Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Circ Heart Fail ; 8(2): 286-94, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25344549

RESUMEN

BACKGROUND: Exercise capacity as measured by peak oxygen uptake (Vo2) is similarly impaired in patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with reduced ejection fraction (HFrEF). However, characterization of how each component of Vo2 changes in response to incremental exercise in HFpEF versus HFrEF has not been previously defined. We hypothesized that abnormally low peripheral o2 extraction (arterio-mixed venous o2 content difference, [C(a-v)o2]) during exercise significantly contributes to impaired exercise capacity in HFpEF. METHODS AND RESULTS: We performed maximum incremental cardiopulmonary exercise testing with invasive hemodynamic monitoring on 104 patients with symptomatic NYHA II to IV heart failure (HFpEF, n=48, peak Vo2=13.9±0.5 mL kg(-1) min(-1), mean±SEM, and HFrEF, n=56, peak Vo2=12.1±0.5 mL kg(-1) min(-1)) and 24 control subjects (peak Vo2 27.0±1.7 mL kg(-1) min(-1)). Peak exercise C(a-v)o2 was lower in HFpEF compared with HFrEF (11.5±0.27 versus 13.5±0.34 mL/dL, respectively, P<0.0001), despite no differences in age, hemoglobin level, peak respiratory exchange ratio, Cao2, or cardiac filling pressures. Peak C(a-v)o2 and peak heart rate emerged as the leading predictors of peak Vo2 in HFpEF. Impaired peripheral o2 extraction was the predominant limiting factor to exercise capacity in 40% of patients with HFpEF and was closely related to elevated systemic blood pressure during exercise (r=0.49, P=0.0005). CONCLUSIONS: In the first study to directly measure C(a-v)o2 throughout exercise in HFpEF, HFrEF, and normals, we found that peak C(a-v)o2 was a major determinant of exercise capacity in HFpEF. The important functional limitation imposed by impaired o2 extraction may reflect intrinsic abnormalities in skeletal muscle or peripheral microvascular function, and represents a potential target for therapeutic intervention.


Asunto(s)
Tolerancia al Ejercicio/fisiología , Insuficiencia Cardíaca/fisiopatología , Consumo de Oxígeno/fisiología , Anciano , Ejercicio Físico/fisiología , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Intercambio Gaseoso Pulmonar/fisiología , Volumen Sistólico/fisiología
2.
Circ Heart Fail ; 6(3): 499-507, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23572493

RESUMEN

BACKGROUND: In patients with left ventricular systolic dysfunction (LVSD), the rate at which oxygen uptake (VO2) increases on initiation of exercise is inadequate to match metabolic demands. To gain mechanistic insights into delayed VO2 kinetics in LVSD, we simultaneously assessed hemodynamic measurements, ventilatory parameters, and peripheral oxygen usage during exercise. METHODS AND RESULTS: Forty-two patients with symptomatic LVSD (age, 59±2 years [mean±SEM]; LV ejection fraction, 30±1%) and 17 controls (LV ejection fraction, 68±1%) underwent maximum upright cycle ergometry cardiopulmonary exercise testing. Hemodynamic monitoring and first-pass radionuclide ventriculography were performed at rest and during exercise. VO2 kinetics were quantified by mean response time (MRT), which was significantly longer in patients with LVSD compared with controls (64±3 versus 45±5 s; P=0.004). In LVSD patients, MRT was associated with higher biventricular filling pressures and reduced cardiac output during early exercise. LVSD patients with MRT ≥60 s, compared with LVSD subjects with MRT <60 s, demonstrated greater impairment in right ventricular-pulmonary vascular function during exercise as evidenced by lower right ventricular ejection fraction (35±2 versus 45±2%; P=0.03), steeper increment in transpulmonary gradient relative to cardiac output (3.7 versus 2.2 mm Hg/L; P<0.001), and increased ventilatory dead-space fraction (17±1 versus 12±2%; P=0.03). In contrast, MRT was not associated with LV ejection fraction (rest, exercise), PaO2, hemoglobin, or resting pulmonary function test results. CONCLUSIONS: Delayed oxygen uptake on initiation of exercise (ie, MRT ≥60 s) in LVSD is closely related to impaired right ventricular-pulmonary vascular function and may represent an important surrogate for inability to augment RV performance during physical activity in patients with heart failure.


Asunto(s)
Ejercicio Físico/fisiología , Insuficiencia Cardíaca Sistólica/fisiopatología , Consumo de Oxígeno/fisiología , Circulación Pulmonar/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Factores de Tiempo , Ventriculografía de Primer Paso
3.
Circulation ; 124(13): 1442-51, 2011 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-21875912

RESUMEN

BACKGROUND: Exercise oscillatory ventilation (EOV) is a noninvasive parameter that potently predicts outcomes in systolic heart failure (HF). However, mechanistic insights into EOV have been limited by the absence of studies relating EOV to invasive hemodynamic measurements and blood gases performed during exercise. METHODS AND RESULTS: Fifty-six patients with systolic HF (mean±SEM age, 59±2 years; left ventricular ejection fraction, 30±1%) and 19 age-matched control subjects were studied with incremental cardiopulmonary exercise testing. Fick cardiac outputs, filling pressures, and arterial blood gases were measured at 1-minute intervals during exercise. We detected EOV in 45% of HF (HF+EOV) patients and in none of the control subjects. The HF+EOV group did not differ from the HF patients without EOV (HF-EOV) in age, sex, body mass index, left ventricular ejection fraction, or origin of HF. Univariate predictors of the presence of EOV in HF, among measurements performed during exercise, included higher right atrial pressure and pulmonary capillary wedge pressure and lower cardiac index (CI) but not Paco2 or Pao2. Multivariate logistic regression identified that low exercise CI is the strongest predictor of EOV (odds ratio, 1.39 for each 1.0-L · min(-1) · m(-2) decrement in CI; 95% confidence interval, 1.14-1.70; P=0.001). Among HF patients with EOV, exercise CI was inversely related to EOV cycle length (R=-0.71) and amplitude (R=-0.60; both P<0.001). In 11 HF+EOV subjects treated with 12 weeks of sildenafil, EOV cycle length and amplitude decreased proportionately to increases in CI. CONCLUSION: Exercise oscillatory ventilation is closely related to reduced CI and elevated filling pressures during exercise and may be an important surrogate for exercise-induced hemodynamic impairment in HF patients. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00309790.


Asunto(s)
Prueba de Esfuerzo/métodos , Insuficiencia Cardíaca Sistólica , Piperazinas/uso terapéutico , Mecánica Respiratoria/fisiología , Sulfonas/uso terapéutico , Análisis de los Gases de la Sangre , Dióxido de Carbono/sangre , Gasto Cardíaco/efectos de los fármacos , Gasto Cardíaco/fisiología , Prueba de Esfuerzo/efectos de los fármacos , Femenino , Insuficiencia Cardíaca Sistólica/diagnóstico , Insuficiencia Cardíaca Sistólica/tratamiento farmacológico , Insuficiencia Cardíaca Sistólica/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Inhibidores de Fosfodiesterasa 5/uso terapéutico , Esfuerzo Físico/fisiología , Valor Predictivo de las Pruebas , Intercambio Gaseoso Pulmonar/efectos de los fármacos , Intercambio Gaseoso Pulmonar/fisiología , Presión Esfenoidal Pulmonar/efectos de los fármacos , Presión Esfenoidal Pulmonar/fisiología , Purinas/uso terapéutico , Mecánica Respiratoria/efectos de los fármacos , Descanso/fisiología , Citrato de Sildenafil , Volumen Sistólico/efectos de los fármacos , Volumen Sistólico/fisiología , Presión Ventricular/efectos de los fármacos , Presión Ventricular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...