Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
EJNMMI Rep ; 8(1): 6, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748042

RESUMEN

PURPOSE: To determine the efficacy and safety of target volume determination by 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) for intensity-modulated radiation therapy (IMRT) for locally advanced head and neck squamous cell carcinoma (HNSCC) extending into the oral cavity or oropharynx. METHODS: We prospectively treated 10 consecutive consenting patients with HNSCC using IMRT, with target volumes determined by PET-CT. Gross tumor volume (GTV) and clinical target volume (CTV) at the oral level were determined by two radiation oncologists for CT, magnetic resonance imaging (MRI), and PET-CT. Differences in target volume (GTVPET, GTVCT, GTVMRI, CTVPET, CTVCT, and CTVMRI) for each modality and the interobserver variability of the target volume were evaluated using the Dice similarity coefficient and Hausdorff distance. Clinical outcomes, including acute adverse events (AEs) and local control were evaluated. RESULTS: The mean GTV was smallest for GTVPET, followed by GTVCT and GTVMRI. There was a significant difference between GTVPET and GTVMRI, but not between the other two groups. The interobserver variability of target volume with PET-CT was significantly less than that with CT or MRI for GTV and tended to be less for CTV, but there was no significant difference in CTV between the modalities. Grade ≤ 3 acute dermatitis, mucositis, and dysphagia occurred in 55%, 88%, and 22% of patients, respectively, but no grade 4 AEs were observed. There was no local recurrence at the oral level after a median follow-up period of 37 months (range, 15-55 months). CONCLUSIONS: The results suggest that the target volume determined by PET-CT could safely reduce GTV size and interobserver variability in patients with locally advanced HNSCC extending into the oral cavity or oropharynx undergoing IMRT. Trial registration UMIN, UMIN000033007. Registered 16 jun 2018, https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000037631.

2.
Sci Rep ; 14(1): 11253, 2024 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755333

RESUMEN

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Litio , Neutrones , Terapia por Captura de Neutrón de Boro/métodos , Litio/química , Humanos , Aceleradores de Partículas , Dosificación Radioterapéutica
3.
Asian J Urol ; 11(2): 286-293, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38680582

RESUMEN

Objectives: Hydrogel spacer (HS) was developed to reduce rectal toxicities caused by radiotherapy, but has been reported to cause major adverse events. Our institute has attempted to introduce a hyaluronic acid (HA) as an alternative spacer. This study aimed to compare rectal doses and geometric distributions between the HS and HA implantation in prostate cancer. Methods: HS and HA were inserted in 20 and 18 patients undergoing high-dose brachytherapy, respectively. The rectum spacer volumes injected were 10 mL and 22 mL, respectively. In the treatment planning system, 13.5 Gy was administered with common catheter positions. The rectal dose indices were assessed between the spacer groups for dosimetry evaluation. Distances between the prostate and rectum and configurations of the spacers were compared. Results: The mean doses irradiated to 0.1 and 2 mL of the rectum were 10.45 Gy and 6.71 Gy for HS, and 6.73 Gy and 4.90 Gy for HA (p<0.001). The mean minimum distances between the prostate and rectum were 1.23 cm and 1.79 cm for HS and HA, respectively (p<0.05). Geometrical configuration comparisons revealed that HA has a higher ability to expand the space than HS. Conclusion: The rectal dose reduction ability of HA is significantly greater than that of HS, suggesting its potential as a new spacer.

4.
J Radiat Res ; 65(3): 323-327, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38544297

RESUMEN

This study assessed the significance of hands-on-training (HoT) and questionnaire-based surveys on 3D image-guided brachytherapy (3D-IGBT) and a combination of intracavitary and interstitial brachytherapy, the so-called 'hybrid' BT (HBT), in uterine cervical cancer. In October 2023, 29 radiation oncologists, nurses, radiologic technologists and medical physicists from 10 Japanese facilities participated in an HoT on 3D-IGBT and HBT. Questionnaires were distributed to each participant before and after the HoT, and feedback was obtained through online channels. The questionnaire response rate was 83% (24/29), with at least one participant responding from each facility. 'Insertion of applicators and needles', 'human resource shortage' and 'pain relief and sedation' were the primary concerns of radiation oncologists. 'Applicator reconstruction', ' optimization of dwell positions', ' treatment planning' and ' human resource shortages ' were the primary concerns of radiological technologists and medical physicists. The HoT content was adjusted according to the results of preliminary surveys. The concerns expressed by the participants were addressed during the lectures and practical training. Significant reductions in anxiety were observed toward all items of the 10-point self-assessment after the HoT, regardless of the profession. The average score on satisfaction with the HoT (on a 10-point scale) was 9.52 (minimum of 8 and maximum of 10). In conclusion, HoT tailored in response to a pre-questionnaire-based survey effectively reduced participants' anxiety regarding the implementation of 3D-IGBT and HBT.


Asunto(s)
Ansiedad , Braquiterapia , Radioterapia Guiada por Imagen , Humanos , Encuestas y Cuestionarios , Femenino , Neoplasias del Cuello Uterino/radioterapia
5.
J Appl Clin Med Phys ; 25(5): e14305, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38368607

RESUMEN

PURPOSE: To elucidate the dosimetric errors caused by a model-based algorithm in lung stereotactic body radiation therapy (SBRT) with Helical TomoTherapy (HT) using Monte Carlo (MC)-based dose verification software. METHODS: For 38 plans of lung SBRT, the dose calculation accuracy of a treatment planning system (TPS) of HT was compared with the results of DoseCHECK, the commercial MC-based independent verification software. The following indices were extracted to evaluate the correlation of dosimetric errors: (1) target volume, (2) average computed tomography (CT) value of the planning target volume (PTV) margin, and (3) average CT value of surrounding 2-mm area of the PTV (PTV ring). Receiver operating characteristic (ROC) analyses determined the threshold for 5% of differences in PTV D95%. Then, the 38 plans were classified into two groups using the cutoff values of ROC analysis for these three indices. Dosimetric differences between groups were statistically compared using the Mann-Whitney U test. RESULTS: TPS of HT overestimated by more than 5% in the PTV D95% in 16 of 38 plans. The PTV ring showed the strongest correlation with dosimetric differences. The cutoff value for the target volume, the PTV margin, and the PTV ring was 14.7 cc, -754 HU, and -708 HU, respectively. The area under the curve (AUC) for the target volume, the PTV margin, and the PTV ring were 0.835, 0.878, and 0.932, respectively. Dosimetric errors more than 5% were observed when the PTV volume was less than 15 cc or when the CT value around the target was less than -700 HU. CONCLUSION: The TPS of HT might overestimate the PTV dose by more than 5% if any the three indices in this study were below threshold. Therefore, independent verification with an MC-based algorithm should be strongly recommended for lung SBRT in HT.


Asunto(s)
Algoritmos , Neoplasias Pulmonares , Método de Montecarlo , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Programas Informáticos , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Radiocirugia/métodos , Órganos en Riesgo/efectos de la radiación , Radiometría/métodos
6.
Med Dosim ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38368182

RESUMEN

Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.

7.
Surg Case Rep ; 9(1): 192, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37907692

RESUMEN

BACKGROUND: IgG4-related diseases are characterized by marked infiltration and IgG4-positive plasma cells and fibrosis, and involve multiple organs. However, IgG4-related mastitis is rare. We report a case of mastitis associated with IgG4-related disease. CASE PRESENTATION: A 78-year-old woman visited our hospital with a complaint of multiple subcutaneous nodules. A biopsy of a dorsal subcutaneous mass was performed but did not yield a definitive diagnosis. However, blood tests showed a high level of IgG4, thus she was referred to the department of collagen disease for further examination. Computed tomography (CT) showed a thickening of the skin of the right breast, and the patient was referred to our department. On physical examination, a large area of thickened skin was observed in the right breast without inflammatory breast cancer-like redness, and no mass was palpable. A needle biopsy was performed on an indistinct hypoechoic area in the breast, and she was diagnosed with mastitis associated with IgG4-related disease. Systemic steroid therapy was then administered and the symptoms of multiple skin nodules and mastitis improved. CONCLUSIONS: We reached the diagnosis based on a biopsy of the mammary gland enabling the patient to begin treatment for IgG4-related disease. This case was characterized by breast skin thickening, which is different from inflammatory breast cancer.

8.
Front Oncol ; 13: 1272507, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37901311

RESUMEN

This study reports the first patient treatment for cutaneous malignant melanoma using a linear accelerator-based boron neutron capture therapy (BNCT) system. A single-center open-label phase I clinical trial had been conducted using the system since November 2019. A patient with a localized node-negative acral malignant melanoma and the largest diameter of the tumor ≤ 15 cm who refused primary surgery and chemotherapy was enrolled. After administering boronophenylalanine (BPA), a single treatment of BNCT with the maximum dose of 18 Gy-Eq delivered to the skin was performed. The safety and efficacy of the accelerator-based BNCT system for treating localized cutaneous malignant melanoma were evaluated. The first patient with cutaneous malignant melanoma in situ on the second finger of the left hand did not develop dose-limiting toxicity in the clinical trial. After BNCT, the treatment efficacy was gradually observed, and the patient achieved PR within 6 months and CR within 12 months. Moreover, during the follow-up period of 12 months after BNCT, the patient did not exhibit a recurrence without any treatment-related grade 2 or higher adverse events. Although grade 1 adverse events of dermatitis, dry skin, skin hyperpigmentation, edema, nausea, and aching pain were noted in the patient, those adverse events were relieved without any treatment. This case report shows that the accelerator-based BNCT may become a promising treatment modality for cutaneous malignant melanoma. We expect further clinical trials to reveal the efficacy and safety of the accelerator-based BNCT for cutaneous malignant melanoma.

9.
J Radiat Res ; 64(4): 661-667, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37295954

RESUMEN

This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neutrones Rápidos , Litio , Neutrones , Aceleradores de Partículas , Efectividad Biológica Relativa
10.
J Clin Oncol ; 41(18): 3329-3338, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37079878

RESUMEN

PURPOSE: Treatment with an aromatase inhibitor for 5 years is the standard treatment for postmenopausal hormone receptor-positive breast cancer. We investigated the effects of extending this treatment to 10 years on disease-free survival (DFS). PATIENTS AND METHODS: This prospective, randomized, multicenter open-label phase III study assessed the effect of extending anastrozole treatment for an additional 5 years in postmenopausal patients who were disease-free after treatment with either 5 years of anastrozole alone or 2-3 years of tamoxifen followed by 2-3 years of anastrozole. Patients were allocated randomly (1:1) to continue anastrozole for an additional 5 years or stop anastrozole. The primary end point was DFS, including breast cancer recurrence, second primary cancers, and death from any cause. This study is registered with University Hospital Medical Information Network, Japan (UMIN) clinical trials registry (UMIN000000818). RESULTS: We enrolled 1,697 patients from 117 facilities between November 2007 and November 2012. Follow-up information was available for 1,593 patients (n = 787 in the continue group, n = 806 in the stop group), who were defined as the full analysis set, including 144 patients previously treated with tamoxifen and 259 patients who underwent breast-conserving surgery without irradiation. The 5-year DFS rates were 91% (95% CI, 89 to 93) in the continue group and 86% (95% CI, 83 to 88) in the stop group (hazard ratio, 0.61; 95% CI, 0.46 to 0.82; P < .0010). Notably, extended anastrozole treatment reduced the incidence of local recurrence (continue group, n = 10; stop group, n = 27) and second primary cancers (continue group, n = 27; stop group, n = 52). There was no significant difference in overall or distant DFS. Menopausal or bone-related all-grade adverse events were more frequent among patients in the continue group than those in the stop group, but the incidence of grade ≥3 adverse events was <1% in both groups. CONCLUSION: Continuing adjuvant anastrozole for an additional 5 years after 5 years of initial treatment with anastrozole or tamoxifen followed by anastrozole was well tolerated and improved DFS. Although no difference in overall survival was observed as in other trials, extended anastrozole therapy could be one treatment choice in postmenopausal patients with hormone receptor-positive breast cancer.


Asunto(s)
Neoplasias de la Mama , Neoplasias Primarias Secundarias , Humanos , Femenino , Anastrozol/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/cirugía , Estudios Prospectivos , Neoplasias Primarias Secundarias/inducido químicamente , Nitrilos/efectos adversos , Triazoles/efectos adversos , Recurrencia Local de Neoplasia/tratamiento farmacológico , Tamoxifeno/efectos adversos , Inhibidores de la Aromatasa/efectos adversos , Supervivencia sin Enfermedad , Adyuvantes Inmunológicos/uso terapéutico , Antineoplásicos Hormonales/efectos adversos , Quimioterapia Adyuvante
11.
J Appl Clin Med Phys ; 24(5): e13915, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36934441

RESUMEN

PURPOSE: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance-guided radiotherapy (MRgRT) system. METHOD: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in-house-developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results. RESULTS: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam-hold and beam-on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively. CONCLUSIONS: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Humanos , Movimiento (Física) , Espectroscopía de Resonancia Magnética , Dosificación Radioterapéutica , Fantasmas de Imagen
12.
Jpn J Clin Oncol ; 53(6): 508-513, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36810684

RESUMEN

OBJECTIVE: Compared with the implementation speed of image-guided adaptive brachytherapy for uterine cervical cancer, that of intracavitary and interstitial brachytherapy is slow, possible because it requires more invasive procedure of inserting needles directly into tumours. To accelerate the implementation speed of intracavitary and interstitial brachytherapy, a first hands-on seminar for image-guided adaptive brachytherapy and intracavitary and interstitial brachytherapy for uterine cervical cancer was held on 26 November 2022, supported by Japanese Society for Radiology and Oncology. This article deals with this hands-on seminar and difference of degree of confidence of participants in starting intracavitary and interstitial brachytherapy before and after the seminar. METHODS: The seminar consisted of lectures regarding intracavitary and interstitial brachytherapy in the morning and hands-on practice of needle insertion and contouring, as well as dose calculation practice using the radiation treatment system in the evening. Prior to and following the seminar, participants completed a questionnaire asking about their level of confidence in performing intracavitary and interstitial brachytherapy, expressed between 0 and 10 (the higher the number, the stronger the confidence). RESULTS: A total of 15 physicians, six medical physicists and eight radiation technologists from 11 institutions attended the meeting. The median level of confidence before and after the seminar was 3 (range, 0-6) and 5.5 (range, 3-7), respectively, and a statistically significant improvement was observed (P<0.001). CONCLUSION: It was suggested that the hands-on seminar on intracavitary and interstitial brachytherapy for locally advanced uterine cervical cancer improved the level of confidence of the attendees and propelled their motivation, through which it is expected that the implementation of intracavitary and interstitial brachytherapy will be accelerated.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Femenino , Humanos , Dosificación Radioterapéutica , Braquiterapia/métodos , Neoplasias del Cuello Uterino/patología , Planificación de la Radioterapia Asistida por Computador/métodos
13.
Med Phys ; 50(1): 424-439, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36412161

RESUMEN

BACKGROUND: Boron Neutron Capture Therapy (BNCT) has recently been used in clinical oncology thanks to recent developments of accelerator-based BNCT systems. Although there are some specific processes for BNCT, they have not yet been discussed in detail. PURPOSE: The aim of this study is to provide comprehensive data on the risk of accelerator-based BNCT system to institutions planning to implement an accelerator-based BNCT system. METHODS: In this study, failure mode and effects analysis (FMEA) was performed based on a treatment process map prepared for the accelerator-based BNCT system. A multidisciplinary team consisting of a medical doctor (MD), a registered nurse (RN), two medical physicists (MP), and three radiologic technologists (RT) identified the failure modes (FMs). Occurrence (O), severity (S), and detectability (D) were scored on a scale of 10, respectively. For each failure mode (FM), risk priority number (RPN) was calculated by multiplying the values of O, S, and D, and it was then categorized as high risk, very high risk, and other. Additionally, FMs were statistically compared in terms of countermeasures, associated occupations, and whether or not they were the patient-derived. RESULTS: The identified FMs for BNCT were 165 in which 30 and 17 FMs were classified as high risk and very high risk, respectively. Additionally, 71 FMs were accelerator-based BNCT-specific FMs in which 18 and 5 FMs were classified as high risk and very high risk, respectively. The FMs for which countermeasures were "Education" or "Confirmation" were statistically significantly higher for S than the others (p = 0.019). As the number of BNCT facilities is expected to increase, staff education is even more important. Comparing patient-derived and other FMs, O tended to be higher in patient-derived FMs. This could be because the non-patient-derived FMs included events that could be controlled by software, whereas the patient-derived FMs were impossible to prevent and might also depend on the patient's condition. Alternatively, there were non-patient-derived FMs with higher D, which were difficult to detect mechanically and were classified as more than high risk. In O, significantly higher values (p = 0.096) were found for FMs from MD and RN associated with much patient intervention compared to FMs from MP and RT less patient intervention. Comparing conventional radiotherapy and accelerator-based BNCT, although there were events with comparable risk in same FMs, there were also events with different risk in same FMs. They could be related to differences in the physical characteristics of the two modalities. CONCLUSIONS: This study is the first report for conducting a risk analysis for BNCT using FMEA. Thus, this study provides comprehensive data needed for quality assurance/quality control (QA/QC) in the treatment process for facilities considering the implementation of accelerator-based BNCT in the future. Because many BNCT-specific risks were discussed, it is important to understand the characteristics of BNCT and to take adequate measures in advance. If the effects of all FMs and countermeasures are discussed by multidisciplinary team, it will be possible to take countermeasures against individual FMs from many perspectives and provide BNCT more safely and effectively.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Humanos , Medición de Riesgo , Control de Calidad
14.
Breast Cancer ; 30(2): 157-166, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36547868

RESUMEN

Information regarding patients who were treated for breast cancer in 2018 was extracted from the National Clinical Database (NCD), which is run by Japanese physicians. This database continues from 1975, created by the Japanese Breast Cancer Society (JBCS). A total of 95,620 breast cancer cases were registered. The demographics, clinical characteristics, pathology, surgical treatment, adjuvant chemotherapy, adjuvant endocrine therapy, and radiation therapy of Japanese breast cancer patients were summarized. We made comparisons with other reports to reveal the characteristics of our database. We also described some features in Japanese breast cancer that changed over time. The unique characteristics of breast cancer patients in Japan may provide guidance for future research and improvement in healthcare services.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/terapia , Neoplasias de la Mama/tratamiento farmacológico , Japón/epidemiología , Terapia Combinada , Quimioterapia Adyuvante , Bases de Datos Factuales
15.
J Radiat Res ; 64(1): 186-194, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36316958

RESUMEN

This study aimed to clarify the differences in radiotherapy dose characteristics and delivery efficiency between the supine and prone positions in patients with prostate cancer using the CyberKnife. The planning computed tomography (CT) and delineations of the prone position were obtained by rotating the supine CT images with delineations of 180° using image processing software. The optimization parameters for planning target volume (PTV) and organs at risk (OARs) were based on the prone position. The optimization parameters determined for the prone position were applied to the supine position for optimization and dose calculation. The dosimetric characteristics of the PTV and OARs, and delivery efficiency were compared between the two different patient positions. The plans in the prone position resulted in better PTV conformity index (nCI), rectum V90%, V80%, V75%, V50% and bladder V50%. A significant difference was observed in treatment time and depth along the central axis (dCAX) between the two plans. The mean treatment time per fraction and dCAX for the supine and prone positions were 20.9 ± 1.7 min versus 19.8 ± 1.3 min (P = 0.019) and 151.1 ± 33.6 mm versus 233.2 ± 8.8 mm (P < 0.001), respectively. In this study the prone position was found to improve dosimetric characteristics and delivery efficiency compared with the supine position during prostate cancer treatment with the CyberKnife.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Radioterapia Conformacional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Posición Supina , Dosificación Radioterapéutica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Órganos en Riesgo , Posición Prona
16.
EJNMMI Phys ; 9(1): 89, 2022 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-36536190

RESUMEN

BACKGROUND: 18F-FDG PET is often utilized to determine BNCT selection due to the limited availability of 18F-BPA PET, which is performed by synthesizing 18F into the boron drug used for BNCT, although the uptake mechanisms between those are different. Additionally, only a few non-spatial point parameters, such as maximum SUV (SUVmax), have reported a correlation between those in previous studies. This study aimed to investigate the spatial accumulation pattern between those PET images in tumors, which would be expected to either show higher uptake on 18F-BPA PET or be utilized in clinical, to verify whether 18F-FDG PET could be used as a selection indicator for BNCT. METHODS: A total of 27 patients with 30 lesions (11 squamous cell carcinoma, 9 melanoma, and 10 rhabdomyosarcoma) who received 18F-FDG and 18F-BPA PET within 2 weeks were enrolled in this study. The ratio of metabolic tumor volumes (MTVs) to GTV, histogram indices (skewness/kurtosis), and the correlation of total lesion activity (TLA) and non-spatial point parameters (SUVmax, SUVpeak, SUVmin, maximum tumor-to-normal tissue ratio (Tmax/N), and Tmin/N) were evaluated. After local rigid registration between those images, distances of locations at SUVmax and the center of mass with MTVs on each image and similarity indices were also assessed along its coordinate. RESULTS: In addition to SUVmax, SUVpeak, and Tmax/N, significant correlations were found in TLA. The mean distance in SUVmax was [Formula: see text] and significantly longer than that in the center of mass with MTVs. The ratio of MTVs to GTV, skewness, and kurtosis were not significantly different. However, the similarities of MTVs were considerably low. The similarity indices of Dice similarity coefficient, Jaccard coefficient, and mean distance to agreement for MTV40 were [Formula: see text], [Formula: see text], and [Formula: see text] cm, respectively. Furthermore, it was worse in MTV50. In addition, spatial accumulation patterns varied in cancer types. CONCLUSIONS: Spatial accumulation patterns in tumors showed low similarity between 18F-FDG and 18F-BPA PET, although the various non-spatial point parameters were correlated. In addition, the spatial accumulation patterns were considerably different in cancer types. Therefore, the selection for BNCT using 18F-FDG PET should be compared carefully with using 18F-FBPA PET.

17.
Breast Cancer Res Treat ; 196(3): 635-645, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36273358

RESUMEN

PURPOSE: We aimed to determine the prognosis and potential benefit of postoperative chemotherapy according to subtype of medullary breast carcinoma (MedBC), a very rare invasive breast cancer. METHODS: A cohort of 1518 female patients with unilateral MedBC and 284,544 invasive ductal carcinoma (IDC) cases were enrolled from the Japanese Breast Cancer Registry. Prognosis of MedBC was compared to IDC among patients with estrogen receptor (ER)-negative and HER2-negative subtype (553 exact-matched patients) and ER-positive and HER2-negative subtype (163 MedBC and 489 IDC patients via Cox regression). Disease free-survival (DFS) and overall survival (OS) were compared between propensity score-matched adjuvant chemotherapy users and non-users with ER-negative and HER2-negative MedBC. RESULTS: Among ER-negative and HER2-negative subtype patients, DFS (hazard ratio (HR) 0.45; 95% confidence interval (95% CI), 0.30-0.68; log-rank P < 0.001) and OS (HR 0.51; 95% CI 0.32-0.83; log-rank P = 0.004) were significantly better in MedBC than IDC. Patients treated with postoperative chemotherapy showed better DFS (HR 0.27; 95% CI 0.09-0.80; log-rank P = 0.02) and OS (HR 0.27; 95% CI 0.09-0.80; log-rank P = 0.02) compared to those without. For the ER-positive and HER2-negative subtype, the point estimate for HR for DFS was 0.60 (95% CI 0.24-1.22) while that for OS was 0.98 (95% CI 0.46-1.84) for MedBC. CONCLUSION: In ER-negative and HER2-negative MedBC, the risk of recurrence and death was significantly lower than that of IDC, about half. Postoperative chemotherapy reduced recurrence and mortality. ER-positive and HER2-negative MedBC may have a lower risk of recurrence compared to IDC.


Asunto(s)
Neoplasias de la Mama , Carcinoma Ductal de Mama , Humanos , Femenino , Receptor ErbB-2 , Neoplasias de la Mama/patología , Carcinoma Ductal de Mama/tratamiento farmacológico , Carcinoma Ductal de Mama/patología , Pronóstico , Quimioterapia Adyuvante
18.
Laryngoscope Investig Otolaryngol ; 7(4): 994-1001, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36000039

RESUMEN

Purpose: The clinical characteristics and prognosis of HPV-related nasopharyngeal cancer (NPC) remain controversial. The relationship between p16 status and outcome was retrospectively investigated in the NPC patients. Materials and Methods: Between May 2009 and May 2019, 81 NPC patients who received definitive radiation therapy, in a hospital in Japan, were identified and the prognosis was investigated. p16, p53, and Epstein-Barr virus (EBV) status were assessed. Also, circumferential tumor extent in the nasopharyngeal cavity was assessed on a 5-point scale. Results: Nine and 72 patients were p16-positive and p16-negative, respectively. Fewer patients were EBV-encoded RNA in situ hybridization (EBER-ISH)-positive in the p16-positive group than in the p16-negative group (p < .01). Seventy-five patients were nonkeratinizing NPCs, and six patients were keratinizing NPCs. There were two p16-positive patients among the keratinizing NPCs.The mean circumferential tumor extent scores of 16-positive and p16-negative NPCs were 4.2 and 3.2, respectively with a statistically significant difference (p = .02). Two-year progression-free survival (PFS) of p16-positive and p16-negative patients undergoing chemoradiation therapy were 100% and 69%, respectively (p = .13). Conclusion: In this study conducted in Japan, p16-positive NPC patients are minor but not very low, and the proportion of keratinizing NPCs was small. p16-positive NPCs were seen both in keratinizing and nonkeratinizing NPCs. P16-positive NPC had a tendency of better PFS than p16-negative NPC. This better prognosis might be due to the higher radiosensitivity of the p16-positive cell. Additionally, p16-positive NPCs seemed to spread more extensively in circumference along the nasopharyngeal mucosa than p16-negative NPCs.

19.
Breast Cancer ; 29(6): 985-992, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35733033

RESUMEN

BACKGROUND: Male breast cancer (MBC) is rare; however, its incidence is increasing. There have been no large-scale reports on the clinicopathological characteristics of MBC in Japan. METHODS: We investigated patients diagnosed with breast cancer in the Japanese National Clinical Database (NCD) between January 2012 and December 2018. RESULTS: A total of 594,316 cases of breast cancer, including 3780 MBC (0.6%) and 590,536 female breast cancer (FBC) (99.4%), were evaluated. The median age at MBC and FBC diagnosis was 71 (45-86, 5-95%) and 60 years (39-83) (p < 0.001), respectively. MBC cases had a higher clinical stage than FBC cases: 7.4 vs. 13.3% stage 0, 37.2 vs. 44.3% stage I, 25.6 vs. 23.9% stage IIA, 8.8 vs. 8.4% stage IIB, 1.9 vs. 2.4% stage IIIA, 10.1 vs. 3.3% stage IIIB, and 1.1 vs. 1.3% stage IIIC (p < 0.001). Breast-conserving surgery was more frequent in FBC (14.6 vs. 46.7%, p = 0.02). Axillary lymph node dissection was more frequent in MBC cases (32.9 vs. 25.2%, p < 0.001). Estrogen receptor(ER)-positive disease was observed in 95.6% of MBC and 85.3% of FBC cases (p < 0.001). The HER2-positive disease rates were 9.5% and 15.7%, respectively (p < 0.001). Comorbidities were more frequent in MBC (57.3 vs. 32.8%) (p < 0.001). Chemotherapy was less common in MBC, while endocrine therapy use was similar in ER-positive MBC and FBC. Perioperative radiation therapy was performed in 14.3% and 44.3% of cases. CONCLUSION: Japanese MBC had an older age of onset, were more likely to be hormone receptor-positive disease, and received less perioperative chemotherapy than FBC.


Asunto(s)
Neoplasias de la Mama Masculina , Humanos , Masculino , Femenino , Neoplasias de la Mama Masculina/epidemiología , Neoplasias de la Mama Masculina/terapia , Neoplasias de la Mama Masculina/diagnóstico , Receptores de Estrógenos , Japón/epidemiología , Mastectomía Segmentaria , Sistema de Registros
20.
Phys Imaging Radiat Oncol ; 23: 1-7, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35712526

RESUMEN

Background and purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART) is a new technology of radiotherapy and requires a new quality control program in many aspects. This study aimed to gain a deeper understanding of risks in online MRgART through the application of failure mode and effect analysis (FMEA) for more enhanced and effective quality assurance (QA) programs. Materials and methods: We present an FMEA conducted by a multidisciplinary team with more than two years of experience. A process map describing the whole process of online MRgART was developed and potential failure modes were identified. High-risk failure modes and their potential causes and corrective measures were also identified. Failure modes were classified into three categories, MRgRT, online ART, and conventional RT, to investigate their features. A comparison with previous studies was also conducted to gain a general perspective. Results: In total, 153 failure modes and 49 high risks were identified. Among all failure modes, 51, 63, and 66 were related to MRgRT, online ART, and conventional RT, respectively. The hazardous processes were structure segmentation, treatment planning, and treatment beam delivery. Lists of failure modes identified in this study and previous studies were presented. Based on the results, characteristics and general aspects of the risks were discussed. Conclusion: Exploring the results of the FMEA enhanced our understanding of risk characteristics to improve QA program of online MRgART.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA