1.
J Orthop Surg Res ; 18(1): 948, 2023 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-38071336

RESUMEN

BACKGROUND: Three-dimensional computed-tomography (3D-CT) planning for primary Total Hip Arthroplasty (THA) typically uses the external femoral surface; as a result, it is difficult to predict the prosthetic femoral version (PFV) for uncemented femoral stems that press-fit to the internal surface of the bone. Cemented fixation allows the surgeon to adjust the version independent of the internal femoral anatomy. We aimed to better understand the effect of the fixation type on PFV. METHODS: This was a case series study including a total of 95 consecutive patients (106 hips), who underwent uncemented (n = 81 hips) and cemented (n = 25 hips) primary THA using the posterior approach. The surgeon aimed for a PFV of 20°. Our primary objective was to compare PFV in both groups; our secondary objective was to evaluate the clinical outcomes. RESULTS: The mean (± SD) PFV was 13° (± 9°) and 23° (± 8°) for the uncemented and cemented THA groups (P < 0.001), respectively. In the uncemented THA group, 36% of the patients had a PFV of < 10°. In the cemented THA group, this clinically important threshold dropped to 8%. Similarly, the Bland-Altman (BA) plots showed wider 95% limits of agreement for the uncemented group. Satisfactory clinical outcomes were recorded. CONCLUSION: We found that the PFV was more clinically acceptable, for the posterior surgical approach, in the cemented group when compared to the uncemented group. Both THA groups reported high variability indicating the need to develop surgical tools to guide the PFV closer to the surgical target.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Falla de Prótesis , Diseño de Prótesis , Resultado del Tratamiento
2.
Arthroplast Today ; 23: 101184, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37745962

RESUMEN

Background: Acrylic-based bone cement (polymethyl methacrylate [PMMA]) is a material commonly used in orthopaedic surgeries; however, during PMMA polymerization, a highly exothermic reaction occurs. The heat released in polymerization can damage nearby materials including poorly heat-resistant cross-linked polyethylene (XLPE). Both PMMA and XLPE are used in total hip arthroplasty and could interact during femoral stem fixation. We sought to determine if the exothermic polymerization of PMMA could alter the surface characteristics of XLPE acetabular liners. Methods: Six XLPE liners were assigned to one of 4 experimental categories with varying volumes of PMMA applied in a manner that mimicked how the 2 materials would come into contact intraoperatively. Measurements were taken both pre- and post-intervention using a coordinate measuring machine for geometric and gravimetric analysis. Light microscopy was conducted postintervention to examine the surface for damage. Results: Coordinate measuring machine measurements showed minimal gross deformation in all 6 liners, but there were isolated surface deposits in 4 of 6 liners. The average maximal surface deviations, when compared to the control, for liners exposed to 1 cc of cement, 2 cc of cement, or 1 cc of cement with a femoral head implant attached were 26.6 µm, 77.2 µm, and 26.4 µm, respectively. All but one liner showed an increase in volume following intervention when compared to the control. Subtle scratches were identified using light microscopy on all 6 liners. Conclusions: XLPE shows areas of isolated surface deformation in a dose-dependent manner but with minimal gross deformation after interacting with highly exothermic PMMA.

3.
J Orthop ; 42: 63-69, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37519912

RESUMEN

Background and aims: The treatment of early onset scoliosis is a challenge. Some curves resolve spontaneously, while the more aggressive ones require surgical intervention. Several surgical strategies have been explored in this unique group of patients, though the distraction based growing rods are the mainstay of treatment. The aim of this paper is to consider the current scenario with the surgical treatment for early onset scoliosis with growing rods. Methods: This is a narrative review that explores the various types of growing rod options that are currently available. The results, as reported in literature, are discussed. The complications and problems with the commonly used growing rods are explored, based on the reported literature and on retrieval analysis that we have published. We discuss some of the newer modifications of growing rods. Results: There is no real consensus on the ideal timing for the surgery or ways to assess the outcomes of the treatment. The Cobb angle measurement and measures of thoracic growth are surrogate markers. The main indication for surgery is to an increase in the thoracic dimensions and allowing for lung growth. Measures that are linked to lung function are more useful. We report some newer MRI scanning technology. Distraction-based growing rods have been reported to produce consistent and good results. Frequent return to theatre with the Traditional Growing Rods (TGR) and the metallosis related problems with the MCGR are reported. Conclusions: We have learned a lot from the TGR and MCGR experiences. There is a scope for ongoing research to improve the design of the implant systems and better assess the outcomes on lung function. This review outlines these and helps identify the future trends.

4.
J Pediatr Orthop ; 43(8): 486-491, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37340610

RESUMEN

BACKGROUND: Magnetically controlled growing rods (MCGRs) have a known issue with fracture of the internal locking pin resulting in early revisions. The manufacturer reported that rods manufactured before March 26, 2015, had a 5% risk of locking pin fracture. Locking pins made after this date are thicker in diameter and of a tougher alloy; their rate of pin fracture is not known. The aim of this study was to better understand the impact of the design changes on the performance of MCGRs. METHODS: This study involves 46 patients with 76 removed MCGRs. Forty-six rods were manufactured before March 26, 2015, and 30 rods after that date. Clinical and implant data were collected for all MCGRs. Retrieval analysis comprised plain radiographs evaluations, force and elongation testing, and disassembly. RESULTS: The 2 patient groups were statistically comparable. We found that 14 of 27 patients implanted with rods manufactured before March 26, 2015 (group I) had a fracture of their locking pins. Three of the 17 patients with rods manufactured after this date (group II) were also found to have a fractured pin. CONCLUSIONS: Retrieved rods collected at our center and made after March 26, 2015, had far fewer locking pin fractures than those made before this date; this may be due to the change in pin design.


Asunto(s)
Fracturas Óseas , Escoliosis , Humanos , Prótesis e Implantes , Radiografía , Gravitación
5.
Front Bioeng Biotechnol ; 11: 1150061, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37187883

RESUMEN

The placement of acetabular implant components determines the short- and long-term outcomes of total hip replacement (THR) and a number of tools have been developed to assist the surgeon in achieving cup orientation to match the surgical plan. However, the accuracy and precision of 3D-CT for the measurement of acetabular component position and orientation is yet to be established. To investigate this, we compared measurements of cobalt chrome acetabular components implanted into 2 different bony pelvic models between a coordinate measuring Faro arm and 3 different low dose CT images, including 3D-CT, 2D anterior pelvic plane (APP) referenced CT and 2D scanner referenced (SR) CT. Intra-observer differences were assessed using the Intraclass correlation coefficient (ICC). The effect of imaging the pelvis positioned in 3 different orientations within the CT scanner was also assessed. The measured parameters were the angles of inclination and version. 3D-CT measurements were found to closely match the "true values" of the component position measurements, compared with the 2D-CT methods. ICC analysis also showed good agreement between the coordinate measuring arm (CMA) and 3D-CT but poor agreement between the 2D SR method, in the results from two observers. When using the coordinate system of the CT scanner, the measurements consistently produced the greatest error; this method yielded values up to 34° different from the reference digitising arm. However, the difference between the true inclination and version angles and those measured from 3D APP CT was below half a degree in all cases. We concluded that low radiation dose 3D-CT is a validated reference standard for the measurement of acetabular cup orientation.

6.
J Orthop Res ; 41(9): 2016-2025, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36912127

RESUMEN

The assessment of three-dimensional bony defects is important to inform the surgical planning of hip reconstruction. Mirroring of the contralateral side has been previously used to measure the hip center of rotation (CoR). However, the contralateral side may not be useful when diseased or replaced. Statistical Shape Models (SSMs) can aid reconstruction of patient anatomy. Previous studies have been limited to computational models only or small patient cohorts. We used SSM as a tool to help derive landmarks that are often absent in hip joints of patients with large acetabular defects. Our aim was to compare the reconstructed pelvis with patients who have previously undergone hip revision. This retrospective cohort study involved 38 patients with Paprosky type IIIB defects. An SSM was built on 50 healthy pelvises and used to virtually reconstruct the native pelvic morphology for all cases. The outcome measures were the difference in CoR for (1) SSM versus diseased hip, (2) SSM versus plan, and (3) SSM versus contralateral healthy hip. The median differences in CoR were 31.17 mm (interquartile range [IQR]: 43.80-19.87 mm), 8.53 mm (IQR: 12.76-5.74 mm), and 7.84 mm (IQR: 10.13-5.13 mm), respectively. No statistical difference (p > 0.05) was found between the SSM versus plan and the SSM versus contralateral CoRs. Our findings show that the SSM model can be used to reconstruct the absent bony landmarks of patients with significant lysis regardless of the defect severity, hence aiding the surgical planning of hip reconstruction and implant design.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Reoperación , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Acetábulo/cirugía
7.
J Pediatr Orthop ; 43(4): 211-217, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36737055

RESUMEN

BACKGROUND: The mechanisms of fracture in magnetically controlled growing rods (MCGRs) and the risk factors associated with this are poorly understood. This retrospective analysis of explanted MCGRs aimed to add understanding to this subject. METHODS: From our cohort of over 120 retrieved MCGRs, we identified 7 rods that had fractured; all were single-rod constructs, retrieved from 6 patients. These were examined and compared with 15 intact single-rod constructs. Retrieval and fractographic analyses were used to determine the failure mode at the fracture site and the implant's functionality. Cobb angle, degree of rod contouring, and the distance between anchoring points were computed on anteroposterior and lateral radiographs. RESULTS: 5/7 versus 3/15 rods had been inserted after the removal of a previously inserted rod, in the fractured versus control groups. All fractured rods failed due to bending fatigue. Fractured rods had greater rod contouring angles in the frontal plane ( P = 0.0407) and lateral plane ( P = 0.0306), and greater distances between anchoring points in both anteroposterior and lateral planes ( P = 0.0061 and P = 0.0074, respectively). CONCLUSIONS: We found all failed due to a fatigue fracture and were virtually all single rod configurations. Fracture initiation points corresponded with mechanical indentation marks induced by the intraoperative rod contouring tool. Fractured rods had undergone greater rod contouring and had greater distances between anchoring points, suggesting that it is preferable to implant double rod constructs in patients with sufficient spinal maturity to avoid this complication. CLINICAL RELEVANCE: Level III.


Asunto(s)
Fracturas Óseas , Escoliosis , Fusión Vertebral , Humanos , Escoliosis/cirugía , Estudios Retrospectivos , Columna Vertebral/cirugía , Prótesis e Implantes , Fracturas Óseas/cirugía , Fracturas Óseas/etiología , Fusión Vertebral/efectos adversos
8.
J Orthop Res ; 41(7): 1505-1516, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36370140

RESUMEN

Three-dimensional (3D) printing is used to manufacture custom acetabular cups to treat patients with massive acetabular defects. There is a risk of defects occurring in these, often in the form of structural voids. Our aim was to investigate the presence of voids in commercially available cups. We examined 12, final-production titanium custom acetabular cups, that had been 3D-printed by six manufacturers. We measured their mass, then performed micro-computed tomography (micro-CT) imaging to determine their volume and density. The micro-CT data were examined for the presence of voids. In cups that had voids, we computed (1) the number of voids, (2) their volume and the cup volume fraction, (3) their sphericity, (4) size, and (5) their location. The cups had median mass, volume, and density of 208.5 g, 46,471 mm3 , and 4.42 g/cm3 , respectively. Five cups were found to contain a median (range) of 90 (58-101) structural voids. The median void volume and cup volume fractions of cups with voids were 5.17 (1.05-17.33) mm3 and 99.983 (99.972-99.998)%, respectively. The median void sphericity and size were 0.47 (0.19-0.65) and 0.64 (0.27-8.82) mm, respectively. Voids were predominantly located adjacent to screw holes, within flanges, and at the transition between design features; these were between 0.17 and 4.66 mm from the cup surfaces. This is the first study to examine defects within final-production 3D-printed custom cups, providing data for regulators, surgeons, and manufacturers about the variability in final print quality. The size, shape, and location of these voids are such that there may be an increased risk of crack initiation from them.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Microtomografía por Rayos X , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Impresión Tridimensional
9.
Bioengineering (Basel) ; 9(11)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36354578

RESUMEN

Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the accuracy of a patient-specific (PS) femoral osteotomy guide in primary THA using three-dimensional (3D) computed tomography (CT) analysis. We included pre- and post-operative CT data of 103 THAs. All patients underwent 3D planning to define the optimal femoral neck osteotomy level. Our primary objective was to quantify the discrepancy between the achieved and planned osteotomy level; our secondary objective was to evaluate the clinical outcome. The median (Interquartile Range­IQR) discrepancy between the achieved and planned osteotomy level was 0.3 mm (−1 mm to 2 mm). We found a strong positive correlation between the planned and achieved osteotomy level (R2 = 0.9, p < 0.001). A satisfactory clinical outcome was recorded. Our findings suggest that surgeons can use 3D-printed PS guides to achieve a femoral neck osteotomy with a high level of accuracy to the plan.

10.
3D Print Med ; 8(1): 33, 2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36342573

RESUMEN

BACKGROUND: 3D printed patient-specific titanium acetabular cups are used to treat patients with massive acetabular defects. These have highly porous surfaces, with the design intent of enhancing bony fixation. Our aim was to characterise these porous structures in commercially available designs. METHODS: We obtained 12 final-production, patient-specific 3D printed acetabular cups that had been produced by 6 manufacturers. High resolution micro-CT imaging was used to characterise morphometric features of their porous structures: (1) strut thickness, 2) the depth of the porous layer, (3) pore size and (4) the level of porosity. Additionally, we computed the surface area of each component to quantify how much titanium may be in contact with patient tissue. Statistical comparisons were made between the designs. RESULTS: We found a variability between designs in relation to the thickness of the struts (0.28 to 0.65 mm), how deep the porous layers are (0.57 to 11.51 mm), the pore size (0.74 to 1.87 mm) and the level of porosity (34 to 85%). One manufacturer printed structures with different porosities between the body and flange; another manufacturer had two differing porous regions within the body of the cups. The cups had a median (range) surface area of 756.5 mm2 (348 - 1724). CONCLUSIONS: There is a wide variability between manufacturers in the porous titanium structures they 3D print. We do not currently know whether there is an optimal porosity and how this variability will impact clinically on the integrity of bony fixation; this will become clearer as post market surveillance data is generated.

11.
BMC Musculoskelet Disord ; 23(1): 783, 2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-35974363

RESUMEN

BACKGROUND: Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. METHODS: This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism ("spine rods", n = 18), long bone tumour implants ("tumour implants", n = 13) and 3D-printed customised massive acetabular defect implants ("massive acetabular implants", n = 10). This data was compared with standard, uncemented primary titanium hip implants ("standard hips", 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. RESULTS: The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6-4.9), 9.7 ppb (4.0-25.4), 2.6 ppb (0.4-104.4) and 5.7 ppb (1.6-31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). CONCLUSION: This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo , Cobalto , Prótesis de Cadera/efectos adversos , Humanos , Metales , Diseño de Prótesis , Titanio/efectos adversos
12.
BMC Musculoskelet Disord ; 23(1): 474, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35590296

RESUMEN

BACKGROUND: With the Persona® knee system a novel anatomic total knee design was developed, which has no pre-coating, whereas the predecessor knee system is pre-coated with polymethylmethacrylate (PMMA). Joint registry data have shown no decrease in risk of aseptic revision of PMMA pre-coated tibial components compared with non-pre-coated implants. The aim of this retrieval study was to compare the amount of cement adhesions, geometry and surface features between the two knee designs and to correlate them with the underlying reason for revision surgery. METHODS: Retrieval analysis was performed of 15 NexGen® and 8 Persona® fixed-bearing knee implants from the same manufacturer retrieved from two knee revision centres. A photogrammetric method was used to grade the amount of cement attached to the tibial tray backside. The geometry and dimensions of the tibial trays, tray projections and peripheral lips were measured using digital callipers and compared between the two different designs. To measure the surface roughness on the backside of the tibial tray, a contact profilometer was used. To investigate differences between the two designs statistical analyses (t-test) were performed. RESULTS: All Persona® trays showed evidence of cement adhesion with a % area of 75.4%; half of the NexGen® trays had cement adhesions, with a mean value of 20%. There was a significant difference in the percentage of area covered by cement between the two designs (p < 0.001). Results from the contact profilometer revealed that Persona® and NexGen® tray backsides showed a similar lateral (1.36 µm and 1.10 µm) and medial (1.39 µm and 1.12 µm) mean surface roughness with significant differentiation (p < 0.05) of the lateral and medial roughness values between the two designs. Persona® stems showed a significantly higher mean surface roughness (1.26) compared to NexGen® stems (0.89; p < 0.05). CONCLUSION: The novel anatomic knee system showed significantly more cements adhesions and a higher surface roughness which was most likely attributed to the most obvious design and coating alteration of the tibial tray. This study provides first retrieval findings of a novel TKA design recently introduced to the market.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Humanos , Polietileno , Polimetil Metacrilato , Diseño de Prótesis , Falla de Prótesis , Tibia/cirugía
13.
Bone Jt Open ; 3(2): 155-157, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35172606

RESUMEN

MAGnetic Expansion Control (MAGEC) rods are used in the surgical treatment of children with early onset scoliosis. The magnetically controlled lengthening mechanism enables rod distractions without the need for repeated invasive surgery. The CE certification of these devices was suspended in March 2021 due, primarily, to performance evidence gaps in the documents provided by the manufacturer to regulators and notified bodies. MAGEC rods are therefore not permitted for use in countries requiring CE marking. This was a survey of 18 MAGEC rod surgeons in the UK about their perception of the impact of the CE suspension on the clinical management of their patients. Unsurprisingly, virtually all perceived a negative impact, reflecting the complexity of this patient group. Reassuringly, these surgeons are highly experienced in alternative treatment methods. Cite this article: Bone Jt Open 2022;3(2):155-157.

14.
Tomography ; 8(1): 180-188, 2022 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-35076625

RESUMEN

BACKGROUND: SPECT/CT distribution patterns in patients with total knee replacements have previously been correlated with factors such as time of implantation, implant type and alignment. It is unknown, however, if an increased and more extended bone tracer uptake (BTU) in SPECT/CT, representing loading of the joint, correlates with findings from retrieval studies. The aim of this study was to further understand this subject. MATERIALS AND METHODS: 62 retrieved TKA were included. SPECT/CT was performed prior to revision. Quantitative and qualitative medio-lateral comparisons of BTU intensity and distribution in the tibia were performed. Retrieval analysis was performed with a micro-CT method to assess the thickness differences between medial and lateral sides of polyethylene inserts with symmetrical designs. RESULTS: In the subgroup of TKA with asymmetrical SPECT/CT distribution, there was a significant correlation between retrieval and medical imaging data (p = 0.0355): patients showing a more extended BTU in the medial compartment also had a significantly thinner insert in the medial compartment, and vice versa in the lateral side. CONCLUSION: This is the first study comparing BTU distribution patterns and retrieval findings. Our results support the hypothesis that SPECT/CT is able to identify bone activity due to implant position and loading.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Polietileno , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único
16.
Hip Int ; 32(5): 677-684, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33322929

RESUMEN

BACKGROUND: Modularity of metal-on-metal (MoM) implants has come under scrutiny due to concerns regarding additional sources of metal debris. This study is a retrieval analysis of implants from the same manufacturer with the same MoM bearing surface. The difference between the implants was presence or absence of modular junctions. METHODS: This is a retrospective study of 31 retrieved implants from 31 patients who received a Conserve Wright Medical MoM hip prosthesis. The 31 implants consisted of 16 resurfacings and 15 implants with modular junctions; 4 conventional THAs and 11 modular-neck THAs. RESULTS: 43% of pre-revision MRI scans performed on resurfacing implants and 91% performed on the modular implants illustrated evidence of an adverse local tissue reaction. There was no difference in pre-revision blood metal ion levels or bearing surface wear between the resurfacings and modular implants. The neck-head tapers of the modular group showed low levels of material loss. However, the neck-stem tapers showed increased severity of corrosion and material loss. CONCLUSIONS: The modular implants had an increased incidence of adverse local tissue reaction. This could be related to the presence of modular junctions, particular the neck-stem junction which showed increased susceptibly to corrosion.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Artroplastia de Reemplazo de Cadera/efectos adversos , Corrosión , Prótesis de Cadera/efectos adversos , Humanos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos
17.
Bioengineering (Basel) ; 10(1)2022 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-36671617

RESUMEN

Edge-wear in acetabular cups is known to be correlated with greater volumes of material loss; the location of this wear pattern in vivo is less understood. Statistical shape modelling (SSM) may provide further insight into this. This study aimed to identify the most common locations of wear in vivo, by combining CT imaging, retrieval analysis and SMM. Shape variance was described in 20 retrieved metal-on-metal acetabular surfaces. These were revised after a mean of 90 months, from 13 female and seven male patients. They were positioned with a mean inclination and anteversion of 53° and 30°, respectively. Their orientation, in vivo, was established using their stabilising fins, visible in pre-revision CT imaging. The impact of wear volume, positioning, time, gender and size on the in vivo location of wear was investigated. These surfaces had a mean wear volume of 49.63 mm3. The mean acetabular surface displayed superior edge-wear centred 7° within the posterosuperior quadrant, while more of the volumetric wear occurred in the anterosuperior quadrant. Components with higher inclination had greater superior edge-wear scars, while a relationship was observed between greater anteversion angles and more posterosuperior edge-wear. This SSM method can further our understanding of hip implant function, informing future design and may help to refine the safe zone for implant positioning.

18.
BMC Musculoskelet Disord ; 22(1): 1003, 2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34847880

RESUMEN

BACKGROUND: With the Persona® knee system a new polyethylene formulation incorporating vitamin-E which aims to reduce oxidation and maintain wear resistance was introduced. Although in-vitro studies have demonstrated positive effects of the vitamin-E antioxidants on UHMWPE, no retrieval study has looked at polyethylene damage of this system yet. It was the aim to investigate the in-vivo performance of this new design, by comparing it with its predecessor in retrieval analysis. METHODS: 15 NexGen® and 8 Persona® fixed-bearing implants from the same manufacturer (Zimmer Biomet) were retrieved from two knee revision centres. For retrieval analysis, a macroscopic analysis of polyethylene using a peer-reviewed damage grading method was used (Hood-score). The roughness of all articulating metal components was measured using a contact profilometer. The reason(s) for TKA revision were recorded. Statistical analyses (t-test) were performed to investigate differences between the two designs. RESULTS: The mean Hood score for Persona® inserts was 109.3 and for NexGen® 115.1 without significant differences between the two designs. Results from the profilometer revealed that Persona® and NexGen® femoral implants showed an identical mean surface roughness of 0.14 µm. The Persona® tibial tray showed a significantly smoother surface (0.06 µm) compared to the NexGen® (0.2 µm; p < 0.001). Both Hood score and surface roughness were influenced by the reasons for revision (p < 0.01). CONCLUSIONS: The bonding of the antioxidant vitamin-E to the PE chain used in the novel Persona® knee system does not reduce in-vivo surface damage compared to highly crosslinked PE without supplemented vitamin-E used in its predecessor knee system NexGen®. However, the Persona® titanium alloy tibial tray showed a significantly smoother surface in comparison to the NexGen® titanium alloy tibial tray. This study provides first retrieval findings of a novel TKA design and may help to understand how the new Persona® anatomic knee system performs in vivo.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Antioxidantes , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Prótesis de la Rodilla/efectos adversos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Vitamina E , Vitaminas
19.
Bone Joint Res ; 10(10): 639-649, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34605661

RESUMEN

AIMS: Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning. METHODS: 3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham hip replacements (BHRs) allowed the co-registration of their acetabular wear maps and their computational models, segmented from CT scans. The in vivo location of edge-wear was measured within a standardized coordinate system, defined using the anterior pelvic plane. RESULTS: Edge-wear was found predominantly along the superior acetabular edge in all cases, while its median location was 8° (interquartile range (IQR) -59° to 25°) within the anterosuperior quadrant. The deepest point of these scars had a median location of 16° (IQR -58° to 26°), which was statistically comparable to their centres (p = 0.496). Edge-wear was in closer proximity to the superior apex of the cups with greater angles of acetabular inclination, while a greater degree of anteversion influenced a more anteriorly centred scar. CONCLUSION: The anterosuperior location of edge-wear was comparable to the degradation patterns observed in acetabular cartilage, supporting previous findings that hip joint forces are directed anteriorly during a greater portion of walking gait. The further application of this novel method could improve the current definition of optimal and safe acetabular component positioning. Cite this article: Bone Joint Res 2021;10(10):639-649.

20.
Bone Jt Open ; 2(8): 599-610, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34352183

RESUMEN

AIMS: The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. METHODS: We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. RESULTS: All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate - severe junction corrosion. CONCLUSION: We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599-610.