Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Mol Pharm ; 19(10): 3511-3520, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-35044182

RESUMEN

Hypoxic areas are present in the majority of solid tumors, and hypoxia is associated with resistance to therapies and poor outcomes. A transmembrane protein that is upregulated by tumor cells that have adapted to hypoxic conditions is carbonic anhydrase IX (CAIX). Therefore, noninvasive imaging of CAIX could be of prognostic value, and it could steer treatment strategies. The aim of this study was to compare variants of CAIX-binding VHH B9, with and without a C-terminal albumin-binding domain with varying affinity (ABDlow and ABDhigh), for SPECT imaging of CAIX expression. The binding affinity and internalization of the various B9-variants were analyzed using SK-RC-52 cells. Biodistribution studies were performed in mice with subcutaneous SCCNij153 human head and neck cancer xenografts. Tracer uptake was determined by ex vivo radioactivity counting and visualized by SPECT/CT imaging. Furthermore, autoradiography images of tumor sections were spatially correlated with CAIX immunohistochemistry. B9-variants demonstrated a similar moderate affinity for CAIX in vitro. Maximal tumor uptake and acceptable tumor-to-blood ratios were found in the SCCNij153 model at 4 h post injection for [111In]In-DTPA-B9 (0.51 ± 0.08%ID/g and 8.1 ± 0.85, respectively), 24 h post injection for [111In]In-DTPA-B9-ABDlow (2.39 ± 0.44%ID/g and 3.66 ± 0.81, respectively) and at 72 h post injection for [111In]In-DTPA-B9-ABDhigh (8.7 ± 1.34%ID/g and 2.43 ± 0.15, respectively). An excess of unlabeled monoclonal anti-CAIX antibody efficiently inhibited tumor uptake of [111In]In-DTPA-B9, while only a partial reduction of [111In]In-DTPA-B9-ABDlow and [111In]In-DTPA-B9-ABDhigh uptake was found. Immunohistochemistry and autoradiography images showed colocalization of all B9-variants with CAIX expression; however, [111In]In-DTPA-B9-ABDlow and [111In]In-DTPA-B9-ABDhigh also accumulated in non-CAIX expressing regions. Tumor uptake of [111In]In-DTPA-B9-ABDlow and [111In]In-DTPA-B9-ABDhigh, but not of [111In]In-DTPA-B9, could be visualized with SPECT/CT imaging. In conclusion, [111In]In-DTPA-B9 has a high affinity to CAIX and shows specific targeting to CAIX in head and neck cancer xenografts. The addition of ABD prolonged plasma half-life, increased tumor uptake, and enabled SPECT/CT imaging. This uptake was, however, partly CAIX- independent, precluding the ABD-tracers for use in hypoxia quantification in this tumor type.


Asunto(s)
Anticuerpos Monoclonales , Neoplasias de Cabeza y Cuello , Albúminas/metabolismo , Animales , Anticuerpos Monoclonales/química , Antígenos de Neoplasias/metabolismo , Anhidrasa Carbónica IX/metabolismo , Línea Celular Tumoral , Semivida , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Hipoxia , Ratones , Ácido Pentético , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
2.
Phys Imaging Radiat Oncol ; 19: 145-150, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34485720

RESUMEN

BACKGROUND AND PURPOSE: Tumor hypoxia is an important cause of radioresistance and is associated with poor outcome.SPECT (Single-photon emission computed tomography) imaging enables visualizing tumor characteristics. We investigated the SPECT-radiotracer [111In]-girentuximab-F(ab')2 to image Carbonic Anhydrase IX (CAIX), an enzyme upregulated under hypoxic conditions. MATERIALS AND METHODS: Athymic mice with subcutaneous FaDu or SCCNij202 head and neck squamous cell carcinoma (HNSCC) xenografts were treated with atovaquone or were housed in a hypoxic chamber (8% O2). Next, [111In]-girentuximab-F(ab')2 was injected and 24 h later mice were euthanized for ex vivo biodistribution, autoradiography of the tumor, and immunohistochemical staining of the tumor. Tumor sections were analyzed for hypoxia, CAIX expression, vessels, and perfusion. Also, the effect of atovaquone on microSPECT scans was determined in the FaDu model. RESULTS: Atovaquone decreased CAIX expression by 69% (p = 0.017) compared with control tumors in FaDu, while in the SCCNij202 tumors no difference was observed. Hypoxic breathing did not increase CAIX expression or hypoxia staining in either tumor model, but did affect the necrotic tumor fraction. Ex vivo tracer uptake in the atovaquone treated group did not differ significantly from the control group, despite the difference in CAIX expression. Furthermore, SPECT imaging with [111In]-girentuximab-F(ab')2 did not discriminate atovaquone-treated versus control tumors. CONCLUSION: Atovaquone decreased CAIX expression only in the FaDu tumor model. [111In]-girentuximab-F(ab')2 specifically targets CAIX-expressing areas in HNSCC xenografts, but differences in vessel density and necrosis most likely affected tracer uptake in the tumors and therefore complicated quantification of changes in CAIX expression.

3.
Sci Rep ; 9(1): 18898, 2019 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-31827111

RESUMEN

Hypoxia-induced carbonic anhydrase IX (CAIX) expression is a prognostic marker in solid tumors. In recent years many radiotracers have been developed, but a fair comparison of these compounds is not possible because of the diversity in tumor models and other experimental parameters. In this study we performed a direct in vivo comparison of three promising CAIX targeting radiotracers in xenografted head and neck cancer models. The biodistribution of [111In]In-DOTA-ZCAIX:2 was directly compared with [111In]In-DTPA-G250-F(ab')2 and [111In] In-DTPA-G250 in female BALB/C nu/nu mice bearing two HNSCC xenografts with different levels of CAIX expression. In vivo biodistribution was quantified by means of microSPECT/CT scans and ex vivo biodistribution was determined with the use of a γ-counter. Tumors were snap frozen and sections were stained for CAIX expression, vessels, hypoxia (pimonidazole) and tumor blood perfusion. Tracer uptake was significantly higher in SSCNij153 tumors compared to SCCNij185 tumors for [111In]In-DOTA-HE3-ZCAIX:2: 0.32 ± 0.03 versus 0.18 ± 0.01%ID/g,(p = 0.003) 4 h p.i., for [111In]In-DTPA-girentuximab-F(ab')2: 3.0 ± 0.5%ID/g and 1.2 ± 0.1%ID/g (p = 0.03), 24 h p.i. and for [111In]In-DTPA-girentuximab: 30 ± 2.1%ID/g and 7.0 ± 1.0%ID/g (p = 0.0002) 72 h p.i. SPECT imaging with both [111In]In-DTPA-girentuximab-F(ab')2 and [111In]In-DTPA-girentuximab showed a clear difference in tracer distribution between the two tumor models. The whole IgG, i.e. [111In]In-DTPA-girentuximab, showed the highest tumor-to-muscle ratio. We showed that different CAIX-targeting radiotracers can discriminate a low CAIX-expressing tumor from a high CAIX-expressing head and neck cancer xenografts model. In these hypoxic head and neck xenograft models [111In]In-DTPA-girentuximab showed the most promising results.


Asunto(s)
Anhidrasa Carbónica IX/metabolismo , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Animales , Femenino , Ratones , Ratones Endogámicos BALB C , Ensayos Antitumor por Modelo de Xenoinjerto
4.
Sci Rep ; 9(1): 14907, 2019 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-31624303

RESUMEN

Carbonic anhydrase IX (CAIX) is a cancer-associated molecular target for several classes of therapeutics. CAIX is overexpressed in a large fraction of renal cell carcinomas (RCC). Radionuclide molecular imaging of CAIX-expression might offer a non-invasive methodology for stratification of patients with disseminated RCC for CAIX-targeting therapeutics. Radiolabeled monoclonal antibodies and their fragments are actively investigated for imaging of CAIX expression. Promising alternatives are small non-immunoglobulin scaffold proteins, such as affibody molecules. A CAIX-targeting affibody ZCAIX:2 was re-designed with the aim to decrease off-target interactions and increase imaging contrast. The new tracer, DOTA-HE3-ZCAIX:2, was labeled with 111In and characterized in vitro. Tumor-targeting properties of [111In]In-DOTA-HE3-ZCAIX:2 were compared head-to-head with properties of the parental variant, [99mTc]Tc(CO)3-HE3-ZCAIX:2, and the most promising antibody fragment-based tracer, [111In]In-DTPA-G250(Fab')2, in the same batch of nude mice bearing CAIX-expressing RCC xenografts. Compared to the 99mTc-labeled parental variant, [111In]In-DOTA-HE3-ZCAIX:2 provides significantly higher tumor-to-lung, tumor-to-bone and tumor-to-liver ratios, which is essential for imaging of CAIX expression in the major metastatic sites of RCC. [111In]In-DOTA-HE3-ZCAIX:2 offers significantly higher tumor-to-organ ratios compared with [111In]In-G250(Fab')2. In conclusion, [111In]In-DOTA-HE3-ZCAIX:2 can be considered as a highly promising tracer for imaging of CAIX expression in RCC metastases based on our results and literature data.


Asunto(s)
Anhidrasa Carbónica IX/antagonistas & inhibidores , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Imagen Molecular/métodos , Sondas Moleculares/administración & dosificación , Animales , Anticuerpos Monoclonales/administración & dosificación , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/farmacología , Antígenos de Neoplasias/inmunología , Antígenos de Neoplasias/metabolismo , Anhidrasa Carbónica IX/inmunología , Anhidrasa Carbónica IX/metabolismo , Carcinoma de Células Renales/patología , Línea Celular Tumoral , Femenino , Humanos , Fragmentos de Inmunoglobulinas/administración & dosificación , Fragmentos de Inmunoglobulinas/inmunología , Fragmentos de Inmunoglobulinas/farmacología , Radioisótopos de Indio , Neoplasias Renales/patología , Ratones , Sondas Moleculares/química , Sondas Moleculares/inmunología , Sondas Moleculares/farmacología , Trazadores Radiactivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Distribución Tisular , Ensayos Antitumor por Modelo de Xenoinjerto
5.
Mol Pharm ; 16(2): 701-708, 2019 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-30550290

RESUMEN

Tumor hypoxia plays a major role in radio- and chemotherapy resistance in solid tumors. Carbonic Anhydrase IX (CAIX) is an endogenous hypoxia-related protein, which is associated with poor patient outcome. The quantitative assessment of CAIX expression of tumors may steer cancer treatment by predicting therapy response or patient selection for antihypoxia or CAIX-targeted treatment. Recently, the single-photon emission computerized tomography (SPECT) tracer [111In]In-DTPA-girentuximab-F(ab')2 was developed and validated for targeting CAIX. The aim of this study was to optimize quantitative microSPECT/CT of CAIX expression in vivo in head and neck tumor models. Athymic mice with subcutaneous SCCNij153 and SCCNij202 head and neck squamous cell carcinoma xenografts were injected with [111In]In-DTPA-girentuximab-F(ab')2. First, the protein dose, timing, and image acquisition settings were optimized. Tracer uptake was determined by quantitative SPECT, ex vivo radioactivity counting, and by autoradiography of tumor sections. The same tumor sections were immunohistochemically stained for CAIX expression and hypoxia. Highest tumor-normal-tissue contrast was obtained at 24 h after injection of the tracer. A protein dose of 10 µg resulted in the highest tumor-to-muscle ratio at 24 h p.i. Ex vivo biodistribution studies showed a tumor uptake of 3.0 ± 0.6%ID/g and a tumor-to-muscle ratio of 8.7 ± 1.4 (SCCNij153). Quantitative analysis of the SPECT images enabled us to distinguish CAIX antigen blocked from nonblocked tumors, fractions positive for CAIX expression: 0.22 ± 0.02 versus 0.08 ± 0.01 ( p < 0.01). Immunohistochemical, autoradiographic, and microSPECT/CT analyses showed a distinct intratumoral spatial correlation between localization of the radiotracer and CAIX expression. Here, we demonstrate that [111In]In-DTPA-girentuximab-F(ab')2 specifically targets CAIX-expressing cells in head and neck cancer xenografts. SPECT imaging with indium-labeled girentuximab-F(ab')2 allows quantitative assessment of the fraction of CAIX positive tissue in head and neck cancer xenografts. These results indicate that [111In]In-DTPA-girentuximab-F(ab')2 is a promising tracer to image hypoxia-related CAIX expression.


Asunto(s)
Anhidrasa Carbónica IX/metabolismo , Hipoxia/diagnóstico por imagen , Hipoxia/metabolismo , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/metabolismo , Animales , Anticuerpos Monoclonales/farmacocinética , Anticuerpos Monoclonales/uso terapéutico , Autorradiografía , Inmunohistoquímica , Ratones , Ratones Desnudos , Nitroimidazoles/farmacocinética , Nitroimidazoles/uso terapéutico , Carcinoma de Células Escamosas de Cabeza y Cuello/tratamiento farmacológico , Tomografía Computarizada de Emisión de Fotón Único
6.
Radiother Oncol ; 124(3): 521-525, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28789809

RESUMEN

BACKGROUND AND PURPOSE: Hypoxia is a major cause of radio- and chemoresistance. Carbonic anhydrase IX (CAIX) is an endogenous hypoxia-related marker and an important prognostic marker. Assessment of CAIX expression may allow patient selection for hypoxia or CAIX-targeted treatment. The radioactive tracer 111In-girentuximab-F(ab')2 targets CAIX and can be used for SPECT imaging. Aim of this study was to validate and optimize 111In-girentuximab-F(ab')2 for imaging of CAIX expression in head and neck tumor xenografts. MATERIAL AND METHODS: Affinity and internalization kinetics of 111In-girentuximab-F(ab')2 were determined in vitro using CAIX-expressing SK-RC-52 cells. Tumor targeting characteristics were determined in athymic mice with six different head and neck squamous cell carcinoma (SCCNij) xenografts. Tracer uptake was measured by ex vivo radioactivity counting. Intratumoral distribution of tracer uptake was measured using autoradiography and CAIX expression was determined immunohistochemically. RESULTS: 26% of the tracer was internalized into the SK-RC-52 cells within 24h. The half maximal inhibitory concentration (IC50) was 0.69±0.08nM. In biodistribution studies SCCNij153 tumors showed the highest tracer uptake: 4.1±0.8ID/g at 24h p.i. Immunohistochemical and autoradiographic analyses of the xenografts showed a distinct spatial correlation between localization of the tracer and CAIX expression. CONCLUSION: 111In-girentuximab-F(ab')2 has a high affinity for CAIX. In vivo tumor uptake correlated strongly with CAIX expression in different head and neck xenografts. These results suggest that 111In-girentuximab-F(ab')2 is a promising tracer for imaging of hypoxia-related CAIX expression.


Asunto(s)
Anticuerpos Monoclonales , Anhidrasa Carbónica IX/análisis , Hipoxia de la Célula , Neoplasias de Cabeza y Cuello/enzimología , Animales , Anticuerpos Monoclonales/farmacocinética , Autorradiografía , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Ratones , Ratones Endogámicos BALB C , Trasplante de Neoplasias , Tomografía Computarizada de Emisión de Fotón Único/métodos , Trasplante Heterólogo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...