1.
Artículo en Inglés | MEDLINE | ID: mdl-38958930

RESUMEN

PURPOSE: To investigate whether standard keratometry (K) or total corneal power (TCP) lead to more accurate refractive outcomes for intraocular lens (IOL) power calculation. SETTING: Public hospital. DESIGN: Retrospective evaluation of a diagnostic test instrument. METHODS: Preoperatively all patients underwent optical biometry with the Anterion (Heidelberg), a swept-source optical coherence tomographer providing both K and TCP. The same IOL model was implanted in all cases. The whole sample was divided into a training dataset, used to optimize the formula constants, and a testing dataset, used to investigate the spherical equivalent prediction error (SEQ-PE) of 8 IOL power formulas. Trueness, precision and accuracy were evaluated by means of the robust two-sample t-test. Cochran's Q test was performed to assess whether the percentage of eyes with an SEQ-PE within each threshold was significantly different; in such an event, the McNemar test was then applied. RESULTS: Both the training and testing datasets included 317 eyes. No significant differences were detected for trueness, due to constant optimization. Precision and accuracy were better when K was entered, although a statistically significant difference was observed only with the EVO (precision: p = 0.02 and accuracy: p = 0.03) and Haigis formula (p <0.01 for both precision and accuracy). No significant differences were observed for the percentage of eyes with an absolute SEQ-PE within any threshold. CONCLUSIONS: With most formulas, IOL power calculation is not more accurate when TCP is used instead of K.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38958959

RESUMEN

PURPOSE: To compare two different datasets, using Eyetemis, an online analytical tool designed for assessing the spherical equivalent prediction errors (SEQ-PE) of intraocular lens (IOL) power calculation formulas following cataract surgery. SETTING: Institutional. DESIGN: Retrospective case series. METHODS: The study was comprised of two distinct datasets of patients who had undergone successful cataract surgery. Dataset-1 includes standard eyes whereas Dataset-2 includes eyes with keratoconus. An online tool was used for SEQ-PE analysis across the 2 datasets, adhering to ISO standards for evaluating accuracy based upon trueness and precision. The tool incorporates robust t-tests for comparing the trimmed-mean of the data, adjusting for heteroscedasticity. IOL constants in Dataset-1 were optimized for the comparison of Hoffer Q, Holladay1, SRK/T, Haigis and Barrett Universal II (BUII) formulas. In Dataset-2, IOL constants from the IOLCon website, were used for the comparison of the BUII and its designated KCN-version: Barrett TrueK Keratoconus (TrueK [KCN]). RESULTS: For Dataset-1: the trimmed-mean SEQ-PE values of all formulas were not significantly different from zero. BUII had superior precision and accuracy compared to all other formulas except from Haigis (P≤ 0.04). For Dataset-2: BUII's trimmed-mean SEQ-PE was significantly different from zero (0.59D, P< 0.01), unlike the TrueK [KCN] (0.12D, P= 0.10). Additionally, TrueK [KCN] exhibited enhanced precision and accuracy relative to BUII (P< 0.01). CONCLUSIONS: The online analysis tool provides a streamlined approach for assessing the prediction accuracy of SEQ refraction following cataract surgery, effectively evaluating trueness, precision, and overall accuracy through the use of advanced statistical methods.

3.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593262

RESUMEN

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Asunto(s)
Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/diagnóstico , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Facoemulsificación/métodos , Óptica y Fotónica , Refracción Ocular , Biometría/métodos
4.
Eur J Ophthalmol ; : 11206721241245747, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38632941

RESUMEN

PURPOSE: To present a reproducible method to calculate the toricity needed at the intraocular lens (IOL) plane with toric phakic IOLs (ICL, Staar Surgical) and compare its results with those obtained with the online calculator provided by the manufacturer. DESIGN: Retrospective case series. SETTING: Private practice, Buenos Aires, Argentina. METHODS: The formula originally described by Holladay to calculate the IOL power in phakic eyes was used to calculate the required spherical power along the less refractive meridian and along the more refractive meridian. Meridional analysis was applied to calculate the required toricity at the IOL plane and the surgically induced corneal astigmatism was incorporated into the calculations. The refractive cylinder predicted by this method and by the online calculator of the manufacturer were compared to the postoperative refractive cylinder by means of vector analysis. The possible changes in the ratio of toricity in patients with different amounts of astigmatism and anterior chamber depth are assessed in a theoretical section. RESULTS: In 35 eyes, the measured mean postoperative refractive cylinder was 0.09 D @ 99°, the mean predicted postoperative refractive astigmatism was 0.04 D @ 102° according to the manufacturer's online calculator and 0.09 D @100° according to our method. With both methods, 91.43% of eyes had an absolute cylinder prediction error within ±0.50 diopters. CONCLUSIONS: The method described in this article to calculate the toricity of phakic IOLs has a refractive accuracy similar to that of the original calculator developed by the manufacturer.

6.
Am J Ophthalmol ; 260: 102-114, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38092314

RESUMEN

PURPOSE: This study aimed to explore the concept of total keratometry (TK) by analyzing extensive international datasets representing diverse ethnic backgrounds. The primary objective was to quantify the disparities between traditional keratometry (K) and TK values in normal eyes and assess their impact on intraocular lens (IOL) power calculations using various formulas. DESIGN: Retrospective multicenter intra-instrument reliability analysis. METHODS: The study involved the analysis of biometry data collected from ten international centers across Europe, the United States, and Asia. Corneal power was expressed as equivalent power and astigmatic vector components for both K and TK values. The study assessed the influence of these differences on IOL power calculations using different formulas. The results were analyzed and plotted using Bland-Altman and double angle plots. RESULTS: The study encompassed a total of 116,982 measurements from 57,862 right eyes and 59,120 left eyes. The analysis revealed a high level of agreement between K and TK values, with 93.98% of eyes exhibiting an absolute difference of 0.25 D or less. Astigmatism vector differences exceeding 0.25 D and 0.50 D were observed in 39.43% and 1.08% of eyes, respectively. CONCLUSIONS: This large-scale study underscores the similarity between mean K and TK values in healthy eyes, with rare clinical implications for IOL power calculation. Noteworthy differences were observed in astigmatism values between K and TK. Future investigations should delve into the practicality of TK values for astigmatism correction and their implications for surgical outcomes.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Tomografía de Coherencia Óptica/métodos , Astigmatismo/diagnóstico , Reproducibilidad de los Resultados , Córnea , Biometría/métodos , Estudios Retrospectivos , Refracción Ocular
9.
J Refract Surg ; 39(4): 249-256, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37040214

RESUMEN

PURPOSE: To scrutinize the accuracy of 24 intraocular lens (IOL) power calculation formulas in unoperated eyes. METHODS: In a series of consecutive patients undergoing phacoemulsification and implantation of the Tecnis 1 ZCB00 IOL (Johnson & Johnson Vision), the following formulas were evaluated: Barrett Universal II, Castrop, EVO 2.0, Haigis, Hoffer Q, Hoffer QST, Holladay 1, Holladay 2, Holladay 2 (AL Adjusted), K6 (Cooke), Kane, Karmona, LSF AI, Naeser 2, OKULIX, Olsen (OLCR), Olsen (standalone), Panacea, PEARL-DGS, RBF 3.0, SRK/T, T2, VRF, and VRF-G. The IOLMaster 700 (Carl Zeiss Meditec AG) was used for biometric measurements. With optimized lens constants, the mean prediction error (PE) and its standard deviation (SD), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with prediction erros within ±0.25, ±0.50, ±0.75, ±1.00, and ±2.00 D were analyzed. RESULTS: Three hundred eyes of 300 patients were enrolled. The heteroscedastic method revealed statistically significant differences (P < .05) among formulas. Newly developed methods such as the VRF-G (standard deviation [SD] ±0.387 D), Kane (SD ±0.395 D), Hoffer QST (SD ±0.404 D), and Barrett Universal II (SD ±0.405) were more accurate than older formulas (P < .05). These formulas also yielded the highest percentage of eyes with a PE within ±0.50 D (84.33%, 82.33%, 83.33%, and 81.33%, respectively). CONCLUSIONS: Newer formulas (Barrett Universal II, Hoffer QST, K6, Kane, Karmona, RBF 3.0, PEARL-DGS, and VRF-G) were the most accurate predictors of postoperative refractions. [J Refract Surg. 2023;39(4):249-256.].


Asunto(s)
Lentes Intraoculares , Refracción Ocular , Humanos , Agudeza Visual , Óptica y Fotónica , Estudios Retrospectivos
11.
J Refract Surg ; 39(3): 158-164, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36892239

RESUMEN

PURPOSE: To evaluate the accuracy of nine formulas to calculate the power of a new extended depth-of-focus intraocular lens (EDOF IOL), the AcrySof IQ Vivity (Alcon Laboratories, Inc), using measurements from two optical biometers, the IOLMaster 700 (Carl Zeiss Meditec AG) and Anterion (Heidelberg Engineering GmbH). METHODS: After constant optimization, the accuracy of these formulas was analyzed in 101 eyes: Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane, Olsen, RBF 3.0, and SRK/T. Both standard and total keratometry from the IOLMaster 700 and standard keratometry from the Anterion were used for each formula. RESULTS: Constant optimization provided slightly different values for the A-constant, which ranged between 118.99 and 119.16, depending on the formula and the optical biometer. According to the heteroscedastic test, within each keratometry modality the standard deviation of the SRK/T was significantly higher compared to that of the Holladay 1, Kane, Olsen, and RBF 3.0 formulas. The SRK/T formula provided less accurate results also when the absolute prediction errors were compared by Friedman test. According to McNemar's test with Holm corrections, statistically significant differences were found within each keratometry modality between the percentage of eyes with a prediction error within ±0.25 diopters obtained with the Olsen formula compared to the Holladay 1 and Hoffer Q formulas. CONCLUSIONS: Constant optimization remains a mandatory step to achieve the best outcomes with the new EDOF IOL: the same constant should not be used for all formulas and for both optical biometers. Different statistical tests revealed that older IOL formulas have lower accuracy compared to newer formulas. [J Refract Surg. 2023;39(3):158-164.].


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Tomografía de Coherencia Óptica , Óptica y Fotónica , Biometría/métodos , Córnea , Estudios Retrospectivos , Refracción Ocular , Longitud Axial del Ojo
12.
J Cataract Refract Surg ; 49(4): 378-384, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36729423

RESUMEN

PURPOSE: To investigate the new Hoffer QST (Savini/Taroni) formula (HQST) and compare it with the original Hoffer Q (HQ) and 4 latest generation formulas. SETTING: I.R.C.C.S.-G.B. Bietti Foundation, Rome, Italy. DESIGN: Retrospective case series. METHODS: Refractive outcomes of the HQST, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, HQ, Kane, and Radial Basis Function (RBF) 3.0 formulas were compared. Subgroup analysis was performed in short (<22 mm) and long (>25 mm) axial length eyes. The SD of the prediction error (PE) was investigated using the heteroscedastic method. RESULTS: 1259 eyes of 1259 patients divided in a White group (n=696), implanted with the AcriSof SN60AT (Alcon Labs), and an Asian group (n=563), implanted with the SN60WF (Alcon Labs), were investigated. In the Asian group, the heteroscedastic method did not disclose any significant difference among the SD of the 4 modern formulas (range from 0.333 to 0.346 D), whereas the SD of the HQ formula (0.384 D) was significantly higher. Compared with the original HQ formula, in both White and Asian groups, the HQST formula avoided the mean myopic PE in short eyes and the mean hyperopic PE in long eyes. CONCLUSIONS: The new HQST formula was superior to the original HQ formula and reached statistical and clinical results comparable with those achieved by the BUII, EVO, Kane, and RBF formulas.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Longitud Axial del Ojo , Biometría/métodos , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos , Agudeza Visual
13.
Am J Ophthalmol ; 246: 236-241, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36252676

RESUMEN

PURPOSE: Optical devices are the gold standard for ocular biometry; however, they are unable to obtain high-quality optical coherence tomography (OCT) images. The current study aimed to evaluate ocular measurements and intraocular lens (IOL) calculation used in an anterior/posterior segment OCT device and to compare the results with those of a validated biometer. DESIGN: Prospective evaluation of a diagnostic tool. METHODS: This study enrolled healthy subjects at the Hygeia Clinic, Gdansk, Poland, between October 2021 and November 2021. All individuals had ocular biometry measured with a validated biometer (Pentacam AXL) and with a new module of an anterior/posterior segment OCT device (Revo 80, Optopol Technologies). All IOL calculations were performed for the right eye with keratometric values from the Pentacam for one IOL: the Alcon AcrySof IQ SN60WF, with plano target setting. RESULTS: The mean age of the 144 participants was 25.23 ± 7.15 years. The axial length measured with Revo was longer than with Pentacam AXL (24.08 ± 1.13 vs 23.98 ± 1.13; P < .0001), a 0.10 ± 0.04 mm difference. This translated into a significantly lower IOL power to achieve emmetropia for all formulas (-0.34 ± 0.15, -0.32 ± 0.13, -0.34 ± 0.19, and -0.30 ± 0.15 for the Hoffer Q, Holladay I, Haigis, and SRK/T formulas, respectively). The study showed high agreement between the devices: nearly 90% of eyes were within ±0.50 diopters for all of the analyzed formulas (r > 0.99). CONCLUSIONS: The present study demonstrates that the results of IOL calculation with the OCT biometer have a very strong correlation with those obtained with the Pentacam AXL; however, axial length measurements and calculated IOL power cannot be considered interchangeable.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Adolescente , Adulto Joven , Adulto , Tomografía de Coherencia Óptica/métodos , Longitud Axial del Ojo , Ojo Artificial , Biometría/métodos , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos
14.
J Cataract Refract Surg ; 49(1): 5-10, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36026703

RESUMEN

PURPOSE: To evaluate the repeatability of the measurements provided by a new optical biometer (EyeStar 900) based on swept-source optical coherence tomography (SS-OCT) and their agreement with the measurements given by 2 validated biometers based on the same technology, the IOLMaster 700 and Argos. SETTING: IRCCS G.B. Bietti Foundation, Rome, Italy. DESIGN: Prospective evaluation of diagnostic test. METHODS: In a series of unoperated eyes, 3 consecutive scans were acquired with the EyeStar 900, and 1 with the IOLMaster 700 and the Argos. The following biometry parameters were analyzed: axial length (AL), keratometry (K), corneal astigmatism, central corneal thickness, corneal diameter (CD), anterior chamber depth (ACD), lens thickness (LT), and lens tilting. Repeatability was assessed using test-retest variability, the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC); agreement was based on the 95% limits of agreement. RESULTS: 56 eyes of 56 patients were analyzed. High repeatability was achieved for all measured parameters, as the CoV was <1% in most cases and ICC was >0.95 for all parameters. Good to high agreement was found among the measurements of the 3 optical biometers, although some statistically significant differences were detected between the EyeStar 900 and Argos (mean K, ACD, LT, and CD were higher with the Argos). The Argos measured a shorter AL in eyes >25 mm. CONCLUSIONS: The new generation SS-OCT EyeStar 900 optical biometer produces highly repeatable measurements that are in good agreement with those provided by 2 previously validated instruments.


Asunto(s)
Longitud Axial del Ojo , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Longitud Axial del Ojo/anatomía & histología , Reproducibilidad de los Resultados , Interferometría , Estudios Prospectivos , Córnea/anatomía & histología , Biometría/métodos , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/anatomía & histología
17.
J Refract Surg ; 38(7): 435-442, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35858193

RESUMEN

PURPOSE: To assess the accuracy of different corneal powers for intraocular (IOL) power calculation in combined Descemet membrane endothelial keratoplasty (DMEK) and cataract surgery and investigate whether preoperative parameters correlate to the prediction error (PE). METHODS: This prospective case series involved patients with Fuchs endothelial dystrophy receiving combined DMEK and cataract surgery. Preoperatively, patients underwent optical biometry and anterior segment OCT (AS-OCT). AS-OCT measurements were repeated 6 months postoperatively, when final refraction was assessed. The PE was calculated using the preoperative average keratometry (Kave) measured by the optical biometer and User Group for Laser Interference Biometry (ULIB) constants. It was also calculated, after constant optimization, using the preoperative Kave from both devices and the total corneal power (TCP) measured by AS-OCT, as well as the postoperative Kave and TCP measured by AS-OCT. RESULTS: ULIB constants resulted in the highest hyperopic PE (P < .0001). Constant optimization improved the results, because the PE was zeroed out and the absolute PEs decreased. No significant difference was found among the Barrett Universal II, Emmetropia Verifying Optical 2.0, Haigis, Hoffer Q, Holladay 1, Kane, and SRK/T formulas. Further improvement was achieved with the postoperative Kave and TCP, although the accuracy remained moderate. The PE based on preoperative corneal measurements was correlated to the amount of corneal flattening; the latter could be predicted by multiple linear regression accounting for anterior and posterior corneal radii (P = .0002) and was correlated to the preoperative anterior/posterior ratio. CONCLUSIONS: Constant optimization is beneficial for combined DMEK and phacoemulsification. Predicting postoperative corneal flattening may improve the results of IOL power accuracy. [J Refract Surg. 2022;38(7):435-442.].


Asunto(s)
Catarata , Trasplante de Córnea , Lentes Intraoculares , Facoemulsificación , Biometría/métodos , Lámina Limitante Posterior , Humanos , Óptica y Fotónica , Facoemulsificación/métodos , Refracción Ocular , Estudios Retrospectivos
18.
Acta Ophthalmol ; 100(8): e1685-e1690, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35670319

RESUMEN

PURPOSE: To determine the utility of Split-Window optical coherence tomography OCT (SW-OCT) biometry in measuring ocular axial dimensions as well as imaging the intraocular lens (IOL) and posterior capsule in pseudophakic eyes. METHODS: Sixty-nine pseudophakic eyes of 69 subjects were enrolled in the study. The results of SW-OCT biometry implemented in the SD OCT device for posterior and anterior segment imaging (REVO NX, Optopol Technology) were compared with those obtained with the SS-OCT-based biometer IOLMaster 700 (Carl Zeiss Meditec). Differences in measurement values between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICC) and Bland-Altman plots. RESULTS: The correlation between measurements obtained with SW-OCT and SS-OCT was very high (ICC for: axial length (AL) = 1.000; anterior chamber depth (ACD) = 0.997; IOL thickness (IOL LT) = 0.997; central corneal thickness (CCT) = 0.987). The mean AL measurement difference was 0.003 ± 0.021 mm (the 95% LoA ranged from -0.04 to 0.05); the mean ACD difference was -0.009 ± 0.025 mm (95% LoA, -0.06 to 0.04); mean LT difference was 0.001 ± 0.021 mm (95% LoA, -0.04 to 0.04); and mean CCT difference was 1.4 ± 5.4 µm (95% LoA, -9 to 12). CONCLUSION: The study shows small, non-significant differences between the biometric measurements obtained with REVO NX SW-OCT and IOLMaster 700 SS-OCT in pseudophakic eyes. However, SW-OCT offered significantly lower ACD and LT measurement failure rates. With high-resolution imaging, SW-OCT enables accurate assessment of IOL position relative to the posterior capsule and visualization of capsular fibrosis.


Asunto(s)
Longitud Axial del Ojo , Lentes Intraoculares , Humanos , Longitud Axial del Ojo/anatomía & histología , Tomografía de Coherencia Óptica/métodos , Reproducibilidad de los Resultados , Biometría/métodos , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/anatomía & histología , Interferometría , Córnea
19.
J Cataract Refract Surg ; 48(11): 1292-1296, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-35616506

RESUMEN

PURPOSE: To compare phakic intraocular lens size calculations based on corneal diameter (CD) measurements by 3 instruments. SETTING: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. DESIGN: Retrospective interventional case series. METHODS: Preoperatively, CD was measured with the Aladdin, IOLMaster 700, and Pentacam AXL Wave. The simulated ICL size was computed by entering CD measurements into the manufacturer's calculator. Postoperatively, vaulting was measured by anterior segment optical coherence tomography. The optimal ICL size (OIS) was calculated and compared with the commercially available OIS (CAOIS). RESULTS: 54 eyes (29 patients) with the implantable collamer lens (ICL) were enrolled. The mean CD was 12.02 ± 0.36 mm with the Aladdin, 12.35 ± 0.39 mm with the IOLMaster 700, and 12.22 ± 0.41 mm with the Pentacam AXL Wave ( P &lt; .0001), with the closest agreement between the Pentacam AXL Wave and IOLMaster 700 (95% limits of agreement: -0.43 to +0.17 mm). Vaulting (mean: 558 ± 261 µm) was within 251 and 1000 µm in 49 eyes (83.3%). The mean difference between the simulated ICL size and OIS ranged between -0.11 ± 0.35 mm and 0.10 ± 0.30 mm ( P &lt; .0001), with no statistically significant difference between the IOLMaster 700 and Pentacam AXL Wave. The simulated ICL size was equal to CAOIS in 38 eyes (70.37%) with the Aladdin, 37 eyes (68.52%) with the IOLMaster 700, and 39 eyes (72.22%) with the Pentacam AXL Wave, without any statistically significant difference. CONCLUSIONS: CD measurements by the 3 devices lead to similar percentages of eyes with an ICL size equal to the OIS. Agreement is closer between the IOLMaster 700 and Pentacam AXL Wave.


Asunto(s)
Lentes Intraoculares Fáquicas , Humanos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Ojo , Italia
20.
J Cataract Refract Surg ; 48(8): 947-953, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35121684

RESUMEN

PURPOSE: To report the results of intraocular lens (IOL) power calculation by ray tracing in eyes with previous myopic excimer laser surgery. SETTING: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. DESIGN: Retrospective interventional case series. METHODS: A series of consecutive patients undergoing phacoemulsification and IOL implantation after myopic excimer laser was investigated. IOL power was calculated using ray-tracing software available on the anterior segment optical coherence tomographer MS-39. Axial length (AL) was measured by optical biometry, and 4 values were investigated: (1) that from the printout, (2) the modified Wang/Koch formula, and (3) the polynomial equation for the Holladay 1 and (4) for the Holladay 2 formulas. The mean prediction error (PE), median absolute error (MedAE), and percentage of eyes with a PE within ±0.50 diopters (D) were reported. RESULTS: The study enrolled 39 eyes. Entering the original AL into ray tracing led to a mean hyperopic PE (+0.56 ±0.54 D), whereas with the Wang/Koch formula, a mean myopic PE (-0.41 ±0.53 D) was obtained. The Holladay 1 and 2 polynomial equations lead to the lowest PEs (-0.10 ±0.49 D and +0.08 ±0.49 D, respectively), lowest MedAE (0.37 D and 0.25 D), and highest percentages of eyes with a PE within ±0.50 D (71.79% and 76.92%). Calculations based on the Holladay 2 polynomial equation showed a statistically significant difference compared with other methods used (including Barrett-True K formula), with the only exception of the Holladay 1 polynomial equation. CONCLUSIONS: IOL power was accurately calculated by ray tracing with adjusted AL according to the Holladay 2 polynomial equation.


Asunto(s)
Lentes Intraoculares , Miopía , Facoemulsificación , Biometría/métodos , Humanos , Láseres de Excímeros/uso terapéutico , Implantación de Lentes Intraoculares , Miopía/cirugía , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...