Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Surg Case Rep ; 2024(7): rjae456, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38993817

RESUMEN

Incisional hernia refers to an abdominal wall defect at the site of a previous surgical incision. In this paper, we describe two patients who previously underwent open kidney stone surgery several years ago and had the ipsilateral recurrent stones. They were both managed by a mini percutaneous nephrolithotripsy (PCNL) to treat kidney stones. Case 1 was a 50-year-old female with right recurrent staghorn stones after 5 years of open surgery and required two PCNL procedures to achieve stone-free status. Case 2 was a 74-year-old male with significant comorbidities who had a right 27 mm recurrent kidney stone after 10 years of open nephrolithotomy. Both patients experienced no postoperative complications after PCNL. These cases show that in cases of lumbar incisional scar hernias, mini PCNL with ultrasound guidance and proper patient positioning can be an optimal approach for kidney stone treatment.

2.
J Med Case Rep ; 18(1): 262, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38802967

RESUMEN

BACKGROUND: The duplex kidney is one of the common congenital anomalies of the kidney and urinary tract. We present two cases of renal tumor accompanied with ipsilateral duplex kidney. The image of the tumor, renal artery system and collecting system were rendered by AI software (Fujifilm's Synapse® AI Platform) to support the diagnosis and surgical planning. CASE PRESENTATION: Two Vietnamese patients (a 45-year-old man and a 54-year-old woman) with incidental cT1 renal cell carcinoma (RCC) were confirmed to have ipsilateral duplex kidneys by 3D reconstruction AI technique. One patient had a Renal score 9ah tumor of left kidney while the other had a Renal score 9 × tumor of right kidney in which a preoperative CT scan failed to identify a diagnosis of duplex kidney. Using the Da Vinci platform, we successfully performed robotic partial nephrectomy without any damage to the collecting system in both cases. CONCLUSION: RCC with duplex kidneys is a rare condition. By utilizing a novel AI reconstruction technique with adequate information, two patients with RCC in duplex kidneys were successfully performed robotic partial nephrectomy without complication.


Asunto(s)
Carcinoma de Células Renales , Imagenología Tridimensional , Neoplasias Renales , Riñón , Nefrectomía , Procedimientos Quirúrgicos Robotizados , Humanos , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Persona de Mediana Edad , Nefrectomía/métodos , Neoplasias Renales/cirugía , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Riñón/anomalías , Tomografía Computarizada por Rayos X
3.
ACS Appl Electron Mater ; 5(1): 189-195, 2023 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-36711042

RESUMEN

In this paper, we present a broadband microwave characterization of ferroelectric hafnium zirconium oxide (Hf0.5Zr0.5O2) metal-ferroelectric-metal (MFM) thin film varactor from 1 kHz up to 0.11 THz. The varactor is integrated into the back-end-of-line (BEoL) of 180 nm CMOS technology as a shunting capacitor for the coplanar waveguide (CPW) transmission line. At low frequencies, the varactor shows a slight imprint behavior, with a maximum tunability of 15% after the wake-up. In the radio- and mmWave frequency range, the varactor's maximum tunability decreases slightly from 13% at 30 MHz to 10% at 110 GHz. Ferroelectric varactors were known for their frequency-independent, linear tunability as well as low loss. However, this potential was never fully realized due to limitations in integration. Here, we show that ferroelectric HfO2 thin films with good back-end-of-line compatibility support very large scale integration. This opens up a broad range of possible applications in the mmWave and THz frequency range such as 6G communications, imaging radar, or THz imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...