Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 96(28): 11549-11556, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-38958207

RESUMEN

Human-borne acetone is a potent marker of lipid metabolism. Here, an enzyme immobilization method for secondary alcohol dehydrogenase (S-ADH), which is suitable for highly sensitive and selective biosensing of acetone, was developed, and then its applicability was demonstrated for spatiotemporal imaging of concentration distribution. After various investigations, S-ADH-immobilized meshes could be prepared with less than 5% variation by cross-linking S-ADH with glutaraldehyde on a cotton mesh at 40 °C for 15 min. Furthermore, high activity was obtained by adjusting the concentration of the coenzyme nicotinamide adenine dinucleotide (NADH) solution added to the S-ADH-immobilized mesh to 500 µM and the solvent to a potassium phosphate buffer solution at pH 6.5. The gas imaging system using the S-ADH-immobilized mesh was able to image the decrease in NADH fluorescence (ex 340 nm, fl 490 nm) caused by the catalytic reaction of S-ADH and the acetone distribution in the concentration range of 0.1-10 ppm-v, including the breath concentration of healthy people at rest. The exhaled breath of two healthy subjects at 6 h of fasting was quantified as 377 and 673 ppb-v, which were consistent with the values quantified by gas chromatography-mass spectrometry.


Asunto(s)
Acetona , Pruebas Respiratorias , Enzimas Inmovilizadas , Acetona/análisis , Acetona/química , Humanos , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Técnicas Biosensibles , Oxidorreductasas de Alcohol/química , Oxidorreductasas de Alcohol/metabolismo , Gases/química , Gases/análisis , Espiración , NAD/análisis , NAD/química , NAD/metabolismo
2.
ACS Sens ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38919035

RESUMEN

Fruits can emit ethanol, which is generated through fermentation during hypoxic storage. We imaged spatiotemporal changes in the gaseous ethanol emitted by "La France" pear via its epicarp. The gas-imaging system utilized enzymes to transduce the ethanol concentration into fluorescence intensity. Initially, the uniformity of the enzyme and coenzyme distribution was evaluated to validate the imaging capability. Subsequently, two surface-fitting methods were compared to accurately image ethanol emitted from three-dimensional (3D) objects with a double-curved surface. The imaging results of ethanol emitted from the pear indicated that the distribution of ethanol was related to lenticels, which have been reported to possess high ethanol diffusivity, on the epicarp. As quantified by the system (uniformity of coenzyme and enzymes was 93.2 and 98.8%, respectively; dynamic range was 0.01-100 ppm), ethanol concentration increased with the storage period under hypoxic conditions (0.4-5.3 ppm, from day 1 to 10). The system enables the observation of the location, quantity, and temporal pattern of ethanol release from fruit, which could be a useful technology for agricultural applications.

3.
Sensors (Basel) ; 24(5)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38474972

RESUMEN

Salivary turbidity is a promising indicator for evaluating oral hygiene. This study proposed a wearable mouthguard-type sensor for continuous and unconstrained measurement of salivary turbidity. The sensor evaluated turbidity by measuring the light transmittance of saliva with an LED and a phototransistor sealed inside a double-layered mouthguard. The sensor was also embedded with a Bluetooth wireless module, enabling the wireless measurement of turbidity. The mouthguard materials (polyethylene terephthalate-glycol and ethylene-vinyl acetate) and the wavelength of the LED (405 nm) were experimentally determined to achieve high sensitivity in salivary turbidity measurement. The turbidity quantification characteristic of the proposed sensor was evaluated using a turbidity standard solution, and the sensor was capable of turbidity quantification over a wide dynamic range of 1-4000 FTU (formazine turbidity unit), including reported salivary turbidity (400-800 FTU). In vitro turbidity measurement using a saliva sample showed 553 FTU, which is equivalent to the same sample measured with a spectrophotometer (576 FTU). Moreover, in vivo experiments also showed results equivalent to that measured with a spectrophotometer, and wireless measurement of salivary turbidity was realized using the mouthguard-type sensor. Based on these results, the proposed mouthguard-type sensor has promising potential for the unconstrained continuous evaluation of oral hygiene.


Asunto(s)
Protectores Bucales , Dispositivos Electrónicos Vestibles , Higiene Bucal , Saliva
4.
Sensors (Basel) ; 23(13)2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37447706

RESUMEN

The molecule 2-nonenal is renowned as the origin of unpleasant human aging-related body odor that can potentially indicate age-related metabolic changes. Most 2-nonenal measurements rely on chromatographic analytical systems, which pose challenges in terms of daily usage and the ability to track changes in concentration over time. In this study, we have developed liquid- and gas-phase biosensors (bio-sniffers) with the aim of enabling facile and continuous measurement of trans-2-nonenal vapor. Initially, we compared two types of nicotinamide adenine dinucleotide (phosphate) [NAD(P)]-dependent enzymes that have the catalytic ability of trans-2-nonenal: aldehyde dehydrogenase (ALDH) and enone reductase 1 (ER1). The developed sensor quantified the trans-2-nonanal concentration by measuring fluorescence (excitation: 340 nm, emission: 490 nm) emitted from NAD(P)H that was generated or consumed by ALDH or ER1. The ALDH biosensor reacted to a variety of aldehydes including trans-2-nonenal, whereas the ER1 biosensor showed high selectivity. In contrast, the ALDH bio-sniffer showed quantitative characteristics for trans-2-nonenal vapor at a concentration range of 0.4-7.5 ppm (with a theoretical limit of detection (LOD) and limit of quantification (LOQ) of 0.23 and 0.26 ppm, respectively), including a reported concentration (0.85-4.35 ppm), whereas the ER1 bio-sniffer detected only 0.4 and 0.8 ppm. Based on these findings, headspace gas of skin-wiped alcohol-absorbed cotton collected from study participants in their 20s and 50s was measured by the ALDH bio-sniffer. Consequently, age-related differences in signals were observed, suggesting the potential for measuring trans-2-nonenal vapor.


Asunto(s)
Técnicas Biosensibles , NAD , Humanos , Olor Corporal , Aldehídos , Técnicas Biosensibles/métodos , Envejecimiento
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 1298-1301, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946130

RESUMEN

Mouthguard type sensors have been developed to monitor the healthcare-related information, which is expected to be used for pre-illness and preventive medicine. However, a method for supplying the power to these sensors is still an issue to be solved. In this paper, we propose an electrostatic oral cavity generator driven by occlusal force to supply the power for mouthguard type sensors. The proposed generator is a sheet form and consists of the lamination of the electret, dielectric elastomer and copper electrode. In this paper, we estimated the power generation with a piezoelectric generator and the proposed electrostatic generator. Then, the generators were designed and fabricated. The generated power of the prototype electrostatic generator was 18.0 µW. It was about 560 times larger than that of a piezoelectric generator with the area equivalent to four pairs of molars. Although the generated power was still smaller than the required power to drive the mouthguard sensor, we considered they can be comparable with each other by optimizing the design parameters of the generator.


Asunto(s)
Fuentes de Energía Bioeléctrica , Fuerza de la Mordida , Protectores Bucales , Boca , Electrodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...