Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 918(1): 67-78, 2001 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-11403457

RESUMEN

It was demonstrated that four out of six of the very polar organophosphorus pesticides (OPs), i.e. acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion, could not be extracted from water using commonly available SPE cartridges. In addition, GC analysis on all six compounds was found to be troublesome due to their polar and thermolabile character. This initiated the development of an alternative highly sensitive and selective method for the determination of the above mentioned very polar OPs in water, based on LC-MS. Large volume (1 ml) water samples were directly injected onto an RP18 HPLC column with a polar endcapping. The latter was essential for obtaining retention and maintaining column performance under 100% aqueous conditions during the sampling. The compounds were ionized using atmospheric pressure chemical ionization and detected on a tandem mass spectrometer operated in multiple reaction-monitoring mode. The detection limits were in the range of 0.01-0.03 microg/l. Compared to conventional GC methods, the developed LC-MS procedure is very straightforward, fast and more reliable. This application demonstrates the applicability of LC-MS for analysis of polar OPs in surface, ground and drinking water, as a more favourable alternative to GC.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Insecticidas/análisis , Espectrometría de Masas/métodos , Compuestos Organofosforados , Agua/química , Cromatografía de Gases , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Curr Top Med Chem ; 1(5): 443-62, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11899107

RESUMEN

Over the last years, there has been an exponentially growing need and interest to bring pharmacokinetic expertise into discovery. In order to allow a multidisciplinary selection and a higher attrition rate, both the in vivo and in vitro pharmacokinetic parameters of an ever increasing number of tentative new chemical entities are evaluated in an earlier phase of Drug Discovery. A higher attrition rate at the beginning of the pipeline should result in a lower attrition rate at a later stage in development. In this process, the bioanalytical laboratory has become increasingly important. Analytical strategies needed to be adapted to cope with novel experimental designs such as cassette dosing, cassette analysis or 96-well techniques. At the same time, HT-synthesis programs surfaced a broader variety of chemical classes to be investigated, disfavoring further generalization of analytical approaches. Progress in lab automation, improved chromatographic techniques and the proliferation of LC-MS/MS enabled the analyst to deal with these challenges much faster and with a higher level of confidence. Quality standards regarding method development and method validation, setting the boundaries for more than a decade, needed to be titrated to reach an optimal balance between speed and quality. This review will give an illustrative overview of the bioanalytical techniques and strategies used to support Drug Discovery, together with some pitfalls related to the overzealous use of new techniques.


Asunto(s)
Técnicas de Química Analítica/métodos , Evaluación Preclínica de Medicamentos/métodos , Farmacocinética , Técnicas de Química Analítica/instrumentación , Técnicas de Química Analítica/normas , Cromatografía Liquida/normas , Evaluación Preclínica de Medicamentos/normas , Cromatografía de Gases y Espectrometría de Masas/normas , Control de Calidad
3.
J Am Soc Mass Spectrom ; 11(6): 578-86, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10833032

RESUMEN

Reactive nitrogen species such as peroxynitrite can nitrate specific amino acids, whether free or protein bound, and 3-nitrotyrosine is believed to be one marker of this reaction. To examine the significance of this pathway in biological systems we have developed an accurate, sensitive, and specific assay for 3-nitrotyrosine based on combined liquid chromatography tandem mass spectrometry. Our approach allowed simultaneous analysis of both tyrosine and 3-nitrotyrosine and employs isotopomer standards (i.e., [15N1, 13C9]-tyrosine and [13C6]-3nitrotyrosine). Calibration curves were linear (r2 = 0.999) across the range 0.5-100 pg/microL (i.e., 2.2-442 fmol/microL), and the detection limit for standard samples was 0.5 pg/microL (2.2 fmol/microL, or 10 fmol on column; S/N = 5) or 1 pg/microL (4.4 fmol/microL) for extracted (biological) samples. As a component of this study we have undertaken an extensive investigation of artifactual formation of 3-nitrotyrosine under conditions that exist during sample extraction and derivatization. Our studies show that under appropriate conditions (low pH, elevated temperatures, and in the presence of a vast excess of the two substrates, tyrosine and the nitrate anion), 3-nitrotyrosine can readily be formed as an artifact.


Asunto(s)
Tirosina/análogos & derivados , Animales , Artefactos , Cromatografía de Gases y Espectrometría de Masas , Humanos , Ratas , Estándares de Referencia , Líquido Sinovial/metabolismo , Distribución Tisular , Tirosina/análisis , Tirosina/sangre , Tirosina/orina
4.
Free Radic Biol Med ; 27(3-4): 254-61, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10468196

RESUMEN

A thymine-tyrosine adduct, (3-[(1,3-dihydro-2,4-dioxopyrimidin-5-yl)methyl]-L-tyrosine), was synthesized using a simple, single-step condensation between 5-(hydroxymethyl)uracil and L-tyrosine. This approach provides access to useful quantities (mg-g) of analytically pure reference material, and with minor modification, to stable isotope-labeled analogues (isotopomers). With reference material and a suitable internal standard available, isotope-dilution liquid chromatography-electrospray ionization-tandem mass spectrometry (LC/MS/MS) was used to assay the adduct in a model system purged of oxygen, i.e., a gamma-irradiated N2O-saturated aqueous solution of thymine and tyrosine. The convenient synthetic route to standards and the method for quantification reported here will prove useful in assessing the significance of the adduct in biological systems. These studies also highlight the potential for artefactual adduct formation if the appropriate substrates are present under acidic conditions.


Asunto(s)
Aductos de ADN/síntesis química , Proteínas de Unión al ADN/síntesis química , Timina/análogos & derivados , Tirosina/análogos & derivados , Cromatografía Liquida , Reactivos de Enlaces Cruzados , Cristalografía por Rayos X , Aductos de ADN/análisis , Proteínas de Unión al ADN/análisis , Cromatografía de Gases y Espectrometría de Masas , Espectroscopía de Resonancia Magnética , Espectrometría de Masas , Modelos Moleculares , Timina/análisis , Timina/síntesis química , Tirosina/análisis , Tirosina/síntesis química
5.
Electrophoresis ; 18(6): 938-42, 1997 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9221881

RESUMEN

Chiral interaction in capillary electrophoresis can be modeled using pK values, mobilities of analytes, and their formation constants with the chiral selector. An existing steady-state simulation program for CE (HPCESIM) was recently extended with a chiral submenu involving the chiral parameters listed above. These were experimentally determined in both our laboratories for mandelic acid and terbutaline using hydroxypropylated beta-cyclodextrin as chiral selector. A comparison was made between both sets of parameters and between experimental electropherograms and those obtained from simulation. Error analysis of the results indicate the sensitivity of the obtained results.


Asunto(s)
Simulación por Computador , Electroforesis Capilar/métodos , Ácidos Mandélicos/análisis , Ácidos Mandélicos/química , Conformación Molecular , Terbutalina/análisis , Terbutalina/química
6.
J Pharm Biomed Anal ; 14(8-10): 1089-94, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8818019

RESUMEN

This paper describes the development of a capillary zone electrophoretic method for chiral separation of three basic compounds of the selegiline synthetic pathway: ephedrine, methamphetamine and selegiline. The method developed allows one to separate the studied compounds in one run using a neutral beta-cyclodextrin epichlorhydrin polymer. The effect of various experimental parameters, such as chiral selector concentration, concentration and composition of background electrolyte, pH, temperature, and the addition of some organic solvents, on the resolution and migration time is discussed. For selegiline and methamphetamine, it is possible, under optimal conditions, to quantify less than 0.5% of the minor isomer in an excess of the major one.


Asunto(s)
Ciclodextrinas , Efedrina/aislamiento & purificación , Epiclorhidrina , Drogas Ilícitas/aislamiento & purificación , Indicadores y Reactivos , Metanfetamina/aislamiento & purificación , Polímeros , Selegilina/aislamiento & purificación , beta-Ciclodextrinas , Electroforesis Capilar , Concentración de Iones de Hidrógeno , Concentración Osmolar , Estereoisomerismo , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...