIS data. We present evaluation results and show suitable electrode configurations for eight lung regions. We show that, using these optimized configurations, BIS measurements can be focused to desired regions allowing local lung analysis.


Asunto(s)
Espectroscopía Dieléctrica/instrumentación , Análisis de Elementos Finitos , Pulmón , Espectroscopía Dieléctrica/normas , Impedancia Eléctrica , Electrodos , Humanos , Estándares de Referencia
18.
Anesth Analg ; 112(5): 1139-46, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21474656

RESUMEN

BACKGROUND: Strategies to attenuate ventilator-associated lung injury have been tested in various experimental methods of acute lung injury (ALI). Conclusions are often drawn from physiologic and biologic effects, but the influence of the model on these results is not known. Our aim in this study was to characterize frequently used models of experimental ALI. METHODS: Twenty Sprague Dawley rats were anesthetized and their lungs mechanically ventilated for 5 hours. Three models of ALI (surfactant washout, acid aspiration, and high tidal volume ventilation) were investigated with regard to hemodynamics, respiratory mechanics, gas exchange, lung pathology, and inflammatory reactions. Animals without ALI served as controls. RESULTS: Five animals in each group were analyzed. Dynamic compliance and Pao(2)/fraction of inspired oxygen ratio decreased by at least 50% in all groups after 1 hour. Whereas compliance remained decreased in all models, oxygenation returned to baseline values in the lavage group after 5 hours. Diffuse alveolar damage was worse in the high tidal volume model and was not different between the control and lavage animals. Interleukin-6 was increased in bronchoalveolar lavage fluid in the aspiration and high tidal volume models. CONCLUSIONS: Although comparable physiologic effects meeting acute respiratory distress syndrome criteria were achieved in all models, the biologic responses varied among lung injury models. The acid aspiration model created both respiratory and inflammatory responses typically seen in ALI; these data suggest that it may be the most clinically applicable model to study the intermediate-term effects of ventilator-associated lung injury in rats.


Asunto(s)
Pulmón/fisiopatología , Lesión Pulmonar Inducida por Ventilación Mecánica/fisiopatología , Animales , Líquido del Lavado Bronquioalveolar/inmunología , Modelos Animales de Enfermedad , Hemodinámica , Hemorragia/etiología , Hemorragia/fisiopatología , Mediadores de Inflamación/metabolismo , Molécula 1 de Adhesión Intercelular/metabolismo , Interleucina-10/metabolismo , Interleucina-6/metabolismo , Pulmón/inmunología , Pulmón/patología , Rendimiento Pulmonar , Masculino , Atelectasia Pulmonar/etiología , Atelectasia Pulmonar/fisiopatología , Edema Pulmonar/etiología , Edema Pulmonar/fisiopatología , Intercambio Gaseoso Pulmonar , Ratas , Ratas Sprague-Dawley , Mecánica Respiratoria , Factores de Tiempo , Factor de Necrosis Tumoral alfa/metabolismo , Regulación hacia Arriba , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología , Lesión Pulmonar Inducida por Ventilación Mecánica/inmunología , Lesión Pulmonar Inducida por Ventilación Mecánica/patología
19.
Intensive Care Med ; 36(8): 1427-35, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20237763

RESUMEN

PURPOSE: Ventilation problems are common in critically ill patients with intra-abdominal hypertension. The aim of this study was to investigate the effects of preserved spontaneous breathing during mechanical ventilation on hemodynamics, gas exchange, respiratory function and lung injury in experimental intra-abdominal hypertension. METHODS: Twenty anesthetized pigs were intubated and ventilated for 24 h with biphasic positive airway pressure without (BIPAP(PC)) or with additional, unsynchronized spontaneous breathing (BIPAP(SB)). In 12 animals, intra-abdominal pressure was increased to 30 mmHg for two 9 h periods followed by a 3 h pressure relief each. Eight animals served as controls and were ventilated for 24 h. Hemodynamics, gas exchange and respiratory mechanics were measured and lung injury was determined histologically. RESULTS: Intra-abdominal hypertension caused significant impairment of hemodynamics and respiratory mechanics in both modes. In the presence of intra-abdominal hypertension, BIPAP(SB) did not demonstrate superior respiratory mechanics and cardiovascular stability as compared to BIPAP(PC). Although the decrease of dynamic compliance and the increase of airway pressures were mitigated, BIPAP(SB) failed to lower pulmonary vascular resistance and caused increased dead space ventilation (p = 0.007). Blood pressures and cardiac output increased in BIPAP(SB), caused by an increase in heart rate (p < 0.001), but not in stroke volume (p = 0.06). BIPAP(SB) was associated with an increased breathing effort, decreased transpulmonary pressure during inspiration and lower lobe diffuse alveolar damage (p = 0.002). CONCLUSIONS: In the presence of severe intra-abdominal hypertension, the addition of unsupported spontaneous breaths to BIPAP did not improve hemodynamic and respiratory function and caused greater histopathologic damage to the lungs.


Asunto(s)
Abdomen/fisiología , Hipertensión , Respiración Artificial , Trabajo Respiratorio/fisiología , Animales , Presión de las Vías Aéreas Positiva Contínua/métodos , Hemodinámica , Masculino , Intercambio Gaseoso Pulmonar , Mecánica Respiratoria/fisiología , Porcinos , Lesión Pulmonar Inducida por Ventilación Mecánica
20.
Exp Lung Res ; 36(3): 159-66, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20337573

RESUMEN

Inhaled nitric oxide (iNO) improves gas exchange in about 60% of patients with acute respiratory distress syndrome (ARDS). Recruitment of atelectatic lung areas may improve responsiveness and preservation of spontaneous breathing (SB) may cause recruitment. Accordingly, preservation of SB may improve effectiveness of iNO. To test this hypothesis, iNO was evaluated in experimental acute lung injury (ALI) during SB. In 24 pigs with ALI, effects of 10 ppm iNO were evaluated during controlled mechanical ventilation (CMV) and SB in random order. Preservation of SB was provided by 4 different modes: Unassisted SB was enabled by biphasic positive airway pressure (BIPAP), moderate inspiratory assist was provided by pressure support (PS) and volume-assured pressure support (VAPS), maximum assist was ensured by assist control (A/C). Statistical analysis did not reveal gas exchange improvements due to SB alone. Significant gas exchange improvements due to iNO were only achieved during unassisted SB with BIPAP (P <.05) but not during CMV or assisted SB. The authors conclude that effectiveness of iNO may be improved by unassisted SB during BIPAP but not by assisted SB. Thus combined iNO and unassisted SB is possibly most effective to improve gas exchange in severe hypoxemic ARDS.


Asunto(s)
Lesión Pulmonar Aguda/terapia , Óxido Nítrico/administración & dosificación , Respiración Artificial , Respiración/efectos de los fármacos , Lesión Pulmonar Aguda/tratamiento farmacológico , Lesión Pulmonar Aguda/fisiopatología , Administración por Inhalación , Animales , Modelos Animales de Enfermedad , Femenino , Hemodinámica/efectos de los fármacos , Hipoxia/fisiopatología , Hipoxia/terapia , Respiración con Presión Positiva , Intercambio Gaseoso Pulmonar/efectos de los fármacos , Respiración Artificial/métodos , Mecánica Respiratoria/efectos de los fármacos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...