Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
ACS Appl Mater Interfaces ; 13(10): 11869-11878, 2021 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-33660500

RESUMEN

Solar thermal distillation is a promising way to harvest clean water due to its sustainability. However, the energy density of solar irradiation inevitably demands scalability of the systems. To realize practical applications, it is highly desirable to fabricate meter-scale solar evaporator panels with high capillary performance as well as optical absorptance using scalable and high-throughput fabrication methods. Here, we demonstrate a truly scalable fabrication process for a bi-facial solar evaporator with copper oxide dendrites via the hydrogen bubble templated electrochemical deposition technique. Furthermore, we construct a theoretical model combining capillarity and evaporative mass transfer, which leads to optimal operation conditions and wick characteristics, including superhydrophilicity, extreme capillary performance, and omni-angular high optical absorptance. The fabricated porous surfaces with excellent capillary performance and productivity provide a pathway toward a highly efficient bi-facial solar evaporator panel with meter-level scalability.

2.
J Vet Med Sci ; 82(9): 1321-1328, 2020 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-32684615

RESUMEN

Oxygen-induced cerebrospinal fluid (CSF) hyperintensity artifact is inevitable in fluid attenuation inversion recovery (FLAIR) magnetic resonance (MR) images of anesthetized animals. This experimental study aimed to confirm the occurrence of this artifact on low-field magnetic resonance imaging (MRI), and to determine the fraction of inspired oxygen (FiO2) that is safe and does not induce this artifact in canine brain MRI. Six healthy dogs underwent brain FLAIR MR scans under general anesthesia with 21%, 30%, 50%, 70%, and 100% FiO2. The signal intensity (SI) ratio was calculated as the SI of CSF spaces divided by that of normalizing regions. The SI ratios of 21% FiO2 images were significantly different from those of 100% FiO2 images, indicating the presence of artifacts on 100% FiO2 images. The SI ratios of 30% FiO2 images were not significantly different from those of 21% FiO2 images for any of CSF spaces. However, they were significantly different from those of 100% FiO2 images in the cerebral sulci, third ventricle, interpeduncular cistern, mesencephalic aqueduct, and subarachnoid space at the level of the first cervical vertebra (P<0.05). All dogs had normal partial pressure of arterial oxygen (PaO2) during inhalation of 30% FiO2, while two dogs had low PaO2 during inhalation of 21% FiO2. Our findings support the hypothesis that high FiO2 induces CSF hyperintensity artifact on low-field FLAIR MR images in dogs. FiO2 of 30% is appropriate for obtaining brain FLAIR MR images with fewer artifacts in dogs.


Asunto(s)
Imagen por Resonancia Magnética , Oxígeno , Animales , Artefactos , Encéfalo/diagnóstico por imagen , Líquido Cefalorraquídeo , Perros , Imagen por Resonancia Magnética/veterinaria , Espacio Subaracnoideo
3.
Am J Vet Res ; 80(9): 825-831, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31449446

RESUMEN

OBJECTIVE: To assess effects of catheter diameter and injection rate of flush solution (saline [0.9% NaCl] solution) on renal contrast-enhanced ultrasonography (CEUS) with perfluorobutane in dogs. ANIMALS: 5 healthy Beagles. PROCEDURES: CEUS of the kidneys was performed by IV injection of contrast medium (0.0125 mL/kg) followed by injection of 5 mL of saline solution at rates of 1, 3, and 5 mL/s through a 20-gauge or 24-gauge catheter; thus, CEUS was repeated 3 times for each catheter diameter. Time-intensity curves were created for regions of interest drawn in the renal cortex and medulla. Repeatability was determined by calculating the coefficient of variation (CV). Statistical analysis was used to assess whether perfusion variables or CV of the perfusion variables was associated with catheter diameter or injection rate. RESULTS: Perfusion variables did not differ significantly between catheter diameters. Time to peak enhancement (TTP) in the renal cortex was affected by injection rate, and there were significantly lower values for TTP at higher injection rates. The CEUS variables with the lowest CVs among injection rates were TTP for the renal cortex; the CV for TTP of the renal cortex was the lowest at an injection rate of 5 mL/s. CONCLUSIONS AND CLINICAL RELEVANCE: Use of a 24-gauge catheter did not alter CEUS with perfluorobutane; therefore, such catheters could be used for CEUS of the kidneys of small dogs. Moreover, a rate of 5 mL/s is recommended for injection of flush solution to obtain greater accuracy for renal CEUS in Beagles.


Asunto(s)
Catéteres de Permanencia , Perros , Fluorocarburos/administración & dosificación , Riñón/diagnóstico por imagen , Ultrasonografía/veterinaria , Animales , Medios de Contraste/administración & dosificación , Femenino , Inyecciones Intravenosas , Riñón/metabolismo , Masculino , Perfusión
4.
Am J Vet Res ; 80(1): 61-68, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30605030

RESUMEN

OBJECTIVE To assess the feasibility of esophageal insufflation CT (EICT) for evaluation of the esophagus in dogs. ANIMALS 7 clinically normal adult Beagles. PROCEDURES Each dog was anesthetized twice with 1 week between anesthesia sessions. Dogs were positioned in sternal recumbency during all CT scans. During the first anesthesia session, a CT scan was performed before the esophagus was insufflated (insufflation pressure, 0 mm Hg) and unenhanced and contrast-enhanced EICT scans were performed after CO2 was insufflated into the esophageal lumen to achieve a pressure of 5 mm Hg. For the contrast-enhanced scan, each dog received iohexol (600 mg/kg, IV), and the scan was performed 30 seconds later. During the second anesthesia session, unenhanced and contrast-enhanced EICT scans were performed in the same manner except the insufflation pressure achieved was 10 mm Hg. The esophageal luminal cross-sectional area and wall thickness were measured at each of 5 segments, and mean values were compared among the 3 insufflation pressures and between unenhanced and contrast-enhanced images. RESULTS Mean esophageal luminal cross-sectional area increased and esophageal wall thickness decreased as insufflation pressure increased. Measurements did not differ significantly between unenhanced and contrast-enhanced images. The stomach became distended with CO2 at an insufflation pressure of 10 mm Hg but not at 5 mm Hg. No adverse effects were observed. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested EICT was feasible for esophageal evaluation in dogs. Further research is necessary to determine the optimal insufflation pressure for the procedure and its diagnostic efficacy in diseased patients.


Asunto(s)
Perros/fisiología , Esófago/diagnóstico por imagen , Insuflación/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Animales , Esófago/fisiología , Femenino , Mucosa Gástrica/diagnóstico por imagen , Mucosa Gástrica/fisiología , Masculino , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...