RESUMEN
This study discussed comparing result accuracy and time cost under different tally methods using MCNP6 for a novel transmission x-ray tube which was designed for the Auger electron yield with specific material (e.g. iodine). The assessment included photon spectrum, percent depth dose, mass-energy absorption coefficient corresponding to air and water, and figure of merit comparison. The mean energy of in-air phantom was from 41.8 keV (0 mm) to 40.9 keV (100 mm), and the mean energy of in-water phantom was from 41.41 keV (0 mm) to 45.2 keV (100 mm). The specific dose conversion factors based mass-energy absorption coefficient corresponding to different materials was established and the difference was less than 2% for the dose conversion of FMESH comparing to measurement data. FMESH had better figure of merit (FOM) than the F6 tally for the dose parameter assessment, which mean the dose calculation that focused on the superficial region could be assessed with more calculation efficiency by FMESH tally for this novel transmission x-ray tube. The results of this study could help develop treatment planning system (TPS) to quickly obtain the calculated data for phase space data establishment and heterogeneous correction under different physical condition settings.
Asunto(s)
Método de Montecarlo , Fantasmas de Imagen , Fotones , Radiometría , Radiometría/métodos , Rayos X , Humanos , Dosis de Radiación , Agua/química , Simulación por ComputadorRESUMEN
BACKGROUND: The inherent problems in the existence of electron equilibrium and steep dose fall-off pose difficulties for small- and narrow-field dosimetry. OBJECTIVE: To investigate the cutout factors for keloid electron radiotherapy using various dosimetry detectors for small and narrow fields. METHOD: The measurements were performed in a solid water phantom with nine different cutout shapes. Five dosimetry detectors were used in the study: pinpoint 3D ionization chamber, Farmer chamber, semiflex chamber, Classic Markus parallel plate chamber, and EBT3 film. RESULTS: The results demonstrated good agreement between the semiflex and pinpoint chambers. Furthermore, there was no difference between the Farmer and pinpoint chambers for large cutouts. For the EBT3 film, half of the cases had differences greater than 1%, and the maximum discrepancy compared with the reference chamber was greater than 2% for the narrow field. CONCLUSION: The parallel plate, semiflex chamber and EBT3 film are suitable dosimeters that are comparable with pinpoint 3D chambers in small and narrow electron fields. Notably, a semiflex chamber could be an alternative option to a pinpoint 3D chamber for cutout widths≥3âcm. It is very important to perform patient-specific cutout factor calibration with an appropriate dosimeter for keloid radiotherapy.
Asunto(s)
Electrones , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Radiometría/métodos , Radiometría/instrumentación , Humanos , Queloide/radioterapiaRESUMEN
This study uses Monte Carlo simulation and experimental measurements to develop a predictive model for estimating the external dose rate associated with permanent radioactive source implantation in prostate cancer patients. The objective is to estimate the accuracy of the patient's external dose rate measurement. First, I-125 radioactive sources were implanted into Mylar window water phantoms to simulate the permanent implantation of these sources in patients. Water phantom experimental measurement was combined with Monte Carlo simulation to develop predictive equations, whose performance was verified against external clinical data. The model's accuracy in predicting the external dose rate in patients with permanently implanted I-125 radioactive sources was high (R2 = 0.999). A comparative analysis of the experimental measurements and the Monte Carlo simulations revealed that the maximum discrepancy between the measured and calculated values for the water phantom was less than 5.00%. The model is practical for radiation safety assessments, enabling the evaluation of radiation exposure risks to individuals around patients with permanently implanted I-125 radioactive sources.
RESUMEN
PURPOSE: Proton stereotactic radiosurgery (PSRS) has emerged as an innovative proton therapy modality aimed at achieving precise dose delivery with minimal impact on healthy tissues. This study explores the dosimetric outcomes of PSRS in comparison to traditional intensity-modulated proton therapy (IMPT) by focusing on cases with small target volumes. A custom-made aperture system designed for proton therapy, specifically tailored to small target volumes, was developed and implemented for this investigation. METHODS: A prerequisite mechanical validation through an isocentricity test precedes dosimetric assessments, ensuring the seamless integration of mechanical and dosimetry analyses. Five patients were enrolled in the study, including two with choroid melanoma and three with arteriovenous malformations (AVM). Two treatment plans were meticulously executed for each patient, one utilizing a collimated aperture and the other without. Both plans were subjected to robust optimization, maintaining identical beam arrangements and consistent optimization parameters to account for setup errors of 2 mm and range uncertainties of 3.5%. Plan evaluation metrics encompassing the Heterogeneity Index (HI), Paddick Conformity Index (CIPaddick), Gradient Index (GI), and the R50% index to evaluate alterations in low-dose volume distribution. RESULTS: The comparative analysis between PSRS and traditional PBS treatment revealed no significant differences in plan outcomes, with both modalities demonstrating comparable target coverage. However, collimated apertures resulted in discernible improvements in dose conformity, dose fall-off, and reduced low-dose volume. CONCLUSIONS: This study underscores the advantageous impact of the aperture system on proton therapy, particularly in cases involving small target volumes.
Asunto(s)
Órganos en Riesgo , Terapia de Protones , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiocirugia/métodos , Terapia de Protones/métodos , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo/efectos de la radiación , Melanoma/radioterapia , Melanoma/cirugíaRESUMEN
BACKGROUND: Pancreatic adenocarcinoma is often not diagnosed until an advanced stage, and so most patients are not eligible for resection. For patients who are inoperable, definitive radiotherapy is crucial for local disease control. However, the pancreas is located close to other vulnerable gastrointestinal organs, making it challenging to deliver an adequate radiation dose. The surgical insertion of spacers or injection of fluids such as hydrogel before radiotherapy has been proposed, however, no study has discussed which patients are suitable for the procedure. METHODS: In this study, we reviewed 50 consecutive patients who received definitive radiotherapy at our institute to determine how many could have benefitted from hydrodissection to separate the pancreatic tumor from the adjacent gastrointestinal tract. By hypothetically injecting a substance using either computed tomography (CT)-guided or endoscopic methods, we aimed to increase the distance between the pancreatic tumor and surrounding hollow organs, as this would reduce the radiation dose delivered to the organs at risk. RESULTS: An interventional radiologist considered that hydrodissection was feasible in 23 (46%) patients with a CT-guided injection, while a gastroenterologist considered that hydrodissection was feasible in 31 (62%) patients with an endoscopic injection. Overall, we found 14 (28%) discrepancies among the 50 patients reviewed. Except for 1 patient who had no available trajectory with a CT-guided approach but in whom hydrodissection was considered feasible with an endoscopic injection, the other 13 patients had different interpretations of whether direct invasion was present in the CT images. CONCLUSION: Our results suggested that about half of the patients could have benefited from hydrodissection before radiotherapy. This finding could allow for a higher radiation dose and potentially better disease control.
Asunto(s)
Adenocarcinoma , Estudios de Factibilidad , Neoplasias Pancreáticas , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagen , Adenocarcinoma/radioterapia , Adenocarcinoma/diagnóstico por imagen , Masculino , Anciano , Persona de Mediana Edad , Femenino , Anciano de 80 o más Años , Adulto , InyeccionesRESUMEN
PURPOSE: Transmission-target x-ray tubes generate more x-rays than reflection thick-target x-ray tubes. A transmission x-ray tube combined with radiosensitizers has a better radiation enhancement effect. This study investigated the feasibility of using a transmission x-ray tube with radiosensitizers in clinical radiotherapy and its effect on radiation dose enhancement. METHODS: This study used MCNP6.2 to simulate the model of a transmission x-ray tube and Co-60 beam. The radiation enhancement effect of radiosensitizers was examined with iodine-127 (I-127), radioiodinated iododeoxyuridine (IUdR), and gold nanoparticles (GNPs). RESULTS: The study results showed that the dose enhancement factor (DEF) of the transmission x-ray tube with GNPs was 10.27, which was higher than that of I-127 (6.46) and IUdR (3.08). The DEF of the Co-60 beam with GNPs, I-127, and IUdR was 1.23, 1.19, and 1.2, respectively. The Auger electron flux of the transmission x-ray tube with GNPs was 1.19E+05 particles/cm2 . CONCLUSIONS: This study found that a transmission x-ray tube with appropriate radiosensitizers could produce a high rate of Auger electrons to fulfill the radiation enhancement effect, and this procedure has the potential to become a radiotherapy modality.
Asunto(s)
Nanopartículas del Metal , Fármacos Sensibilizantes a Radiaciones , Idoxuridina , Rayos X , Método de Montecarlo , Oro , Nanopartículas del Metal/uso terapéuticoRESUMEN
BACKGROUND: Systemic therapy is the primary treatment for advanced thymic malignancies. However, there is an urgent need to improve clinical outcome. Personalized treatment based on predictive biomarkers is a potential approach to address this requirement. In this study, we aimed to show the correlation between drug sensitivity tests on CTCs-derived organoids and clinical response in patients with thymic malignancies. This approach carries the potential to create personalized cancer avatars and improve treatment outcome for patients. METHODS: We previously reported potential treatment outcome prediction with patient-derived organoids (cancer avatars) in patients with pancreatic ductal adenocarcinoma. To further investigate the feasibility of this approach in advanced thymic malignancies, we conducted a study in which 12 patients were enrolled and 21 liquid biopsies were performed. RESULTS: Cancer avatars were successfully derived in 16 out of 21 samples (success rate 76.2%). We found a sensitivity of 1.0 and specificity of 0.6 for drug sensitivity tests on the cancer avatars, and a two-tailed Fisher's exact test revealed a significant correlation between drug sensitivity tests and clinical responses (p = 0.0275). CONCLUSION: This study supports the potential of circulating tumor cell-derived organoids to inform personalized treatment for advanced thymic malignancies. Further validation of this proof of concept finding is ongoing.
Asunto(s)
Células Neoplásicas Circulantes , Neoplasias Pancreáticas , Neoplasias del Timo , Humanos , Proyectos Piloto , Células Neoplásicas Circulantes/patología , Neoplasias del Timo/patología , Neoplasias Pancreáticas/patología , Organoides/patologíaRESUMEN
This paper discusses the feasibility of a monitoring program for the quality assurance status of activity meters. We sent a questionnaire to clinical nuclear medicine departments of medical institutions, requesting information on their activity meters and quality assurance practices. On-site visits were conducted with exemption-level standard sources (Co-57, Cs-137 and Ba-133) for dose calibrators in nuclear medicine departments including physical inspection, accuracy and reproducibility. A method offering a quick check on the detection efficiency of the space dimension inside the activity meters was also introduced. For dose calibrator quality assurance, the daily checks had the highest implementation. However, annual checks and upon acceptance/after a repair check were reduced to 50% and 44%, respectively. The accuracy results of dose calibrators showed that all models exceeded the ±10% criteria with Co-57 and Cs-137 sources. The reproducibility results showed that some models exceeded the ±5% criteria with Co-57 and Cs-137 sources. The appropriate application of exemption-level standard sources considering the uncertainty that affects the measurement is discussed.
Asunto(s)
Radioisótopos de Cesio , Reproducibilidad de los Resultados , IncertidumbreRESUMEN
PURPOSE: Pediatric diffuse malignant glioma located in the brainstem was officially named "diffuse midline glioma" (DMG) by the World Health Organization in 2016. For this disease, radical surgery is not beneficial, and the only major treatment strategy is radiotherapy. However, the dose limitations to brainstem tissue mean that treatment by radiotherapy can only control and not eradicate the tumors, and there is no effective treatment for recurrence, resulting in short overall survival of 6-12 months. This paper reports our experience with boron neutron capture therapy (BNCT), a new treatment process, and its efficacy in treating children with recurrent DMG. METHODS: From September 2019 to July 2022, we treated 6 children affected by recurrent DMG. With the collaboration of Taipei Veteran General Hospital (TVGH) and National Tsing-Hua University (NTHU), each patient received two sessions of BNCT within 1 month. RESULTS: Among the six patients, three showed partial response and the rest had stable disease after the treatment. The overall survival and recurrence-free survival duration after treatment were 6.39 and 4.35 months, respectively. None of the patients developed severe side effects, and only one patient developed brain necrosis, which was most likely resulted from previous hypofractionated radiotherapy received. CONCLUSION: BNCT elicited sufficient tumor response with low normal tissue toxicity; it may benefit vulnerable pediatric patients with DMG.
Asunto(s)
Terapia por Captura de Neutrón de Boro , Neoplasias Encefálicas , Glioma , Humanos , Niño , Neoplasias Encefálicas/radioterapia , Terapia por Captura de Neutrón de Boro/efectos adversos , Terapia por Captura de Neutrón de Boro/métodos , Glioma/radioterapia , Resultado del Tratamiento , Recurrencia Local de Neoplasia/patologíaRESUMEN
BACKGROUND AND PURPOSE: Hippocampal avoidance whole brain radiotherapy (HA-WBRT) is effective for controlling disease and preserving neuro-cognitive function for brain metastases. However, contouring and planning of HA-WBRT is complex and time-consuming. We designed and evaluated a pipeline using deep learning tools for a fully automated treatment planning workflow to generate HA-WBRT radiotherapy plans. MATERIALS AND METHODS: We retrospectively collected 50 adult patients who received HA-WBRT. Using RTOG- 0933 clinical trial protocol guidelines, all organs-at-risk (OARs) and the clinical target volume (CTV) were contoured by experienced radiation oncologists. A deep-learning segmentation model was designed and trained. Next, we developed a volumetric-modulated arc therapy (VMAT) auto-planning algorithm for 30 Gy in 10 fractions. Automated segmentations were evaluated using the Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance (95 % HD). Auto-plans were evaluated by the percentage of PTV volume that receives 30 Gy (V30Gy), conformity index (CI), and homogeneity index (HI) of planning target volume (PTV) and the minimum dose (D100%) and maximum dose (Dmax) for the hippocampus, Dmax for the lens, eyes, optic nerve, brain stem, and chiasm. RESULTS: We developed a deep-learning segmentation model and an auto-planning script. For the 10 cases in the independent test set, the overall average DSC and 95 % HD of contours were greater than 0.8 and less than 7 mm, respectively. All auto-plans met the RTOG- 0933 criteria. The HA-WBRT plan automatically created time was about 10 min. CONCLUSIONS: An artificial intelligence (AI)-assisted pipeline using deep learning tools can rapidly and accurately generate clinically acceptable HA-WBRT plans with minimal manual intervention and increase efficiency of this treatment for brain metastases.
Asunto(s)
Neoplasias Encefálicas , Radioterapia de Intensidad Modulada , Adulto , Humanos , Inteligencia Artificial , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Hipocampo , Tratamientos Conservadores del Órgano , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios RetrospectivosRESUMEN
This study was to determine the significance of factors considered for the measurement accuracy of personal dosimeter in dosimetry services such as dosimetry service, irradiation category, years of use and readout frequency. The investigation included management information questionnaire, on-site visit and blind test. The blind test with random selected personal badge was used in inter-comparison of eight dosimetry services, and the test results followed ANSI/HPS N13.11 criteria. This study also analyzed the measurement deviations if they felt in the criteria of ICRP 75 or not. One-way ANOVA tests were used to analyze the significant difference of the measurement deviations in different dosimetry services, irradiation categories, and years of use. Simple linear-regression test was performed for the significance of the prediction model between measurement deviations and readout frequencies. All visited dosimetry services followed the proper statue of basic management and passed the performance check of the tolerance level. The average deviations corresponding to category I, category II deep dose, and category II shallow dose were 6.08%, 9.49%, and 10.41% respectively. There had significant differences of measurement deviation in different dosimetry services (p < 0.0001) and irradiation categories (p = 0.016) but no significant difference in years of use (p = 0.498). There was no significance in the linear-regression model between measurement deviation and badge readout frequencies. Based on the regular calibration of the personal dosimeter, the deviation of the measured value is mainly affected by different dosimetry services and irradiation categories; and there shows no significant influence by years of use and readout frequency.
Asunto(s)
Dosímetros de Radiación , Radiometría , Calibración , Análisis de VarianzaRESUMEN
(1) Background: The purpose of this study was to evaluate the radiation awareness level of the public in Taiwan. (2) Methods: This study designed an online survey form to investigate the radiation awareness level with six topics: basic knowledge of radiation, environmental radiation, medical radiation, radiation protection, and university/corporate social responsibility. The score of respondents were converted into knowledge and responsibility indexes for the quantitative evaluation. Logistic regression was used to assess the correlation between the knowledge index and individual factors. Paired t-test was used to assess the significant difference in knowledge index between pre-training and post-training. (3) Results: The knowledge index of each job category reflected the proportion of radiation awareness of the job. The logistic regression result indicated that radiation-related people could get higher knowledge index. The paired t-test indicated that the knowledge index before and after class had significant differences in all question topics. (4) Conclusions: The public's awareness of medical radiation was the topic that needed to be strengthened the most-the responses with high knowledge index significantly correlated with their experience in radiation education training or radiation-related jobs. It significantly increased the knowledge index of radiation if the public received radiation education training.
Asunto(s)
Conocimientos, Actitudes y Práctica en Salud , Protección Radiológica , Humanos , Taiwán , Encuestas y Cuestionarios , Modelos Logísticos , ConcienciaciónRESUMEN
Background: This study aims to establish and validate a predictive model based on radiomics features, clinical features, and radiation therapy (RT) dosimetric parameters for overall survival (OS) in hepatocellular carcinoma (HCC) patients treated with RT for portal vein tumor thrombosis (PVTT). Methods: We retrospectively reviewed 131 patients. Patients were randomly divided into the training (n = 105) and validation (n = 26) cohorts. The clinical target volume was contoured on pre-RT computed tomography images and 48 textural features were extracted. The least absolute shrinkage and selection operator regression was used to determine the radiomics score (rad-score). A nomogram based on rad-score, clinical features, and dosimetric parameters was developed using the results of multivariate regression analysis. The predictive nomogram was evaluated using Harrell's concordance index (C-index), area under the curve (AUC), and calibration curve. Results: Two radiomics features were extracted to calculate the rad-score for the prediction of OS. The radiomics-based nomogram had better performance than the clinical nomogram for the prediction of OS, with a C-index of 0.73 (95% CI, 0.67-0.79) and an AUC of 0.71 (95% CI, 0.62-0.79). The predictive accuracy was assessed by a calibration curve. Conclusion: The radiomics-based predictive model significantly improved OS prediction in HCC patients treated with RT for PVTT.
RESUMEN
This study evaluated dose differences in normal organs at risk, such as the lungs, heart, left anterior descending artery (LAD), right coronary artery, left ventricle, and right breast under personalized breast holder (PERSBRA), when using intensity-modulated radiation therapy (IMRT). This study evaluated the radiation protection offered by PERSBRA in left breast cancer radiation therapy. Here, we retrospectively collected data from 24 patients with left breast cancer who underwent breast-conserving surgery as well as IMRT radiotherapy. We compared the dose differences in target coverage and organs at risk with and without PERSBRA. For target coverage, tumor prescribed dose 95% coverage, conformity index, and homogeneity index were evaluated. For organs at risk, we compared the mean heart dose, mean left ventricle dose, LAD maximum and mean dose, mean left lung receiving 20 Gy, 10 Gy, and 5 Gy of left lung volume, maximum and mean coronary artery of the right, maximum of right breast, and mean dose. Good target coverage was achieved with and without PERSBRA. When PERSBRA was used with IMRT, the mean dose of the heart decreased by 42%, the maximum dose of LAD decreased by 26.4%, and the mean dose of LAD decreased by 47.0%. The mean dose of the left ventricle decreased by 54.1%, the volume (V20) of the left lung that received 20 Gy decreased by 22.8%, the volume (V10) of the left lung that received 10 Gy decreased by 19.8%, the volume (V5) of the left lung that received 5 Gy decreased by 15.7%, and the mean dose of the left lung decreased by 23.3%. Using PERSBRA with IMRT greatly decreases the dose to organs at risk (left lung, heart, left ventricle, and LAD). This study found that PERSBRA with IMRT can achieve results similar to deep inspiration breath-hold radiotherapy (DIBH) in terms of reducing the heart radiation dose and the risk of developing heart disease in patients with left breast cancer who cannot undergo DIBH.
RESUMEN
BACKGROUND: Neoadjuvant chemoradiation therapy (NCRT) followed by surgery is the standard treatment for locally advanced rectal cancer (LARC); approximately 80% of patients do not achieve complete response. Identifying prognostic factors predictive of survival in these patients to guide further management is needed. The intratumoural lymphocytic response (ILR), peritumoural lymphocytic reaction (PLR), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PtLR) are correlated with the tumour microenvironment and cancer-related systemic inflammation. This study aimed to explore the ability of the ILR, PLR, NLR, and PtLR to predict survival in LARC patients without a complete response to NCRT. METHODS: Sixty-nine patients who underwent NCRT and surgery were retrospectively reviewed. The ILR and PLR were assessed in surgical specimens, and the NLR and PtLR were calculated using pre- and post-NCRT blood count data. The Kaplan-Meier method and Cox regression analyses were performed for survival analysis. RESULTS: A high PLR and high post-NCRT NLR and PtLR were significantly associated with better prognosis. Lymphovascular invasion (LVI), post-NCRT neutrophil count, and lymphocyte count were significant predictors of overall survival. LVI and the PLR were independent predictors of disease-free survival. CONCLUSIONS: NCRT-induced local and systemic immune responses are favourable prognostic predictors in LARC patients without complete response to NCRT.
RESUMEN
PURPOSE: Breast immobilization with personalized breast holder (PERSBRA) is a promising approach for normal organ protection during whole breast radiotherapy. The aim of this study is to evaluate the skin surface dose for breast radiotherapy with PERSBRA using different radiotherapy techniques. MATERIALS AND METHODS: We designed PERSBRA with three different mesh sizes (large, fine and solid) and applied them on an anthropomorphic(Rando) phantom. Treatment planning was generated using hybrid, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques to deliver a prescribed dose of 5000 cGy in 25 fractions accordingly. Dose measurement with EBT3 film and TLD were taken on Rando phantom without PERSBRA, large mesh, fine mesh and solid PERSBRA for (a) tumor doses, (b) surface doses for medial field and lateral field irradiation undergoing hybrid, IMRT, VMAT techniques. RESULTS: The tumor dose deviation was less than five percent between the measured doses of the EBT3 film and the TLD among the different techniques. The application of a PERSBRA was associated with a higher dose of the skin surface. A large mesh size of PERSBRA was associated with a lower surface dose. The findings were consistent among hybrid, IMRT, or VMAT techniques. CONCLUSIONS: Breast immobilization with PERSBRA can reduce heart toxicity but leads to a build-up of skin surface doses, which can be improved with a larger mesh design for common radiotherapy techniques.
RESUMEN
This study combined the use of radiation dosimeteric measurements and a custom-made anthropomorphic phantom in order to evaluate the accuracy of therapeutic dose calculations at the nasopharyngeal air-tissue interface. The doses at the nasopharyngeal air-tissue interface obtained utilizing the Pinnacle and TomoTherapy TPS, which are based on collapsed cone convolution superposition (CCCS) algorithms, were evaluated and measured under single 10 × 10 cm2, 2 × 2 cm2, two parallel opposed 2 × 2 cm2 and clinical fields for early stage of nasopharyngeal carcinoma by using EBT3, GR-200F, and TLD 100. At the air-tissue interface under a 10 × 10 cm2 field, the TPS dose calculation values were in good agreement with the dosimeter measurement with all differences within 3.5%. When measured the single field 2 × 2 cm2, the differences between the average dose were measured at the distal interface for EBT3, GR-200F, and TLD-100 and the calculation values were -15.8%, -16.4%, and -4.9%, respectively. When using the clinical techniques such as IMRT, VMAT, and tomotherapy, the measurement results at the interface for all three techniques did not imply under dose. Small-field sizes will lead to dose overestimation at the nasopharyngeal air-tissue interface due to electronic disequilibrium when using CCCS algorithms. However, under clinical applications of multiangle irradiation, the dose errors caused by this effect were not significant.
Asunto(s)
Neoplasias Nasofaríngeas , Planificación de la Radioterapia Asistida por Computador , Algoritmos , Humanos , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Nasofaringe , Fantasmas de Imagen , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodosRESUMEN
BACKGROUND: Protecting cardiac function in patients with advanced left-breast cancer receiving radiation therapy (RT) with regional nodal irradiation (RNI) is an important issue. Modern RT techniques can limit cardiac exposure. The aim of this study was to explore the association be-tween cardiac dose and cardiac function. METHODS: Between 2017 and 2020, we retrospectively reviewed left-breast cancer patients who received adjuvant RT, including RNI with either volumetric-modulated arc therapy (VMAT) or helical tomotherapy (HT). Left ventricular ejection fraction (LVEF) was assessed by echocardiography before RT and 1 year after RT to detect any early deterioration in cardiac systolic function. RESULTS: A total of 30 eligible patients were enrolled. The median follow-up time from the initiation of RT was 3.9 years (range 0.6-5 years). Seventeen patients received VMAT, and the other 13 patients received HT. The median RT dose was 55 Gray (Gy), and the mean heart dose was 3.73 Gy (range 1.95-9.36 Gy). The median LVEF before and after RT was 68% and 68.5%, respectively. No obvious deterioration was found. There was no association between cardiac dose (mean heart dose, V5-V30) and LVEF (change in values or post-RT). CONCLUSIONS: For left-breast cancer patients undergoing RT with RNI, VMAT, or HT can be used to limit cardiac exposure. Cardiac function as evaluated by LVEF revealed no obvious deterioration after RT in our patients, and no association was found between cardiac dose and LVEF in those treated with either VMAT or HT in early cardiac surveillance.
RESUMEN
To develop a method of estimating surface dose in whole breast irradiation, we used an anthropomorphic phantom with accessories for the simulation of different breast sizes. The surface points, which are measured by TLDs, are set along with two main directions, superior-inferior and medial-lateral. The incident angle between the photon beam and the surface and the doses at 1 cm beneath the surface at every point are assessed by a computerized treatment planning system (cTPS). With the prescription dose of 200 cGy, the average surface doses under tangential irradiation are 97.73 (±14.96) cGy, 99.90 (±10.73) cGy, and 105.26 (±9.21) cGy for large, medium, and small breast volumes, respectively. The surface dose increased in the model of small breast volume without significance (p = 0.39). The linear analysis between surface dose and the incident angle is y = 0.5258x + 69.648, R2 = 0.7131 (x: incident angle and y: surface dose). We develop the percentage of skin surface dose with reference to a depth of 1 cm (PSDR1cm) to normalize the inhomogeneous dose. The relationship between incident angle and PSDR1cm is y = 0.1894x + 36.021, R2 = 0.6536 (x: incident angle and y: PSDR1cm) by linear analysis. In conclusion, the surface dose in whole breast irradiation could be estimated from this linear relationship between PSDR1cm and incident angle in daily clinical practice by cTPS. Further in vivo data should be studied to verify this formula.
RESUMEN
INTRODUCTION: Pancreatic ductal adenocarcinoma (PDAC) is highly aggressive and has poor prognosis. There are few biomarkers to inform treatment decisions, and collecting tumour samples for testing is challenging. METHODS: Circulating tumour cells (CTCs) from patients with PDAC liquid biopsies were expanded ex vivo to form CTC-derived organoid cultures, using a laboratory-developed biomimetic cell culture system. CTC-derived organoids were tested for sensitivity to a PDAC panel of nine drugs, with tests conducted in triplicate, and a weighted cytotoxicity score (CTS) was calculated from the results. Clinical response to treatment in patients was evaluated using Response Evaluation Criteria in Solid Tumours (RECIST) version 1.1 criteria at the time of blood sampling and 3 months later. The correlation between CTS and clinical response was then assessed. RESULTS: A total of 41 liquid biopsies (87.8% from patients with Stage 4 disease) were collected from 31 patients. The CTC-derived organoid expansion was achieved in 3 weeks, with 87.8% culture efficiency. CTC-derived organoid cultures were positive for EpCAM staining and negative for CD45 staining in the surface marker analysis. All patients had received a median of two lines of treatment prior to enrolment and prospective utility analysis indicated significant correlation of CTS with clinical treatment response. Two representative case studies are also presented to illustrate the relevant clinical contexts. CONCLUSIONS: CTCs were expanded from patients with PDAC liquid biopsies with a high success rate. Drug sensitivity profiles from CTC-derived organoid cultures correlated meaningfully with treatment response. Further studies are warranted to validate the predictive potential for this approach.