1.
Sci Adv ; 10(43): eadr1765, 2024 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-39454010

RESUMEN

Existing haptic actuators are often rigid and limited in their ability to replicate real-world tactile sensations. We present a wearable haptic artificial muscle skin (HAMS) based on fully soft, millimeter-scale, multilayer dielectric elastomer actuators (DEAs) capable of significant out-of-plane deformation, a capability that typically requires rigid or liquid biasing. The DEAs use a thickness-varying multilayer structure to achieve large out-of-plane displacement and force, maintaining comfort and wearability. Experimental results demonstrate that HAMS can produce complex tactile feedback with high perception accuracy. Moreover, we show that HAMS can be integrated into extended reality (XR) systems, enhancing immersion and offering potential applications in entertainment, education, and assistive technologies.


Asunto(s)
Piel Artificial , Humanos , Tacto , Dispositivos Electrónicos Vestibles , Músculo Esquelético/fisiología
2.
Adv Funct Mater ; 34(33)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39399303

RESUMEN

Stretchable electrodes are an essential component in soft actuator systems. In particular, Joule heating electrodes (JHEs) are required for thermal actuation systems. A highly stretchable, patternable, and low-voltage operating JHE based on hybrid layers of silver nanowires (AgNWs) and carbon nanotubes (CNTs) is reported. The conductive layers were applied on a locally pre-strained bistable electroactive polymer (BSEP) membrane to form a wrinkled conductive surface with a low resistance of 300 Ω/sq, and subsequently patterned to a serpentine trace by laser engraving. The resistance of the resulting electrode remains nearly unchanged up to ~80-90% area strain. By applying a voltage of 7 - 9 V to the electrode, the temperature of the BSEP membrane increased to more than 60 °C, well above the polymer's phase transition temperature of 46 °C, thereby lowering its modulus by a factor of 103. An electronic Braille device based on the JHEs on a BSEP membrane was assembled with a diaphragm chamber. The electrode was patterned into 3 × 2 individually addressable pixels according to the standard U.S. Braille cell format. Through Joule heating of the pixels and local expansion of the BSEP membrane using a small pneumatic pressure, the pixels deformed out of the plane by over 0.5 mm to display specific Braille letters. The Braille content can be refreshed for 20,000 cycles at the same operating voltage.

3.
Sci Rep ; 12(1): 19618, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36379969

RESUMEN

The erythrocyte sedimentation rate (ESR) is a non-specific blood test for determining inflammatory conditions. However, the long measurement time (60 min) to obtain ESR is an obstacle for a prompt evaluation. In this study, to reduce the measurement time of ESR, deep neural networks (DNNs) were applied to the sedimentation tendency of blood samples. DNNs using multilayer perceptron (MLP), long short-term memory (LSTM), and gated recurrent unit (GRU) were assessed and compared to determine a suitable length of time for the input sequence. To avoid overfitting, a stacking ensemble learning was adopted, which combines multiple models by using a meta model. Four meta models were compared: mean, median, least absolute shrinkage and selection operator, and partial least squares regression (PLSR) schemes. From the empirical results, LSTM and GRU models have better prediction than MLP over sequence lengths of 5 to 20 min. The decrease in [Formula: see text] and [Formula: see text] of GRU and LSTM was attenuated after a sequence length of 15 min, so the input sequence length is determined as 15 min. In terms of the meta model, the statistical comparison suggests that GRU combined with PLSR (GRU-PLSR) is the best case. Then, the GRU-PLSR was tested for prediction of ESR data obtained from periodontitis patients to check its applicability to a specific disease. The Bland-Altman plot shows acceptable agreement between measured and predicted ESR values. Based on the results, the GRU-PLSR can predict ESR with improved performance within 15 min and has potential applicability to ESR data with inflammatory and non-inflammatory conditions.


Asunto(s)
Redes Neurales de la Computación , Humanos , Sedimentación Sanguínea , Análisis de los Mínimos Cuadrados
4.
Sci Rep ; 12(1): 8986, 2022 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-35643726

RESUMEN

The formation of droplets or bubbles in a microfluidic system is a significant topic requiring device miniaturization and a small volume of samples. Especially, a two-phase segmented flow can be applied to micro-mixing for chemical reactions and the treatment of heat and mass transfer. In this study, a flow of liquid slugs and bubbles was generated in a 3D-printed chip and controlled by a single pump creating a vacuum at the outlet. The pump and chip device were integrated to form a simple and portable system. The size and flow rate of liquid slugs, obtained through image processing techniques, were analyzed considering several parameters related to hydraulic resistance and pressure drop. In addition, the effect of segmentation on mixing was observed by measuring the intensity change using two different colored inks. The hydraulic resistance of air and liquid flows can be controlled by changing the tube length of air flow and the viscosity of liquid flow. Because the total pressure drop along the channel was produced using a single pump at the outlet of the channel, the size and flow rate of the liquid slugs showed a near linear relation depending on the hydraulic resistances. In contrast, as the total pressure varied with the flow rate of the pump, the size of the liquid slugs showed a nonlinear trend. This indicates that the frequency of the liquid slug formation induced by the squeezed bubble may be affected by several forces during the development of the liquid slugs and bubbles. In addition, each volume of liquid slug segmented by the air is within the range of 10-1 to 2 µL for this microfluidic system. The segmentation contributes to mixing efficiency based on the increased homogeneity factor of liquid. This study provides a new insight to better understand the liquid slug or droplet formation and predict the segmented flow based on the relationship between the resistance, flow rate, and pressure drop.

5.
Int J Pharm ; 618: 121664, 2022 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-35292393

RESUMEN

A bolus of human growth hormone (hGH) is often prescribed for the treatment of growth hormone deficiency, which requires frequent injections in current clinical settings. This painful needle-involved delivery often results in poor patient compliance, leading to low medication adherence and poor clinical outcomes. Therefore, we propose a magnetically actuating implantable pump (MAP) that can infuse an accurate dose of hGH only at the time of non-invasive magnet application from the skin. The MAP herein could reproducibly infuse 20.6 ±â€¯0.9 µg hGH per actuation without any leak at times without actuation. The infused amount increased proportionally with an increase in the number of actuations. When the MAP was implanted and actuated with a magnet in animals with growth hormone deficiency for 21 days, the profiles of plasma hGH concentration and insulin-like growth factor (IGF)-1, as well as changes in body weight, were similar to those observed in animals treated with conventional subcutaneous hGH injections. Therefore, we anticipate that the MAP fabricated in this study can be a non-invasive alternative to administer hGH without repeated and frequent needle injections.


Asunto(s)
Hormona de Crecimiento Humana , Animales , Peso Corporal , Hormona del Crecimiento , Humanos , Inyecciones Subcutáneas , Factor I del Crecimiento Similar a la Insulina , Cumplimiento de la Medicación
6.
Anal Chem ; 91(21): 14109-14116, 2019 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-31556595

RESUMEN

In this study, we have established the separation of Au nanoparticles (AuNPs) using a symmetrical AC electric field applied-electrochemical microfluidic device composed of carbon channel and detection electrodes. The lateral movement of AuNPs in the channel under the AC field was analyzed by simulation using the mathematically derived equations, which were formulated from Newtonian fluid mechanics. It shows that the nanoparticles are precisely separated according to their respective mass or size difference in a short time. The experimental parameters affecting the separation and detection of AuNPs were optimized in terms of applied frequency, amplitude, flow rate, buffer concentration, pH dependency, and temperature. The final separation was performed at 1.0 V amplitude with 8.0 MHz frequency at 0.4 µL/min flow rate for the separation, and the potential of 1.0 V was applied for the amperometric detection of AuNPs in a 0.1 M PBS. Before and after the separation, AuNPs (diameter range: 3-60 nm) were confirmed by UV-visible spectroscopy and transmission electron microscopy. In this case, the separation resolution was 3 nm with an enhanced separation efficiency of up to 597,503 plates/m for the AuNPs. In addition, the amperometric current response of the detection electrode under the AC field application was also enhanced by the sensitivity 5-fold compared with the absence of the AC field.

7.
Biomicrofluidics ; 13(1): 014104, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30867875

RESUMEN

Considering the role of viscosity in the dynamics of physical, chemical, and biological systems, accurate measurement of viscosity is essential. Although many conventional viscometers have been widely used, these conventional viscometers suffer from some drawbacks. In this study, a three-dimensional (3D) printed microfluidic viscometer was proposed based on the estimation of the pressure between two fluids to easily measure viscosity with small samples. The 3D printed microfluidic viscometer can be fabricated through amine-epoxy bonding on 3D printed blocks. By separately delivering samples and reference fluids into two inlets, an interfacial line could be induced. Based on the relation between the pressure ratio and the width of the reference flow, the viscosity (µ) of the sample can be estimated by measuring the relative width of the reference flow. The relation between the pressure and interfacial width between test samples and reference flows in the 3D printed microfluidic viscometers was analyzed by experiment and simulation to determine the effects of the mesh-like pattern of the 3D printed viscometers on the pressure estimation. To validate the proposed method, the viscosity values of glycerol mixtures measured by the 3D printed viscometer were compared with those measured by a conventional viscometer. As an application of the 3D printed viscometer, the viscosity curves for blood samples collected from diabetic and non-diabetic patients depending on their shear rates were compared. As expected, a high blood viscosity in the diabetic group was observed. Based on the experimental demonstrations, the 3D printed viscometer has strong potential to develop portable viscometers that can be translated to commercial outcomes.

8.
PLoS One ; 14(1): e0210993, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30677055

RESUMEN

In studying blood flow in the vessels, the characteristics of non-Newtonian fluid are important, considering the role of viscosity in rheology. Stenosis, which is an abnormal narrowing of the vessel, has an influence on flow behavior. Therefore, analysis of blood flow in stenosed vessels is essential. However, most of them exist as simulation outcomes. In this study, non-Newtonian fluid was observed in stenosed microchannels under the pulsatile flow condition. A polydimethylsiloxane channel with 60% stenosis was fabricated by combining an optic fiber and a petri dish, resembling a mold. Three types of samples were prepared by changing the concentrations of xanthan gum, which induces a shear thinning effect (phosphate buffered saline (PBS) solution as the Newtonian fluid and two non-Newtonian fluids mimicking normal blood and highly viscous blood analog). The viscosity of the samples was measured using a Y-shaped microfluidic viscometer. Thereafter, velocity profiles were analyzed under the pulsatile flow condition using the micro-particle image velocimetry (PIV) method. For the Newtonian fluid, the streamline was skewed more to the wall of the channel. The velocity profile of the non-Newtonian fluid was generally blunter than that of the Newtonian fluid. A highly oscillating wall shear stress (WSS) during the pulsatile phase may be attributed to such a bluntness of flow under the same wall shear rate condition with the Newtonian fluid. In addition, a highly viscous flow contributes to the variation in the WSS after passing through the stenosed structures. A similar tendency was observed in simulation results. Such a variation in the WSS was associated with plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.


Asunto(s)
Viscosidad Sanguínea/fisiología , Microvasos/fisiología , Microvasos/fisiopatología , Modelos Cardiovasculares , Flujo Pulsátil/fisiología , Fenómenos Biomecánicos , Velocidad del Flujo Sanguíneo/fisiología , Simulación por Computador , Constricción Patológica , Dimetilpolisiloxanos , Hemorreología , Humanos , Estrés Mecánico
9.
PLoS One ; 12(10): e0186300, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29049327

RESUMEN

Spatial and temporal variations of the hemodynamic features occur under pulsatile conditions in complex vessel geometry. Wall shear stress affected by the disturbed flow can result in endothelial cell dysfunction, which leads to atherogenesis and thrombosis. Therefore, detailed understanding of the hemodynamic characteristics in a curved stenosed channel is highly important when examining the pathological effects of hemodynamic phenomena on the progression of atherosclerosis. The present study measures the velocity fields of pulsatile flows with three different Reynolds numbers in 3D curved vessel models with stenosis using time-resolved particle image velocimetry (PIV). Three different models were cast in PDMS polymer using models made by a 3D printer with different bend angles of 0°, 10°, and 20° between the longitudinal axes at the upstream and downstream of the stenosis. To investigate the 3D flow structures, a stack of 2D velocity fields was obtained by adjusting the position of the laser sheet along the Z-direction. The structures of flow fields in the stenosed models were analyzed using the distribution of the shearing strain as well as the skewness and full width at half maximum of the velocity profile. To support experiment results, distributions of pressure and 3D vortex in the curved stenosed channels were estimated by conducting the numerical simulation. These results indicate that the curvature of the tube considerably influences the skewness of the flow, and the shear stress is intensified near the outer curvature wall due to centrifugal force. The results would be helpful in understanding the effects of geometrical factors on plaque rupture and severe cardiovascular diseases.


Asunto(s)
Microfluídica , Modelos Teóricos , Impresión Tridimensional , Estrés Mecánico