Phys Med Biol ; 69(8)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38484392

RESUMEN

Objective.Monolithic crystal detectors are increasingly being applied in positron emission tomography (PET) devices owing to their excellent depth-of-interaction (DOI) resolution capabilities and high detection efficiency. In this study, we constructed and evaluated a dual-ended readout monolithic crystal detector based on a multiplexing method.Approach.We employed two 12 × 12 silicon photomultiplier (SiPM) arrays for readout, and the signals from the 12 × 12 array were merged into 12 X and 12 Y channels using channel multiplexing. In 2D reconstruction, three methods based on the centre of gravity (COG) were compared, and the concept of thresholds was introduced. Furthermore, a light convolutional neural network (CNN) was employed for testing. To enhance depth localization resolution, we proposed a method by utilizing the mutual information from both ends of the SiPMs. The source width and collimation effect were simulated using GEANT4, and the intrinsic spatial resolution was separated from the measured values.Main results.At an operational voltage of 29 V for the SiPM, an energy resolution of approximately 12.5 % was achieved. By subtracting a 0.8 % threshold from the total energy in every channel, a 2D spatial resolution of approximately 0.90 mm full width at half maximum (FWHM) can be obtained. Furthermore, a higher level of resolution, approximately 0.80 mm FWHM, was achieved using a CNN, with some alleviation of edge effects. With the proposed DOI method, a significant 1.36 mm FWHM average DOI resolution can be achieved. Additionally, it was found that polishing and black coating on the crystal surface yielded smaller edge effects compared to a rough surface with a black coating.Significance.The introduction of a threshold in COG method and a dual-ended readout scheme can lead to excellent spatial resolution for monolithic crystal detectors, which can help to develop PET systems with both high sensitivity and high spatial resolution.


Asunto(s)
Redes Neurales de la Computación , Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Fotones , Gravitación
2.
Radiat Prot Dosimetry ; 198(20): 1611-1616, 2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36214508

RESUMEN

Ionization chamber is considered as the golden standard for the dosemeter. This work fabricated one graphite-walled and two polymethyl methacrylate (PMMA)-walled ionization chambers, tested respectively and compared their characteristic parameters. The performance of graphite-walled chamber was similar to that of the PMMA-walled chamber. The relative energy response of ionization chambers was lower than 4% from 50 keV to 50 MeV based on the FLUKA code simulation results. The experimental data showed that the ionization chambers performed well in linearity and repeatability. Assuming the chambers sensitive volume and HV bias was constant, the measured maximum saturation absorbed dose of ionization chambers changed with the diameter variation of chambers anode based on the comparison results of two PMMA-walled ionization chambers.


Asunto(s)
Rayos gamma , Polimetil Metacrilato
3.
Rev Sci Instrum ; 92(1): 013106, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33514237

RESUMEN

A 50 × 50 × 10 mm3 monolithic gadolinium aluminum gallium garnet (Gd3Al2Ga3O12; GAGG):Ce crystal coupled to a 8 × 8 silicon photomultiplier (SiPM) array was developed; it showed very good system uniformity and a high energy resolution of 7.4% at 662 keV. By using a convolutional neural network-based positioning algorithm and a fan-beam calibration method, the detector achieved a position resolution of ∼1.4 mm and a depth of interaction resolution of ∼2 mm. Based on this high-performance monolithic detector, we developed a coded aperture gamma camera. A 1-mCi Cs-137 source centered at a 2-m distance from the mask could be reconstructed with a signal-to-noise ratio of 6.5 in 1 s. Furthermore, the imaging ability of a low-energy Am-241 source and a low-activity Cs-137 source when the background-to-signal ratio was approximately 1:1 and a double low-activity source (Cs-137 and Na-22) was demonstrated. It is shown that the monolithic-crystal-based coded aperture gamma camera can achieve high performance and has a large potential for further improvement.

4.
Appl Radiat Isot ; 82: 293-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24135636

RESUMEN

A depth discrimination method is devised based on a multirow linear array detector for push-broom Compton scatter imaging. Two or more rows of detector modules are placed at different positions towards a sample. An improved parallel-hole collimator is fixed in front of the modules to restrict their fields of view. The depth information could be indicated by comparing the signal differences. In addition, an available detector and several related simulations using GEANT4 are given to support the method well.