RESUMEN
PURPOSE: To evaluate the effect of drug-coated balloon (DCB) with high-dose paclitaxel for the treatment of restenotic dysfunctional arteriovenous fistulae (AVFs). MATERIALS AND METHODS: In this single-arm, multicenter, prospective, observational study, 334 patients who underwent DCB angioplasty using IN.PACT AV (Medtronic, Plymouth, Minnesota) for the first time for restenotic lesions of dysfunctional AVFs between April 2021 and March 2022 were registered. Outcomes were compared with the outcomes of plain angioplasty performed previously, leading up to the restenosis. RESULTS: Procedural success, defined as <30% residual stenosis, was achieved in 96.7% of cases. During a median follow-up of 7.4 months, 179 target lesion reinterventions (TLRs) were observed, and the 6-month freedom from TLR was 73.2% (68.2%-78.2%). When compared with the previous plain angioplasty, the median time to reintervention was significantly longer with DCB (9.1 [8.0-10.6] vs 3.2 [3.0-3.4] months; P < .001). Baseline characteristics that were independently associated with TLR were as follows: months from the last intervention (adjusted hazard ratio, 0.50 [95% confidence interval, 0.40-0.62] per doubling; P < .001), partial lesion coverage by DCB (2.13 [1.10-4.12]; P = .024), and residual stenosis after DCB (2.19 [1.53-3.12] per 15% increase; P < .001) with its time interaction (0.91 [0.86-0.97] per month; P = .003). Of the 179 TLRs, 84 used DCB once again. The median time to reintervention was significantly longer for TLR using DCB (7.1 [6.2-9.7] vs 3.3 [3.1-4.0] months; P < .001). CONCLUSIONS: DCB with high-dose paclitaxel is effective at both the initial treatment of restenotic lesions of dysfunctional AVFs and during TLR after DCB use. Partial lesion coverage by DCB and residual stenosis may compromise patency.
RESUMEN
Purpose: During thoracic endovascular aortic repair for complicated Stanford type B aortic dissection, large bare stent placement for the abdominal aorta is sometimes necessary. In smaller abdominal aortic diameter cases, we used the stripped AFX aortic cuff as a scaffolding bare stent rather than the Zenith Dissection Endovascular Stent, which is a commercially available, large bare stent. In this study, we evaluated the feasibility of the stripped AFX aortic cuff and experiments were conducted to compare the stripped AFX and the Zenith Dissection Endovascular Stent. Material and Method: The type B aortic dissection patients treated with thoracic endovascular aortic repair using stripped AFX at three institutions between January 2014 and December 2017 were retrospectively reviewed. Clinical data, including technical success, perioperative complication, and overall survival, were evaluated. The experiment assessed the chronic outward force that reflected the load acting on the artery wall from the stent. Result: Eight cases (seven males) were reviewed. The median (interquartile range, IQR) age of the patients was 60 years (46.3-70.3). The technical success rate was 100%, and no perioperative complications were observed. The median (IQR) follow-up period was 28.9 months (17.5-31.5). During the follow-up, one patient died of septic shock unrelated to aortic events. The median (IQR) diameter of the stripped AFX on the last follow-up CT was 23.5 mm (21.9-25.0). The chronic outward force of the Zenith Dissection Endovascular Stent was two to three times that of the stripped AFX. Conclusions: The stripped AFX aortic cuff is feasible and safe as a scaffolding stent during thoracic endovascular aortic repair for Stanford Type B aortic dissection.
RESUMEN
PURPOSE: Clinical trials have demonstrated that high-dose drug-coated balloon (HD-DCB) and polymer-based drug-eluting stent (PB-DES) treatments for femoropopliteal (FP) artery disease have favorable outcomes. However, which one would be better remained unrevealed. METHODS: This study used the databases of 2 large-scale multicenter prospective drug-coated balloon (DCB) and drug-eluting stent (DES) registries. The study included 2470 patients with symptomatic FP lesion treated with IN.PACT Admiral DCB or Eluvia DES at 69 centers. A propensity-score-based paired analysis was conducted. Primary endpoint was 1-year restenosis rate. Secondary endpoints were 1-year reocclusion rate, target lesion revascularization (TLR), acute thrombosis, bypass conversion, major amputation, major adverse limb event (MALE), and all-cause death. RESULTS: A total of 1535 patients were treated with HD-DCB, and 935 patients were treated with PB-DES. The propensity-score matching extracted 678 pairs, with no remarkable intergroup difference in baseline characteristics. The 1-year restenosis rate was significantly lower in the PB-DES group than in the HD-DCB group (16.0% vs 22.0%, p=0.016). The other endpoints (reocclusion rate, TLR, acute thrombosis, bypass conversion, major amputation, MALE, and all-cause death) did not differ between the groups. No baseline characteristics had any significant interaction effect on the association of HD-DCB vs PB-DES with restenosis risk (all p>0.05). CONCLUSIONS: This study demonstrated that the 1-year TLR, reocclusion rate, and other endpoints did not differ between the PB-DES group and the HD-DCB group despite the lower restenosis in the PB-DES group. CLINICAL IMPACT: One-year restenosis rate was significantly lower in the polymer-based DES group than in the high-dose DCB group for foemoropopliteal disease. However, there is no difference in the other endpoints between two groups.
RESUMEN
BACKGROUND: Sirolimus-coated balloons (SCB) for the treatment of femoropopliteal (FP) lesions have not been systematically studied, but initial outcomes from early studies are promising. OBJECTIVES: The authors sought to evaluate the safety and efficacy of the SELUTION SLR SCB, composed of proprietary microreservoir technology combining sirolimus and biodegradable polymer, when used to treat mild-to-moderate FP disease in a Japanese population. METHODS: This multicenter, prospective, single-arm study (SELUTION SFA JAPAN) enrolled 134 patients with FP disease. It was independently adjudicated by an imaging core laboratory and clinical events committee. The primary endpoint was 12-month primary patency, defined as peak systolic velocity ratio ≥2.5 by duplex ultrasound and compared against a prespecified performance goal of 60% based on established angioplasty data. RESULTS: The mean age was 73.8 ± 6.9 years, and 60.3% of patients had diabetes mellitus. The mean lesion length was 127.4 ± 59.7 mm, 17.2% were chronic total occlusions, and 47.8% involved the popliteal artery. Data on 12-month restenosis were available in 127 patients (94.8%). The 12-month primary patency rate was 87.9%, and the freedom from clinically driven target lesion revascularization (CD-TLR) was 97.0% per Kaplan-Meier estimate. The major adverse event rate was 6.7%, driven by 4 CD-TLRs and 5 deaths, none of which were related to the device or procedure. Ankle-brachial index data improved significantly from 0.73 ± 0.16 at baseline to 0.96 ± 0.14 at 30 days postprocedure and was sustained through 12 months (0.94 ± 0.13). CONCLUSIONS: The SELUTION SFA JAPAN trial demonstrated that a novel SELUTION SCB is a safe and effective treatment option for FP disease in symptomatic patients.
Asunto(s)
Angioplastia de Balón , Fármacos Cardiovasculares , Materiales Biocompatibles Revestidos , Arteria Femoral , Enfermedad Arterial Periférica , Arteria Poplítea , Sirolimus , Dispositivos de Acceso Vascular , Grado de Desobstrucción Vascular , Humanos , Arteria Poplítea/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Anciano , Masculino , Femenino , Arteria Femoral/fisiopatología , Arteria Femoral/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/diagnóstico por imagen , Estudios Prospectivos , Japón , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/efectos adversos , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversos , Factores de Tiempo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Anciano de 80 o más Años , Recurrencia , Resultado del Tratamiento , Diseño de Equipo , Factores de Riesgo , Persona de Mediana EdadRESUMEN
We report a rare case of jaw claudication following fenestrated thoracic endovascular aortic repair for a saccular aortic arch aneurysm. The brachiocephalic artery (BCA) was preserved with fenestration and intentionally half covered. Although discharged without any complications 2 weeks after the procedure, the patient subsequently experienced right mandibular fatigue at mealtime and hypotension in the right upper extremity. Angiography revealed a flap-like structure in the BCA orifice, with a 100-mm Hg pressure gradient between the aorta and BCA. Intravascular ultrasound revealed a stenosed BCA with a cord-like structure, which was considered a graft protrusion. Bare metal stenting was performed, which promptly resolved the symptoms.
RESUMEN
PURPOSE: Recent reports of the Zenith Alpha abdominal endovascular graft (Zenith Alpha AAA, Cook, Inc., Bloomington, Indiana) have demonstrated an unexpectedly high incidence of limb graft occlusion (LGO). The purpose of this study was to prospectively evaluate the performance of the Zenith AAA in Japan, with a specific focus on LGO. MATERIALS AND METHODS: All endovascular aneurysm repairs (EVARs) for abdominal aortic aneurysms performed using the Zenith Alpha AAA from July 2020 to October 2021 in 23 Japanese hospitals were prospectively evaluated. All computed tomographic images were analyzed in the core laboratory. Late complications were defined as any aneurysm-related events occurring >30 days after EVAR, including aneurysm sac enlargement of >5 mm and any reinterventions performed. Endoleaks without sac enlargement or reintervention were excluded as late complications. RESULTS: During the study period, 147 EVARs were performed using the Zenith Alpha AAA. The mean patient age was 76.5±7.7 years, 84.4% of patients were male, and the mean aneurysm diameter was 52.4±9.2 mm. Instruction-for-use violations were observed in 76 patients (51.7%), primarily associated with a severely angulated proximal neck (>60°). There were six intraoperative complications and 62 additional intraoperative treatments reported, most of which involved preemptive coil embolization of the inferior mesenteric artery (37 cases). Technical success, defined as the absence of type 1 or 3 endoleaks on final angiography, was achieved in 99.3% of patients. At 12 months, there was only one case of type 1/3 endoleak (0.8%) and one aneurysm sac enlargement exceeding 5 mm (0.8%); however, a high incidence of type 2 endoleaks was observed in 35.2% of patients, and aneurysm sac regression exceeding 5 mm was achieved in 30.1% of patients. Nine late complications were observed, and the rate of freedom from late complications at 12 months was 93.5%, encompassing four LGOs and one limb graft stenosis (3.4%). CONCLUSIONS: In contrast to recent reports, our Japanese multicenter prospective study demonstrated satisfactory early clinical results, including an acceptable LGO rate, for the low-profile Zenith Alpha AAA. Long-term follow-ups will be performed to confirm the persistence of these outcomes. CLINICAL IMPACT: This study prospectively evaluated the performance of 147 Zenith Alpha AAAs used for endovascular aneurysm repair with core-lab adjudication focusing especially on limb graft occlusion (LGO). At 12 months, aneurysm sac regression exceeding 5 mm was achieved in 30.1% of patients, and there was only one type 1/3 endoleak, one aneurysm sac enlargement (>5 mm), and nine late complications including five LGOs (3.4%), resulting in rate of freedom from late complications at 93.5%. Satisfactory early clinical results, including an acceptable rate of LGO can be achieved, particularly with cautious usage of the Zenith Alpha Spiral-Z Endovascular Leg." 5mm), and nine late complications including five LGOs (3.4%), resulting in rate of freedom from late complications at 93.5%. Satisfactory early clinical results, including an acceptable rate of LGO can be achieved, particularly with cautious usage of the Zenith Alpha Spiral-Z Endovascular Leg.
RESUMEN
BACKGROUND: Juxtarenal aortic occlusion (JRAO), in which the occlusion of the aorta extends to just below the renal artery, is often treated by bypass surgery because of concerns about the risk of procedural failure and fatal embolization to abdominal organs when treated with endovascular treatment (EVT). This study assessed the outcome of EVT for JRAO compared with aorto-biiliac /aorto-bifemoral (AOB) or axillo-bifemoral (AXB) bypass. METHODS: A retrospective review of an international database created by 30 centers in Asia (CHronic Abdominal Aortic Occlusion, ASian Multicenter registry) was performed for patients who underwent revascularization for chronic total occlusion of the infrarenal aorta from 2007 to 2017. Of the 436 patients, 130 with JRAO (Forty-seven AOBs, 32 AXBs, and 51 EVTs) from 25 institutions were included in this study. RESULTS: Patients were significantly older in the AXB and EVT groups and more malnourished in the EVT group than the AOB group. EVT was attempted but failed in 1 patient. Seven patients (1 [2.1%] in the AOB group, 1 [3.1%] in the AXB group, and 5 [9.8%] in the EVT group) died during hospitalization, but most of the causes in the EVT group were not related to the revascularization procedure. No visceral embolism was observed, which had been concerned, even though protection was performed only in 2 cases of the EVT group. At the latest follow-up (median duration 3.0 years), the ankle-brachial pressure index was significantly higher in the order of AOB, EVT, and AXB. At 4 years, the estimated primary and secondary patency rates of the AOB group (87.5% and 90.3%, respectively) were significantly higher than the AXB group (66.7% and 68.6%, respectively). CONCLUSIONS: AOB remains the gold standard and should be the first choice for acceptable risk patients. For frail patients, EVT is a good option and likely preferable as a first-line treatment compared to AXB.
Asunto(s)
Aorta Abdominal , Enfermedades de la Aorta , Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Sistema de Registros , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/instrumentación , Masculino , Estudios Retrospectivos , Femenino , Anciano , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Enfermedad Crónica , Persona de Mediana Edad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/instrumentación , Asia , Aorta Abdominal/cirugía , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Enfermedades de la Aorta/mortalidad , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/cirugía , Arteriopatías Oclusivas/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Grado de Desobstrucción Vascular , Anciano de 80 o más Años , Bases de Datos Factuales , Medición de RiesgoRESUMEN
BACKGROUND: Although the 1-year clinical outcomes of fluoropolymer-based drug-eluting stents (FP-DES) were favorable for the treatment of real-world femoropopliteal lesions in symptomatic peripheral artery disease (PAD), their performance beyond 1 year remained unknown. The current study determined the 3-year clinical course of FP-DES implantation for real-world femoropopliteal lesions. METHODS: This multicenter, prospective, observational study evaluated 1204 limbs (chronic limb-threatening ischemia, 34.8%; mean lesion length, 18.6 ± 9.9 cm, chronic total occlusion: 53.2%) of 1097 patients with PAD (age, 75 ± 9 years; diabetes mellitus, 60.8%) undergoing FP-DES implantation for femoropopliteal lesions. The primary outcome measure was 3-year restenosis. The secondary outcome measures included 3-year occlusive restenosis, stent thrombosis, target lesion revascularization (TLR), and aneurysmal degeneration. RESULTS: The 3-year cumulative occurrence of restenosis was 27.3%, whereas that of occlusive restenosis, stent thrombosis, and TLR was 16.1%, 7.3%, and 19.6%, respectively. The annual occurrence of restenosis decreased by 12.0%, 9.5%, and 5.8% in the first, second, and third year, respectively (p < 0.001). Similarly, the rates of occlusive restenosis and stent thrombosis decreased (p < 0.001 and p = 0.007, respectively), whereas the rate of TLR remained unchanged for 3 years (p = 0.15). The incidence of aneurysmal degeneration at 3 years (15.7%) did not significantly differ from that at 1 and 2 years (p = 0.69 and 0.20, respectively). CONCLUSIONS: This study highlights the favorable long-term clinical course of FP-DES in real-world practice, emphasizing the importance of monitoring for occlusive restenosis and stent thrombosis while considering the potential onset of aneurysmal degeneration.
Asunto(s)
Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Trombosis , Humanos , Anciano , Anciano de 80 o más Años , Arteria Femoral/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Polímeros de Fluorocarbono , Resultado del Tratamiento , Estudios Prospectivos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Progresión de la Enfermedad , Grado de Desobstrucción Vascular , Diseño de PrótesisRESUMEN
Introduction: The safety and effectiveness of the GORE VIABAHN Endoprosthesis for treatment of symptomatic patients with peripheral artery disease (PAD) and complex femoropopliteal (FP) lesions was assessed in a real-world Japanese practice setting. Methods: A prospective, multicenter, postmarket surveillance study was conducted from 2016 to 2017 at 64 sites in Japan. Symptomatic patients with PAD and FP lesions ⩾ 10 cm and reference vessel diameters ranging from 4.0 to 7.5 mm were eligible for enrollment. Outcome measures evaluated at 5 years were primary patency (PP), primary-assisted patency (PAP), secondary patency (SP), freedom from target lesion revascularization (fTLR), occurrence of device- or procedure-related serious adverse events (SAEs), and stent fractures. Results: A total of 321 patients were enrolled and were a mean age of 73.9 ± 8.7 years; 77.3% were men and 26.5% had chronic limb-threatening ischemia (CLTI). The mean lesion length was 23.6 ± 6.6 cm and the frequency with TASC II C/D lesions and chronic total occlusions was 86.6% and 70.4%, respectively. The Kaplan-Meier estimated PP, PAP, SP, and fTLR at 5 years was 62.4%, 74.1%, 82.3%, and 75.9%, respectively. The mean ankle-brachial index was 0.92 ± 0.15 and the mean improvement in Rutherford class was 2.3 ± 1.4, which was maintained through 5 years. The rate of cumulative device- or procedure-related SAEs through 5 years was 19.9% with only 9.3% of those occurring after the first year. No stent fractures were observed through 5 years by x-ray evaluation. Conclusion: The 5-year safety and efficacy outcomes of the endoprosthesis were clinically acceptable for treating complex FP lesions in a real-world cohort of Japanese patients with PAD. (ClinicalTrials.gov Identifier: NCT04706273).
Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Arteria Femoral , Enfermedad Arterial Periférica , Arteria Poplítea , Vigilancia de Productos Comercializados , Diseño de Prótesis , Stents , Grado de Desobstrucción Vascular , Humanos , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/cirugía , Masculino , Anciano , Femenino , Arteria Poplítea/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Arteria Femoral/fisiopatología , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Japón , Estudios Prospectivos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Persona de Mediana Edad , Pueblos del Este de AsiaRESUMEN
INTRODUCTION: Although favorable results of fluoropolymer-based drug-eluting stent (FP-DES) treatment for femoropopliteal lesions have been reported, it is unclear whether minimal lumen area (MLA) after FP-DES implantation affects clinical outcomes. This study aimed to reveal the association between intravascular ultrasound (IVUS)-evaluated MLA and the 1-year risk of restenosis and aneurysmal degeneration after FP-DES implantation for femoropopliteal lesions. METHODS: A subanalysis of the CAPSICUM (Contemporary outcomes After Paclitaxel-eluting peripheral Stent implantation for symptomatic lower limb IsChemia with sUperficial feMoral or proximal popliteal lesion) study analyzed 718 limbs in 686 patients with available IVUS-evaluated MLA data. The association of MLA with the 1-year risk of restenosis and aneurysmal degeneration was analyzed using the generalized propensity score method. RESULTS: The 1-year incidence rate of restenosis was estimated to be 8.8% (95% CI, 6.1% to 12.5%) for the upper quartile of MLA (21.1 mm2) versus 14.3% (95% CI, 10.7% to 18.7%) for the lower quartile of MLA (15.2 mm2), with an odds ratio of 0.58 (95% CI, 0.36 to 0.93; p = 0.024), whereas the 1-year incidence rate of aneurysmal degeneration was 23.8% (95% CI, 19.5% to 28.8%) for the upper quartile versus 16.8% (95% CI, 12.6% to 22.0%) for the lower quartile, with an odds ratio of 1.55 (95% CI, 1.04 to 2.32; p = 0.031). CONCLUSION: A large MLA after FP-DES implantation for femoropopliteal lesions was associated with decreased restenosis risk but increased aneurysmal degeneration risk. These findings suggest that MLA is a valuable predictor of clinical outcomes.
Asunto(s)
Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Resultado del Tratamiento , Paclitaxel/efectos adversos , Constricción Patológica , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Grado de Desobstrucción VascularRESUMEN
Efficacy of percutaneous deep venous arterialization (pDVA) has been reported for patients with no-option chronic limb-threatening ischemia (CLTI). In the countries where a manufactured device dedicated for pDVA has not been reimbursed, pDVA using the off-the-shelf technique has alternatively spread. The off-the-shelf techniques for arteriovenous fistula (AVF) creation reported are as follows: AV spear technique, venous arterialization simplified technique (VAST), and a use of penetration guidewire or a reentry device. Technical success rates of the procedures are similar to those using the dedicated device. pDVA could be a last resort for the patients with no-option CLTI, including those suffering from stump ulcer after major limb amputation or those with occluded surgical bypass.
RESUMEN
OBJECTIVE: Surgical thromboendarterectomy (TEA) is the standard treatment for an occlusive lesion of the common femoral artery (CFA). However, there is limited knowledge on the need for patch angioplasty in CFA TEA. The objective of this study was to compare the peri-operative and two year results of CFA TEA with or without patch angioplasty. METHODS: A multicentre retrospective observational study was performed at 34 Japanese centres. Comparisons were made between patients undergoing CFA TEA with or without patch angioplasty after propensity score matching (PSM). The primary endpoints were primary patency and freedom from target lesion revascularisation (TLR) of the TEA lesion. The secondary endpoints were hospital outcomes, limb salvage, and overall survival. RESULTS: Between 2018 and 2020, 428 TEA procedures (237 with patch angioplasty and 191 with primary closure) were performed. PSM extracted 151 pairs with no significant intergroup differences in baseline characteristics. Peri-operative death and complications occurred in 0.7% vs. 1.3% (p = 1.0) and 6.0% vs. 6.6% (p = 1.0), respectively. The follow up rate was 96% over a median follow up of 14.9 months (interquartile range 8.3, 24.3). Loss of primary patency occurred in 18 patients. The two year primary patency of patch angioplasty cases was statistically significantly higher than that of primary closure cases (97.0% vs. 89.9%; p = .021). TLR was performed in 14 patients. The two year freedom from TLR in patch angioplasty cases was also statistically significantly higher than in primary closure cases (98.6% vs. 92.9%; p = .003). During follow up, seven limbs required major amputation and 40 patients died. There was no statistically significant difference in limb salvage and survival between the two groups after PSM. CONCLUSIONS: This is the first report to show that patch angioplasty may decrease re-stenosis and target lesion revascularisation of CFA TEA lesions.
Asunto(s)
Angioplastia de Balón , Endarterectomía , Humanos , Endarterectomía/efectos adversos , Endarterectomía/métodos , Angioplastia/efectos adversos , Procedimientos Quirúrgicos Vasculares , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Recuperación del Miembro , Estudios Retrospectivos , Grado de Desobstrucción Vascular , Angioplastia de Balón/efectos adversos , Resultado del TratamientoRESUMEN
AIM: The present study investigated the effects of additional cilostazol administration on the 12-month risk of restenosis after femoropopliteal heparin-bonded stent graft implantation. METHODS: This study was a sub-analysis of the Viabahn stent graft placement for femoropopliteal disease reQUIring endovaScular tHerapy (VANQUISH) study, which was a prospective multicenter study investigating patients who received Viabahn stent graft (W.L. Gore & Associates, Flagstaff, AZ, USA) and dual-antiplatelet therapy with aspirin and a thienopyridine. The comparison of clinical outcomes between subgroups with and without cilostazol treatment were performed using the propensity score-matching method to minimize the intergroup differences in baseline characteristics. RESULTS: Cilostazol-treated patients had a lower 12-month proportion of restenosis than cilostazol-free patients (8.2% vs 27.3%). The odds ratio of cilostazol for the 12-month restenosis was 0.27 [95% CI, 0.08 to 0.97] (p=0.045). Furthermore, the cumulative incidence rates of surgical reconstruction, target lesion revascularization and acute thrombotic occlusion (p values by the log-rank test) were 2.6% versus 1.8% (P=0.43), 5.3% versus 20.5% (P=0.067), and 0.0% versus 11.8% (P=0.0499), respectively. The rates of surgical reconstruction and target lesion revascularization (TLR) were not significantly different between both groups. CONCLUSIONS: Our study revealed the clinical impact of additional cilostazol treatment on the risk of restenosis and acute thrombotic occlusion following heparin-bonded stent graft implantation, while TLR and surgical reconstruction were not significantly different.
RESUMEN
OBJECTIVE: To compare the results of endovascular treatment with drug-eluting stents (DES) and drug-coated balloons (DCB) in atherosclerotic lesions in the femoropopliteal artery, as well as to assess restenotic patterns. METHODS: Clinical data from 617 cases treated with DES or DCB for femoropopliteal diseases were analyzed in this multicenter, retrospective cohort study. From these, 290 DES and 145 DCB cases were extracted by propensity score matching. Outcomes investigated were 1- and 2-year primary patency, reintervention, and restenotic pattern and its impact on symptoms in each group. RESULTS: The primary patency rates at 1 and 2 years in the DES group were superior to those in the DCB group (84.8% and 71.1% vs 81.3% and 66.6%, P = .043), whereas there was no significant difference in freedom from target lesion revascularization (91.6% and 82.6% vs 88.3% and 78.8%, P = .13). Compared with what was measured before the index procedures, exacerbated symptoms, rate of occlusion, and an increase in the occluded length at loss of patency were more frequent in the DES group than in the DCB group. The odds ratios were 3.53 (95% confidence interval, 1.31-9.49; P = .012), 3.61 (1.09-11.9; P = .036), and 3.82 (1.15-12.7; P = .029), respectively. On the other hand, the frequency of an increase in lesion length and requirement of target lesion revascularization were similar between the two groups. CONCLUSIONS: Primary patency was significantly higher at 1 and 2 years in the DES than in the DCB group. However, DES were associated with exacerbated clinical symptoms and complicated lesion characteristics at the point of loss of patency.
Asunto(s)
Angioplastia de Balón , Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Humanos , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Angioplastia de Balón/efectos adversos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Materiales Biocompatibles Revestidos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapiaRESUMEN
PURPOSE: To compare the 3-year clinical outcomes of endoluminal bypass with those of surgical bypass for complex femoropopliteal (FP) arterial lesions. MATERIALS AND METHODS: In this retrospective multicenter study, 530 patients with symptomatic peripheral artery disease (Rutherford classification 1-3, 66.0%; 4-6, 34.0%) who underwent either endoluminal bypass with Viabahn stent grafts (n = 276) or surgical bypass (n = 254) (with saphenous vein grafts, 74.4%; prosthetic grafts, 25.6%) for FP arterial lesions between 2010 and 2018 were analyzed. The propensity score-matched analysis was performed to compare the 3-year clinical outcomes of endoluminal bypass with those of surgical bypass. The primary end point was primary patency (freedom from restenosis). The secondary end points were secondary patency, freedom from target lesion revascularization (TLR), limb salvage, and overall survival. The interaction effect of baseline characteristics on the association of the revascularization strategy with the risk of restenosis was analyzed using the Poisson mixed-effect model. RESULTS: The propensity score-matched analysis extracted 107 pairs. After propensity score matching, the primary patency rate at 1, 2, and 3 years was 84.5%, 75.1%, and 70.9%, respectively, for the endoluminal bypass group versus 78.6%, 73.3%, and 72.0%, respectively, for the surgical bypass group (P = .65). There was no significant difference in secondary patency, freedom from TLR, limb salvage, and overall survival (all P > .05). The subsequent interaction analysis revealed that the involvement of popliteal lesions, small distal reference vessel diameters, and long lesions favored surgical bypass over endoluminal bypass because of improved primary patency (all P for interaction < .05). CONCLUSIONS: The 3-year clinical outcomes after endoluminal bypass or surgical bypass for FP arterial lesions were similar.
Asunto(s)
Implantación de Prótesis Vascular , Enfermedad Arterial Periférica , Humanos , Prótesis Vascular , Grado de Desobstrucción Vascular , Resultado del Tratamiento , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Estudios Retrospectivos , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Recuperación del MiembroRESUMEN
PURPOSE: To evaluate the efficacy of the Active Seal technology employed in the AFX endovascular aortic aneurysm system (AFX), during endovascular aneurysm repair (EVAR) in patients with abdominal aortic aneurysms (AAAs) having a conical proximal neck. MATERIALS AND METHODS: A retrospective analysis of the EVAR for AAA with a conical proximal neck using the AFX was performed at 17 Japanese hospitals between January 2016 and August 2020. The conical proximal neck was defined as a cone-shaped proximal neck, with more than 10% diameter increase within a 15 mm length at the proximal landing zone. All anatomical analyses were performed in the core laboratory, and cases with parallel walls within the proximal neck adequate for the landing zone were excluded from the study. RESULTS: This study included 53 patients, but only 39 patients (mean age, 76.6 ± 6.7 years; 87.0% males; mean aneurysm diameter, 52.0 ± 8.0 mm) were analyzed after being characterized as having a pure conical neck by the core laboratory. The mean proximal neck diameters at the lower renal artery and proximal edge of the aneurysm were 20.0 ± 2.9 mm and 27.5 ± 4.9 mm, respectively. The mean proximal neck length was 21.5 ± 6.0 mm. Instructions for use violations other than the conical neck were observed in 15 patients (38.5%). The VELA cuff was used in all cases; however, additional proximal cuff was required in 9 more cases (23.1%). The Active Seal technology was able to significantly extend the proximal sealing zone from 21.5 ± 6.0 to 26.0 ± 12.2 mm (p = .047). Thirty-six patients completed the 12-month follow-up (one patient was lost to follow-up, and 2 patients died from causes unrelated to the aneurysm), and there were no type-1a and 3 endoleaks with only one reintervention (2.6%) related to type 1b endoleak in the 12-month period. Furthermore, there was no significant enlargement of the proximal neck diameter at 12 months (at 1 month: 20.6 ± 3.4 mm and at 12 months: 21.3 ± 3.8 mm; p = .420). CONCLUSION: The Active Seal technology of the AFX significantly extended the proximal seal zone and no type-1a endoleak and proximal neck dilation was observed in patients with conical proximal neck at 12 months.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Stents/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Diseño de Prótesis , Procedimientos Endovasculares/efectos adversos , Factores de RiesgoRESUMEN
PURPOSE: This study retrospectively evaluated the 12-month outcomes of the Zenith Alpha Abdominal Endovascular graft (Zenith Alpha AAA, Cook, Inc, Bloomington, Indiana), which was launched partially in Japan in March 2019, starting with 9 selected sites. METHODS: A retrospective analysis was performed of all endovascular aneurysm repairs (EVAR) for abdominal aortic aneurysms using the Zenith Alpha AAA. Late complications were defined as any aneurysm-related events occurring >30 days after EVAR, including an aneurysm sac enlargement of >5 mm and any reinterventions performed. Endoleaks without sac enlargement or reinterventions were excluded from late complications. RESULTS: During the study period, 79 EVARs using the Zenith Alpha AAA were performed. The mean age was 76.6±6.9 years old, 91.1% of patients were male, and the mean aneurysm diameter was 51.1±7.5 mm. Instructions for use violation was observed in 27 patients (34.2%), most frequently being a severely angulated proximal neck (>60°). There were 4 intraoperative complications, including 2 unintentional partial renal artery coverages caused by the premature anchoring of the exposed suprarenal stent barb to the aortic wall, which was a result of the design change of the top cap deletion. Since it was a partial coverage without flow impairment and since renal stenting was unsuccessful, it was left untreated and had no subsequent renal function impairment. During the mean follow-up of 444±123 days, 74 patients completed 12 months of follow-up. Freedom from late complications at 12 months was 90.8%, which included 2 limb occlusions (2.5%). Of 71 patients with a 12-month computed tomography scan, there was only 1 type 1a endoleak (1.3%), 1 sac enlargement of >5 mm (1.3%), and an aneurysm sac shrinkage of >5 mm was observed in 42.2% of patients. There was no type 3 endoleak during the follow-up. CONCLUSIONS: This study demonstrated that the new generation of low-profile Zenith Alpha AAA has satisfactory early clinical outcomes, comparable to those obtained with the conventional Zenith endovascular graft. Long-term follow-up is needed to determine whether these favorable outcomes persist.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Endofuga/diagnóstico por imagen , Endofuga/etiología , Resultado del Tratamiento , Japón , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodosRESUMEN
OBJECTIVE: The objective of this study was to investigate the mid-term outcomes of embolization procedures for type II endoleak after endovascular abdominal aortic repair, and clarify the risk factors for aneurysm enlargement after embolization procedures. METHODS: This was a retrospective multicenter registry study enrolling patients who underwent embolization procedures for type II endoleaks after EVAR from January 2012 to December 2018 at 19 Japanese centers. The primary end point was the rate of freedom from aneurysm enlargement, more than 5 mm in the aortic maximum diameter, after an embolization procedure. Demographic, procedural, follow-up, and laboratory data were collected. Continuous variables were summarized descriptively, and Kaplan-Meier analyses and a Cox regression model were used for statistical analyses. RESULTS: A total of 315 patients (248 men and 67 women) were enrolled. The average duration from the initial embolization procedure to the last follow-up was 31.6 ± 24.6 months. The rates of freedom from aneurysm enlargement at 3 and 5 years were 55.4 ± 3.8% and 37.0 ± 5.2%, respectively. A multivariate analysis revealed that a larger aortic diameter at the initial embolization procedure and the presence of a Moyamoya endoleak, defined as heterogeneous contrast opacity with an indistinct faint border, were associated with aneurysm enlargement after embolization management. CONCLUSIONS: The embolization procedures were generally ineffective in preventing further expansion of abdominal aortic aneurysms in patients with type II endoleaks after EVAR, especially in patients with a large abdominal aortic aneurysm and/or a presence of a Moyamoya endoleak.