Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Sleep Med ; 2024 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-39436388

RESUMEN

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is associated with cognitive impairment; however, the underlying mechanisms remain incompletely understood. OSA is characterized by periods of interrupted ventilation ("ventilatory burden (VB)"), leading to hypoxemia ("hypoxic burden (HB)") and/or arousal ("arousal burden (AB)") from sleep. While hypoxemia is considered a key mechanism underlying white matter injury, its measurement has been limited. In our primary analysis, we assessed the association of HB, a quantitative measure of hypoxemia, with white matter hyperintensity volume (WMHv), a marker of small vessel disease, and compared with that of VB and AB (quantitative measures of ventilatory deficit and arousals). METHODS: Data from participants in the Multi-Ethnic Study of Atherosclerosis with full polysomnograms (PSG) and brain MRI were analyzed. HB was defined as the total area under the oxygen desaturation curve per hour of sleep, while VB was defined as the event-specific area under the ventilation signal and AB was defined as the normalized cumulative duration of all arousals. The primary outcome was WMHv, with other MRI measures considered secondary outcomes. RESULTS: The analysis included PSGs from 587 participants (age: 65.5±8.2 years). In the fully adjusted model, each 1 standard deviation (SD) increase in HB was associated with a 0.09 SD increase in WMHv (p=0.023), after adjusting for demographics, study site, and comorbidities. In contrast, VB, AB, and conventional OSA measures were not associated with outcomes. CONCLUSIONS: Hypoxic burden was associated with white matter hyperintensity volume in a racially/ethnically diverse cohort of older individuals with a high prevalence of OSA.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39361293

RESUMEN

Importance: Mouth breathing is associated with increased airway resistance, pharyngeal collapsibility, and obstructive sleep apnea (OSA) severity. The common belief is that closing the mouth can mitigate the negative effects of mouth breathing during sleep. However, mouth breathing may serve as an essential route to bypassing obstruction along the nasal route (eg, the velopharynx). Objective: To investigate the role of mouth breathing as an essential route in some patients with OSA and its association with upper airway anatomical factors. Design, Setting, and Participants: This nonrandomized clinical trial included participants diagnosed with OSA who underwent drug-induced sleep endoscopy. Patients were stratified into 3 quantiles based on oral-breathing level (quantile 1: oral airflow < 0.05 L/min; quantile 2: oral airflow 0.05-2.2 L/min; quantile 3: oral airflow > 2.2 L/min). Interventions: Closing the mouth during sleep during alternating breaths by applying pressure to the mentum until teeth are in occlusion. Main Outcomes and Measures: The primary outcome was total inspiratory flow defined as the change in airflow in the transition from mouth relaxed to mouth closed, analyzed overall and by 3 oral-breathing quantiles. The association of velopharyngeal obstruction on the change in total inspiratory airflow was also investigated. Results: Of 66 enrolled patients with OSA, 12 were excluded due to insufficient baseline airflow. The analytic cohort consisted of 54 patients (39 [72%] male; median [IQR] age, 55 [46-64] years; apnea-hypopnea index, 26.9 [17.6-39.9] events/h; and body mass index calculated as weight in kilograms divided by height in meters squared, 28.9 [27.1-31.6]). Mouth closure increased total inspiratory flow by 27.8 percentage points overall (ß, 1.0 [95% CI, 0.4-1.9] L/min). However, outcomes varied based on the degree of baseline oral breathing. No association was found for 10 patients with near-zero mouth breathing (0.9 [95% CI, -0.2 to 2.1] L/min). Airflow improved with mouth closure in 32 patients with moderate levels of mouth breathing (2.0 [95% CI, 1.3-2.7] L/min), whereas it worsened in patients with high levels of mouth breathing (-1.9 [95% CI, -3.1 to -0.6] L/min). Velopharyngeal obstruction was associated with increased mouth breathing (0.6 [95% CI, 0.1-3.0] L/min) and reduced airflow with mouth closure (-1.9 [95% CI, -3.1 to -0.7] L/min). Conclusion and Relevance: Although mouth closure increased inspiratory airflow in the overall cohort of this nonrandomized clinical trial, the outcomes were heterogeneous. In patients who breathe primarily through their mouth during sleep and have velopharyngeal obstruction, airflow worsens with mouth closure. Hence, personalized approaches to treating mouth breathing should be considered. Trial Registration: ClinicalTrials.gov Identifier: NCT06547658.

3.
Hypertension ; 81(5): 1106-1114, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38506074

RESUMEN

BACKGROUND: Obstructive sleep apnea is associated with increased blood pressure (BP). Obstructive sleep apnea treatment reduces BP with substantial variability, not explained by the apnea-hypopnea index, partly due to inadequate characterization of obstructive sleep apnea's physiological consequences, such as oxygen desaturation, cardiac autonomic response, and suboptimal treatment efficacy. We sought to examine whether a high baseline heart rate response (ΔHR), a marker of high cardiovascular risk in obstructive sleep apnea, predicts a larger reduction in post-treatment systolic BP (SBP). Furthermore, we aimed to assess the extent to which a reduction in SBP is explained by a treatment-related reduction in hypoxic burden (HB). METHODS: ΔHR and HB were measured from pretreatment and posttreatment polygraphy, followed by a 24-hour BP assessment in 168 participants treated with continuous positive airway pressure or nocturnal supplemental oxygen from the HeartBEAT study (Heart Biomarker Evaluation in Apnea Treatment). Multiple linear regression models assessed whether high versus mid (reference) ΔHR predicted a larger reduction in SBP (primary outcome) and whether there was an association between treatment-related reductions in SBP and HB. RESULTS: A high versus mid ΔHR predicted improvement in SBP (adjusted estimate, 5.8 [95% CI, 1.0-10.5] mm Hg). Independently, a greater treatment-related reduction in HB was significantly associated with larger reductions in SBP (4.2 [95% CI, 0.9-7.5] mm Hg per 2 SD treatment-related reduction in HB). Participants with substantial versus minimal treatment-related reductions in HB had a 6.5 (95% CI, 2.5-10.4) mm Hg drop in SBP. CONCLUSIONS: A high ΔHR predicted a more favorable BP response to therapy. Furthermore, the magnitude of the reduction in BP was partly explained by a greater reduction in HB.


Asunto(s)
Hipertensión , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Humanos , Presión Sanguínea/fisiología , Frecuencia Cardíaca , Hipoxia , Presión de las Vías Aéreas Positiva Contínua , Oxígeno
4.
Ann Am Thorac Soc ; 21(1): 114-121, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37879037

RESUMEN

Rationale: The physiological factors modulating the severity of snoring have not been adequately described. Airway collapse or obstruction is generally the leading determinant of snore sound generation; however, we suspect that ventilatory drive is of equal importance. Objective: To determine the relationship between airway obstruction and ventilatory drive on snore loudness. Methods: In 40 patients with suspected or diagnosed obstructive sleep apnea (1-98 events/hr), airflow was recorded via a pneumotachometer attached to an oronasal mask, ventilatory drive was recorded using calibrated intraesophageal diaphragm electromyography, and snore loudness was recorded using a calibrated microphone attached over the trachea. "Obstruction" was taken as the ratio of ventilation to ventilatory drive and termed flow:drive, i.e., actual ventilation as a percentage of intended ventilation. Lower values reflect increased flow resistance. Using 165,063 breaths, mixed model analysis (quadratic regression) quantified snore loudness as a function of obstruction, ventilatory drive, and the presence of extreme obstruction (i.e., apneic occlusion). Results: In the presence of obstruction (flow:drive = 50%, i.e., doubled resistance), snore loudness increased markedly with increased drive (+3.4 [95% confidence interval, 3.3-3.5] dB per standard deviation [SD] change in ventilatory drive). However, the effect of drive was profoundly attenuated without obstruction (at flow:drive = 100%: +0.23 [0.08-0.39] dB per SD change in drive). Similarly, snore loudness increased with increasing obstruction exclusively in the presence of increased drive (at drive = 200% of eupnea: +2.1 [2.0-2.2] dB per SD change in obstruction; at eupneic drive: +0.14 [-0.08 to 0.28] dB per SD change). Further, snore loudness decreased substantially with extreme obstruction, defined as flow:drive <20% (-9.9 [-3.3 to -6.6] dB vs. unobstructed eupneic breathing). Conclusions: This study highlights that ventilatory drive, and not simply pharyngeal obstruction, modulates snore loudness. This new framework for characterizing the severity of snoring helps better understand the physiology of snoring and is important for the development of technologies that use snore sounds to characterize sleep-disordered breathing.


Asunto(s)
Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Humanos , Ronquido/diagnóstico , Polisomnografía/métodos , Sonido
5.
Eur Respir J ; 62(6)2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37734857

RESUMEN

BACKGROUND: Hypoxic burden (HB) has emerged as a strong predictor of cardiovascular risk in obstructive sleep apnoea (OSA). We aimed to assess the potential of HB to predict the cardiovascular benefit of treating OSA with continuous positive airway pressure (CPAP). METHODS: This was a post hoc analysis of the ISAACC trial (ClinicalTrials.gov: NCT01335087) including non-sleepy patients with acute coronary syndrome (ACS) diagnosed with OSA (apnoea-hypopnoea index ≥15 events·h-1) by respiratory polygraphy. Patients were randomised to CPAP or usual care and followed for a minimum of 1 year. HB was calculated as the total area under all automatically identified desaturations divided by total sleep time. Patients were categorised as having high or low baseline HB according to the median value (73.1%min·h-1). Multivariable Cox regression models were used to assess whether the effect of CPAP on the incidence of cardiovascular outcomes was dependent on the baseline HB level. RESULTS: The population (362 patients assigned to CPAP and 365 patients assigned to usual care) was middle-aged (mean age 59.7 years), overweight/obese and mostly male (84.5%). A significant interaction was found between the treatment arm and the HB categories. In the high HB group, CPAP treatment was associated with a significant reduction in the incidence of cardiovascular events (HR 0.57, 95% CI 0.34-0.96). In the low HB group, CPAP-treated patients exhibited a trend toward a higher risk of cardiovascular outcomes than those receiving usual care (HR 1.33, 95% CI 0.79-2.25). The differential effect of the treatment depending on the baseline HB level followed a dose-response relationship. CONCLUSION: In non-sleepy ACS patients with OSA, high HB levels were associated with a long-term protective effect of CPAP on cardiovascular prognosis.


Asunto(s)
Síndrome Coronario Agudo , Apnea Obstructiva del Sueño , Persona de Mediana Edad , Humanos , Masculino , Femenino , Presión de las Vías Aéreas Positiva Contínua , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/terapia , Modelos de Riesgos Proporcionales , Síndrome Coronario Agudo/complicaciones , Hipoxia/complicaciones
6.
Ann Am Thorac Soc ; 20(11): 1633-1641, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37531573

RESUMEN

Rationale: Recent studies have shown that sleep apnea-specific intermittent hypoxemia quantified by the hypoxic burden (HB) predicted cardiovascular disease (CVD)-related mortality in community-based and clinical cohorts. Calculation of HB is based on manual scoring of hypopneas and apneas, which is time-consuming and prone to interscorer variability. Objective: To validate a novel method to quantify the HB that is based on automatically scored desaturations. Methods: The sample included 5,655 middle-aged or older adults from the Sleep Heart Health Study (52.8% women; age, 63.2 ± 11.3 yr). The original HB method was based on a subject-specific search window obtained from an ensemble average of oxygen saturation signals (as measured by pulse oximetry) and synchronized with respect to the termination of scored respiratory events. In this study, however, the search window was obtained from ensemble average of oxygen saturation signals that synchronized with respect to the minimum of all automatically identified desaturations (⩾2% and other thresholds, including 3% and 4%, in sensitivity analyses). The time interval between the two maxima around the minimum saturation was defined as the search window. The oximetry-derived HB (HBOxi) was defined as the total area under all desaturation curves (restricted by the search window) divided by the total sleep time. Logistic and Cox regression models assessed the adjusted odds ratio (aOR)/hazard ratio of excessive daytime sleepiness (EDS), hypertension (HTN), and CVD mortality per 1-standard deviation increase in HBOxi after adjusting for several covariates and confounders. Results: The Spearman's rank correlation between HB (median [interquartile range], 34.4 [18.4-59.8] % min/h) and HBOxi (median [interquartile range], 34.5 [21.6-53.8] % min/h) was 0.81 (P < 0.001). Similar to HB, HBOxi was significantly associated with EDS (aOR [95% confidence interval (CI)], 1.17 [1.09-1.26] per standard deviation), HTN (aOR [95% CI], 1.13 [1.05-1.21]), and CVD mortality (adjusted hazard ratio [95% CI], 1.15 [1.01-1.30]) in fully adjusted models. Conclusions: The HBOxi was highly correlated with the HB based on manually scored apneas and hypopneas and was associated with EDS, HTN, and CVD mortality with similar effect sizes as previously reported. This method could be incorporated into wearable technology that accurately records oxygen saturation signals.


Asunto(s)
Enfermedades Cardiovasculares , Hipertensión , Síndromes de la Apnea del Sueño , Persona de Mediana Edad , Humanos , Femenino , Anciano , Masculino , Síndromes de la Apnea del Sueño/complicaciones , Hipertensión/epidemiología , Hipertensión/complicaciones , Enfermedades Cardiovasculares/epidemiología , Hipoxia/complicaciones , Evaluación de Resultado en la Atención de Salud
7.
Am J Respir Crit Care Med ; 208(7): 802-813, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37418748

RESUMEN

Rationale: Obstructive sleep apnea is characterized by frequent reductions in ventilation, leading to oxygen desaturations and/or arousals. Objectives: In this study, association of hypoxic burden with incident cardiovascular disease (CVD) was examined and compared with that of "ventilatory burden" and "arousal burden." Finally, we assessed the extent to which the ventilatory burden, visceral obesity, and lung function explain variations in hypoxic burden. Methods: Hypoxic, ventilatory, and arousal burdens were measured from baseline polysomnograms in the Multi-Ethnic Study of Atherosclerosis (MESA) and the Osteoporotic Fractures in Men (MrOS) studies. Ventilatory burden was defined as event-specific area under ventilation signal (mean normalized, area under the mean), and arousal burden was defined as the normalized cumulative duration of all arousals. The adjusted hazard ratios for incident CVD and mortality were calculated. Exploratory analyses quantified contributions to hypoxic burden of ventilatory burden, baseline oxygen saturation as measured by pulse oximetry, visceral obesity, and spirometry parameters. Measurements and Main Results: Hypoxic and ventilatory burdens were significantly associated with incident CVD (adjusted hazard ratio [95% confidence interval] per 1 SD increase in hypoxic burden: MESA, 1.45 [1.14, 1.84]; MrOS, 1.13 [1.02, 1.26]; ventilatory burden: MESA, 1.38 [1.11, 1.72]; MrOS, 1.12 [1.01, 1.25]), whereas arousal burden was not. Similar associations with mortality were also observed. Finally, 78% of variation in hypoxic burden was explained by ventilatory burden, whereas other factors explained only <2% of variation. Conclusions: Hypoxic and ventilatory burden predicted CVD morbidity and mortality in two population-based studies. Hypoxic burden is minimally affected by measures of adiposity and captures the risk attributable to ventilatory burden of obstructive sleep apnea rather than a tendency to desaturate.


Asunto(s)
Aterosclerosis , Enfermedades Cardiovasculares , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Masculino , Humanos , Obesidad Abdominal , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/epidemiología , Polisomnografía , Enfermedades Cardiovasculares/epidemiología , Hipoxia , Sueño/fisiología
8.
Adv Exp Med Biol ; 1384: 79-103, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36217080

RESUMEN

The SERVE-HF (Treatment of Predominant Central Sleep Apnea by Adaptive Servo Ventilation in Patients with Heart Failure) multicenter trial found a small but significant increase in all-cause and cardiovascular mortality in patients assigned to adaptive servo-ventilation (ASV) versus guideline-based medical treatment. To better understand the physiological underpinnings of this clinical outcome, we employ an integrative computer model to simulate congestive heart failure with Cheyne-Stokes respiration (CHF-CSR) in subjects with a broad spectrum of underlying pathogenetic mechanisms, as well as to determine the in silico changes in cardiopulmonary and autonomic physiology resulting from ASV. Our simulation results demonstrate that while the elimination of CSR through ASV can partially restore cardiorespiratory and autonomic physiology toward normality in the vast majority of CHF phenotypes, the degree of restoration can be highly variable, depending on the combination of CHF mechanisms in play. The group with the lowest left ventricular ejection fraction (LVEF) appears to be most vulnerable to the potentially adverse effects of ASV, but the level of pulmonary capillary wedge pressure (PCWP) plays an important role in determining the nature of these effects.


Asunto(s)
Insuficiencia Cardíaca , Apnea Central del Sueño , Respiración de Cheyne-Stokes/terapia , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Humanos , Respiración Artificial/efectos adversos , Apnea Central del Sueño/complicaciones , Apnea Central del Sueño/terapia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2792-2795, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33018586

RESUMEN

Plant gain quantifies the extent and rapidity with which arterial blood gases change following hypopneic or hyperpneic events. High plant gain, acting in concert with a highly collapsible upper airway and low arousal threshold, may contribute significantly towards increasing the severity of obstructive sleep apnea (OSA), even when controller gain is low. Elevated plant gain may be a manifestation of abnormal gas exchange resulting from ventilation-perfusion mismatch in the lungs. Using a mathematical model, we explore in this paper how ventilation-perfusion mismatch can affect plant gain, as well as the severity of OSA.


Asunto(s)
Apnea Obstructiva del Sueño , Nivel de Alerta , Humanos , Pulmón , Perfusión , Respiración , Apnea Obstructiva del Sueño/terapia
10.
Environ Monit Assess ; 139(1-3): 205-15, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17574544

RESUMEN

Pollution loads discharged from upstream development or human activities significantly degrade the water quality of a reservoir. The design of an appropriate water quality sampling network is therefore important for detecting potential pollution events and monitoring pollution trends. However, under a limited budgetary constraint, how to site an appropriate number of sampling stations is a challenging task. A previous study proposed a method applying the simulated annealing algorithm to design the sampling network based on three cost factors including the number of reaches, bank length, and subcatchment area. However, these factors are not directly related to the distribution of possible pollution. Thus, this study modified the method by considering three additional factors, i.e. total phosphorus, nitrogen, and sediment loads. The larger the possible load, the higher the probability of a pollution event may occur. The study area was the Derchi reservoir catchment in Taiwan. Pollution loads were derived from the AGNPS model with rainfall intensity estimated using the Thiessen method. Analyses for a network with various numbers of sampling sites were implemented. The results obtained based on varied cost factors were compared and discussed. With the three additional factors, the chosen sampling network is expected to properly detect pollution events and monitor pollution distribution and temporal trends.


Asunto(s)
Contaminantes del Agua/análisis , Abastecimiento de Agua/normas , Algoritmos , Modelos Teóricos , Lluvia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...