1.
IEEE J Biomed Health Inform ; 26(1): 478, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-35038291

RESUMEN

In [1], the dose estimation accuracy using the alternative baseline method under modulated tube current was not correctly calculated due to an unintentional simulation error.

2.
IEEE J Biomed Health Inform ; 25(8): 3061-3072, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33651703

RESUMEN

OBJECTIVE: This study aims to develop and validate a novel framework, iPhantom, for automated creation of patient-specific phantoms or "digital-twins (DT)" using patient medical images. The framework is applied to assess radiation dose to radiosensitive organs in CT imaging of individual patients. METHOD: Given a volume of patient CT images, iPhantom segments selected anchor organs and structures (e.g., liver, bones, pancreas) using a learning-based model developed for multi-organ CT segmentation. Organs which are challenging to segment (e.g., intestines) are incorporated from a matched phantom template, using a diffeomorphic registration model developed for multi-organ phantom-voxels. The resulting digital-twin phantoms are used to assess organ doses during routine CT exams. RESULT: iPhantom was validated on both with a set of XCAT digital phantoms (n = 50) and an independent clinical dataset (n = 10) with similar accuracy. iPhantom precisely predicted all organ locations yielding Dice Similarity Coefficients (DSC) 0.6 - 1 for anchor organs and DSC of 0.3-0.9 for all other organs. iPhantom showed <10% errors in estimated radiation dose for the majority of organs, which was notably superior to the state-of-the-art baseline method (20-35% dose errors). CONCLUSION: iPhantom enables automated and accurate creation of patient-specific phantoms and, for the first time, provides sufficient and automated patient-specific dose estimates for CT dosimetry. SIGNIFICANCE: The new framework brings the creation and application of CHPs (computational human phantoms) to the level of individual CHPs through automation, achieving wide and precise organ localization, paving the way for clinical monitoring, personalized optimization, and large-scale research.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen
3.
Med Phys ; 45(7): 3147-3160, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29757473

RESUMEN

PURPOSE: Often, the inverse deformation vector field (DVF) is needed together with the corresponding forward DVF in four-dimesional (4D) reconstruction and dose calculation, adaptive radiation therapy, and simultaneous deformable registration. This study aims at improving both accuracy and efficiency of iterative algorithms for DVF inversion, and advancing our understanding of divergence and latency conditions. METHOD: We introduce a framework of fixed-point iteration algorithms with active feedback control for DVF inversion. Based on rigorous convergence analysis, we design control mechanisms for modulating the inverse consistency (IC) residual of the current iterate, to be used as feedback into the next iterate. The control is designed adaptively to the input DVF with the objective to enlarge the convergence area and expedite convergence. Three particular settings of feedback control are introduced: constant value over the domain throughout the iteration; alternating values between iteration steps; and spatially variant values. We also introduce three spectral measures of the displacement Jacobian for characterizing a DVF. These measures reveal the critical role of what we term the nontranslational displacement component (NTDC) of the DVF. We carry out inversion experiments with an analytical DVF pair, and with DVFs associated with thoracic CT images of six patients at end of expiration and end of inspiration. RESULTS: The NTDC-adaptive iterations are shown to attain a larger convergence region at a faster pace compared to previous nonadaptive DVF inversion iteration algorithms. By our numerical experiments, alternating control yields smaller IC residuals and inversion errors than constant control. Spatially variant control renders smaller residuals and errors by at least an order of magnitude, compared to other schemes, in no more than 10 steps. Inversion results also show remarkable quantitative agreement with analysis-based predictions. CONCLUSION: Our analysis captures properties of DVF data associated with clinical CT images, and provides new understanding of iterative DVF inversion algorithms with a simple residual feedback control. Adaptive control is necessary and highly effective in the presence of nonsmall NTDCs. The adaptive iterations or the spectral measures, or both, may potentially be incorporated into deformable image registration methods.


Asunto(s)
Retroalimentación , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Tomografía Computarizada por Rayos X