Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 92(2): 807-819, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38469904

RESUMEN

PURPOSE: To develop and validate a noninvasive imaging technique for accurately assessing very slow CSF flow within shunt tubes in pediatric patients with hydrocephalus, aiming to identify obstructions that might impede CSF drainage. THEORY AND METHODS: A simulation of shunt flow enhancement of signal intensity (shunt-FENSI) signal is used to establish the relationship between signal change and flow rate. The quantification of flow enhancement of signal intensity data involves normalization, curve fitting, and calibration to match simulated data. Additionally, a phase sweep method is introduced to accommodate the impact of magnetic field inhomogeneity on the flow measurement. The method is tested in flow phantoms, healthy adults, intensive care unit patients with external ventricular drains (EVD), and shunt patients. EVDs enable shunt-flow measurements to be acquired with a ground truth measure of CSF drainage. RESULTS: The flow-rate-to-signal simulation establishes signal-flow relationships and takes into account the T1 of draining fluid. The phase sweep method accurately accounts for phase accumulation due to frequency offsets at the shunt. Results in phantom and healthy human participants reveal reliable quantification of flow rates using controlled flows and agreement with the flow simulation. EVD patients display reliable measures of flow rates. Shunt patient results demonstrate feasibility of the method and consistent flow rates for functional shunts. CONCLUSION: The results demonstrate the technique's applicability, accuracy, and potential for diagnosing and noninvasively monitoring hydrocephalus. Limitations of the current approach include a high sensitivity to motion and strict requirement of imaging slice prescription.


Asunto(s)
Derivaciones del Líquido Cefalorraquídeo , Hidrocefalia , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Masculino , Femenino , Reproducibilidad de los Resultados , Simulación por Computador , Niño , Líquido Cefalorraquídeo/diagnóstico por imagen , Líquido Cefalorraquídeo/fisiología , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Magn Reson Imaging Clin N Am ; 21(2): 279-98, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23642554

RESUMEN

The potential utility of diffusion tensor (DT) imaging in clinical practice is broad, and new applications continue to evolve as technology advances. Clinical applications of DT imaging and tractography include tissue characterization, lesion localization, and mapping of white matter tracts. DT imaging metrics are sensitive to microstructural changes associated with central nervous system disease; however, further research is needed to enhance specificity so as to facilitate more widespread clinical application. Preoperative tract mapping, with either directionally encoded color maps or tractography, provides useful information to the neurosurgeon and has been shown to improve clinical outcomes.


Asunto(s)
Encefalopatías/patología , Encefalopatías/cirugía , Imagen de Difusión Tensora/métodos , Aumento de la Imagen/métodos , Fibras Nerviosas Mielínicas/patología , Cirugía Asistida por Computador/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...