Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742736

RESUMEN

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Falla de Prótesis , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ecocardiografía Transesofágica , Masculino , Resultado del Tratamiento , Femenino , Anciano , Reoperación
2.
Sci Rep ; 14(1): 697, 2024 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-38184738

RESUMEN

Metabolic syndrome (MetS) poses an additional risk for the development of coronary artery disease and major adverse cardiac and cerebrovascular events (MACCE). In this study, we investigated the association between MetS and its components and MACCE after percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS). The presence of MetS was calculated at baseline using the NCEP-ATP III criteria. The primary outcome was MACCE and its components were secondary outcomes. Unadjusted and adjusted Cox Regression models were used to calculate hazard ratios (HRs) and 95% confidence intervals (CI) of the association between MetS or its components and MACCE and its components. A total of 13,459 ACS patients who underwent PCI (MetS: 7939 and non-MetS: 5520) with a mean age of 62.7 ± 11.0 years (male: 72.5%) were included and median follow-up time was 378 days. Patients with MetS had significantly higher MACCE risk (adjusted HR [aHR] 1.22, 95% CI 1.08-1.39). The only component of MACCE that exhibited a significantly higher incidence in MetS patients was myocardial infarction (aHR 1.43, 95% CI 1.15-1.76). MetS components that were significantly associated with a higher incidence of MACCE were hypertension and impaired fasting glucose. Having three MetS components did not increase MACCE (aHR 1.12, 95% CI 0.96-1.30) while having four (aHR 1.32, 95% CI 1.13-1.55) or five (aHR 1.42, 95% CI 1.15-1.75) MetS components was associated with a higher incidence of MACCE. MetS was associated with a higher risk of MACCE in ACS patients undergoing PCI. Among MACCE components, myocardial infarction was significantly higher in patients with MetS. Impaired fasting glucose and hypertension were associated with a higher risk of MACCE. Identifying these patterns can guide clinicians in choosing appropriate preventive measures.


Asunto(s)
Síndrome Coronario Agudo , Hipertensión , Síndrome Metabólico , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Anciano , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/cirugía , Síndrome Metabólico/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Infarto del Miocardio/etiología , Glucosa
3.
Clin Auton Res ; 33(2): 165-189, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37119426

RESUMEN

PURPOSE: This systematic review aimed to evaluate the effect of transcutaneous auricular vagus nerve stimulation on heart rate variability and baroreflex sensitivity in healthy populations. METHOD: PubMed, Scopus, the Cochrane Library, Embase, and Web of Science were systematically searched for controlled trials that examined the effects of transcutaneous auricular vagus nerve stimulation on heart rate variability parameters and baroreflex sensitivity in apparently healthy individuals. Two independent researchers screened the search results, extracted the data, and evaluated the quality of the included studies. RESULTS: From 2458 screened studies, 21 were included. Compared with baseline measures or the comparison group, significant changes in the standard deviation of NN intervals, the root mean square of successive RR intervals, the proportion of consecutive RR intervals that differ by more than 50 ms, high-frequency power, low-frequency to high-frequency ratio, and low-frequency power were found in 86%, 75%, 69%, 47%, 36%, and 25% of the studies evaluating the effects of transcutaneous auricular vagus nerve stimulation on these indices, respectively. Baroreflex sensitivity was evaluated in six studies, of which a significant change was detected in only one. Some studies have shown that the worse the basic autonomic function, the better the response to transcutaneous auricular vagus nerve stimulation. CONCLUSION: The results were mixed, which may be mainly attributable to the heterogeneity of the study designs and stimulation delivery dosages. Thus, future studies with comparable designs are required to determine the optimal stimulation parameters and clarify the significance of autonomic indices as a reliable marker of neuromodulation responsiveness.


Asunto(s)
Estimulación del Nervio Vago , Humanos , Estimulación del Nervio Vago/métodos , Frecuencia Cardíaca/fisiología , Barorreflejo/fisiología , Voluntarios Sanos , Nervio Vago/fisiología
4.
Heart Fail Rev ; 28(1): 1-19, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35596876

RESUMEN

Thirty years ago, patients with low ejection fraction (EF) have often been excluded from rehabilitation programs due to concern about possibility of sudden death or other adverse cardiovascular events during exercise sessions. Recent studies have highlighted the fact that cardiac rehabilitation could improve exercise capacity, cardiac function, and health-related quality of life in congestive heart failure patients. This encouraged us to write a review article and update our latest knowledge about the outcome of rehabilitation program in patients with severely depressed cardiac function. We were particularly interested in effect of cardiac rehabilitation on exercise capacity, quality of life, vascular effects, neuro-hormonal changes, and mortality. We also conducted a mini-systematic review and meta-analysis on randomized controlled trials comparing exercise training with usual care in patients with severely reduced left ventricular ejection fraction, for the mortality subsection to obtain precise estimates of overall treatment benefit on mortality. It is our privilege to submit our manuscript for possible publication in your prestigious journal.


Asunto(s)
Rehabilitación Cardiaca , Insuficiencia Cardíaca , Humanos , Calidad de Vida , Volumen Sistólico , Función Ventricular Izquierda , Terapia por Ejercicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA